• Title/Summary/Keyword: skull specimen

Search Result 11, Processing Time 0.028 seconds

First Record of the Melon-headed Whale (Peponocephala electra) in Korean Waters

  • Kim, Hyun-Woo;Moon, Dae-Yeon;Choi, Seok-Gwan;An, Yong-Rock;Kim, Zang-Geun
    • Animal Systematics, Evolution and Diversity
    • /
    • v.26 no.1
    • /
    • pp.59-62
    • /
    • 2010
  • First record of a stranded Melon-headed whale (Peponocephala electra) on the south-east coast of Korea was described. Full body and skull measurements were taken from the specimen. It was identified as P. electra by unique pointed flipper tips. Skull measurements of the specimen corresponded to condylobasal length proportions given in the previous descriptions of the holotype.

A Case of Calvarial Hemangioma in Cranioplasty Site

  • Kang, Dong-Wan;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.5
    • /
    • pp.484-487
    • /
    • 2009
  • It is not uncommon for hemangiomas to occur in the calvarium, accounting for about 10% of the benign skull tumors. A 46-year-old man was presented with a palpable scalp mass on the left parietal region. Past medical history indicated that he had undergone cranioplasty 25 years prior due to a depressed skull fracture suffered from a traffic accident. Magnetic resonance imaging revealed mixed signal intensity mass on T1 -and T2- weighted images pushing a linear signal void lesion outward in the left parietal region. After total surgical removal along with cranioplasty, he was discharged without neurological deficits. Histological examination of the surgical specimen revealed a cavernous hemangioma. A skull hemangioma occurring at the site of a cranioplasty has not yet been reported. Therefore, authors report this case in combination with a pertinent literature review.

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF

First Record of the Fraser's Dolphin (Lagenodelphis hosei) in Korean Waters

  • Kim, Hyun Woo;An, Yong-Rock;An, Du Hae;Kim, Zang Geun
    • Animal Systematics, Evolution and Diversity
    • /
    • v.29 no.2
    • /
    • pp.175-178
    • /
    • 2013
  • The Fraser's dolphin, Lagenodelphis hosei has a pantropical distribution. Only several stranding or catch data were available from Japan and Taiwan in the north-west Pacific region. An adult female L. hosei stranded in Jeju-do, Korea. The specimen was identified by external features and skull measurements. It showed the same external appearance ratio and range in the number of teeth with L. hosei former described. The cranial measurements also well corresponded to condylobasal length proportions given in the previous descriptions of the holotype. This is the first record of the species in Korean waters. We report the information on external and osteological characters of the specimen.

A Case Report of Giant Cell Tumor of the Occipital Bone (후두골에 발생한 거대세포종 (giant cell tumor)의 수술적 치험례)

  • Jo, Sung Hyun;Kim, Jin Woo;Jung, Jae Hak;Kim, Young Hwan;Sun, Hook
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.2
    • /
    • pp.103-106
    • /
    • 2010
  • Purpose: Giant cell tumors of the bone are rare, locally aggressive lesions that primarily affect the epiphysis of the long bones in young adults. These tumors occur very rarely on the skull, principally in the sphenoid and temporal bones. The occipital bone is an unusual site. We report a rare case of a giant cell tumor of the occipital bone with a review of the relevant literature. Methods: A 7-year-old boy presented with a mass of the right occipital area, which was accompanied by localized tenderness and mild swelling. The mass was first recognized approximately 1 year earlier and grew slowly. There was no significant history of trauma. The physical examination revealed a nonmobile and non-tender bony swelling on the occipital region. The neurological evaluation was normal. The serial skull radiography and CT scan showed focal osteolytic bone destruction with a bulged soft tissue mass in the right occipital bone. The patient underwent a suboccipital craniectomy and a complete resection of the epidural mass. The lesion was firm and cystic. The mass adhered firmly to the dura mater. Results: The postoperative clinical course was uneventful, and the patient was discharged 5 days later. The histopathology report revealed scattered multinucleated giant cells and mononuclear stromal cells at the tumor section, and the giant cells were distributed evenly in the specimen, indicating a giant cell tumor. Conclusion: Giant cell tumors are generally benign, locally aggressive lesions. In our case, the lesion was resected completely but a persistent long term follow up will be needed because of the high recurrence rate and the possible transformation to a malignancy.

