• Title/Summary/Keyword: silicone rubber membrane

Search Result 26, Processing Time 0.026 seconds

Preparation of Silicone Rubber Membrane and its Porosity (Silicone Rubber Membrane의 제조 및 기공특성)

  • Lee, Seung-Bum;Kim, Hyung-Jin;Hong, In-Kwon
    • Elastomers and Composites
    • /
    • v.30 no.3
    • /
    • pp.185-194
    • /
    • 1995
  • Membrane process has been employed to separate a specific substance from gas or liquid mixture, and treat wastewater. This is due to the fact that the substance of mixture can be permeated and separated selectively by membrane. Since Initial equipment and operation costs are not expensive, membrane process has been adopted in various fields such as petroleum Industry, chemistry, polymer, electronics, foods, biochemical industry and wastewater treatment. In this study, $CaCO_3$ particles impregnated in silicone rubber network were extracted by using supercritical carbon dioxide and pore distribution of silicone $rubber-CaCO_3$ was investigated with varying amount of extract. Silicone rubber has excellent mechanical properties such as heat-resistance, cold-resistance etc. and $CaCO_3$ has microporous structure. It is possible to make silicone $rubber-CaCO_3$ composite sheets via work-intensive kneading processes. In so doing $CaCO_3$ particles become distributed and impregnated in silicone rubber network. Supercritical carbon dioxide diffuse through composite sample, then sample is swollen. $CaCO_3$ in silicone rubber network Is dissolved in supercritical carbon dioxide, and its sites become pores. Pore distribution, pore shape and surface area are observed by SEM(scanning electron microscope) micrograph and BET surface area analyzer examination respectively. Pore characteristics of membrane suggest the possibilities that the membrane can be used for process of mixture separation and wastewater treatment.

  • PDF

Performance Test of Silicone Rubber Membrane by Gas Permeation Method (기체투과에 의한 Silicone Rubber Membrane의 기능성 시험)

  • Lee, Seung-Bum;Hong, In-Kwan
    • Elastomers and Composites
    • /
    • v.33 no.1
    • /
    • pp.37-43
    • /
    • 1998
  • The permeation of gas through polymer membrane at temperatures above its glass transition, generally occurs by a solution-diffusion mechanism. This mechanism is performed by the affinity difference between polymeric materials and gas molecules, and various technologies, such as copolymerization, impregnation and so on, have been researched to improve the affinity of polymeric material for the gases. In this study, permeability and selectivity for some gases were obtained from steady-state rates of gas permeation through silicone rubber membrane which is prepared by supercritical fluid extraction method. The permeability was measured by the volumetric method proposed by Barrer. Permeability was increased generally with temperature and permeation pressure. Silicone rubber membrane shows a higher permeability to $CO_2$ than to $O_2$, $N_2$. This results probably reflect the relatively high solubility of CO_2 in silicone rubber membrane, which is due to the affinity of $CO_2$ molecules. Since separation powers of $CO_2/N_2$, $CO_2/O_2$ were more than 200, and 100, respectively, it is able to separate $CO_2$ from the air, and the optimum temperature and pres-sure was 328.15 K, 60 cmHg respectively. In future, it is possible that the silicone rubber membrane can be used for separation or concentration of $CO_2$ through experiment for mixed gas separation.

  • PDF

Silicone Rubber Membrane Bioreactors for Bacterial Cellulose Production

  • Onodera, Masayuki;Harashima, Ikuro;Toda, Kiyoshi;Asakura, Tomoko
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.5
    • /
    • pp.289-294
    • /
    • 2002
  • Cellulose production by Acetobacter pasteurianus was investigated in static culture using four bioreactors with silicone rubber membrane submerged in the medium. The shape of the membrane was flat sheet, flat sack, tube and cylindrical balloon. Production rate of cellulose as well as its yield on consumed glucose by the bacteria grown on the flat type membranes was approximately ten-fold greater than those on the non-flat ones in spite of the same membrane thickness. The membrane reactor using flat sacks of silicone rubber membrane as support of bacterial pellicle can supply greater ratio of surface to volume than a conventional liquid surface culture and is promising for industrial production of bacterial cellulose in large scale.

