• Title/Summary/Keyword: single-lead

Search Result 854, Processing Time 0.024 seconds

Appropriate Package Structure to Improve Reliability of IC Pattern in Memory Devices (메모리 반도체 회로 손상의 예방을 위한 패키지 구조 개선에 관한 연구)

  • 이성민
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.32-35
    • /
    • 2002
  • The work focuses on the development of a Cu lead-frame with a single-sided adhesive tape for cost reduction and reliability improvement of LOC (lead on chip) package products, which are widely used for the plastic-encapsulation of memory chips. Most of memory chips are assembled by the LOC packaging process where the top surface of the chip is directly attached to the area of the lead-frame with a double-sided adhesive tape. However, since the lower adhesive layer of the double-sided adhesive tape reveals the disparity in the coefficient of thermal expansion from the silicon chip by more than 20 times, it often causes thermal displacement-induced damage of the IC pattern on the active chip surface during the reliability test. So, in order to solve these problems, in the resent work, the double-sided adhesive tape is replaced by a single-sided adhesive tape. The single-sided adhesive tape does net include the lower adhesive layer but instead, uses adhesive materials, which are filled in clear holes of the base film, just for the attachment of the lead-frame to the top surface of the memory chip. Since thermal expansion of the adhesive materials can be accommodated by the base film, memory product packaged using the lead-flame with the single-sided adhesive tape is shown to have much improved reliability. Author allied this invention to the Korea Patent Office for a patent (4-2000-00097-9).

  • PDF

Fixed bed column modeling of lead(II) and cadmium(II) ions biosorption on sugarcane bagasse

  • Vera, Luisa Mayra;Bermejo, Daniel;Uguna, Maria Fernanda;Garcia, Nancy;Flores, Marittza;Gonzalez, Enrique
    • Environmental Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.31-37
    • /
    • 2019
  • In this paper the results of the biosorption of lead(II) and cadmium(II) with sugarcane bagasse in fixed bed columns are presented. Experimental data were fitted to several models describing the rupture curve for single-component and two-component systems. The percentages of removal of lead and cadmium in single-component systems are 91% and 90%, respectively. In lead-cadmium bicomponent systems the percentage of elimination of lead was 90% and cadmium 92%. In single-component systems, Yoon-Nelson and Thomas models successfully reproduce the rupture curves. In two-component system, the Dose-Response model was the best one reproducing the experimental rupture curves in the entire measured range.

An Empirical Study on Trade Facilitation by the Korean Government's Single Window System

  • Cheolkyu Maeng
    • Journal of Korea Trade
    • /
    • v.27 no.1
    • /
    • pp.101-118
    • /
    • 2023
  • Purpose - Korea became a trillion-dollar trading country in 2011. With the exponential increase in Korea's trade volume over the past decades, trade-related administrative burdens per capita for Korea Customs became enormous, for which the government established the Single Window, a trade-facilitating system, in 2004 to enhance the efficiency of customs-clearing procedures for traders. This paper focuses on finding whether the Korean Single Window system affects the country's trade facilitation positively through an empirical methodology. Design/methodology - To find empirical evidence that Single Window affects trade facilitation for the customs-clearing procedure, this study assumes that a time-efficient environment enables the handling of the increase in trade volume, under which four independent variables related to import customs-clearing procedures and two dependent variables to import were adopted for empirical analysis. The import customs procedures are classified into four steps from port entry to declaration acceptance. To understand the relationship between variables, scattered plots and correlation coefficients were calculated. Eight hypotheses were set and underwent simple linear regression. The data for analysis were collected by Korea Customs, and were about the lead time of import, the volume of imports in million USD, and the number of import declarations reported to customs offices on a monthly basis from 2005 to 2013. Findings - Six of the eight hypotheses showed the statistically significant result that lead time in the import customs-clearing procedure positively affects the number of import declaration reports and import volume. Specifically, Hypothesis 1, Hypothesis 2, and Hypothesis 3 strongly support the assumption lead time in import customs declaration has an inverse relationship with the number of import declarations, which means that the shorter the import lead time, the more import declaration increases. Research Limitations/Implications - With limited data accessibility to the government's custom-sclearing procedures, only the import lead time for customs clearance were adopted as independent variables. This paper, however, successfully found that the Single Window system contributed to trade facilitation. Originality/value - This study found that the time-saving Single Window system of Korea Customs enables itself to manage an exponentially-increasing trade volume by creating a trade-facilitating environment for customs personnel and traders, which may be a unique implication found through quantitative methodology.

Mechanical Performance Comparison of Pedicle Screw Based on Design Parameters: Dual Lead and Dual Pitch (척추경 나사못의 디자인이 고정력 및 구동 토크에 미치는 영향 분석: 이중 나사 및 이중 피치 나사)

  • Choi, Sun-Gak;Cha, Eun-Jong;Kim, Kyung-Ah;Ahn, Yoon-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.134-139
    • /
    • 2018
  • One of the most common problems with pedicle screw system is pullout of the screw. This study was performed to evaluate the pullout strength and driving torque of newly designed pedicle screws. The design of three type screws were standard pedicle screw, which had single lead threaded and single pitched design (Type A), single pitched and dual lead threaded pedicle screw (Type B), dual pitched and dual lead threaded pedicle screw (Type C), respectively. The tests were performed in accordance with the ASTM standards using polyurethane (PU) foam blocks. There was no significant difference in pullout strength among three types of screw. Type B and Type C exhibited higher insertion torque and removal torque than Type A, respectively (p<0.05). Pedicle screws newly developed with dual pitched and dual lead threaded design showed higher driving torque without decrease in pullout strength compared to the standard pedicle screw and could be inserted more rapidly with the same number of revolutions.

