• 제목/요약/키워드: single implant

검색결과 348건 처리시간 0.024초

상악 전치부 단일 임플란트의 심미 보철 수복 증례 (Single implant restoration with esthetic prosthodontic treatment in maxillary anterior tooth: A case report)

  • 강현;서누리;박상원;임현필;윤귀덕;양홍서
    • 대한치과보철학회지
    • /
    • 제56권4호
    • /
    • pp.354-359
    • /
    • 2018
  • 상악 전치부의 단일 임플란트 수복 치료 시, 치은 퇴축 및 골결손 문제를 가질 경우 임플란트 보철의 심미적인 결과를 얻는 것은 쉽지 않다. 장기적으로 심미적 안정성이 유지되기 위해서는 임플란트를 이상적인 위치에 식립하는 것이 중요하며 연조직의 회복 및 보철물과의 조화가 중요하다. 이러한 심미성이 더욱 요구되는 임플란트 보철물의 제작 시 이상적인 임플란트의 위치 뿐만 아니라, 주변 연조직과의 조화 역시 중요하다. 본 증례에서는 상악 전치부에서 골결손과 치은 퇴축이 진행된 47세 남자환자에서 골유도재생술 및 치은재형성술을 통해 심미 임플란트 치료를 진행하였다.

Five-year retrospective radiographic follow-up study of dental implants with sandblasting with large grit, and acid etching-treated surfaces

  • Kim, Hak-Kyun;Lee, Eun-Young;Kim, Jae-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권6호
    • /
    • pp.317-321
    • /
    • 2015
  • Objectives: The purpose of this study is to evaluate five-year radiographic follow-up results of the Korean sandblasting with large grit, and acid etching (SLA)-treated implant system. Materials and Methods: The subjects of the study are 54 patients who have been followed-up to date, of the patients who underwent implant surgery from May 1, 2009 to April 30, 2011. In all, 176 implant placements were performed. Radiographs were taken before the first surgery, immediately after the first and second surgeries, immediately and six months after the final prosthesis installation, and every year after that. Bone loss was evaluated by the method suggested by Romanos and Nentwig. Results: A total of 176 implant placements were performed - 122 in men and 54 in women. These patients have been followed-up for an average of 4.9 years. In terms of prosthetic appliances, there were 156 bridges and 20 single prostheses. Nine implants installed in the maxillary molar area, three in the mandibular molar area and two in the maxillary premolar area were included in group M, with bone loss less than 2 mm at the crestal aspect of the implant. Of these, eight implants were single prostheses. In all, six implants failed - four in the mandible and two in the maxilla. All of these failures occurred in single-implant cases. The implant survival rate was 98.1% on the maxilla and 94.3% on the mandible, with an overall survival of 96.6%. Conclusion: Within the limitations of this study, implants with the SLA surface have a very superior survival rate in relatively poor bone environments such as the maxilla.

Maxillary anterior single implant prosthesis ; a clinical case

  • Kim Seung-June;Kwon Kung-Rock;Lee Sung-Bok;Woo Yi-Hyung;Choi Dae-Gyun;Choi Boo-Byung
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.306-312
    • /
    • 2001
  • Achieving an aesthetic implant-supported restoration in the single tooth missing case can be challenging when the implant site is in e anterior region. The objective of this report is to focus on presurgical evaluation of implant site and systematic development of related prosthetic modalities. An accurate diagnostic evaluation, a systematically developed pesurgical plan, and knowledge and clinical skill of the various related therapeutic modalities are indispensible. Collection of patient's information, appropriate abutment selection, soft tissue contour, implant axis, and occlusion need to be discussed for aesthetic clinical outcome. For aesthetic restoration, such as surgical guide stent for precise implant positioning customized provisional restoration for development of optimal periimplant soft tissue contours, and fabrication customized abutment (mesiostructure) for veriable emergence profile, are recommended.