Successful Combination Chemotherapy for Nasal Carcinoma in a Dog

  • Kim, Su-Gang;Cho, Seok-Ho;Kim, Keon;Park, Hee-Myung;Park, Sang-Ik;Kim, Tae-Jung;Lee, Chang-Min
    • Journal of Veterinary Clinics
    • /
    • v.36 no.5
    • /
    • pp.274-277
    • /
    • 2019
  • A Miniature Schnauzer presented with bilateral mucopurulent nasal discharge and sneezing. Computed tomography of the skull revealed exudates in the nasal cavity and frontal gyrus. Nasal swab cytology showed features of an epithelial-origin tumor. Histopathologic evaluation of the biopsy specimen revealed irregular proliferation of epithelial cells and necrotized tissue. Positive immunohistochemical staining confirmed the epithelial origin of the cells. The dog was diagnosed with nasal carcinoma and was treated with a chemotherapy protocol of carboplatin and piroxicam. This report confirms the effectiveness of combination chemotherapy only without radiotherapy in a dog with nasal carcinoma and provides a guideline for providing alternative treatment.

Color Enhancement for Cubic Zirconia with Low Temperature Annealing (큐빅지르코니아의 색향상을 위한 저온열처리 공정 연구)

  • Li, Feng;Shen, Yun;Song, Oh-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1186-1191
    • /
    • 2010
  • Colored cubic zirconia specimen made by skull melt process were annealed in vacuum at the temperature of $1200^{\circ}C{\sim}1400^{\circ}C$ for 10~60 minutes to enhance the color. All the seven specimen become darker and eventually be black as annealing temperature and time increase. The black samples turned into original colors when we elevated the temperature with oxy-acetylene torch for around 10 minutes in the air. Finally, we could tune the colors of cubic zirconia either anneal in vacuum or the black samples in the air to obtain the proposed colors. Our proposed new process may be appropriate to fabricate the precious synthetic colored cubic zirconia to simulate the natural colored gem quality diamonds.

Change of the Scattered Dose by Field Size in X-ray Radiography (X선 촬영에서 조사야 크기에 따른 산란선량의 변화)

  • Choi, Seong-Kwan
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.198-203
    • /
    • 2013
  • The purpose of this study is to investigate the scattered dose of X-ray at a distance of 30cm from the area to be examined when X-ray field is the most optimized and maximized when X-ray is performed on hand, skull and abdomen. As a result of scattered dose of X-ray on hand, skull and abdomen, first, when X-ray field was the most optimized upon adult X-ray examination, it was $0.08{\mu}Sv$, $4.39{\mu}Sv$ and $5.56{\mu}Sv$, respectively. When x-ray field was maximized, it was $0.58{\mu}Sv$, $33.47{\mu}Sv$ and $35.93{\mu}Sv$, respectively. Second, when X-ray field was the most optimized upon pediatric X-ray examination, it was $0.40{\mu}Sv$, $14.51{\mu}Sv$ and $18.86{\mu}Sv$, respectively. When x-ray field was maximized, it was $2.78{\mu}Sv$, $107.40{\mu}Sv$ and $117.52{\mu}Sv$, respectively(P<0.001). As a result, when the size of X-ray field was decreased down to be necessary and optimal upon X-ray examination, emission of scattered X-ray around specimen is reduced approximately 6-7 times as much as that when it was maximized.

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

Initial tissue response of biodegradable membrane in rat subcutaneous model (백서 피하층에서 흡수성 차단막의 초기 조직 반응)

  • Lim, Hyun-Chang;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Lee, Yong-Keun;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.839-848
    • /
    • 2007
  • Purpose: Various kinds of biodegradable membranes are currently used in dental clinics. And the frequency and the necessity of their usage are increasing due to their numerous advantages. Therefore it is important to understand the difference of various membranes and histological reaction against implanted membranes. Materials and Methods: Biodegradable membranes of $Biogide^{(R)}$, $Resolute^{(R)}$, and $Tutodent^{(R)}$ were cut into small pieces by $1.0{\times}0.5cm$. The membranes were implanted 1.5cm apart from each other under the epithelium on the skull of 18 Sprague Dawley rats. The animals were sacrificed at 3, 7, and 14 days after surgical procedure. The specimens were examined by histological analysis. Results: 1. Early period after implantation of the membranes showed connective tissues surrounding membranes and there were a few inflammatory cells present. 2. In $Biogide^{(R)}$ and $Tutodent^{(R)}$ specimens, inflammatory cells and surrounding tissues were shown to infiltrate from outside with slight density difference inside. In $Resolute^{(R)}$ specimens, membranes were fragmented. Inflammatory cells and connective tissues were also observed inside. 3. In $Resolute^{(R)}$ specimen, giant cells were present which implicates that foreign body reaction has occurred. 4. $Biogide^{(R)}$ had lower integrity than other membranes and is not enough to be used alone in defect area. However, $Resolute^{(R)}$ had superior firmness than others. $Tutodent^{(R)}$ had middle level of integrity. Conclusion: This experimental model enabled to observe early inflammatory reactions and morphological changes of materials and can be used to develop and evaluate the efficacy of biodegradable membranes. Duplication of standardized human oral environment will be required in future experiments.