• 제목/요약/키워드: simultaneous recovery

검색결과 315건 처리시간 0.048초

Simultaneous Determination of 4-Nitrotoluene and Benzophenone in Ground Water and Soil by Gas Chromatography-Mass Spectroscopy

  • Kwon, Oh-Seung;Kim, Eun-Young;Ryu, Jae-Chun
    • 분석과학
    • /
    • 제16권1호
    • /
    • pp.59-69
    • /
    • 2003
  • Benzophenone (BZP) and 4-nitrotoluene (4-NT) listed as endocrine disrupting chemicals are suspected to contaminate ground water sites and soil. Analytical method for simultaneous determination of the two chemicals in soil and ground water was developed by gas chromatography-mass spectrometry. Water (100 ml) was extracted with hexane, and soil (10 g) was extracted with methanol and hexane. Recovery in water was >72% for BZP and 90-118% for 4-NT. Recovery for 4-NT and BZP in soil was 51-59% with coefficient variation of less than 19.5%. Calibration curves showed a good linearity with $r^2=0.997$. In water and soil collected at nation-wide sites, BZP was found at 5 sites among 43 water sites at the concentration of $14.87{\pm}3.83ng/100 ml$. No 4-NT was found. It is suggested that this method is appropriate to the simultaneous quantitation of 4-NT and BZP in ground water and soil samples.

HPLC를 이용한 옥천산 중 갈근, 감초, 오미자 지표성분의 다성분 동시분석 (Quality Evaluation of Herbal Prescription, Oc Chun San, Employing Simultaneous Determination of the Marker Compounds by HPLC)

  • 유정림;장대식;김진숙
    • 한국한의학연구원논문집
    • /
    • 제11권2호
    • /
    • pp.167-178
    • /
    • 2005
  • As a part of the quality control of herbal prescriptions which has been used for diabetes and related diseases, a reversed-phase liquid chromatographic method was developed for the simultaneous quantification of the three marker compounds, puerarin (Puerariae Radix), glycyrrhizin (Glycyrrhizae Radix), schizandrin (Schizandrae Fructus) in Oc Chun San. The HPLC analysis method was validated for parameters such as linearity, Limits of Detection(LOD), quantification(LOQ), repeatability, stability and recovery.

  • PDF

Simultaneous Determination of 285 Chemicals in Water at ppt Levels by GC-Ion Trap Mass Spectrometry

  • Kadokami, Kiwao;Sato, Kenji;Koga, Minoru;Shinohara, Ryota
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.771-778
    • /
    • 1995
  • The authors have developed an analytical method for determining trace amounts of 285 kinds of chemicals in natural waters by GC-ion trap MS. The results of overall recovery tests at $0.1{\mu}g/l$ showed that the mean recovery was 92.1% and the mean relative standard deviation was 10.8%. The mean of the method detection limits was $0.036{\mu}g/l$. From the results of analysis of real samples, it was confirmed that this method is useful to elucidate the concentration levels and the fate of chemicals in the aquatic environment.

  • PDF

기체크로마토그래피를 이용한 잔류농약 동시다성분 분석법 (Determination of Simultaneous Analytical Method of Residual Pesticides by Gas Chromatography)

  • 최원조;최계선;이희정;원영준;박흥재;김우성
    • 한국환경과학회지
    • /
    • 제18권12호
    • /
    • pp.1369-1381
    • /
    • 2009
  • The simultaneous determination of residual pesticides was developed using a gas chromatography. In this study, a simple and reliable methodology was improved to detect 175 kinds of residual pesticides by a liquid-liquid extraction procedure, followed by chromatographic analysis by gas chromatography. The 175 kinds of residual pesticides was classified into 4 groups according to the chemical structure, column type, resolution and sensitivity. The soybean sample selected for recovery experiment was not detected any pesticides. The recovery rates were ranged from 70.6% to 119.7% in most pesticides. The relative standard deviation (RSD 0.3~5.6%) was lower than 5.6% in all cases. The limits of detection (LOD) was lower than the maximum residue levels established by Korean legislations. The method has been successfully applied to the analysis of approximately 130 real samples.