Identification of Individuals using Single-Lead Electrocardiogram Signal (단일 리드 심전도를 이용한 개인 식별)

  • Lim, Seohyun;Min, Kyeongran;Lee, Jongshill;Jang, Dongpyo;Kim, Inyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.3
    • /
    • pp.42-49
    • /
    • 2014
  • We propose an individual identification method using a single-lead electrocardiogram signal. In this paper, lead I ECG is measured from subjects in various physical and psychological states. We performed a noise reduction for lead I signal as a preprocessing stage and this signal is used to acquire the representative beat waveform for individuals by utilizing the ensemble average. From the P-QRS-T waves, features are extracted to identify individuals, 19 using the duration and amplitude information, and 16 from the QRS complex acquired by applying Pan-Tompkins algorithm to the ensemble averaged waveform. To analyze the effect of each feature and to improve efficiency while maintaining the performance, Relief-F algorithm is used to select features from the 35 features extracted. Some or all of these 35 features were used in the support vector machine (SVM) learning and tests. The classification accuracy using the entire feature set was 98.34%. Experimental results show that it is possible to identify a person by features extracted from limb lead I signal only.

Comparison of Novel Telemonitoring System Using the Single-lead Electrocardiogram Patch With Conventional Telemetry System

  • Soonil Kwon;Eue-Keun Choi;So-Ryoung Lee;Seil Oh;Hee-Seok Song;Young-Shin Lee;Sang-Jin Han;Hong Euy Lim
    • Korean Circulation Journal
    • /
    • v.54 no.3
    • /
    • pp.140-153
    • /
    • 2024
  • Background and Objectives: Although a single-lead electrocardiogram (ECG) patch may provide advantages for detecting arrhythmias in outpatient settings owing to user convenience, its comparative effectiveness for real-time telemonitoring in inpatient settings remains unclear. We aimed to compare a novel telemonitoring system using a single-lead ECG patch with a conventional telemonitoring system in an inpatient setting. Methods: This was a single-center, prospective cohort study. Patients admitted to the cardiology unit for arrhythmia treatment who required a wireless ECG telemonitoring system were enrolled. A single-lead ECG patch and conventional telemetry were applied simultaneously in hospitalized patients for over 24 hours for real-time telemonitoring. The basic ECG parameters, arrhythmia episodes, and signal loss or noise were compared between the 2 systems. Results: Eighty participants (mean age 62±10 years, 76.3% male) were enrolled. The three most common indications for ECG telemonitoring were atrial fibrillation (66.3%), sick sinus syndrome (12.5%), and atrioventricular block (10.0%). The intra-class correlation coefficients for detecting the number of total beats, atrial and ventricular premature complexes, maximal, average, and minimal heart rates, and pauses were all over 0.9 with p values for reliability <0.001. Compared to a conventional system, a novel system demonstrated significantly lower signal noise (median 0.3% [0.1-1.6%] vs. 2.4% [1.4-3.7%], p<0.001) and fewer episodes of signal loss (median 22 [2-53] vs. 64 [22-112] episodes, p=0.002). Conclusions: The novel telemonitoring system using a single-lead ECG patch offers performance comparable to that of a conventional system while significantly reducing signal loss and noise.

Dielectric and Piezoelectric Properties of "Lead-free" Piezoelectric Rhombohedral Ba(Ti0.92Zr0.08)O3 Single Crystals

  • Lee, Jong-Yeb;Oh, Hyun-Taek;Lee, Ho-Yong
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.2
    • /
    • pp.171-177
    • /
    • 2016
  • Rhombohedral $Ba(Ti_{0.92}Zr_{0.08})O_3$ single crystals are fabricated using the cost-effective solid-state single crystal growth (SSCG) method; their dielectric and piezoelectric properties are also characterized. Measurements show that (001) $Ba(Ti_{0.92}Zr_{0.08})O_3$ single crystals have an electromechanical coupling factor ($k_{33}$) higher than 0.85, piezoelectric charge constant ($d_{33}$) of about 950 [pC/N], and piezoelectric voltage constant ($g_{33}$) higher than 40 [${\times}10^{-3}Vm/N$]. Especially the $d_{33}$ of (001) $Ba(Ti_{0.92}Zr_{0.08})O_3$ single crystals was by about six times higher than that of their ceramics. Because their electromechanical coupling factor ($k_{33}$) and piezoelectric voltage constant ($d_{33}$, $g_{33}$) are higher than those of soft PZT ceramics, it is expected that rhombohedral (001) $Ba(Ti_{0.92}Zr_{0.08})O_3$ single crystals can be used as "lead-free" piezoelectric materials in many piezoelectric applications such as actuator, sensor, and transducer.

