• Title/Summary/Keyword: skin incision

Search Result 247, Processing Time 0.02 seconds

Correction of High Fold without Skin Excision (피부 제거 없이 시행한 높은 쌍꺼풀의 교정)

  • Oh, Heung Chan;Yoon, Dong Ju;Kang, Cheol Uk;Choi, Chi Won;Choi, Soo Jong;Bae, Yong Chan
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.649-653
    • /
    • 2009
  • Purpose: Double - eyelid operation is one of the most common cosmetic operations among Korean patients. In such operations, however, the complexity of and individual differences in the patients' anatomical structures may cause various complications, such as asymmetry, retraction of the eyelid, and the occurrence of a high fold. A high fold occurs frequently, and its correction is not very simple. Many methods have been developed to correct it, and among these, the operation involving the excision of the skin between the previous double - eyelid line and the new double - eyelid line is usually selected by plastic surgeons. In many cases, however, patients have insufficient eyelid skins for this operation. In this study, the authors introduce an operation procedure for high - fold correction that does not involve skin excision Methods: From June 2005 to June 2009, 246 cases were treated with this procedure. After the incision of the new double - eyelid line, dissection was done between the previous scar tissue and the levator aponeurosis. Then the orbital septum, orbital fat or the retro - orbicularis oculi fat was slid down and sutured with a tarsal plate. Such sutures were repeated at four to five points, including the lateral and medial limbus, to prevent the reattachment of the previous scar and to create a new double - eyelid line at the end of the orbital septum. Results: Most of the high - fold patients were satisfied with the procedure described above. Their previous scar was hidden under the new double - eyelid line after the operation. In the six cases, the scar was visible in the patients who had a very high and deep inner line. As such, scar revision was undertaken three months after the operation. It is known that scar revision is also required after an operation involving skin excision in the case of a very high inner - eyelid line. Conclusion: This method is an appropriative procedure for high - fold correction for patients who have insufficient upper - eyelid skin.

Semicircular Horizontal Approach in Breast Reduction: Clinical Experience in 38 Cases

  • Shin, Hee Su;Lee, Yong Hae;Jung, Sung Gyun;Lee, Doo Hyung;Roe, Young;Cha, Jong Hyun
    • Archives of Plastic Surgery
    • /
    • v.42 no.4
    • /
    • pp.446-452
    • /
    • 2015
  • Background Various techniques are used for performing breast reduction. Wise-pattern and vertical scar techniques are the most commonly employed approaches. However, a vertical scar in the mid-lower breast is prominent and aesthetically less pleasant. In contrast, a semicircular horizontal approach does not leave a vertical scar in the mid breast and transverse scars can be hidden in the inframammary fold. In this paper, we describe the experiences and results of semicircular horizontal breast reductions performed by a single surgeon. Methods Between September 1996 and October 2013, our senior author used this technique in 38 cases in the US and at our institution. We used a superiorly based semicircular incision, where the upper skin paddle was pulled down to the inframammary fold with the nipple-areola complex pulled through the keyhole. Results The average total reduction per breast was 584 g, ranging from 286 to 794 g. The inferior longitudinal pedicle was used in all the cases. The average reduction of the distance from the sternal notch to the nipple was 13 cm (range, 11-15 cm). The mean decrease in the bra cup size was 1.7 cup sizes (range, a decrease of 1 to 3). We obtained very satisfactory results with a less noticeable scar, no complication such as necrosis of the nipple or the skin flap, wound infection, aseptic necrosis of the breast tissue, or wound dehiscence. One patient had a small hematoma that resolved spontaneously. Conclusions This technique is straightforward and easy to learn, and offers a safe, effective, and predictable way for treating mammary hypertrophy.