  • PDF

Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: an alternative to the conventional Implant prosthetic system

  • Lee, Jae-Hong;Lee, Jong-Bin;Kim, Man-Yong;Yoon, Joon-Ho;Choi, Seong-Ho;Kim, Young-Taek
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.150-157
    • /
    • 2016
  • PURPOSE. The modified lateral-screw-retained implant prosthesis (LSP) is designed to combine the advantages of screw- and cement-retained implant prostheses. This retrospective study evaluated the mechanical and biological complication rates of implant-supported single crowns (ISSCs) inserted with the modified LSP in the posterior region, and determined how these complication rates are affected by clinical factors. MATERIALS AND METHODS. Mechanical complications (i.e., lateral screw loosening [LSL], abutment screw loosening, lateral screw fracture, and ceramic fracture) and biological complications (i.e., peri-implant mucositis [PM] and peri-implantitis) were identified from the patients' treatment records, clinical photographs, periapical radiographs, panoramic radiographs, and clinical indices. The correlations between complication rates and the following clinical factors were determined: gender, age, position in the jaw, placement location, functional duration, clinical crown-to-implant length ratio, crown height space, and the use of a submerged or nonsubmerged placement procedure. RESULTS. Mechanical and biological complications were present in 25 of 73 ISSCs with the modified LSP. LSL (n=11) and PM (n=11) were the most common complications. The incidence of mechanical complications was significantly related to gender (P=.018). The other clinical factors were not significantly associated with mechanical and biological complication rates. CONCLUSION. Within the limitations of this study, the incidence of mechanical and biological complications in the posterior region was similar for both modified LSP and conventional implant prosthetic systems. In addition, the modified LSP is amenable to maintenance care, which facilitates the prevention and treatment of mechanical and biological complications.

임플란트와 상부구조물 사이의 micromotion에 관한 연구 (A study on the micromotion between the dental implant and superstructure)

  • 김지혜;송광엽;장태엽;박주미
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.17-25
    • /
    • 2003
  • Treatment with implants of single tooth missing cases is both functional and esthetic. Although the success rate of single-tooth implant treatments is increasing, sometimes it makes some problems. Problems with single-tooth implant treatments include soft tissue complications, abutment screw fracture, and most commonly, abutment screw loosening, and these involve the instability of the dental implant-superstructure interface. This study investigated and compared dental implant screw joint micromotion of various implant system with external connection or internal connection when tested under simulated clinical loading, Six groups (N=5) were assessed: (1) Branemark AurAdapt (Nobel Biocare, Goteborg, Sweden), (2) Branemark EsthetiCone (Nobel Biocare, Goteborg, Sweden), (3) Neoplant Conical (Neobiotec, Korea), (4) Neoplant UCLA (Neobiotec, Korea), (5) Neoplant 5.5mm Solid (Neobiotec, Korea), and (6) ITI SynOcta (Institute Straumann, Waldenburg, Switzerland). Six identical frameworks were fabricated. Abutment screws were tightened to 32-35 Ncm and occlusal screw were tightened to 15-20 Ncm with an electronic torque controller. A mechanical testing machine applied a compressive cyclic load of 20kg at 10Hz to a contact point on each implant crown. Strain gauge recorded the micromotion of the screw joint interface once a second. Data were selected at 1, 500, 5,000, 10,000, 20,000, 30,000, 40,000 and 50,000 cycle and 2-way ANOVA test was performed to assess the statistical significance. The results of this study were as follows; The micromotion of the implant-superstructure in the interface increased gradually through 50,000 cycles for all implant systems. In the case of the micromotion according to cycle increase, Neoplant Conical and Neoplant UCLA system exhibited significantly increasing micromotion at the implant-superstructure interface (p<0.05), but others not significant. In the case of the micromotion of the implant-superstructure interface at 50,000 cycle, the largest micromotion were recorded in the Branemark EsthetiCone, sequently followed by Neoplant Conical, Neoplant UCLA, Branemark AurAdapt, ITI SynOcta and Neplant Solid. Internal connection system showed smaller micromotion than external connection system. Specially, Neoplant Solid with internal connection system exhibited significantly smaller micromotion than other implant systems except ITI SynOcta with same internal connection system (p<0.05). In the case of external connection, Branemark EsthetiCone and Neoplant Conical system with abutment showed significantly larger micromotion than Branemark AurAdapt without abutment (p<0.05).