Synthesis and Characterization of Bandgap-modulated Organic Lead Halide Single Crystals

  • Park, Dae Young;Byun, Hye Ryung;Lee, A Young;Choi, Ho Min;Lim, Seong Chu;Jeong, Mun Seok
    • Journal of the Korean Physical Society
    • /
    • v.73 no.11
    • /
    • pp.1716-1724
    • /
    • 2018
  • Single crystal of organic lead halide ($CH_3NH_3PbX_3$; $CH_3NH^+_3$ = methylammonium (MA), $X=Cl^-$, $Br^-$, $I^-$) is the best candidate for material intrinsic property studies due to no grain boundary and high crystal quality than the film having a lot of grain boundary and surface defects. The representative crystallization methods are inverse temperature crystallization (ITC) and anti-solvent vapor assisted crystallization (AVC). Herein, we report bandgap modulated organic lead halide single crystals having a bandgap ranging from ~ 2.1 eV to ~ 3 eV with ITC and AVC methods. The bandgap modulation was achieved by controlling the solvents and chloride-to-bromide ratio. Structural, optical and compositional properties of prepared crystals were characterized. The results show that the crystals synthesized by the two crystallization methods have similar properties, but the halide ratios in the crystals synthesized by the AVC method are controlled more quantitatively than the crystals synthesized by ITC.

Single-particle Characterization of Aerosol Particles Collected Nearby a Lead Smelter in China

  • Jung, Hae-Jin;Song, Young-Chul;Liu, Xiande;Li, Yuwu;Ro, Chul-Un
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.2
    • /
    • pp.83-95
    • /
    • 2012
  • China has been a top producer and exporter of refined lead products in the world since the year 2000. After the phasing-out of leaded gasoline in the late 1990s, non-ferrous metallurgy and coal combustion have been identified as potential major sources of aerosol lead in China. This paper presents the single particle analytical results of ambient aerosol particles collected near a lead smelter using a scanning electron microscopy- energy dispersive x-ray spectroscopy (SEM-EDX). Aerosol particle samples were collected over a 24-hour period, starting from 8 pm on 31 May 2002, using a high volume TSP sampler. For this near source sample, 73 particles among 377 particles analyzed (accounting for 19.4%) were lead-containing particles mixed with other species (S, Cl, K, Ca, and/or C), which probably appeared to be from a nearby lead smelter. Lead-containing particles of less than $2{\mu}m$ size in the near source sample were most frequently encountered with the relative abundances of 42%. SEM-EDX analysis of individual standard particles, such as PbO, PbS, $PbSO_4$, $PbCl_2$, and $PbCO_3$, was also performed to assist in the clear identification of lead-containing aerosol particles. Lead-containing particles were frequently associated with arsenic and zinc, indicating that the smelter had emitted those species during the non-ferrous metallurgical process. The frequently encountered particles following the lead-containing particles were mineral dust particles, such as aluminosilicates (denoted as AlSi), $SiO_2$, and $CaCO_3$. Nitrate- and sulfate-containing particles were encountered frequently in $2-4{\mu}m$ size range, and existed mostly in the forms of $Ca(NO_3,SO_4)/C$, $(Mg,Ca)SO_4/C$, and $AlSi+(NO_3,SO_4)$. Particles containing metals (e.g., Fe, Cu, and As) in this near source sample had relative abundances of approximately 10%. Although the airborne particles collected near the lead smelter contained elevated levels of lead, other types of particles, such as $CaCO_3$-containing, carbonaceous, metal-containing, nitrates, sulfates, and fly-ash particles, showed the unique signatures of samples influenced by emissions from the lead smelter.

Effect of Cadmium and Lead with Single or Mixed Admin stration on Rat Bones (카드뮴 및 납의 수여가 백서골성분에 미치는 영향)

  • 김영환;박국환
    • Journal of Environmental Health Sciences
    • /
    • v.8 no.1
    • /
    • pp.55-60
    • /
    • 1982
  • This study was carried out in order to clarify the combined effect of cadmium and lead on rat bones when exposed to single metal (1 mg cd/kg body weight) and cambined metals (1 mg cd + 4 mg pb/kg body weight). Seventy five mature rats of Sprague-Dawley species were divided into a control group and a treatment group that were administered by daily peritoneum injection for 7 to 9 weeds, and their body weights were measured every week. The results were summarized as follows 1. Body weight gains of the combined injection group and the single injection groups were lower than that of the control group. 2. In case of the combined injection group, the amount of cadmium accumulated in femur was more than that of the cadmium group. These amounts of cadmium accumulated showed an increasing trend. 3. The lead amount in bone tissue of the combined injection group presented also an increasing trend. In this case, the additive action of cadmium to the lead accumulation in bone tissue was conspicuous. 4. The amounts of calcium and phosphorus in femur showed clear a decreasing trend in the cadmium group and combined administration group. The ratio of calcium and phosphorus (ca/p) in the cadmium group was not different from that of the control group, but in the combined injection group the ratio was a little lower.

  • PDF