• Title/Summary/Keyword: single unit

Search Result 1,803, Processing Time 0.029 seconds

The Study to Derive Empirical Formula of Rainfall Intencity in Korea (한국에 있어서 강우강도의 효과에 관한 연구)

  • 박성우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.2
    • /
    • pp.1644-1650
    • /
    • 1969
  • In the design of general hydrological structures, it is well know that the design flood is of importance in the design of those structures. As the design flood is estimated using the design storm, the design storm is defined by the rainfall intensity itself. Though I had studied and reported many times the reports about the rainfall-intensity in my country, poorly I did not study the long-period variation of the intensity through each section in my country before. But now, in the basin area of the Han river and the Keum river, the self-recorded rainfall charts of the single storms, which are mostly above rainfall amount of 30mm and data of about 4500 with the 150 stationyear, were analyzed, And then, the intensity formula of the hourly unit is estimated using the period from 10 minutes to 5 days. The method to analyze and estimate them, and the final results will be summarized as mentioned below: (i) At first I intended to select out the homogeneous watersheds of three, one in the Han river and two in the Keum river. But I would select the northern and the sourthern river basins, and westward from Koan station, in the basins of the Han river. Also I would select the upstream area, and the downstream area including the watershed of Chungioo, Kongjoo, Chupungryung, and the Mt. Sock, in the basins of the Keum river. Finally, I could find that there couldn't in the Keum river basin. So, I decided out and analyze only river basins of the Han river with limitation mentioned above. (ii) The statistical method to select out the homogenous watersheds is the test of homogeneous variance, and it is estimated from the following equation: $$X_{k1}^2=[{\Sigma}(n_i-1)log\bar{S^2}-\Sigma(n_i-1)log\bar{S^2}]{\times}loge$$ (iii) Actually, each homogeneous watershed has individually its own intensity formula, But I would express them as the actual amount, because the equation of intensity variance is experiential and theoretical equation of the variance. Therefore the caluating equation is actually more convenient in the actual uses. (iv) This report is one of the series for me to give the basis to the actual designs. The cost for this study is provided by the Ministry of Construction. And the designs of the hydrological structures in the watersheds with limitation mentioned above may be concerned with and based upon this report.

  • PDF

THE EFFECT OF DIFFERENT CURING MODES ON COMPOSITE RESIN/DENTIN BOND STRENGTH IN CLASS ICAVITIES (1급 와동에서 상아질과 복합레진의 결합강도에 대한 중합방법의 효과)

  • Baek, Shin-Young;Cho, Young-Gon;Song, Byeong-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.428-434
    • /
    • 2008
  • The purpose of this study was to compare the microtensile bond strength in Class I cavities associated with different light curing modes of same light energy density. Occlusal enamel was removed to expose a flat dentin surface and twenty box-shaped Class I cavities were prepared in dentin. Single Bond (3M Dental product) was applied and Z 250 was inserted using bulk technique. The composite was light-cured using one of four techniques, pulse delay (PD group), soft-start (SS group), pulse cure (PC group) and standard continuous cure (CC group). The light-curing unit capable of adjusting time and intensity (VIP, Bisco Dental product) was selected and the light energy density for all curing modes was fixed at $16J/cm^2$. After storage for 24 hours, specimens were sectioned into beams with a rectangular cross-sectional area of approximately $1mm^2$ Microtensile bond strength $({\mu}TBS)$ test was per- formed using a univel·sal testing machine (EZ Test, Shimadzu Co.). The results were analyzed using oneway ANOVA and Tukey's test at significance level 0.05. The ${\mu}TBS$ of PD group and SS group was higher than that of PC group and CC group. Within the limitations of this in vitro study, modification of curing modes such as pulse delay and soft start polymerization can improve resin/dentin bond strength in Class I cavities by controlling polymerization velocity of composite resin.

A Plan for Startup of Optical Shop by Ophthalmic Optics Students (안경광학과 학생들의 안경원 창업예정도)

  • Lee, Ok-Jin;Jung, Se-Hoon;Shin, Jin-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.31-36
    • /
    • 2008
  • Purpose: To investigate optical shop startup awareness of ophthalmic optics students as a basic source for startup education. Methods: Total of 287 students from three ophthalmic optics college in kyung-gi region was surveyed and analyzed using SPSS analysis. Results: Optical shop startup business plan of ophthalmic optics students was very high (80.1%). For startup timing, over 6yrs of employe (37.0%) was most and there was significant difference according to age (p<.001) and optician family present (p<.05). For startup type, single startup type (37%) was most and there was significant difference according to grade (p<.01). For startup unit of space, 30 pyong (43.5%) was most, Seoul metropolitan area and kyung-gi region (54.4%) was most for startup region, and station area (40.8%) was most for startup location. The reason of non-startup was eye hospital and glass related company employe (35.7%) was most and optical shop employe (35.7%) was most for non-startup planner's way. Conclusions: Startup business plan was very high and need to have startup education for there startup provision.

