• Title/Summary/Keyword: simultaneous-source

Search Result 246, Processing Time 0.028 seconds

The performance of PEMFC during exposure to simultaneous sulfur impurity poisoning on cathode and anode (공기극과 연료극의 복합 황불순물에 의한 고분자 전해질막 연료전지의 성능에 미치는 영향)

  • Lee, Soo;Jin, Seok-Hwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.594-598
    • /
    • 2012
  • Polymer electrolyte membrane fuel cell(PEMFC) performance degrades seriously when sulfur dioxide and hydrogen sulfide are contaminated in the fuel gas at anode and air source at cathode, respectively. This paper reveals the effect of the combined sulfur impurity poisoning on both PEMFC cathode and anode parts through measuring electrical performance on single FC operated under 1 ppm to 10 ppm impurity gases. The severity of $SO_2$ and $H_2S$ poisoning depended on concentrations of impurity gases under optimum operating conditions($65^{\circ}C$ of cell temperature and 100 % relative humidity). Sulfur adsorption occured on the surface of Pt catalyst layer on MEA. In addition, MEA poisoning by impurity gases were cumulative. After four consecutive poisonings with 1, 3, 5 to 10 ppm, the fuel cell performance of PEMFC was decrease upto 0.54 V(76 %) from 0.71 V.

Papers : Simultaneous Monitoring of Strain and Temperature During and After Cure of Unsymmetric Cross - ply Composite Laminate Using Fiber Optic Sensors (논문 : 비대칭 직교적층 복합재료 적층판의 성형시 및 성형후 광섬유 센서를 이용한 변형률 및 온도의 동시 모니터링)

  • Gang,Hyeon-Gyu;Gang,Dong-Hun;Hong,Chang-Seon;Kim,Cheon-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.1
    • /
    • pp.49-55
    • /
    • 2002
  • In this paper, we present the simulation monitoring of strain and temperature during and after the cure of unsymmetric composite laminate using fiber optic sensors. Fiber Bragg grating/extrinsic Fabry-Perot interferometric (FBG/EFPI) hybrid sensors are used to measure those measurands. The characteristic matrix of the sensor is analytically derived and measurements can be done without sensor calibration. A wavelength-swept fiber laser is utilised as a lighr source. Two FBG/EFPI sensors are embedded in a graphite/epoxy unsymmetric cross-ply composite laminate in different directions and different locations. We perform a real time monitoring of fabrication strains and temperatures at two points of the composite laminate during cure process in an autoclave. Also, the thermal strains and temperatures of the fabricated laminate are measured in a thermal chamber. Through these experiments, we can provide a basis for the efficient smart processing of composite and know the thermal behavior of unsymmetric cross-ply composite laminate.

Simultaneous observations of SiO and $H_2O$ masers toward AGB and post-AGB stars

  • Yoon, Dong-Hwan;Cho, Se-Hyung;Kim, Jaeheon;Cho, Chi-Young;Yun, Youngjoo;Park, Yong-Sun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.237.2-237.2
    • /
    • 2012
  • We performed simultaneous observations of SiO v=1, 2, $^{29}SiO$ v=0, J=1-0 and $H_2O$ $6_{16}-5_{23}$ maser lines toward 132 AGB and 183 post-AGB stars in order to investigate how evolutionary characteristics from AGB to post-AGB stars appear in these two maser emissions. The observations were carried out from 2011 February to 2012 March using the Korean VLBI Network 21-m radio telescopes. We have detected SiO and/or $H_2O$ maser emission from 29 sources out of 183 post-AGB stars including 19 new detections. Of 132 AGB stars which are mainly selected based on the IRAS Point Source Catalog, we detected SiO and/or $H_2O$ maser emission from 38 stars including 18 newly detected sources. An evolutionary characteristic from AGB to post-AGB stars is discussed in IRAS two-color diagram. It is found that SiO v=2, J=1-0 maser emission without SiO v=1 maser detections was detected from 8 sources among 21 SiO detected post-AGB stars and the intensity of SiO v=2, J=1-0 maser tends to be much stronger than that of SiO v=1. We also found that for the post-AGB stars the maser detection rate of blue group sources (which have higher outflow velocities than red group) are higher than that of red group. Especially, only $H_2O$ maser emission was detected from 7 sources among 94 red group sources without SiO maser detections.

