• Title/Summary/Keyword: simultaneous monitoring

Search Result 311, Processing Time 0.031 seconds

Simultaneous Determination of Catecholamines, Serotonin and Their Metabolites in the Biological Sample Using HPLC/ECD (생체 시료 중 카테콜 아민류, 세로토닌 및 대사물질들의 HPLC/ECD 동시 정량분석)

  • Min, Ji-Hyun;Hahn, Young-Hee
    • YAKHAK HOEJI
    • /
    • v.55 no.4
    • /
    • pp.277-283
    • /
    • 2011
  • Simultaneous monitoring of catecholamines and serotonin with their appropriate extraction from the biological samples is required in order to understand thoroughly the regulation of the central and peripheral nervous system. In the present research the segmented gradient elution with the solid phase extraction using a C18 cartridge rather than the previous isocratic elution with alumina extraction is successfully employed to determine norepinephrine (NE), epinephrine (E), dopamine (DA), serotonin (5HT), 3,4-dihydroxyphenylacetic acid (DOPAC) and 5-hydroxyindoleacetic acid (5HIAA) simultaneously within 20 minutes using 3,4-dihydroxyhydrocinnamic aicd as the internal standard (IS). Linearities were obtained in the concentration range between $5{\times}10^{-6}M$ and $1{\times}10^{-4}M$ for all 7 compounds with detection limits of 0.6~1.9 ${\mu}M$. The present HPLC/ECD method yielded reasonable accuracy (relative error; -1.4~1.1%) and precision (relative standard deviation; 0.4~1.9%) for 9 measurements of the standard solution consisting of NE, E, DA, 5HT, DOPAC and 5HIAA compounds. Recoveries of catecholamines, serotonin and their metabolites from human serum were in the range of 57%~86%. While the concentrations of NE and 5HT in the serum of normal Sprague-Dawley rat were found as $1.4{\times}10^{-6}M$ and $2.6{\times}10^{-6}M$, respectively, the contents of NE and 5HT in the serum of the stressed rat were increased 5.6 times and 1.4 times more, respectively.

Simultaneous Analysis of Conazole Fungicides in Garlic by Q-TOF Mass Spectrometer Coupled with a Modified QuEChERS Method

  • Bong, Min-Sun;Yang, Si-Young;Lee, Seung-Ho;Seo, Jung-Mi;Kim, In-Seon
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.3
    • /
    • pp.323-329
    • /
    • 2011
  • BACKGROUND: The conazoles, difenoconazole, diniconazole, hexaconazole, penconazole and tetraconazole are a large class of synthetic fungicides used extensively for foliage and seed treatments in agricultural crops. The extensive use of conazoles has brought concerns on the potentiality of environmental contamination and toxicity. Thus studies on the development of methods for monitoring the conazoles are required. METHODS AND RESULTS: A modified quick, easy, effective, rugged and safe (QuEChERS) method was involved in sample preparation. Quadrapole time of flight mass spectrometer (Q-TOF MS) in electron spray ionization (ESI) mode was employed to determine conazoles in garlic samples. The limit of detection (LOD) and limit of quantification (LOQ) of conazoles by Q-TOF-MS ranged from 0.001 to 0.002 mg/L and 0.002 to 0.005 mg/L, respectively. Q-TOF-MS analysis exhibited less than 2.6 ppm error of accurate mass measurements for the detection of conazoles spiked at 0.05 mg/L in garlic matrix. Recovery values of conazoles fortified in garlic samples at 0.02, 0.05 and 0.1 mg/L were between 79.2 and 106.2% with a maximum 11.8% of standard deviation. No detectable conazoles were found in the domestic market samples by using the Q-TOF-MS method. CONCLUSION(s): High degree of confirmation for conazoles by accurate mass measurements demonstrated that Q-TOF-MS analysis combined with a QuEChERS method may be applicable to simultaneous determination of conazoles in garlic samples.

Phoswich Detector for Simultaneous Measuring Alpha/beta Particles (알파/베타선 동시측정용 phoswich 검출기)

  • Kim, Gye-Hong;Park, Chan-Hee;Lee, Kune-Woo;Jung, Chong-Hun;Seo, Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.2
    • /
    • pp.111-117
    • /
    • 2008
  • The new type phoswich detector consisting of the ZnS(Ag) and plastic scintillator for alpha/beta-ray simultaneous counting was developed for monitoring radiological contamination inside pipes. The detection performance was estimated using the PSD (pulse shape discrimination) method as a function of distance between the scintillator and radioactive source. The attenuation of particles traveling through a thin film for preventing the detector from being contaminated was experimentally estimated. It is concluded from our investigation that the phoswich detector developed can provide a sufficient alpha/beta-ray discrimination. The application of a thin film for preventing the detector from being contaminated was proven to be feasible.

