• 제목/요약/키워드: skull

검색결과 860건 처리시간 0.028초

Clinical Comparison of the Predictive Value of the Simple Skull X-Ray and 3 Dimensional Computed Tomography for Skull Fractures of Children

  • Kim, Young-Im;Cheong, Jong-Woo;Yoon, Soo Han
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권6호
    • /
    • pp.528-533
    • /
    • 2012
  • Objective : In the pediatric population the skull has not yet undergone ossification and it is assumed that the diagnostic rate of skull fractures by simple X-rays are lower than that of adults. It has been recently proposed that the diagnostic rates of skull fractures by 3-dimensional computer tomography (3D-CT) are higher than simple X-rays. The authors therefore attempted to compare the diagnostic rates of pediatric skull fractures by simple X-rays and 3D-CTs with respect to the type of fracture. Methods : One-hundred patients aged less than 12 years who visited the Emergency Center for cranial injury were subject to simple X-rays and 3D-CTs. The type and location of the fractures were compared and Kappa statistical analysis and the t-test were conducted. Results : Among the 100 pediatric patients, 65 were male and 35 were female. The mean age was $50{\pm}45$ months. 63 patients had simple skull fractures and 22 had complex fractures, and the types of fractures were linear fractures in 74, diastatic fractures 15, depressed fractures in 10, penetrating fracture in 1, and greenstick fractures in 3 patients. Statistical difference was observed for the predictive value of simple skull fractures' diagnostic rate depending on the method for diagnosis. A significant difference of the Kappa value was noted in the diagnosis of depressed skull fractures and diastatic skull fractures. Conclusion : In the majority of pediatric skull fractures, 3D-CT showed superior diagnosis rates compared to simple skull X-rays and therefore 3D-CT is recommended whenever skull fractures are suspected. This is especially true for depressed skull fractures and diastatic skull fractures.

Factors Related to Successful Energy Transmission of Focused Ultrasound through a Skull : A Study in Human Cadavers and Its Comparison with Clinical Experiences

  • Jung, Na Young;Rachmilevitch, Itay;Sibiger, Ohad;Amar, Talia;Zadicario, Eyal;Chang, Jin Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권6호
    • /
    • pp.712-722
    • /
    • 2019
  • Objective : Although magnetic resonance guided focused ultrasound (MRgFUS) has been used as minimally invasive and effective neurosurgical treatment, it exhibits some limitations, mainly related to acoustic properties of the skull barrier. This study was undertaken to identify skull characteristics that contribute to optimal ultrasonic energy transmission for MRgFUS procedures. Methods : For ex vivo skull experiments, various acoustic fields were measured under different conditions, using five non-embalmed cadaver skulls. For clinical skull analyses, brain computed tomography data of 46 patients who underwent MRgFUS ablations (18 unilateral thalamotomy, nine unilateral pallidotomy, and 19 bilateral capsulotomy) were retrospectively reviewed. Patients' skull factors and sonication parameters were comparatively analyzed with respect to the cadaveric skulls. Results : Skull experiments identified three important factors related skull penetration of ultrasound, including skull density ratio (SDR), skull volume, and incidence angle of the acoustic rays against the skull surface. In clinical results, SDR and skull volume correlated with maximal temperature (Tmax) and energy requirement to achieve Tmax (p<0.05). In addition, considering the incidence angle determined by brain target location, less energy was required to reach Tmax in the central, rather than lateral targets particularly when compared between thalamotomy and capsulotomy (p<0.05). Conclusion : This study reconfirmed previously identified skull factors, including SDR and skull volume, for successful MRgFUS; it identified an additional factor, incidence angle of acoustic rays against the skull surface. To guarantee successful transcranial MRgFUS treatment without suffering these various skull issues, further technical improvements are required.

Study on Changes in Shape of Denatured Area in Skull-mimicking Materials Using Focused Ultrasound Sonication

  • Min, JeongHwa;Kim, JuYoung;Jung, HyunDu;Kim, JaeYoung;Noh, SiCheol;Choi, HeungHo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제3권1호
    • /
    • pp.28-34
    • /
    • 2014
  • Recently, ultrasound therapy has become a new and effective treatment for many brain diseases. Therefore, skull-mimicking phantoms have been developed to simulate the skull and brain tissue of a human and allow further research into ultrasound therapy. In this study, the suitability of various skull-mimicking materials(HDPE, POM C, Acrylic) for studies of brain-tumor treatments was evaluated using focused ultrasound. The acoustic properties of three synthetic resins were measured. The skull-mimicking materials were then combined with an egg white phantom to observe the differences in the ultrasound beam distortion according to the type of material. High-intensity polyethylene was found to be suitable as a skull-mimicking phantom because it had acoustic properties and a denatured-area shape that was close to those of the skull,. In this study, a skull-mimicking phantom with a multi-layer structure was produced after evaluating several skull-mimicking materials. This made it possible to predict the denaturation in a skull in relation to focused ultrasound. The development of a therapeutic protocol for a range of brain diseases will be useful in the future.

