• Title/Summary/Keyword: site period

Search Result 2,639, Processing Time 0.029 seconds

Verification of 2-Parameters Site Classification System and Site Coefficients (I) - Comparisons with Well-known Seismic Code and Site Response Characteristics (2-매개변수 지반분류 방법 및 지반 증폭계수의 검증 (I) - 국외 내진설계기준 및 부지응답특성과의 비교)

  • Lee, Sei-Hyun;Sun, Chang-Guk;Ha, Jeong-Gon;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.3
    • /
    • pp.25-34
    • /
    • 2012
  • In order to verify that the recently proposed two-parameters site classification system and the corresponding site coefficients are suitable for the local geological conditions in Korea, a comparison was conducted with current Korean seismic code, Eurocode-8, NYC DOT seismic code. The design spectrum of the current Korean seismic code is significantly amplified in the long-period range, whereas the other response spectra, including the proposed two-parameters approach, are significantly amplified in the short-period range, which is a typical geological condition in Korea. In addition, based on the results of site response analyses in the specific $10km{\times}10km$ area of Gyeongju, spatial distributions of site coefficients from site-specific seismic response analyses were compared with the proposed site coefficients, as well as those specified in the current Korean seismic code. The site coefficients ($F_a$ and $F_v$) from the current Korean seismic codes show significantly high spatial error distributions compared with those specified by the two-parameters site classification system. Therefore, the proposed system is suitable for regions of shallow bedrock including the Korean peninsula.

Physicochemical Properties of Landfill Mined Wastes from Old Landfill Site (불량 매립지에서 굴착된 폐기물의 물리화학적 특성평가)

  • 남궁완;이노섭;박준석;인병훈
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.99-108
    • /
    • 2002
  • This study was carried out to evaluate the Physicochemical characteristics of mined waste(separated waste and soil) and to predict environmental effect of an old landfill site located at north of Seoul. Municipal solid waster(MSW) had been disposed of at the old landfill site used in this study for about 2 years(1990-1992). The old landfill site selected for this study had accepted mainly municipal solid waste. The landfill-mined waste contained separated waste (40.9%) and soil(59.1%) by wet weight basis. The separated waste consisted of combustible(91.0%) and non-combustible(9.0%). The combustible waste was mainly non-biodegradable plastics. The low heating value of the separated combustible waste, which is calculated by Dulong's equation, was as high as 3,470kcal/kg. According to the Korean Extraction Procedure, separated waste and soil were proved to be not hazardous. The total content of heavy metal in the separated waste and soil met standard of California State, USA. Therefore the separated waste may be relandfilled at a sanitary landfill site and/or burned up at an incinerator, and the separated old soil may be used ad landfill cover-soil at a sanitary landfill site. Water quality of two streams was grade IV, of which water could be used as industrial and agricultural water. The streams near the landfill site might not be contaminated by leachate from the old landfill site. It was estimated that organic matter in the old landfill site would not be actively biodegraded within a short period of time.

Assessment of Response Spectrum by Dynamic Centrifuge Test for the Pile Foundation into the Sand (동적 원심모형실험에 의한 사질토에 근입된 말뚝지지 기초의 응답 스펙트럼 분석)

  • Park, Yong-Boo;Park, Jong-Bae;Kim, Sang-Yeon;Kim, Dong-Soo
    • Land and Housing Review
    • /
    • v.5 no.1
    • /
    • pp.35-40
    • /
    • 2014
  • Site coefficient and amplification factor of current domestic Seismic Design Code (KBC-2009) have no consideration for the domestic ground condition in which the base rock is normally placed within 30m form the surface. Accordingly, in this study dynamic centrifugal test and analysis for pile foundation into sand and upper structure were achieved. and the response spectrums of free surface and basement were compared with each other. Within the period 1 sec., the measured spectral acceleration of free surface and basement was bigger than the design spectral acceleration of SC and SD site. However the measured spectral acceleration of free surface and basement for the period over 1.5 sec. was smaller than the design spectral acceleration of SC site. There was no severe difference of spectral acceleration according to the upper structure, embedded depth of foundation and free surface conditions. Consequently, normal domestic apartment housing for the period range over 1.5sec. could be design more economically applying these test result.