  • PDF

Simultaneous Determination of Various Pesticides : Analysis Utilizing GC/MSD (SIM mode) (잔류농약 다성분 동시분석법 : GC-MSD (SIM mode)를 사용한 분석)

  • Rho, Kyoung-Ah;Kim, Hyeon-Wee;Lee, Yoon-Kyoung
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.721-727
    • /
    • 1998
  • An analytical method for simultaneous and rapid determination of organophosphorus, organochlorine, carbamate, and pyrethroid pesticides in polished rice was developed. The analysis is performed by gas chromatograph with mass selective detector (GC/MSD) in selected ion monitoring (SIM) mode. Pesticides were extracted from samples with acetone by automated Soxhlet apparatus and this extract was evaporated to dryness for the analysis. The residue was dissolved in hexane, followed by a treatment with a Sep-Pak florisil catridge. Pesticides were positively confirmed by GC/MS, retention times, and ion ratios. This analytical method allows a rapid, reliable, and a good recovery of hydrophilic pesticides. Except far captafol, captan, dichlofluanid and dichlorvos, recoveries of 42 pesticides were over 70%.

  • PDF

Power Monitoring System with Multiple Input Channels Using the Definition of IEEE Standard 1459-2010 (IEEE 1459-2010 규격의 정의를 이용한 다중 입력 채널을 갖는 전력 감시 시스템)

  • Jeon, Jeong-Chay;Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3100-3106
    • /
    • 2014
  • This paper develops power measurement system with multiple sensor input channels (voltage-8 channels and current-10 channels) that simultaneously can monitor power components for both supply and load side of power system. The hardware implementation of the proposed system is based on TMS320C42 DSP and signal processing program algorithm to calculate power components use the definition of IEEE Standard 1459-2010 related power quality. The performance of the developed system is tested by using standard ac power source device, and the test results showed that accuracy of the developed system is less than 0.2 %. Also, field test of the proposed system in the three-phase and four-wire power system was implemented. Simultaneous multiple channel measurement and analysis of power components in commercial and industrial electrical power system using the proposed system will be necessary to reduce power quality problems.

Development and Reliability Verification of Quality Control System for Compaction Grouting Method (컴팩션 그라우팅 공법의 품질관리 시스템 개발 및 신뢰성 검증)

  • Seo, Seok-Hyun;Lee, Jung-Sang;Jung, Eui-Youp;Park, Sang-Yeong;Lee, Hyo-Bum
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.4
    • /
    • pp.11-20
    • /
    • 2020
  • This study introduced the compact grouting method that can be used for improving soft ground and restoring buildings with unequal subsidence. The pump used in the traditional compact grouting method is a system that injects one hole each, which reduces the construction efficiency, and the analog injection method manually manages the construction by field workers, making it difficult to manage consistent quality. Pump and quality control system were developed to solve problems in existing construction. Since field supervisor determines amount of injected materials by using analog equipment and controls manually, it is difficult to manage consistent quality of construction. Therefore, the quality control system was developed in order to solve that problem. The quality control system consists of automatic mixing system of injection materials, multiple simultaneous injection pumps, and injection management monitoring system. Performance of the quality control system was verified through on-site testing, and ground improvement performance was verified through quality testing after testing and testing of the compact grouting method. Therefore, it is expected that the integrated quality control system developed will improve the quality assurance and efficiency and stability of construction at sites where construction and quality verification are difficult.

Combination of multiplex reverse transcription recombinase polymerase amplification assay and capillary electrophoresis provides high sensitive and high-throughput simultaneous detection of avian influenza virus subtypes

  • Tsai, Shou-Kuan;Chen, Chen-Chih;Lin, Han-Jia;Lin, Han-You;Chen, Ting-Tzu;Wang, Lih-Chiann
    • Journal of Veterinary Science
    • /
    • v.21 no.2
    • /
    • pp.24.1-24.11
    • /
    • 2020
  • The pandemic of avian influenza viruses (AIVs) in Asia has caused enormous economic loss in poultry industry and human health threat, especially clade 2.3.4.4 H5 and H7 subtypes in recent years. The endemic chicken H6 virus in Taiwan has also brought about human and dog infections. Since wild waterfowls is the major AIV reservoir, it is important to monitor the diversified subtypes in wildfowl flocks in early stage to prevent viral reassortment and transmission. To develop a more efficient and sensitive approach is a key issue in epidemic control. In this study, we integrate multiplex reverse transcription recombinase polymerase amplification (RT-RPA) and capillary electrophoresis (CE) for high-throughput detection and differentiation of AIVs in wild waterfowls in Taiwan. Four viral genes were detected simultaneously, including nucleoprotein (NP) gene of all AIVs, hemagglutinin (HA) gene of clade 2.3.4.4 H5, H6 and H7 subtypes. The detection limit of the developed detection system could achieve as low as one copy number for each of the four viral gene targets. Sixty wild waterfowl field samples were tested and all of the four gene signals were unambiguously identified within 6 h, including the initial sample processing and the final CE data analysis. The results indicated that multiplex RT-RPA combined with CE was an excellent alternative for instant simultaneous AIV detection and subtype differentiation. The high efficiency and sensitivity of the proposed method could greatly assist in wild bird monitoring and epidemic control of poultry.

