• Title/Summary/Keyword: signed distance

Search Result 54, Processing Time 0.025 seconds

Comparison of clinical and histological characteristics of orthodontic tooth movement into recent and healed extraction sites combined with corticotomy in rats

  • Samruajbenjakun, Bancha;Kanokpongsak, Kaviya;Leethanakul, Chidchanok
    • The korean journal of orthodontics
    • /
    • v.48 no.6
    • /
    • pp.405-411
    • /
    • 2018
  • Objective: This study was performed to investigate the rate of tooth movement and histological characteristics of extraction sockets those were subjected to corticotomy. Methods: A split-mouth randomized controlled trial experiment was designed. Thirty-two adult, male Wistar rats were divided into 2 groups: healing extraction socket (H) and recent extraction socket (R); these groups were randomly classified into 4 subgroups (0/7/21/60 days). The first maxillary molar was extracted on 1 side and 2 months were allowed for complete bone healing; then, the corresponding molar was extracted on the other side and surgical intervention was performed at the mid-alveolar point of the first maxillary molar. Ten grams of continuous force was applied. The outcomes measured were rate of tooth movement, percentage of periodontal space and histological evaluation. The rate of tooth movement was calculated as the measured distance divided by the duration of molar movement. Histomorphometric evaluations were performed on the second and third maxillary molars. The Wilcoxon signed rank test was used to compare differences between the two groups. Results: There were no significant differences in the rates of tooth movement between H and R groups at any of the 4 time points. The histological appearance and percentage of periodontal space between the R and H groups also demonstrated no significant differences. Conclusions: The rates of orthodontic tooth movement into recent and healed socket sites did not differ between the groups. Histological analysis of tooth movement revealed regional acceleration during every time period.

Enhanced Dual Contouring method by using the Feature of Spherical Coordinate System (구면 좌표계의 특성을 이용한 듀얼 컨투어링 기법 개선)

  • Kim, Jong-Hyun;Park, Tae-Jung;Kim, Chang-Hun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.17 no.2
    • /
    • pp.27-36
    • /
    • 2011
  • The Dual Contouring method has an advantage over the primal polygonization methods like the Marching Cube method in terms of better expression of sharp features. In this paper, the Dual Contouring method is implemented in Spherical coordinates, not the Cartesian ones to examine some characteristics. For this purpose, our octree is defined in Spherical coordinates, which is called "S-Octree". Among some characteristics, the proposed Dual Contouring method in the S-Octree tends to produce less vertices at the same octree level. In particular, for any surface models close to surface sphere, the generated mesh surfaces are smoother and more detailed than those of the Cartesian Dual Contouring approach for specific applications including mesh compression where available geometric information is quite limited.

Skeletal and dentoalveolar changes after miniscrew-assisted rapid palatal expansion in young adults: A cone-beam computed tomography study

  • Park, Jung Jin;Park, Young-Chel;Lee, Kee-Joon;Cha, Jung-Yul;Tahk, Ji Hyun;Choi, Yoon Jeong
    • The korean journal of orthodontics
    • /
    • v.47 no.2
    • /
    • pp.77-86
    • /
    • 2017
  • Objective: The aim of this study was to evaluate the skeletal and dentoalveolar changes after miniscrew-assisted rapid palatal expansion (MARPE) in young adults by cone-beam computed tomography (CBCT). Methods: This retrospective study included 14 patients (mean age, 20.1 years; range, 16-26 years) with maxillary transverse deficiency treated with MARPE. Skeletal and dentoalveolar changes were evaluated using CBCT images acquired before and after expansion. Statistical analyses were performed using paired t-test or Wilcoxon signed-rank test according to normality of the data. Results: The midpalatal suture was separated, and the maxilla exhibited statistically significant lateral movement (p < 0.05) after MARPE. Some of the landmarks had shifted forwards or upwards by a clinically irrelevant distance of less than 1 mm. The amount of expansion decreased in the superior direction, with values of 5.5, 3.2, 2.0, and 0.8 mm at the crown, cementoenamel junction, maxillary basal bone, and zygomatic arch levels, respectively (p < 0.05). The buccal bone thickness and height of the alveolar crest had decreased by 0.6-1.1 mm and 1.7-2.2 mm, respectively, with the premolars and molars exhibiting buccal tipping of $1.1^{\circ}-2.9^{\circ}$. Conclusions: Our results indicate that MARPE is an effective method for the correction of maxillary transverse deficiency without surgery in young adults.