  • PDF

Eight Year Survival Analysis of Patients with Triple Negative Breast Cancer in India

  • Doval, Dinesh Chandra;Suresh, P;Sinha, Rupal;Azam, Saud;Batra, Ullas;Talwar, Vineet;Kumar, Kapil;Mehta, Anurag
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.6
    • /
    • pp.2995-2999
    • /
    • 2016
  • Background: Triple-negative breast cancer (TNBC) often presents as an interval cancer with short survival upon metastasis and thus represents an important clinical challenge. The present study investigated the clinicopathologic characteristics and long term survival outcome of early and locally advanced TNBC. Materials and Methods: Medical records were reviewed retrospectively for 148 consecutive confirmed cases of TNBC treated in a single unit at our centre. Demographic profile, tumor type, histopathology details, treatment and follow-up information was recorded and immunohistochemistry was performed. Results: Age group >50 years was associated with tumors of clinical stage 3 (53.8%), pathological stage 3 (46.2%), pathological grade 3 (45.7%), presence of extracapsular extension (ECE, 48.5%) and lymphovascular invasion (LVI, 64.9%). Locally advanced breast cancers (LABCs) were characterized by pathological stage 3 (96.2%), presence of ECE (100%) and absence of LVI (46.7%) as compared to early breast cancers (EBCs) which had higher incidence of lower stage tumors (100%), absence of ECE (82%) and presence of LVI (91.9%; p-value <0.001. Better relapse free survival was observed in patients with no axillary involvement (69%; p-value <0.001) and absence of ECE (64%; p-value <0.001). Improved overall survival was seen in patients with EBC (90%; p-value 0.008), clear axilla (86%; p-value <0.001), absence of ECE (87%; p-value <0.001) and negative lymph nodes (90%; p-value 0.006). Conclusions: TNBCs are aggressive tumors which show poor long term survival. Patients with TNBC benefit from chemotherapy, thus better and less toxic treatment options are needed. Identification of newer targets and development of targeted therapies are the need of the hour.

The Geometrical Isomerization on Acidification in Hexamolybdoheteropoly Oxometalate. The Crystal Structure of $(NH_{4})_{4.5}[H_{3.5}\alpha-PtMo_{6}O_{24}].\;1.5H_{2}O,\;(NH_{4})_{4}[H_{4}\beta-PtMo_{6}O_{24}].\;1.5H_{2}O,\;and\;K_{3.5}[H_{4.5}\alpha-PtMo_{6}O_{24}].\;3H_{2}O$

  • Lee, Uk;Yukiyoshi Sasaki
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.1
    • /
    • pp.37-45
    • /
    • 1994
  • $(NH_4)_{4.5}[H_{3.5}{\alpha}-PtMo_6O_{24}]{\cdot}1.5\;H_2O(A),\;(NH_4)_4[H_4{\beta}-PtMo_6O_{24}]{\cdot}1.5\;H_2O(B),\;and\;K_{3.5}[H_{4.5}{\alpha}-PtMo_6O_{24}]{\cdot}3\;H_2O(C)$ have been synthesized and their molecular structures have been also determined by single-crystal X-ray diffraction technique. The space groups, unit cell parameters, and R factors are as follows: Compound A, monoclinic, $A_{2/a}$, a= 19.074 (3), b=21.490 (3), c=15.183 (2) ${\AA};\;{\beta}$=109.67 (1) ${\AA}$; z=8; R=0.075($IF_0I>4{\sigma}(IF_0I);$ Compound B, triclinic, P$bar{1}$, a=10.776 (2), b=15.174 (4), c=10.697 (3) ${\AA};\;{\alpha}$ =126.29 (2), ${\beta}$=111.55 (2), ${\gamma}$=93.18 (2) ${\AA}$; Z=2; R=0.046($IF_0I>3{\sigma}(IF_0I);$): Compound C, triclinic, Pl, a=12.426 (2), b=13.884 (2), c=10.089 (1) ${\AA}$; ${\alpha}$=102.59 (2), ${\beta}$=110.73 (1), ${\gamma}$=53.93 (1) ${\AA}$; Z=2; R=0.074 ($IF_0I>3{\sigma}(IF_0I)$. Compounds A and C contain the well-known Anderson structure (planar structure) heteropoly oxometalate having approximate $bar{3}_m(D_{3d})$ symmetry, while compound B contains the bent structure heteropoly oxometalate having appproximate $2_{mm}(C2_v)$ symmetry. The bent structure and the planar one are geometrical isomers. These compounds are rot only novel heteroply molybdates containing platinate(IV) but also the first example of geometrical isomerism in the hexamolybdoheteropoly oxometalates. That isomerization surprisingly occurred because of the change of only 0.5 non-acidic hydrogen atom attached to the polyanion such as $[H_{3.5}{\alpha} -PtMo_6O_{24}]^{4.5-}{\to}[H_4{\beta}-PtMo_6O_{24}]^{4-}{\to}[H_{4.5}{\alpha} -PtMo_6O_{24}]^{3.5-}$. It seems that the gradual protonation of the polyanion plays an important role in that isomerism. These heteropolyanions form dimers by strong hydrogen bonds between two heteropolyanions in the respective crystal system.