3D Printed Titanium Implant for the Skull Reconstruction: A Preliminary Case Study

  • Choi, Jong-Woo;Ahn, Jae-Sung
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권2호
    • /
    • pp.99-102
    • /
    • 2014
  • The skull defect can be made after the trauma, oncologic problems or neurosurgery. The skull reconstruction has been the challenging issue in craniofacial fields for a long time. So far the skull reconstruction with autogenous bone would be the standard. Although the autogenous bone would be the ideal one for skull reconstruction, donor site morbidity would be the inevitable problem in many cases. Meanwhile various types of allogenic and alloplastic materials have been also used. However, skull reconstruction with many alloplastic material have produced no less complications including infection, exposure, and delayed wound healing. Because the 3D printing technique evolved so fast that 3D printed titanium implant were possible recently. The aim of this trial is to try to restore the original skull anatomy as possible using the 3D printed titanium implant, based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. And we fabricated Titanium implant to reconstruct three-dimensional orbital structure in advance, using the 3D printer. This prefabricated Titanium-implant was then inserted onto the defected skull and fixed. Three dimensional printing technique of titanium material based on the computer simulation turned out to be very successful in this patient. Individualized approach for each patient could be an ideal way to manage the traumatic patients in near future.

Structural complexity of the craniofacial trabecular bone in multiple myeloma assessed by fractal analysis

  • Michels, Mariane;Morais-Faria, Karina;Rivera, Cesar;Brandao, Thais Bianca;Santos-Silva, Alan Roger;Oliveira, Matheus L
    • Imaging Science in Dentistry
    • /
    • 제52권1호
    • /
    • pp.33-41
    • /
    • 2022
  • Purpose: This study aimed to evaluate the structural complexity of craniofacial trabecular bone in multiple myeloma by fractal analysis of panoramic and lateral skull radiography, and to compare the fractal dimension values of healthy patients (HPs), pre-treatment patients (PTPs), and patients during bisphosphonate treatment (DTPs). Materials and Methods: Pairs of digital panoramic and lateral skull radiographs of 84 PTPs and 72 DTPs were selected. After application of exclusion criteria, 43 panoramic and 84 lateral skull radiographs of PTPs, 56 panoramic and 72 lateral skull radiographs of DTPs, and 99 panoramic radiographs of age- and sex-matched HPs were selected. The fractal dimension values from panoramic radiographs were compared among HPs, PTPs, and DTPs and between anatomical locations within patient groups using analysis of variance with the Tukey test. Fractal dimension values from lateral skull radiographs were compared between PTPs and DTPs using the Student t-test. Pearson correlation coefficients were used to assess the relationship between the mandible from panoramic radiographs and the skull from lateral skull radiographs. Intra-examiner agreement was assessed using intraclass correlation coefficients (α=0.05). Results: The fractal dimension values were not significantly different among HPs, PTPs, and DTPs on panoramic radiographs or between PTPs and DTPs on lateral skull radiographs (P>0.05). The mandibular body presented the highest fractal dimension values (P≤0.05). The fractal dimension values of the mandible and skull in PTPs and DTPs were not correlated. Conclusion: Fractal analysis was not sensitive for distinguishing craniofacial trabecular bone complexity in multiple myeloma patients using panoramic and lateral skull radiography.

해골 이미지를 응용한 여자 청소년 상의(Top)디자인 (Top Design by Skull Image for Female Teenagers)

  • 류경옥
    • 한국의상디자인학회지
    • /
    • 제14권1호
    • /
    • pp.123-130
    • /
    • 2012
  • The purpose of this study is to understand Skull Images in fashion trends and Skull Image Top Design for Female Teenagers. The methods of this study are an academic literature review as well as practical study through actual case studies about. The subjects of the study were 53 Female Teenagers who lived in Chuncheon. Data were collected during March, 2009. Statistical analyses used in the study were frequency. An adolescent period, they are rebellious, sensual and syntonic inclination. These days, Lots of Female Teenagers want unique fashion for herself and select Skull Image clothing. But they want fit and pretty style not big-look. In this study, I designed seven pieces of Top blouse while applying Skull Image, an important image of Hip-hop and Punk fashion, and the concepts of the continuance theory to them. This study will make a contribution to the designing of Top for Female Teenagers through reinterpretation of the Hip-hop and Punk fashion. In addition, there are practicable and unique Top design for Female Teenagers.