The Immediate Effect of the Backward Walking Exercise and Verbal Command on the Forward Head Posture of College Students in their 20s (뒤로 걷기 운동과 언어 지시가 20대 대학생들의 앞쪽 머리 자세에 미치는 즉각적인 효과)

  • Park, Han-kyu;Kim, Tae-ho;Kim, Dong-woo
    • Physical Therapy Korea
    • /
    • v.27 no.3
    • /
    • pp.185-190
    • /
    • 2020
  • Background: Backward walking exercise may offer some unique and potentially beneficial differences compared with forward walking exercise. There is still a lack of research on backward walking exercises and forward head posture. Objects: The purpose of this study was to determine the effect of backward walking exercise on college students forward head posture in their 20s. Methods: Twenty-one subjects participated in the experiment. The subjects were those with a craniovertebral angle (CVA) of 55 degrees or less who understood the purpose and method of this study and voluntarily agreed. A camera capable of taking pictures of the lateral plane was installed at a distance of 1.5 meters before exercising. Pictures were taken before walking backward, and after walking for 15 minutes on the treadmill, the images were taken in the same way. The composition of the backward walking exercise was walking at a rate of 1.0 for 5 minutes, and the remaining 10 minutes were walking at a rate of 1.5. Wilcoxon signed rank test was used to compare CVA and craniorotational angle (CRA) before and after exercise. Results: As a result of this study, there was a significant difference in CVA before and after exercise (p < 0.05). There was a significant difference in CRA before and after exercise (p < 0.05). Conclusion: The backward walking exercise and verbal command seems to have positively influenced the changes in CVA and CRA among college students in their 20s. It seems that studies to confirm balance or muscle activity as well as changes in forward head posture through the long-term intervention of the backward walking exercise should be conducted.

CUDA-based Object Oriented Programming Techniques for Efficient Parallel Visualization of 3D Content (3차원 콘텐츠의 효율적인 병렬 시각화를 위한 CUDA 환경 기반 객체 지향 프로그래밍 기법)

  • Park, Tae-Jung
    • Journal of Digital Contents Society
    • /
    • v.13 no.2
    • /
    • pp.169-176
    • /
    • 2012
  • This paper presents a parallel object-oriented programming (OOP) platform for efficient visualization of three-dimensional content in CUDA environments. For this purpose, this paper discusses the features and limitations in implementing C++ object-oriented codes using CUDA and proposes the solutions. Also, it presents how to implement a 3D parallel visualization platform based on the MVC (Model/View/Controller) design pattern. Also, it provides sample implementations for integral MLS (iMLS) and signed distance fields (SDFs) based on the Marching Cubes and Raytracing. The proposed approach enables GPU parallel processing only by implementing simple interfaces. Based on this, developers can expect general benefits that are common in general OOP techniques including abstractization and inheritance. Though I implemented only two specific samples in this paper, I expect my approach can be widely applied to general computer graphics problems.

Dynamic Object Tracking of a Quad-rotor with Image Processing and an Extended Kalman Filter (영상처리와 확장칼만필터를 이용한 쿼드로터의 동적 물체 추종)

  • Kim, Ki-jung;Yu, Ho-Yun;Lee, Jangmyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.7
    • /
    • pp.641-647
    • /
    • 2015
  • This paper proposes a new strategy for a quad-rotor to track a moving object efficiently by using image processing and an extended Kalman filter. The goal of path planning for the quad-rotor is to design an optimal path from the start point to the destination point. To lengthen the freight time of the quad-rotor, an optimal path is required to reduce the energy consumption. To track a moving object, the mark signed on the moving object has been detected by a camera mounted first on the quad-rotor. The center coordinates of the mark and its area are calculated through the blob analysis which is one type of image processing. The mark coordinates are utilized to obtain information on the motion direction and the area of the mark is utilized to recognize whether the object moves backward or forward from the camera on the quad-rotor. In addition, an extended Kalman filter has been applied to predict the direction and speed of the dynamically moving object. Through these schemes, it is aimed that the quad-rotor can track the dynamic object efficiently in terms of flight distance and time. Through the two different route freights of the quad-rotor, the performance of the proposed system has been demonstrated.

Development Plan for the First GMT ASM Reference Body

  • Yang, Ho-Soon;Oh, Chang-Jin;Biasi, Roberto;Gallieni, Daniele
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.76.3-77
    • /
    • 2021
  • GMT secondary mirror system consists of 7 segmented adaptive mirrors. Each segment consists of a thin shell mirror, actuators and a reference body. The thin shell has a few millimeters of thickness so that it can be easily bent by push and pull force of actuators to compensate the wavefront disturbance of light due to air turbulence. The one end of actuator is supported by the reference body and the other end is adapted to this thin shell. One of critical role of the reference body is to provide the reference surface for the thin shell actuators. Therefore, the reference body is one of key components to succeed in development of GMT ASM. Recently, Korea Research Institute of Standards and Science (KRISS) and University of Arizona (UA) has signed a contract that they will cooperate to develop the first set of off-axis reference body for GMT ASM. This project started August 2021 and will be finished in Dec. 2022. The reference body has total 675 holes to accommodate actuators and 144 pockets for lightweighting. The rear surface has a curved rib shape with radius of curvature of 4387 mm with offset of 128.32mm. Since this reference body is placed just above the thin shell so that the front surface shape needs to be close to that of thin shell. The front surface has a concave off-axis asphere, of which radius of curvature is 4165.99 mm and off-axis distance is about 1088 mm. The material is Zerodur CTE class 1 (CTE=0.05 ppm/oC) from SCHOTT. All the actuator holes and pockets are machined normal to the front surface. It is a very complex challenging optical elements that involves sophisticated machining process as well as accurate metrology. After finishing the fabrication of reference body in KRISS, it will be shipped to UA for final touches and finally sent to Adoptica in Italy, in early 2023. This paper presets the development plan for the GMT ASM Reference Body and relevant fabrication and metrology plans.