The Usefulness of the Anterolateral Thigh flap for Reconstructing Soft Tissue Defects (연부조직결손의 재건을 위한 전외측 대퇴부 피판술의 유용성)

  • Lee, Chung-Hoon;Jo, Jae-Yun;Chung, Duke-Whan;Lee, Jae-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.2
    • /
    • pp.117-124
    • /
    • 2005
  • Purpose: To present our experience and design modification of an anterolateral thigh flap in soft tissue reconstruction. Materials and Methods: Between April of 2004 and May of 2005, 26 anterolateral thigh flaps were used in 26 patients. There were 22 males and 4 females between 23 and 60 years (mean, 40years). The mean follow-up period was 11($4{\sim}18$) months. All cases were a cutaneous flap. Twenty-two were musculocutaneous perforator flaps(85%) and 4 were septocutaneous perforator flaps(15%). Four flaps were used as a sensate flap. While the donor sites were closed directly in 14 cases(54%), 12 cases(46%) underwent skin grafting of the donor site. During the flap design, a triangular skin design was added to a vascular anastomosis site in 14(54%) patients and used as a roof of the tunnel. The healing period of the skin graft between those performed above the fascia and above the muscle were compared. Results: The average size of the flaps was $16{\times}9(11-20{\times}7-12)\;cm$. The overall flap success rate was 96%. Complications encountered were infection in 4 cases, and marginal skin necrosis in 1 case. The healing period was delayed with the infection in 3 of the 6 cases involving a skin graft over the fascia. All 14 cases with the triangular skin design survived, but there was 1 flap failure and 1 marginal necrosis in 12 cases without a triangular skin design. Conclusions: It may be better to undergo a skin graft above the muscle than above the fascia in covering a donor site defect, and to use a triangular skin design in order to prevent vascular insufficiency. An anterolateral thigh flap is a versatile flap for a soft tissue reconstruction because its thickness and volume can be adjusted to the extent of the defect with minimal donor site morbidity.

  • PDF

Factors Related to Surgical Site Infections in Patients Undergoing General Surgery (일반외과 환자의 수술부위 감염 관련 요인 분석)

  • Ahn You-Jin;Sohng Kyeong-Yae
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.12 no.1
    • /
    • pp.113-120
    • /
    • 2005
  • Purpose: To identify risk factors for surgical site infections in patients undergoing general surgery, to analyze the prolonged hospital stay and extra cost for antibiotics, and to provide basic data for control of surgical site infections. Method: Surgical site infection was defined using the definition of the CDC and the data were analyzed by $x^2$-test and unpaired t-test. Results: The prevalence of surgical site infections was 9.7%, and it was related to wound class, duration of operation, number of operations, whether the operation was an emergency, trauma, drains, preoperative stays, presence of remote infection during operative period, and previous history of recent surgery. The mean duration for post-operative stay when a surgical site infection occurred was 9.5 days and in 56.9 % of the patients the surgical site infection appeared 7 days after the operation. Post-operative stays for infected patients were 20.3 days longer than that of uninfected patients. The mean cost of antibiotics for infected patients was higher than that for uninfected patients by 561,067 won per person. Conclusion: Surgical site infection results in an increased length of stay and extra-cost, thus, hospitals need to create strategies to reduce nosocomial infections through effective infection surveillance and by considering factors related to surgical site infections.

  • PDF

Efficacy of Quilting Sutures and Fibrin Sealant Together for Prevention of Seroma in Extended Latissimus Dorsi Flap Donor Sites

  • Shin, In Soo;Lee, Dong Won;Lew, Dae Hyun
    • Archives of Plastic Surgery
    • /
    • v.39 no.5
    • /
    • pp.509-513
    • /
    • 2012
  • Background The extended latissimus dorsi flap is important for breast reconstruction. Unfortunately, donor site seroma is the most common complication of extended latissimus dorsi flap for breast reconstruction. Although using fibrin sealant in the donor site reduces the rate of seroma formation, donor site seroma remains a troublesome complication. The purpose of this study was to analyze the effectiveness of the combination of quilting sutures and fibrin sealant in the latissimus dorsi donor site for the prevention of seroma. Methods Forty-six patients who underwent breast reconstruction with extended latissimus flap were enrolled in the study. The patients received either fibrin sealant (group 1, n=25) or a combination of fibrin sealant and quilting sutures (group 2, n=21) in the extended latissimus dorsi donor site. Outcome measures were obtained from the incidence, volume of postoperative seroma, total drainage amount, indwelling period of drainage, and duration of hospital stay. Results The incidence of seroma was 76% in group 1 and 42.9% in group 2 (P=0.022). We also found significant reductions in seroma volume (P=0.043), total drainage amount (P=0.002), indwelling period of drainage (P=0.01), and frequency of aspiration (P=0.043). The quilting sutures did not affect the rate of drainage, tube reinsertion, or hospital stay. Conclusions The use of quilting sutures combined with fibrin sealant on the latissimus dorsi flap donor site is helpful for reducing the overall seroma volume, frequency of aspiration, and total drainage amount.