Simultaneous Analysis of Prohibited Antibiotics (Fluoroquinolones) in Seawater and Effluents Released by Aquaculture Using LC-MS/MS (LC-MS/MS를 이용한 해수 및 수산용수 중 플루오로퀴놀론계 항생제 동시 분석법 정립)

  • Mikyoung Lee;In-Seok Lee;Minkyu Choi;Sunggyu Lee;Won-Chan Lee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.4
    • /
    • pp.428-437
    • /
    • 2023
  • A simultaneous analytical method was developed and validated for the analysis of prohibited fluoroquinolone (FQ) antibiotics including norfloxacin, ofloxacin, and pefloxacin, released by aquaculture in seawater and effluents. The samples were filtered, and extracts were obtained using a solid phase extraction cartridge with methanol (MeOH). The extracts were concentrated, and analyzed using ultra-performance liquid chromatography-tandem mass spectrometry. Two different columns and four different mobile phases were compared to achieve optimal separation and sensitivity for target compounds. Typical validation parameters including linearity, recovery of surrogate standard, instrument detection limit (IDL), limit of quantification (LOQ), and method detection limit (MDL) were evaluated. The linearity of calibration curves was over 0.999. Recoveries of surrogate ranged from 87.6% to 113%. The LOQ of target compounds was approximately 3-8 times lower than those reported in previous studies. The IDL and MDL were 0.06-0.57 and 0.06-0.37 ng/L, respectively. Seven effluent samples collected from an aquaculture located in Jeju were analyzed; however, not all target compounds were detected in the samples, suggesting that the banned antibiotics were not used. Overall, this established method was able to simultaneously analyze the three FQ antibiotics, and may be useful for monitoring prohibited antibiotics in the fishery industry.

Real-time Environmental Radiation Monitoring System with Automatic Restoration of Backup Data in Site Detector via Communication using Radio Frequency (현장검출기에 저장된 백업데이터를 무선통신방식으로 자동 복원하는 실시간 환경선량 감시 시스템)

  • Lee, Wan-No;Kim, Eun-Han;Chung, Kun-Ho;Cho, Young-Hyun;Choi, Geun-Sik;Lee, Chang-Woo;Park, Ki-Hyun;Kim, Yun-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.255-261
    • /
    • 2003
  • An environmental radiation monitoring system based on high pressurized ionization chamber has been used for on-line gamma monitoring surrounding the KAERI (Korea Atomic Energy Research Institute), which transmits the dose data measured from ion chamber on the site via radio frequency to a central processing computer and stores the transmitted real-time data. Although communication using radio frequency has several advantages such as effective and economical transmission, storage, and data process, there is one main disadvantage that data loss during transmission often happens because of unexpected communication problems. It is possible to restore the loss data by off-line such as floppy disk but the simultaneous process and display of current data as well as the backup data are very difficult in the present on-line system. In this work, a new electronic circuit board and the operation software applicable to the conventional environmental radiation monitoring system are developed and the automatical synchronization of the ion chamber unit and the central processing computer is carried out every day. This system is automatically able to restore the backup data within 34 hours without additional equipments and also display together the current data as well as the transmitted backup data after checking time flag.

Four multiplex PCR Sets of 11 LM Maize for LMO environmental monitoring in Korea (국내 LMO 자연환경 모니터링을 위한 11개 LM 옥수수의 동시검출기법 개발)

  • Shin, Su Young;Lim, Hae-Song;Seol, Min-A;Jung, Young Jun;Kim, Il Ryong;Song, Hae Ryoung;Lee, Jung Ro;Choi, Wonkyun
    • Journal of Plant Biotechnology
    • /
    • v.43 no.4
    • /
    • pp.473-478
    • /
    • 2016
  • With the increasing development and commercial use of genetically modified maize, it is essential to develop an appropriate method for detection of individual LMO (Living modified organism) events for monitoring the samples. In South Korea, commercial planting and accidental or unintentional releases of LMOs into the environment were not approved. In this study, to increase the efficiency of LMO detection, we developed simultaneous detection methods for 11 LM maize events. This multiplex PCR detection method is economical, as it saves time, cost and labor. We developed 11 individual LM maize events, and applied 4 multiplex PCR sets to the LM maize samples. These results are confirmed by applying the multiplex analysis of LMO environmental monitoring from 2012 to 2014, which represents the unintentionally released LM maize samples. The data were correlated with event specific PCR results. Our results indicate that the multiplex PCR method developed is suitable for detection of LM maize in LMO monitoring.