  • PDF

Performance Improvement of SE-MMA Adaptive Equalization algorithm by Selective Updating (Selective Updating에 의한 SE-MMA 적응 등화 알고리즘의 성능 개선)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.101-106
    • /
    • 2016
  • This paper proposes the SU-SE-MMA algorithm which applying the concept of selective updaing to the SE-MMA that is possible to reduce the intersymbol interference due to distortion occurred at the channel when transmit the nonconstant modulus 16-QAM signal. The SE-MMA emerged for the simplifying the computational operation from the current MMA adaptation algorithm, then it's has the fast convergence speed and has a problem of increase the residual component in the steady state. The SU-SE-MMA performs the selectively tap updating when the distance of equalizer output and specified transmit signal point is greater than the given threshold value and tap updaing does not occurred in the small distance. By this selective updating process, it is possible to more reduction in the computational operation in the propose algorithm. The improved adaptive equalization performance of SU-SE-MMA like as the equalizer output signal constellation, residual isi, MD, SER were confirmed by computer simulation compared to SE-MMA. As a result of simulation, the AV-SE-MMA has better performance in output signal constellation, residual isi and MD compared to the SE-MMA, but it was confirmed that the AV-SE-MMA has similar in the SER performance that means the robustness to the noise.

Visual Feedback System for Manipulating Objects Using Hand Motions in Virtual Reality Environment (가상 환경에서의 손동작을 사용한 물체 조작에 대한 시각적 피드백 시스템)

  • Seo, Woong;Kwon, Sangmo;Ihm, Insung
    • Journal of the Korea Computer Graphics Society
    • /
    • v.26 no.3
    • /
    • pp.9-19
    • /
    • 2020
  • With the recent development of various kinds of virtual reality devices, there has been an active research effort to increase the sense of reality by recognizing the physical behavior of users rather than by classical user input methods. Among such devices, the Leap Motion controller recognizes the user's hand gestures and can realistically trace the user's hand in a virtual reality environment. However, manipulating an object in virtual reality using a recognized user's hand often causes the hand to pass through the object, which should not occur in the real world. This study presents a way to build a visual feedback system for enhancing the user's sense of interaction between hands and objects in virtual reality. In virtual reality, the user's hands are examined precisely by using a ray tracing method to see if the virtual object collides with the user's hand, and when any collision occurs, visual feedback is given through the process of reconstructing the user's hand by moving the position of the end of the user's fingers that enter the object through sign distance field and reverse mechanics. This enables realistic interaction in virtual reality in real time.

Effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs (성견에서 골형성단백질이 코팅된 임플란트가 치조골 증대에 미치는 영향)

  • Park, Chan-Kyung;Kim, Jong-Eun;Shin, Ju-Hee;Ryu, Jae-Jun;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.202-208
    • /
    • 2010
  • Purpose: This study was aimed to evaluate the effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs. Materials and methods: Six Beagle dogs were used in this study. Six 8.0 mm long anodized surface titanium implants were placed 5 mm into the mandibular alveolar ridge following 6 month of healing period after extraction. Each animal received three implants coated with rhBMP-2 and three uncoated control implants using the randomized split-mouth design. Radiographic examinations were undertaken immediately at implant placement (baseline), at weeks 4 and 8 after implant placement. The amount of bone augmentation was evaluated by measuring the distance from the uppermost point of the coverscrew to the marginal bone. Implant Stability Quotient (ISQ) values were measured immediately at implant placement and 8 weeks after implant placement. For the statistical analysis, Man-Whitney ranksum test and Wilcoxon signed rank test of SPSS 12.0 software were used (P=.05). Results: The BMP group exhibited radiographic vertical bone augmentation about $0.6{\pm}0.7$ mm at 8 weeks later while controls showed bone loss about $0.4{\pm}0.6$ mm. There was significant difference among the rhBMP-2 group and controls in bone level change (P<.05). The ISQ values were significantly higher in the BMP-2 group than the control group at 8 weeks later (P<.05), while there was no significant difference at surgery. Conclusion: Within the limitation of this study, the rhBMP-2 coated on anodized implant could stimulate vertical alveolar bone augmentation, which may increase implant stability significantly on completely healed alveolar ridge.