Esthetic evaluation of maxillary single-tooth implants in the esthetic zone

  • Cho, Hae-Lyung;Lee, Jae-Kwan;Um, Heung-Sik;Chang, Beom-Seok
    • Journal of Periodontal and Implant Science
    • /
    • 제40권4호
    • /
    • pp.188-193
    • /
    • 2010
  • Purpose: The aim of this study is to assess the influence exerted by the observer's dental specialization and compare patients' opinion with observers' opinion of the esthetics of maxillary single-tooth implants in the esthetic zone. Methods: Forty-one adult patients, who were treated with a single implant in the esthetic zone, were enrolled in this study. Eight observers (2 periodontists, 2 prosthodontists, 2 orthodontists and 2 senior dental students) applied the pink esthetic score (PES)/white esthetic score (WES) to 41 implant-supported single restorations twice with an interval of 4 weeks. We used a visual analog scale (VAS) to assess the patient's satisfaction with the treatment outcome from an esthetic point of view. Results: In the PES/WES, very good and moderate intraobserver agreements were noted between the first and second rating. The mean total PES/WES was $11.19{\pm}3.59$. The mean PES was $5.17{\pm}2.29$ and mean WES was $6.02{\pm}1.96$. In the total PES/WES, the difference between the groups was not significant. However, in the WES, the difference between the groups was significant and prosthodontists were found to have assigned poorer ratings than the other groups. Periodontists gave higher ratings than prosthodontists and senior dental students. Orthodontists were clearly more critical than the other observers. The statistical analysis revealed statistically significant correlation between patients' esthetic perception and dentists' perception of the anterior tooth. However, the correlation between the total PES/WES and the VAS score for the first premolar was not statistically significant. Conclusions: The PES/WES is an objective tool in rating the esthetics of implant supported single crowns and adjacent soft tissues. Orthodontists were the most critical observers, while periodontists were more generous than other observers. The statistical analysis revealed a statistically significant correlation between patients' esthetic perception and dentists' perception of the anterior tooth.

임플랜트 지대주에 따른 나사 풀림의 연구 (THE INFLUENCE OF IMPLANT FIXTURE-ABUTMENT CONNECTION DESIGN ON SCREW LOOSENING)

  • 문양숙;박상원;방몽숙;양홍서;박하옥
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.174-184
    • /
    • 2006
  • Purpose: Current trend in implant dentistry is changing from external connection to internal connection. To evaluate the splinting of external and internal connection implant on screw loosening, 2-units prosthesis was fabricated with BioPlant $System^(R)$ of external connection type and Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. Material and Method: Experimental group is classified into three groups. 1) $G_1-EE$: 2-units prosthesis was fabricated with two Bioplant $System^(R)$ of external connection type. 2) $G_1-EI$: 2-units prosthesis was fabricated with one BioPlant $System^(R)$ of external connection type and one Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. 3) $G_1-II$: 2-units prosthesis was fabricated with two Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. In fabricating 2-units prosthesis, two hexed abutments are recommended when two implants are installed parallel, otherwise one hexed abutment is used on major occlusal force area and one nonhexed abutment is used on the other area. Since it is rare to find two implants being parallel, it is hard to fabricate prosthesis with passive adaptation using two hexed abutments. It is much more difficult to acquire passive adaptation when using hex abutment compared to nonhex abutment. To evaluate the influence of hexed and nonhexed abutment on screw loosening, 2-units prosthesis was fabricated with hexed and nonhexed abutment. Experimental group is classified into three groups. 1) $G_2-HH$: 2-units prosthesis was fabricated with two hexed abutments. 2) $G_2-HN$: 2-units prosthesis was fabricated with one hexed abutment and one nonhexed abutment. 3) $G_2-NN$: 2-units prosthesis was fabricated with two nonhexed abutments. Result: The results of comparing the detorque value after loading on a each prosthesis periodically are as follows. 1. In splinting group of external and internal connection implant, $G_1-II$ group demonstrated the biggest detorque value, followed by $G_1-EI$ group and $G_1-EE$ group. 2. There is no notable significance between external connection implant of $G_1-EI$ group and $G_1-EE$ group and also no significance between internal connection implant of $G_1-EI$ group and $G_1-II$ group. 3. $G_2-HH$ group showed higher detorque value than $G_2-HN\;and\;G_2-NN$ group. From the results, we can concluded that using both external connection and internal connection implant together is clinically acceptable and in order to acquire a good passive adaptation in fabricating 2-units implant prosthesis we can use two nonhexed abutments.