Removal of a Heavy Metal from Wastewater using Membrane Process and Instrumental Analysis (Membrane 공정을 이용한 폐수로부터 중금속의 제거 및 기기분석)

  • Park, Kyung-Ai;Lee, Seung-Bum;Kim, Hyung-Jin;Hong, In-Kwon
    • Elastomers and Composites
    • /
    • v.30 no.3
    • /
    • pp.229-234
    • /
    • 1995
  • Membrane process has been applied widely to petroleum chemistry, fine chemistry, polymer, electronics, food, bioprocessing, and wastewater treatment process. Membrane process has advantage that there's no phase change through separation, energy consumption is smaller than other separation processes. And equipment investment and operation cost are inxpensive too. We prepared the silicone rubber membrane and then separated the heavy metal ion from wastewater. Silicone rubber membrane was prepared using a superitical fluid process and heavy metal ions were separated from the chromium nitrate, ferric sulfate, cupric sulfate, nickel sulfate aqueous solution. The pressure difference between top and bottom of separation apparatus was preserved by vacuum pump, and the removal amount of heavy metal at each separation step were analyzed by instrumental analysis, AAS. The surface and pore of silicone rubber membrane was investigated using SEM, and the capability of wastewater treatment using a silicone rubber membrane was proposed as calculated removal rate of heavy metal after comparing removal amount of heavy metal to amount of heavy metal in mother solution by AAS analysis.

  • PDF

Silicone Rubber Membrane-Based Chloride Ion-Selective Electrode (실리콘러버-지지체 염화이온선택성 막전극)

  • Sakong, Dong-Sik;Kim, Jin-Mog;Cha, Jin-Mog
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.12
    • /
    • pp.653-660
    • /
    • 1997
  • Silicone rubber-matrix membranes doped with tetradecyltrimethylammonium chloride (TDTMACl) are used to enhance electrode performance for chloride measurements in physiological samples. The optimized membrane formulation incorporates 95.4 wt% silicone rubber and 4.6 wt% TDTMACl, and its pH response is negligible in the range of pH 6-10. The TDTMACl-doped silicone rubber membrane exhibits sub-Nernstian response to chloride from 10 to 300 mM (-37.5 mV/decade), but its selectivities for chloride over other anions are remarkably enhanced: KpotCl,NO3=1.3, KpotCl,I=2.0, KpotCl,Sal=0.8, KpotCl,SCN=2.0 and KpotCl,ClO4=0.8. Furthermore, since the silicone rubber-matrix membrane exhibits better adhesion to the solid surface than do PVC membranes, the lifetime of the coated-wire type membrane electrode is greatly improved. The response properties toward chloride and salicylate for solid-state sensor are not significantly changed after at least 35 days of use.

  • PDF

Development of a Micro-pressure Sensor with high-resisting Pressure for Military Applications (군수용 고내압을 가지는 마이크로 압력센서의 개발)

  • Shim, Joon-Hwan;Seo, Chang-Taeg;Lee, Jong-Hyun
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1016-1021
    • /
    • 2005
  • A piezoresistive pressure sensor using a silicone rubber membrane has been fabricated on the selectively diffused (100)-oriented n/n+/n silicon substrates by a unique silicon micromachining technique using porous silicon ething. The width, length and thickness of the beam were 120${\mu}m$, 600${\mu}m$ and 7${\mu}m$, respectively and the thickness of the silicone rubber membrane was 40${\mu}m$. By the fusion of silicon beam and silicone rubber membrane, the mechanical strength of the pressure sensor could be highly improved due to smaller shear stress. The effectiveness of the sensor was confirmed through an experiment and FEM simulation in which the pressure sensor was characterized.