  • PDF

Phoswich Detector for Simultaneous Measuring Alpha/beta Particles (알파/베타선 동시측정용 phoswich 검출기)

  • Kim, Gye-Hong;Park, Chan-Hee;Lee, Kune-Woo;Jung, Chong-Hun;Seo, Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.2
    • /
    • pp.111-117
    • /
    • 2008
  • The new type phoswich detector consisting of the ZnS(Ag) and plastic scintillator for alpha/beta-ray simultaneous counting was developed for monitoring radiological contamination inside pipes. The detection performance was estimated using the PSD (pulse shape discrimination) method as a function of distance between the scintillator and radioactive source. The attenuation of particles traveling through a thin film for preventing the detector from being contaminated was experimentally estimated. It is concluded from our investigation that the phoswich detector developed can provide a sufficient alpha/beta-ray discrimination. The application of a thin film for preventing the detector from being contaminated was proven to be feasible.

  • PDF

Simultaneous Determination of Seven Compounds in Houttuynia cordata using UPLC-PDA

  • Kim, Hyo-Seon;Lee, A-Yeong;Park, Jun-Yeon;Jo, Ji-Eun;Moon, Byeong-Cheol;Chun, Jin-Mi;Kil, ki-Jung;Kim, Ho-Kyoung
    • Natural Product Sciences
    • /
    • v.18 no.3
    • /
    • pp.158-165
    • /
    • 2012
  • A UPLC method for the simultaneous determination of seven compounds was established for the quality control in H. cordata. The UPLC was performed on a $C_{18}$ HSS T3 $2.1{\times}100$ mm, 1.8 ${\mu}m$ column during a 13 minute gradient elution of 0.2% aqueous acetic acid and acetonitrile with the flow rate of 0.2 mL/min at $30^{\circ}C$. The UPLC method was validated according to the ICH guideline of analytical procedures with respect to precision, accuracy, and linearity. The limit of determination and quantitation for the seven compounds were 0.01-0.09 and 0.03-0.28 ${\mu}g/mL$, respectively. The calibration curves of all seven compounds showed good linearity ($r^2$ > 0.999). The intra-day and inter-day the RSD values used to evaluate the precision of analysis were less than 0.9%. The recoveries of quantified compounds ranged from 98.63 to 103.85%. The developed UPLC method was found to be effective, convenient and sensitivity for quantitative analysis of seven compounds in H. cordata. This work could be provided a baseline source for quality control of H. cordata.

Power Monitoring System with Multiple Input Channels Using the Definition of IEEE Standard 1459-2010 (IEEE 1459-2010 규격의 정의를 이용한 다중 입력 채널을 갖는 전력 감시 시스템)

  • Jeon, Jeong-Chay;Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3100-3106
    • /
    • 2014
  • This paper develops power measurement system with multiple sensor input channels (voltage-8 channels and current-10 channels) that simultaneously can monitor power components for both supply and load side of power system. The hardware implementation of the proposed system is based on TMS320C42 DSP and signal processing program algorithm to calculate power components use the definition of IEEE Standard 1459-2010 related power quality. The performance of the developed system is tested by using standard ac power source device, and the test results showed that accuracy of the developed system is less than 0.2 %. Also, field test of the proposed system in the three-phase and four-wire power system was implemented. Simultaneous multiple channel measurement and analysis of power components in commercial and industrial electrical power system using the proposed system will be necessary to reduce power quality problems.

Simultaneous Transmission of Optical Wireless Power Transfer and Optical Wireless Communication using a Laser Diode (레이저 기반의 광 무선충전 및 광 무선통신의 동시전송)

  • Shin, Jae-Woo;Yun, Tae-Uk;Kim, Sung-Man
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.605-610
    • /
    • 2021
  • Wireless charging method using a laser is considered as the most efficient method at a long distance of the wireless charging method. Combining long-range laser wireless charging technology with wireless communication technology will make it possible to use it for a variety of applications. Accordingly, this paper shows the results of research and experiments on wireless charging and wireless communication simultaneously based on a laser. This technique uses a laser as a light source for E/O(: Electric-to-Optical) conversion at the transmitter for optical wireless power transmission. In the experimental results, the optical power transmission using a 100 mW laser transmitter and a solar cells receiver showed a DC-to-DC efficiency of 1.9 %, wireless optical communication showed a transmission speed of up to 90 kbps when the transmission distance is 15 m.

Gram-Schmidt process based adaptive time-reversal processing (그람슈미트 과정 기반의 적응형 시역전 처리)

  • Donghyeon Kim;Gihoon Byun;J. S. Kim;Kee-Cheol Shin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.2
    • /
    • pp.184-199
    • /
    • 2024
  • Residual crosstalk has been considered as a major drawback of conventional time-reversal processing in the case of simultaneous multiple focusing. In this paper, the Gram-Schmidt process is applied to time-reversal processing to mitigate crosstalk in ocean waveguides for multiple probe sources. Experimental data-based numerical simulations confirm that nulls can be placed at multiple locations, and it is shown that different signals can be simultaneously focused at different probe source locations, ensuring distortionless responses in terms of active time-reversal processing. This focusing property is also shown to be much less affected by a reduction in the number of receivers than the adaptive time-reversal mirror method. The proposed method is shown to be effective in eliminating crosstalk in passive multi-input multi-output communications using sea-going data.