Transfibular Approach for Ankle and Tibiotalocalcaneal Arthrodesis (비골 외과 절제술을 통한 족관절 또는 경골거골종골간 관절고정술)

  • Chung, Young-Ki;Yoo, Jung-Han;Park, Yong-Wook;Kim, Jin-Sub;Pyo, Dong-Cheol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.1 no.1
    • /
    • pp.15-22
    • /
    • 1997
  • A variety of surgical approach for ankle and tibiotalocalcaneal arthrodesis has been described. We used a transfibular approach between the sural nerve and lateral branch of the superficial peroneal nerve. This permits excellent visualization of the ankle and subtalar joint so that the fusion can readily be achieved under the direct visualization. Eight ankle fusions and four tibiotalocalcaneal fusions were carried out through a transfibular approach and reviewed. The resected fibula was utilized for bone graft. The follow up period was from 12 to 22 months. Ages of the patients ranged from 27 to 58 years. The postoperative regimen was six weeks nonweight bearing in a short leg cast, followed by weight bearing in a short leg cast until union occurred. All cases were fused except one who had preoperative pyogenic arthritis of the ankle and hindfoot. The results were as follows; 1. The chance of incisional neuroma is lessened through incision between the sural nerve and superficial peroneal nerve. 2. The possibility of a skin slough is reduced by using full thickness skin flaps. 3. Excellent visualization of the ankle and subtalar joint is easily achieved. So, we believed that the transfibular approach for ankle and tibiotalocalcaneal arthrodesis is the excellent surgical approach.

  • PDF

Correction of Cryptotia by Triangular V-Y Advancement Flap and Rhomboid Flap (삼각형 V-Y피판 및 장사방형피판을 이용한 매몰귀의 교정)

  • Lee, Joon-Moon;Seo, Dong-Lin;Dhong, Eun-Sang;Yoon, Eul-Sik
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.639-643
    • /
    • 2010
  • Purpose: Cryptotia is a congenital deformity in which the upper third of the auricle is buried under the temporal skin. It is rare in Caucasians, yet it is more common in Asians. Although a variety of methods to treat cryptotia have been introduced, there is still no acceptable single procedure that can successfully manage this deformity in its entity. We present a triangular V-Y advancement flap and rhomboid flap for correcting cryptotia that can overcome the diverse shortcomings of the conventional methods. Methods: This operative method was used to correct 18 auricles in patients ranging in age from 4 to 33 years. A triangular flap was prepared over the auricle by making a skin incision according to Ohmori's method. Then a rhomboid flap with a side length of about 8 to 10 mm that sets the lower portion as a pedicle in the anterior region was prepared to supplement the contracted portion of the helix. The cartilage deformity was corrected by the banner flap or the radiating cartilage incisions with cartilage graft or high density polyethylene graft. Results: We have treated 16 patients with severe cryptotia using this method and have obtained good aesthetic results. All cases showed widened scaphoid fossa and smooth triangular fossa of antihelix. There were no major postoperative complications, such as necrosis or infection of the flaps. Conclusion: Correction of cryptotia using the triangular V-Y advancement flap and rhomboid flap is useful a method for certain conditions, when a severe contraction of the helix is present.

Correction of Cup Ear using the Mattress suture (매트리스봉합을 이용한 수축귀의 교정)

  • Jang, Soo Won;Lee, Jang Hyun;Choi, Seung Suk;Tak, Min Sung
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.118-121
    • /
    • 2009
  • Purpose: Constricted ear, which is named by Tanzer includes lop ear, cup ear, and sort of prominent ear. It has classified three groups by Tanzer, especially grou I and IIA have been corrected by banner flap, Musgrave's technique, tumbling concha - cartilage flap, reversed banner flap and others. However, these techniques were too invasive for correcting mild degree of deformity. Therefore, we corrected the ear with mattress suture which is simple and less invasive. Method: The operations were done against 5 patients from 2005 March to 2008 April. All the cases were unilateral ears with constriction included helix and scaphoid fossa without difference in length between both ears. Though a posterior auricular skin incision, the folded cartilage is exposed and two parallel incisions on superior crus were made. After mattress suturing in cartilage, the superior crus of antihelix was formed and its force enables the folded portion to be in a normal anatomic position. Result: All of 5 patients got satisfactory results. There were no complications like hematoma or skin necrosis, and no recurrence during follow - up period(the average period was 9 months). And we couldn't recognize the difference between height of both auricles. Conclusion: Mattress suture is simple, less invasive, and suitable on correcting mild deformity of constricted ear with better result, so here we suggest the method.