  • PDF

Membrane for the Removal of Volatile Organic Compounds from Air (대기중의 휘발성 유기물 제거용 분리막)

  • Deng, S.;Lang, K.;Wang, J.;Tremblay, A.;Matsuura, T.
    • Membrane Journal
    • /
    • v.7 no.1
    • /
    • pp.22-30
    • /
    • 1997
  • Porous asymmetric membranes were prepared from polyetherimide polymer by the phase-inversion technique under different conditions. The performance of the membranes was tested for the removal of acetone vapour from nitrogen. A membrane which showed a high acetone permeability and a high selectivity was chosen and tested further for the separation of different organic vapours from nitrogen. The molecular structure of organic vapours and the selectivity were correlated. A strong correlation was also found between the chromatographic retention time of the organic vapour and the selectivity. These experimental results led to the conclusion that the sorption is the factor governing the separation of volatile organic compounds from nitrogen. A membrane was also prepared by coating the surface of a porous polyetherimide membrane with silicone rubber. The performance of membranes with and without silicone rubber coating was compared.

  • PDF

Design and fabrication of a comb-type differential pressure sensor with silicon beams embedded in a silicone rubber membrane (실리콘 빔이 실리콘 고무 멤브레인에 삽입된 빗살형 차압센서의 설계 및 제조)

  • Park, Jeong-Yong;Kong, Sung-Soo;Seo, Chang-Taeg;Shin, Jang-Kyoo;Koh, Kwang-Rak;Lee, Jong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.424-429
    • /
    • 2000
  • A novel differential pressure sensor has been developed with silicon beams embedded in a silicone rubber membrane. The transducer is usable for most applications involving exposure to harsh media. A piezoresistive differential pressure sensor using silicone rubber membrane has been fabricated on the selectively diffused (100)-oriented n/n+/n silicon substrates by a unique silicon micro-machining technique using porous silicon etching. The pressure sensitivity is about $0.66\;{\mu}V/mmHg$ and the non-linearity is less than 0.1%.

  • PDF

가스상 TCE 처리를 위한 추출막 생물반응기의 수학적 모사

  • Kim, Ji-Seok;Kim, Gwan-Su;Jang, Deok-Jin
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.370-373
    • /
    • 2000
  • In this work, an extractive membrane bioreactor containing coulture broth of Burkholderia cepacia G4 PR1 constitutively expressing the TCE-degrading enzyme, tolune-ortho-monooxygenase(TOM), was used for the degradation of TCE. The membrane bioreactor operates by seperating the TCE-containing waste gas from the aerated biomedium, by which the air-stripping of TCE without degradation was overcome that could occur in conventional aerobic biological treatments of TCE-contaminated waste gases. This was achieved by a silicone rubber membrane which was coiled around a perspex draft tube. TCE from the gas phase diffuses across the silicone rubber membrane into microbial culture broth that was continuously fed from a separate aerobic CSTR. Therefore, TCE degradation occured without the TCE being directly exposed to the aerating gas stream. Of the TCE supplied to the membrane bioreactor, 72.6% was biodegraded during the operation of this system. To construct a mathematical model for this system, parameters describing microbial growth kinetics on TCE were determined using a CSTR bioreactor. Else parameters used for numerical simulation were determined from either indepedent experiments or values reported in the literature. The model was compared with the experimental data, and there was a good agreement between the predicted and the measured TCE concentrations in the system. To achieve a higher treatment efficiency, various operating conditions were simulated as well.

  • PDF

In Vitro Test of a Micro Syringe Fabricated for the Intravascular Injection (초소형 주사 시스템의 모의 혈관 내에서의 작동 시험)

  • Kim, Geun-Young;Sim, Woo-Young;Lee, Sang-Woo;Yang, Sang-Sik;Chang, Jun-Keun;Lee, Seung-Ki
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.6
    • /
    • pp.307-313
    • /
    • 2001
  • A micro syringe which can be attached to the end of a micro intravascular endoscope for drug injection is fabricated and its characteristic is tested. The syringe consists of a drug chamber and an actuator chamber which are separated by a silicone rubber membrane. The drug chamber is filled with liquid drug by the membrance actuation caused by the vaporization and condensation of the working liquid in the actuator chamber. The liquid drug is ejected by the electrolysis of the working liquid. The membrane deflection by each actuation method has been measured. The liquid ejection image has been captured during the electrolysis of the electrolyte. Also, the successful operation of the micro syringe under the normal blood pressure was verified.

  • PDF