Applicability of Composite Polyurea Method Considering the Required Performance in Underground Parking Lot Upper Slab (공동주택 지하주차장 상부슬래브의 요구성능을 고려한 복합형 폴리우레아 공법의 적용성 검토)

  • Lee, Jung-Hun;Choi, Eun-Kyu;Song, Je-Young;Kim, Soo-Yeon;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.3
    • /
    • pp.243-254
    • /
    • 2019
  • In this study, problems of the waterproofing methods in which water leakage occurs in the upper slab of the underground parking lot of apartment houses and the requirements considering the characteristics of the upper slab, and selected the appropriate performance(proposal) for the composite polyurea process are reviewed. As a result of the study, it is necessary to review performance such as responsiveness to upper slab of the multi-unit underground parking lot that is comprised of (1) crack and behavior responsiveness, (2) surface integrity, (3) vertical watertight stability, (4) pressure layer construction, (5) impact and pressure response and (6) vehicle moving load. As a result of evaluating 5 items corresponding to the requirements for the soft and hard complex polyurea, all of them were found to meet the conditions, and each materials were improved by compounding the materials that had problems when applying a single-ply method, thereby clarifying the advantages and disadvantages of the material property. However, in order to apply to the actual site, additional evaluation on site applicability such as mock-up evaluation should be conducted, and subsequent studies on the applicability of the market through review of economic feasibility and maintenance is required.

Seismic Moment Conversion of instrumented Earthquakes in and around the Korean Peninsula (Ⅰ):from$m_b$or$m_s$to$m_0$ (한반도 및 인근 지역 계기지진의 지진모멘트 환산(Ⅰ):$m_b$또는 $m_s$에서$m_0$)

  • No, Myeong-Hyeon;Lee, Sang-Guk;Choe, Gang-Ryong
    • Journal of the Korean Geophysical Society
    • /
    • v.4 no.1
    • /
    • pp.47-55
    • /
    • 2001
  • conversion equations to calculate seismic moment(M_0) from body-wave magnitude(m_b), surface-wave magnitude(M_s), or both were derived by using 50 earthquakes occurred within 32~44°N and 123~133°E whose M_0 were determined together with m_b or M_s. We divided those earthquakes into the deeper and the shallower ones based on the reference focal depth of 70 km. The unit of M_0 is dyne-cm. In case of M_s, the deeper earthquakes exhibit the higher seismic moment than the shallower ones. Standard deviations associated with conversion equations for deeper and shallower earthquakes are 0.25 and 0.16, respectively, in moment magnitude. , for deeper earthquakes , for shallower earthquakes. In case of m_b, the dependence of conversion equation on focal depth is not clearly observed. Associated standard deviation is 0.28 in moment magnitude. In case that both m_b and M_s were determined, a new magnitude, , were defined for shallower earthquakes to derive a more stable conversion equation. Associated standard deviation is 0.14 in moment magnitude. Conversion equations above can be used to unify the earthquake size into a single magnitude type, i.e., moment magnitude, in and around the Korea Peninsula.