Changes in blood flow at the mandibular angle and Horner syndrome in a rat model of superior cervical ganglion block

  • Kubota, Kazutoshi;Sunada, Katsuhisa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.2
    • /
    • pp.105-110
    • /
    • 2018
  • Background: A stellate ganglion block (SGB) causes increased blood flow in the maxillofacial region, exhibiting the potential for regenerative effects in damaged tissue. The focus of this study was to understand the efficacy of SGB for regenerative effects against nerve damage. A rat model of the superior cervical ganglion block (SCGB) was created instead of SGB, and facial blood flow, as well as sympathetic nervous system function, were measured. Methods: A vertical incision was made on the left side of the neck of a Wistar rat, and a 5-mm resection of the superior cervical ganglion was performed at the back of the bifurcation of the internal and external branches of the left common carotid artery. Blood flow in the skin at the mandibular angle and mean facial temperature were measured using a laser-Doppler blood flow meter and a thermographic camera, respectively, over a 5-week period after the block. In addition, the degree of ptosis and miosis were assessed over a period of 6 months. Results: The SCGB rat showed significantly higher blood flow at the mandibular angle on the block side (P < 0.05) for 3 weeks, and significantly higher skin temperature (P < 0.05) for 1 week after the block. In the SCGB rat, ptosis and miosis occurred immediately after the block, and persisted even 6 months later. Conclusions: SCGB in rats can cause an increase in the blood flow that persists over 3 weeks.

Effects of Chitosan on Wound Healing in Pigs (돼지에서 창상치유에 대한 키토산의 영향)

  • Byun, Hong-Sub;Kim, Myung-Jin;Lee, Jae-Yeon;Cho, Sung-Whan;Park, Chang-Sik;Kim, Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.114-118
    • /
    • 2007
  • The objective of this study was to investigate the effects of implanted chitosan applied to surgically created wound in pigs. Six healthy $2{\sim}3$ months old Landrace and Yorkshire mixed breeds of both genders were used. A 2 cm straight skin incision was made and undermined skin ($2{\times}2cm$) over on the each pig's both sides of dorsal midline at 0, 7. 14 and 18 days. One wound (left side) was implanted 0.4 mg of cotton type chitosan and other wound was treated saline (3 ml). Each wound was closed with two interrupted suture of 2-0 sutures. The wounds created at 18, 14.7 and 0 days were named post-wounding day (PWD) 3, 7, 14 and 21, respectively. At 21 days after initial wounding, each wound was taken for histological observations. Reepithelialization tended to be greater in the chitosan group than in the control group at PWD 3 and 14. Granulation tissue formation did not show especial differences in two groups. Number of inflammatory cells was lesser statistically in level in the chitosan group than those in the control group at 21 days after wounding (p<0.05). Fibroblasts and neovasculature tended to be greater in the chitosan group than in the control group at PWD 3 and 7, and tended to be lesser in the chitosan group than in the control group at PWD 14 and 21. Collagen and fibrin were observed to be evenly distributed around the wound in the chitosan group. But collagen and fibrin were observed to be converged along the wound in the control group.

A New Facial Composite Flap Model (Panorama Facial Flap) with Sensory and Motor Nerve from Cadaver Study for Facial Transplantation (얼굴이식을 위한 운동과 감각신경을 가진 중하안면피판 모델(파노라마 얼굴피판)에 대한 연구)

  • Kim, Peter Chan Woo;Do, Eon Rok;Kim, Hong Tae
    • Archives of Craniofacial Surgery
    • /
    • v.12 no.2
    • /
    • pp.86-92
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the possibility that a dynamic facial composite flap with sensory and motor nerves could be made available from donor facial composite tissue. Methods: The faces of 3 human cadavers were dissected. The authors studied the donor faces to assess which facial composite model would be most practicable. A "panorama facial flap" was excised from each facial skeleton with circumferential incision of the oral mucosa, lower conjunctiva and endonasal mucosa. In addition, the authors measured the available length of the arterial and venous pedicles, and the sensory nerves. In the recipient, the authors evaluated the time required to anastomose the vessels and nerve coaptations, anchor stitches for donor flaps, and skin stitches for closure. Results: In the panorama facial flap, the available anastomosing vessels were the facial artery and vein. The sensory nerves that required anastomoses were the infraorbital nerve and inferior alveolar nerve. The motor nerve requiring anstomoses was the facial nerve. The vascular pedicle of the panorama facial flap is the facial artery and vein. The longest length was 78 mm and 48 mm respectively. Sensation of the donor facial composite is supplied by the infraorbital nerve and inferior alveolar nerve. Motion of the facial composite is supplied by the facial nerve. Some branches of the facial nerve can be anastomosed, if necessary. Conclusion: The most practical facial composite flap would be a mid and lower face flap, and we proposed a panorama facial flap that is designed to incorporate the mid and lower facial skin with and the unique tissue of the lip. The panorama facial composite flap could be considered as one of the practicable basic models for facial allotransplantation.