Blossom smart expander technology for tissue expander-based breast reconstruction facilitates shorter duration to full expansion: A pilot study

  • Choi, Youna K.;Rochlin, Danielle H.;Nguyen, Dung H.
    • Archives of Plastic Surgery
    • /
    • 제47권5호
    • /
    • pp.419-427
    • /
    • 2020
  • Background This study evaluated the Blossom system, an innovative self-filling, rate-controlled, pressure-responsive saline tissue expander (TE) system. We investigated the feasibility of utilizing this technology to facilitate implant-based and combined flap with implant-based breast reconstruction in comparison to conventional tissue expansion. Methods In this prospective, single-center, single-surgeon pilot study, participants underwent either implant-based breast reconstruction or a combination of autologous flap and implantbased breast reconstruction. Outcome measures included time to full expansion, complications, total expansion volume, and pain scores. Results Fourteen patients (TEs; n=22), were included in this study. The mean time to full expansion was 13.4 days (standard error of the mean [SEM], 1.3 days) in the combination group and 11.7 days (SEM, 1.4 days) in the implant group (P=0.78). The overall major complication rate was 4.5% (n=1). No statistically significant differences were found in the complication rate between the combination group and the implant group. The maximum patient-reported pain scores during the expansion process were low, but were significantly higher in the combination group (mean, 2.00±0.09) than in the implant group (mean, 0.29±0.25; P=0.005). Conclusions The reported average duration for conventional subcutaneous TE expansion is 79.4 days, but this pilot study using the Blossom system achieved an average expansion duration of less than 14 days in both groups. The Blossom system may accommodate single-stage breast reconstruction. The overall complication rate of this study was 4.5%, which is promising compared to the reported complication rates of two-stage breast reconstruction with TEs (20%-45%).

상악 단일 치아 임프란트의 후향적 연구 (A Retrospective study on upper single tooth implants)

  • 조수진;이근우;조규성;문익상
    • Journal of Periodontal and Implant Science
    • /
    • 제33권3호
    • /
    • pp.383-393
    • /
    • 2003
  • The aim of this retrospective study was to compare the amount of marginal bone loss between upper anterior area and upper posterior area with 71 upper single-tooth restorations on 2 stage machined $Br{{\aa}}nemark$ implants since Jan 1995. The second aim was to compare the bone defect group which had dehiscence and fenetration and the others in the upper anterior region. The results were as follows. 1. The most frequent reason of missing tooth in the upper anterior region was trauma by 61%. While upper posterior region showed various reasons such as congenital missing, advanced periodontitis, trauma. 2. Peri-implantitis with fistula occurred 1 of 41 implants in the upper anterior group in 1 year after loading and 2 of 32 implants in the upper posterior group failed before loading. The 1 year success rate of upper anterior group was 97.56 %, and 93.75 % for upper posterior group. 3. The mean marginal bone loss in the upper anterior group was 0.44${\pm}$0.25 mm, while 0.57${\pm}$0.32 mm in the upper posterior group. There was statistically significant difference in the amount of mean marginal bone loss (P${\pm}$0.10 mm at one year, and 0.48${\pm}$0.26 mm for the control group. No statistically significant difference of mean marginal bone loss was showen between bone defect group and the others at implantation. According to the results, the upper anterior region showed less marginal bone loss than the upper posterior region. In case of missing single upper tooth, careful consideration on recipient residual ridge to determine proper implant diameter and length, sufficient healing time, proper loading would lead to implant success. Single tooth implants in the maxilla seemed to be an alternative to fixed partial dentures without damage to adjacent teeth.

깊은 나사선을 갖는 임플란트를 이용한 상악 구치부 조기 하중: 증례보고 (Early loading on a maxillary posterior single implant with deepened threads: a case report)

  • 한창훈;김현승;박상원;윤귀덕;주한성;임현필
    • 구강회복응용과학지
    • /
    • 제30권3호
    • /
    • pp.253-258
    • /
    • 2014
  • 본 증례는 상악 구치부에서 실패한 임플란트 제거 후 깊은 나사선을 갖는 직경이 큰 임플란트를 식립 후 조기하중을 가한 증례이다. 1년 경과 후, 임플란트 안정성 지수에서 안정적인 결과를 보였다. 본 임상증례는 상악 구치부에서 깊은 나사선을 갖는 임플란트를 이용한 조기하중의 가능성을 보여준다.