• Title/Summary/Keyword: sinus lift

Search Result 63, Processing Time 0.02 seconds

PERI-IMPLANTITIS : TWO YEARS RETROSPECTIVE STUDY (임프란트 주위염)

  • Jeon, Woo-Jin;Kim, Su-Gwan;Ha, Jeong-Wan;Kim, Moon-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.257-260
    • /
    • 2003
  • The purpose of the present study lied in examining the incidence, treatment and failure causes of peri-implantitis by analyzing medical charts of those patients who underwent implant placement for the past 2 years. The subjects included those patients who underwent implant placement at the present hospital from January 2001 to December 2002. 3i implants were used for the analysis for the comparison of significance. A total of 301 patients were examined, among whom 102 were females and 199, males. Implants were placed in a total of 578 cases. The number of peri-implantitis was present in a total of 29 cases (21 males and 8 females), giving the incidence at 9.6%. The evidence of peri-implantitis was seen in 60 cases, which was in 10.4% of the patients. Among those cases with peri-implantitis, 28 cases (47%) underwent bone graft and 22 cases (43%) underwent maxillary sinus lift. Furthermore, 4 of these patients had systemic diseases such as diabetes or hypertension. Regular management is important for the prevention of peri-implantitis. In other words, early prevention through regular follow-ups to check the status of surrounding soft tissue would be needed to maintain implants.

Retrospective clinical study of an implant with a sandblasted, large-grit, acid-etched surface and internal connection: analysis of short-term success rate and marginal bone loss

  • Lee, Jae-Wang;An, Jun Hyeong;Park, Sang-Hoon;Chong, Jong-Hyon;Kim, Gwang-Seok;Han, JeongJoon;Jung, Seunggon;Kook, Min-suk;Oh, Hee-Kyun;Ryu, Sun-Youl;Park, Hong-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.42.1-42.7
    • /
    • 2016
  • Background: The purpose of this retrospective study was to evaluate the clinical utility of an implant with a sandblasted, large-grit, acid-etched (SLA) surface and internal connection. Methods: Six patients who received dental implants in the Department of Oral and Maxillofacial Surgery, Chonnam National University Dental Hospital, were analyzed by factors influencing the success rate and marginal bone loss. Factors included patient's age, sex, implant installation site, whether bone graft was done, type of bone graft materials, approaching method if sinus lift was done, and the size of the fixture. In addition, the marginal bone loss was analyzed by using a radiograph. Results: All implants were successful, and the cumulative survival rate was 100 %. Average marginal bone loss of 6 months after the installation was 0.52 mm and 20 months after the functional loading was 1.06 mm. Total marginal bone resorption was 1.58 mm on average. There was no statistically significant difference in mesial and distal marginal bone loss. Conclusions: The short-term clinical success rate of the implant with an SLA surface and internal connection was satisfactory. Moreover, the marginal bone loss was also consistent with the implant success criteria.

A COMPARATIVE STUDY OF VARIOUS TYPE OF AUTOGENEOUS BONE GRAFT ON THE RABBIT-SKULL DEFECT HEALING (가토 두개골에 이식한 다양한 형태의 자가골에 의한 골성 회복 양상 비교 평가)

  • Choi, So-Young;Lee, Su-Youn;Kim, Jin-Wook;Kim, Chin-Soo;Lee, Sang-Han;Shin, Hong-In;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.4
    • /
    • pp.428-434
    • /
    • 2008
  • Introduction: Piezosurgery device is one of the most commonly used instrument on the intraoral surgery such as maxillary sinus lift and autogeneous bone graft. Piezosurgery instrument also contains the tips that are manufactured especially for the convenient bone graft, which now many surgeons apply them for collecting bone graft materials in the curettage method for the restoration of skull defects. However, objective data has not been shown concerning the effects about bone graft with using Piezosurgery. Therefore we investigated the effects of Piezosurgery on the rabbit-skull defect healing. Materials & Methods: To investigate the regeneration of the bony defect with various bone graft, 10 adult New Zealand white rabbits (average weight : $2.8{\pm}0.3kg$, about 12weeks) were used. The four circular bony defects measuring 6mm in diameter were made with Piezosurgery device on each rabbit cranial bone. The harvested bone tissues during defect formation were also used for autogeneous bone graft. They were grafted into the defects in a various type; block type (Group 1), particulated type by the bone mill (Group 2), chopped type by curette shaped Piezosurgery tip (Group 3), the defect without any graft was served as control (control group). The animals were sacrificed after 6 weeks and bone regeneration capacity was evaluated histomorphometrically. Result & Conclusion: Autogeneous bone graft harvested using a Piezosurgery instrument showed satisfactory bone regeneration. There was no conspicuous difference bone prepared among by bone mill or Piezosurgery and block bone graft. Therefore, the bone harvested from the intraoral site near the operation field using the piezosurgery device can be a feasible and reliable graft for intraoral bony defects.