Short-term changes of human acellular dermal matrix (Megaderm) in a mouse model

  • Kim, Yang Seok;Na, Young Cheon;Yoon, Hyun Sik;Huh, Woo Hoe;Kim, Ji Min
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.1
    • /
    • pp.10-16
    • /
    • 2019
  • Background: Physicians tend to overcorrect when applying the acellular dermal matrix for reconstructive option because of volume decrement problem after absorption comparing with initial volume. However, there are no studies on the exact volume decrement and absorption rate with commercial products in South Korea. To figure out absorption rate of acellular dermal matrix product in South Korea (Megaderm), authors designed this experiment. Methods: Nine mice were used and randomly divided into three groups by the time with sacrificing. The implant (Megaderm) was tailored to fit a cuboid form ($1.0cm{\times}1.0cm$ in length and width and 2.0 mm in thickness). A skin incision was made at anterior chest with blade #15 scalpel with exposing the pectoralis major muscle. As hydrated Megaderm was located upon the pectoralis major muscle, the skin was sutured with Ethilon #5-0. After the surgical procedure, each animal group was sacrificed at 4, 8, and 12 weeks, respectively, for biopsies and histological analysis of the implants. All samples were stained with routine hematoxylin and eosin staining and Masson's trichrome staining and the thickness were measured. A measurements were analyzed using Friedman test. Statistically, the correlation between thicknesses of Megaderm before and after implantation was analyzed. Results: After sacrificing the animal groups at postoperative 4, 8, 12 weeks, the mean tissue thickness values were $2.10{\pm}1.03mm$, $2.17{\pm}0.21mm$, and $2.40{\pm}0.20mm$ (p= 0.368), respectively. The remaining ratios after absorption comparing with after initial hydrated Megaderm were 82.7%, 85.4%, and 94.5%, respectively. In histopathological findings, neovascularization and density of collagenous fiber was increased with time. Conclusion: Author's hypothesis was absorption rate of implant would be increased over time. But in this experiment, there is no statistical significance between mean absorption thickness of implant and the time (p= 0.368). Also it can be affected by graft site, blood supply, and animals that were used in the experiment.

DaVinci SP-based simultaneous bilateral partial nephrectomy from the midline transperitoneal approach: a case report

  • Young Hwii Ko;Jong Gyun Ha;Jae Yoon Jang;Yeung Uk Kim
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.1
    • /
    • pp.48-52
    • /
    • 2024
  • While simultaneous bilateral partial nephrectomy with a conventional multiport robot has been consistently reported since the 2010s, the introduction of the DaVinci SP system (Intuitive Surgical, Sunnyvale, CA, USA) could provide a novel way to perform surgery on bilateral kidneys while innovatively reducing the number of incisions. In our first report worldwide, the patient with bilateral small renal mass (2.0 cm for the left and 1.5 cm for the right side) and preoperative normal renal function was placed in the lateral decubitus position on an inverted bed. After tilting the bed to be as horizontal as possible, a 4-cm incision was made in the lower part of the umbilicus for the floating trocar technique. The partial nephrectomy was performed reliably as with the conventional transperitoneal approach, and then the patient could be repositioned to the contralateral side for the same procedure, maintaining all trocars. Total operation time (skin to skin), total console time, and the left- and right-side warm ischemic times were 260, 164, 27, and 23 minutes, respectively, without applying the early declamping technique. The estimated blood loss was 200 mL. The serum creatinine right after the operation, on the first day, 3 days, and 90 days after surgery were 0.92, 0.77, 0.79, and 0.81 mg/dL, respectively. For 90 days after the procedure, no complications or radiologic recurrence were observed. Further clinical studies will reveal the advantages of using the DaVinci SP device for this procedure over traditional multiport surgery, maximizing the benefit of a single port-based approach.