  • PDF

Effect of Chlorhexidine Mouthrinse on Prevention of Microbial Contamination during EBUS-TBNA: A Study Protocol for a Randomized Controlled Trial

  • Kim, Na Young;Park, Jae Hyeon;Park, Jimyung;Kwak, Nakwon;Choi, Sun Mi;Park, Young Sik;Lee, Chang-Hoon;Cho, Jaeyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.4
    • /
    • pp.291-298
    • /
    • 2021
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a standard diagnostic method for mediastinal and hilar lymphadenopathy. Although rare, fatal infectious complications can occur following EBUS-TBNA. However, to date, there is a lack of effective preventive strategies to reduce these complications. We started a trial to investigate the effect of chlorhexidine mouthrinse on the prevention of microbial contamination during EBUS-TBNA. Methods: This study is a single-center, parallel-group, assessor-blinded randomized controlled trial (RCT). We will enroll 112 adult participants undergoing EBUS-TBNA using a convex probe, and randomly assign them to two groups at a 1:1 ratio. The intervention group will gargle for 1 minute with 100 mL of 0.12% chlorhexidine gluconate before EBUS-TBNA, while the control group will have no mouthrinse before the procedure. Immediately after completion of EBUS-TBNA on all targeted lesions with an aspiration needle, a needle wash sample will be taken by instilling 5 mL of sterile saline into the used needle. The primary outcome is colony forming unit (CFU) counts in aerobic cultures of the needle wash samples. Secondary outcomes are CFU counts in anaerobic cultures, fever within 24 hours after EBUS-TBNA, and infectious complications within 4 weeks after EBUS-TBNA. Conclusion: This trial was designed as the first RCT to investigate the effect of chlorhexidine mouthrinse on the prevention of microbial contamination during EBUS-TBNA. Results from this trial can provide clinical evidence for a simple, safe, and cost-effective strategy to prevent infectious complications following EBUS-TBNA (ClinicalTrials.gov ID: NCT04718922, registered on 22 January 2021).

Analysis of Contents related to Models in the Chemistry Textbooks of the 2009 & 2015 Revised Curricula: Focusing on the Electrolysis of Aqueous Solutions (2009 및 2015 개정 교육과정의 화학 교과서에서 모델 관련 내용 분석: 수용액 전기 분해를 중심으로)

  • Kim, Kihyang;Chang, Hasok;Paik, Seoung-Hey
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.4
    • /
    • pp.289-306
    • /
    • 2019
  • The purpose of this study is to compare the contents of chemistry textbooks developed according to the 2015 revised curriculum with the contents of the 2009 revised curriculum to research the change in "the development and use of models". To do this, we analyzed 8 kinds of Chemistry I textbooks and 6 kinds of Chemistry II textbooks from the 2015 revised curriculum and compared them with 4 kinds of Chemistry I textbooks and 4 kinds of Chemistry II textbooks from the 2009 revised curriculum. The scope of the analysis was the explanations of the textbooks related to aqueous electrolysis experiments. In order to compare the contents regarding electrolytes when the same experiments are interpreted with different models, we analyzed contents of 4 kinds of middle school science textbooks from the 2015 revised curriculum and 9 kinds of middle school science textbooks from the 2009 revised curriculum. As a result of the analysis, the same experiment was explained by different models according to the grade level and unit, and all explanations were limited to a single model. Also, the tendency to limit the kinds of electrolytes for controlled experimental results is more pronounced in the 2015 revised curriculum than in the 2009 revised curriculum. From this results, we suggest that efforts are needed to reflect the "development and use of models" in chemistry textbooks developed according to the 2015 revised curriculum.

Design and Performance Evaluation of Integral-type Hot BoP for Recovering High-temperature Exhaust Gas in 2 kW Class SOFC (2 kW급 고체산화물연료전지의 고온배기가스 폐열회수를 위한 일체형 Hot BoP의 설계 및 성능 평가)

  • Kim, Young Bae;Kim, Eun Ju;Yoon, Jonghyuk;Song, Hyoungwoon
    • Applied Chemistry for Engineering
    • /
    • v.30 no.1
    • /
    • pp.62-67
    • /
    • 2019
  • This study was focused on the design and the performance analysis of integral Hot BoP for recovering waste heat from high-temperature exhaust gas in 2 kW class solid oxide fuel cell (SOFC). The hot BoP system was consisted of a catalytic combustor, air preheater and steam generator for burning the stack exhaust gas and for recovering waste heat. In the design of the system, the maximum possible heat transfer was calculated to analyze the heat distribution processes. The detail design of the air preheater and steam generator was carried out by solving the heat transfer equation. The hot BoP was fabricated as a single unit to reduce the heat loss. The simulated stack exhaust gas which considered SOFC operation was used to the performance test. In the hot BoP performance test, the heat transfer rate and system efficiency were measured under various heat loads. The combustibility with the equivalent ratio was analyzed by measuring CO emission of the exhaust gas. As a result, the thermal efficiency of the hot BoP was about 60% based on the standard heat load of 2 kW SOFC. CO emission of the exhaust gas rapidly decreased at an equivalent ratio of 0.25 or more.