진공차단기 3상 동시 차단시의 서지 특성 분석 (Surge Characteristics Analysis of Three-phase Virtual Chopping at Vacuum Circuit Breaker)

  • 김종겸
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1159-1164
    • /
    • 2018
  • Vacuum circuit breakers(VCB) are widely used for current interruption of high-voltage inductive loads such as induction motors. This VCB can be chopped off before the current zero due to its high arc-extinguishing capability. One of the outstanding features of VCB is that it can cut off high frequency re-ignition current more than other circuit breakers. If the transient recovery voltage generated in the arc extinguishing is higher than the dielectric strength of the circuit breaker, a re-ignition phenomenon occurs. The surge voltage of the re-ignition is very high in magnitude and the steepness of the waveform is so severe that it can act as a high electrical stress on the winding. If the high frequency current of one phase affects the other two phases when the re-ignition occurs, it may cause a high surge voltage due to the virtual current chopping. If the magnitude of the voltage allowed in the motor winding is high or the waveform level is too severe, it may lead to insulation breakdown. Therefore, it is necessary to reduce the voltage to within a certain range. In this study, we briefly explain the various phenomena at the time of interruption, analyzed the magnitude of the dielectric strength and the transient recovery voltage at the simultaneous three-phase interruption that can give the greatest influence to the inductive load, proposed a method to reduce the impact.

동시냉난방 열펌프의 전열회수 성능 특성에 관한 연구 (Experimental Study on the Performance of a Simultaneous Heating and Cooling Heat Pump in the Heat Recovery Mode)

  • 최종민;정현준;주영주;강훈;김용찬
    • 설비공학논문집
    • /
    • 제20권11호
    • /
    • pp.718-726
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Hence, the development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a simultaneous heating and cooling heat pump was investigated in the heat recovery mode (HR mode). The system adopted a variable speed compressor using R410A with four indoor units and one outdoor unit. In the HR mode, the capacity and COP were improved as compared with those in the cooling or heating mode because the waste heat in the outdoor unit was utilized as useful heat in the indoor units. However, energy imbalance between heating and cooling capacity of each indoor unit was observed in the 2H-1C HR mode. Therefore, the performance of the system in the 2H-1C HR mode was enhanced by controlling refrigerant flow rate through the outdoor unit.

A Recovery Technique Using Client-based Logging in Client/Server Environment

  • Park, Yong-Mun;Lee, Chan-Seob;Kim, Dong-Hyuk;Park, Eui-In
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.429-432
    • /
    • 2002
  • The existing recovery technique using the logging technique in the client/sewer database system only administers the log as a whole in a server. This contains the logging record transmission cost on the transaction that is executed in each client potentially and increases network traffic. In this paper, the logging technique for redo-only log is suggested, which removes the redundant before-image and supports the client-based logging to eliminate the transmission cost of the logging record. Also, in case of a client crash, redo recovery through a backward client analysis log is performed in a self-recovering way. In case of a server crash, the after-image of the pages which needs recovery through simultaneous backward analysis log is only transmitted and redo recovery is done through the received after-image and backward analysis log. Also, we select the comparing model to estimate the performance about the proposed recovery technique. And we analyzed the redo and recovery time about the change of the number of client and the rate of updating operation.

  • PDF

Spinal Subdural Hematoma Associated with Intracranial Subdural Hematoma

  • Kim, Myoung Soo;Sim, Sook Young
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권4호
    • /
    • pp.397-400
    • /
    • 2015
  • The simultaneous occurrence of an intracranial and a spinal subdural hematoma (SDH) is rare. We describe a case of cranial SDH with a simultaneous spinal SDH. An 82-year-old woman visited the emergency room because of drowsiness and not being able to walk 6 weeks after falling down. A neurological examination showed a drowsy mentality. Brain computed tomography showed bilateral chronic SDH with an acute component. The patient underwent an emergency burr-hole trephination and hematoma removal. She exhibited good recovery after the operation. On the fourth postoperative day, she complained of low-back pain radiating to both lower limbs, and subjective weakness of the lower limbs. Spine magnetic resonance imaging revealed a thoracolumbosacral SDH. A follow-up spinal magnetic resonance imaging study that was performed 16 days later showed a significant decrease in the size of the spinal SDH. We discuss the pathogenesis of this simultaneous occurrence of spinal and cranial SDH.

Simultaneous Determination of Cinnamaldehyde and Coumarin in Oryeong-san using HPLC with Photodiode Array Detector

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • 대한한의학방제학회지
    • /
    • 제18권2호
    • /
    • pp.251-257
    • /
    • 2010
  • Objectives : To develop and validate High-performance liquid chromatography-photodiode array methods for simultaneous determination of two constituents in Oryeong-san(ORS). Methods : Reverse-phase chromatography using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array(PDA) detection at 280 nm, were used for quantification of the two marker components of ORS. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was $H_2O$ and solvent B was acetonitrile. Results : Calibration curves were acquired with correlation coefficient ($r^2$)>0.9999, and the relative standard deviation(RSD) values(%) for intra- and inter-day precision were not exceed 1.0%. The recovery rate of each compound was in the range of 93.01-104.16%, with an RSD less than 2.0%. The contents of two compounds in ORS were 1.10-3.72 mg/g. Conclusions : The established HPLC method will be helpful to improve quality control of ORS.