  • PDF

로봇을 이용한 두개골 천공 시스템의 공구 경로 생성 (Tool-path Generation for a Robotic Skull Drilling System)

  • 정연찬
    • 한국CDE학회논문집
    • /
    • 제18권4호
    • /
    • pp.243-249
    • /
    • 2013
  • This paper presents a tool-path generation methods for an automated robotic system for skull drilling, which is performed to access to some neurosurgical interventions. The path controls of the robotic system are classified as move, probe, cut, and poke motions. The four motions are the basic motion elements of the tool-paths to make a hole on a skull. Probing, rough cutting and fine cutting paths are generated for skull drilling. For the rough cutting path circular paths are projected on the offset surfaces of the outer top and the inner bottom surfaces of the skull. The projected paths become the paths on the top and bottom layers of the rough cutting paths. The two projected paths are blended for the paths on the other layers. Syntax of the motion commands for a file format is also suggested for the tool-paths. Implementation and simulation results show that the possibility of the proposed methods.

Elevation of Depressed Skull Fracture with a Cup of Breast Pump and a Suction Generator : A Case Report in Technical Aspects

  • Kim, Young-Jin;Lee, Sang-Koo;Cho, Maeng-Ki;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권4호
    • /
    • pp.346-348
    • /
    • 2007
  • Surgical elevation of the depressed bone is known to be the conventional treatment usually recommended for a simple depressed skull fracture in the adult or pediatric age. The authors introduce, however, a case of depressed skull fracture in an infant which was elevated by means of a cup of breast pump and a suction generator without surgical elevation. In our case, without surgery, a 'cup-shaped' depressed skull fracture in an infant was safely elevated with no neurological signs. This method is considered a simple, effective, safe, and alternative procedure in an infant with simple depressed skull fracture.

Morphology Operations on CUDA To Remove Skull on MRI Images

  • 요니 셉티안;최흥국
    • 한국멀티미디어학회:학술대회논문집
    • /
    • 한국멀티미디어학회 2012년도 춘계학술발표대회논문집
    • /
    • pp.205-208
    • /
    • 2012
  • Nowadays GPU (Graphic Process Unit) is not only used to show and render some images, but also for another computation. In this paper, we tried to use GPU to do some morphology operations to remove skull from axial MRI images. This skull removing process is an important step in brain segmentation because we would like to work with the brain only, without any skull on it. The result shows that simple morphology operations to remove skull has been successfully applied on MRI images, but there are still many parts that can be develop to get better images.

  • PDF

다양한 X-ray 촬영조건을 이용하여 획득한 skull 영상에서의 Total Variation 알고리즘의 가능성 연구 (A Study on Feasibility of Total Variation Algorithm in Skull Image using Various X-ray Exposure Parameters)

  • 박성우;이종인;이영진
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.765-771
    • /
    • 2019
  • Skull X-ray 영상에서 노이즈의 발생은 불가피하며, 이는 영상 화질과 진단 정확도를 저하시키고 디지털 영상 장치의 특성상 오류를 증가시킨다. 이러한 노이즈는 선량을 증가시키면 쉽게 감쇠되긴 하지만 환자가 받는 피폭선량이 더 큰 문제를 야기할 수 있다. 그래서 선량문제를 해결하고 동시에 노이즈를 줄이기 위해저 선량에서 노이즈 감소 알고리즘이 활발히 연구되고 있는데, 초기에 개발되고 널리 사용되어진 median filter와 Wiener filter는 노이즈 감소 효율이 떨어지고 영상경계에 대한 정보가 많이 손실된다는 단점이 있다. 본 연구의 목적은 이전 노이즈 감소효율의 문제점을 보완할 수 있는 total variation (TV) 알고리즘을 skull X-ray 영상에 적용하여 정량적으로 평가하고 비교를 하는 것이다. 이를 위해 Siemens사의 X-ray 장치를 사용하여 성인 skull을 모사할 수 있는 팬텀을 통해 다양한 관전압과 관전류량을 사용하여 실제 skull X-ray 팬텀 영상을 획득하였다. 또한, 각각의 팬텀 영상에 noisy image, median filter, Wiener filter, TV 알고리즘을 적용하였을 때의 대조도 대 잡음비 (CNR)와 변동계수 (COV)를 비교 측정했다. 실험 결과 TV 알고리즘을 적용하였을 때, 모든 조건에서 CNR와 COV 특성이 우수함을 확인할 수 있었다. 결론적으로 이번 연구를 통해 TV 알고리즘을 사용하여 영상의 질을 높일 수 있는지에 대해 확인해 보았고, 이론적으로 CNR 값은 관전류량이 증가할수록 노이즈가 감소함으로 인해 증가하는 것을 알아볼 수 있었다. 반면에, COV는 관전류량이 증가할수록 감소하였으며 관전압이 증가하였을 때 noise는 감소하고 투과량이 증가하여 COV가 감소하는 것을 알아볼 수 있었다.