Comparison of SUV for PET/MRI and PET/CT (인체 각 부위의 PET/MRI와 PET/CT의 SUV 변화)

  • Kim, Jae Il;Jeon, Jae Hwan;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.10-14
    • /
    • 2013
  • Purpose: Due to developed simultaneous PET/MRI, it has become possible to obtain more anatomical image information better than conventional PET/CT. By the way, in the PET/CT, the linear absorption coefficient is measured by X-ray directly. However in case of PET/MRI, the value is not measured from MRI images directly, but is calculated by dividing as 4 segmentation ${\mu}-map$. Therefore, in this paper, we will evaluate the SUV's difference of attenuation correction PET images from PET/MRI and PET/CT. Materials and Methods: Biograph mCT40 (Siemens, Germany), Biograph mMR were used as a PET/CT, PET/MRI scanner. For a phantom study, we used a solid type $^{68}Ge$ source, and a liquid type $^{18}F$ uniformity phantom. By using VIBE-DIXON sequence of PET/MRI, human anatomical structure was divided into air-lung-fat-soft tissue for attenuation correction coefficient. In case of PET/CT, the hounsfield unit of CT was used. By setting the ROI at five places of each PET phantom images that is corrected attenuation, the maximum SUV was measured, evaluated %diff about PET/CT vs. PET/MRI. In clinical study, the 18 patients who underwent simultaneous PET/CT and PET/MRI was selected and set the ROI at background, lung, liver, brain, muscle, fat, bone from the each attenuation correction PET images, and then evaluated, compared by measuring the maximum SUV. Results: For solid $^{68}Ge$ source, SUV from PET/MRI is measured lower 88.55% compared to PET/CT. In case of liquid $^{18}F$ uniform phantom, SUV of PET/MRI as compared to PET/CT is measured low 70.17%. If the clinical study, the background SUV of PET/MRI is same with PET/CT's and the one of lung was higher 2.51%. However, it is measured lower about 32.50, 40.35, 23.92, 13.92, 5.00% at liver, brain, muscle, fat, femoral head. Conclusion: In the case of a CT image, because there is a linear relationship between 511 keV ${\gamma}-ray$ and linear absorption coefficient of X-ray, it is possible to correct directly the attenuation of 511 keV ${\gamma}-ray$ by creating a ${\mu}$map from the CT image. However, in the case of the MRI, because the MRI signal has no relationship at all with linear absorption coefficient of ${\gamma}-ray$, the anatomical structure of the human body is divided into four segmentations to correct the attenuation of ${\gamma}-rays$. Even a number of protons in a bone is too low to make MRI signal and to localize segmentation of ${\mu}-map$. Therefore, to develope a proper sequence for measuring more accurate attenuation coefficient is indeed necessary in the future PET/MRI.

  • PDF

Influence of COD/Nitrate-N Ratio on Denitrification and Methanogenesis in Anaerobic Sludge (COD/Nitrate-N비가 혐기성 슬러지에서 탈질과 메탄화에 미치는 영향)

  • Park, Sang-Min;Jun, Hang-Bae;Choi, Chang-Ok;Lee, Joon-Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.739-745
    • /
    • 2005
  • Simultaneous denitrification and methanogenesis at various influent COD/Nitrate-N(below C/N) ratio was investigated with two different anaerobic sludges of which one was inoculated with glucose only and the other was inoculated with glucose and nitrate. Three different C/N ratios of 30, 20, and 10 were applied with each anaerobic sludge in serum bottles agitated in a rotary shaker to monitor the time related changes of amount of gas production and gas composition. Glucose was used as a single carbon source, which was adjusted to 1,000 mg/L as COD and potassium nitrate was used as a nitrogen source to adjust the each C/N ratio. COD removal by methanogenesis was dominant at higher C/N ratios, while COD removal by denitrification was dominant at lower C/N ratios. With the sludges cultured at C/N ratios below 10, SMA and SDNR rising different carbon substrates were investigated. The most efficient carbon substrate was acetate and the highest SMA and SDNR were 0.76 g COD/g VSS day with pure anaerobic sludge and 1.38 g ${NO_3}^--N/g$ VSS day with sludge cultured at C/N ratio of 5, respectively.