Investigation of Lead Isotope Ratios on Lead Artifacts Excavated from Mireuk Temple Site, Iksan (익산 미륵사지 출토 납제품의 납동위원소비 분석 고찰)

  • No, Ji-Hyun;Hirao, Yoshimitsu;Kim, Gyu-Ho;Noh, Gi-Hwan
    • 보존과학연구
    • /
    • s.30
    • /
    • pp.137-147
    • /
    • 2009
  • Mireuk temple site is located in Iksan, on the North Jeolla province in Korea, and confirmed tiles, potteries, metals, glasses and other materials that are remaining between Baekje Kingdom and Joseon period after excavations. It is also detected that production and supply of the materials in this era were started inside the country(domestic) at that time. This is important information for the understanding of the production and circulation systems. In this study, lead isotope ratios of 18 samples includedlead glass, crucibles and glazed rafter tiles excavated from Mireuk Temple Site of Baekje era were analyzed for the provenance study of raw glass material supply and distribution of glass products. The results of lead isotope ratio analysis have shown that all raw materials were located in the distribution area of Baekje region and also confirmed to be accord with the previous research results. As comparing the lead isotope ratios of glass and glass materials excavated from Mireuk Temple Site with Miyajidake tomb from Fukuoka Prefecture in Japan, it is found that the same raw materials were used for glass production. It means that there is the active connection between Mireuk temple site and Miyajidake and that these areas are sharing the same materials at the same period. It also shown that artifacts excavated from Miyajidake were strongly influenced from Baekje culture. And it is estimated that there is a possibility of the use ofsame materials whether the supplies of them are from a specific place of Baekje or not

  • PDF

Site-Plan Types of Common Design's Goon Office Buildings and their Addition & Remodeling in Japanese Colonial Period (일제강점기 '공통형' 군청사의 배치 유형과 유형별 증·개축 경향)

  • Kim, Myungsun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7629-7634
    • /
    • 2015
  • The purpose of this study is is to organize the site-plan types of common design's Goon office buildings in Japanese colonial period based on the main building's shape and main & attached building connection way and to investigate all the types' addition & remodeling ways. The study used literature research method, analysing the digital images, the annotation of the images, official documents between the Japanese government-general of Korea and To, and articles of newspapers or journals. The site-plans are sorted 5 types and subdivided 13 as their addition & remodelling ways. The initial shapes of site-plan were changed to apply every Goon's site circumstances, The main buildings were always in the center ahead and attached buildings behind or next to them in any cases of new construction, addition or remodeling. The buildings of the common design's were constructed until early 1930s and it means that their architectural level was lower than Pu office buildings, although both had same administrational level.

An Experimental Study on Strength Properties of Early Strength Concrete for Reduction of Working Period in Apartment (공동주택 공기단축을 위해 개발된 조강 콘크리트의 강도 발현 특성에 관한 연구)

  • Jung, Yang-Hee;Lee, Jae-Hyun;Keum, Kyoung-Hun;Lee, Won-AM;Kim, Sun-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.157-160
    • /
    • 2009
  • The decision of the Form removal time which leads the early assuring strength of the concrete from Apartment construction is the fact which is important from Reducing the period of works and the economical efficiency side. Especially, with Complex building of recent times the same Tall building and Multiple Apartment Site which only follows in upgrade of interior construction of apartment site and shortening the frame construction period becomes very, importantly is the actual condition where the effort which is various for this is attempted. But is caused by with limit and economical efficiency problem of case concrete early strength revelation of most and is not put to practical use is the actual condition. Develops concrete mixture which is a utility from the research which sees hereupon and the effect which is economic leads construction duration shortening under maximizing boil.

  • PDF

Regional Estimation of Site-specific Seismic Responses at Gyeongju by Building GIS-based Geotechnical Information System (GIS 기반의 지반 정보 시스템 구축을 통한 경주 지역 부지고유 지진 응답의 지역적 평가)

  • Sun, Chang-Guk;Chung, Choon-Ki
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.2
    • /
    • pp.38-50
    • /
    • 2008
  • The site-specific seismic responses and corresponding seismic hazards are influenced mainly by the subsurface geologic and geotechnical dynamic characteristics. To estimate reliably the seismic responses in this study, a geotechnical information system (GTIS) within GIS framework was developed by introducing new concepts, which consist of the extended area containing the study area and the additional site visit for acquiring surface geo-knowledge data. The GIS-based GTIS was built for Gyeongju area, which has records of abundant historical seismic hazards reflecting the high potential of future earthquakes. At the study area, Gyeongju, intensive site investigations and pre-existing geotechnical data collections were performed and the site visits were additionally carried out for assessing geotechnical characteristics and shear wave velocity ($V_S$) representing dynamic property. Within the GTIS for Gyeongju area, the spatially distributed geotechnical layers and $V_S$ in the entire study area were reliably predicted from the site investigation data using the geostatistical kriging method. Based on the spatial geotechnical layers and $V_S$ predicted within the GTIS, a seismic zoning map on site period ($T_G$) from which the site-specific seismic responses according to the site effects can be estimated was created across the study area of Gyeongju. The spatial $T_G$ map at Gyeongju indicated seismic vulnerability of two- to five-storied buildings. In this study, the seismic zonation based on $T_G$ within the GIS-based GTIS was presented as regional efficient strategy for seismic hazard prediction and mitigation.

  • PDF