• Title/Summary/Keyword: signal-to-noise ratio(SNR)

Search Result 1,132, Processing Time 0.028 seconds

Multi frequency band noise suppression system using signal-to-noise ratio estimation (신호 대 잡음비 추정 방법을 이용한 다중 주파수 밴드 잡음 억제 시스템)

  • Oh, In Kyu;Lee, In Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.2
    • /
    • pp.102-109
    • /
    • 2016
  • This paper proposes a noise suppression method through SNR (Singal-to Noise Ratio) estimation in the two microphone array environment of close spacing. The conventional method uses a noise suppression method for a gain function obtained through the SNR estimation based on coherence function from full band. However, this method cause performance decreased by the noise damage that affects all the feature vector component. So, we propose a noise suppression method that allocates a frequency domain signal into N constant multi frequency band and each frequency band gets a gain function through SNR estimation based on coherence function. Performance evaluation of the proposed method is shown by comparison with PESQ (Perceptual Evaluation of Speech Quality) value which is an objective quality evaluation method provided by the ITU-T (International Telecommunications Union Telecommunication).

A Design of SINR Measurement Unit for IEEE 802.16m (IEEE 802.16m 시스템의 SINR 측정기의 설계)

  • Kim, Jun-Woo;Park, Youn-Ok;Kim, Whan-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.12A
    • /
    • pp.1097-1104
    • /
    • 2010
  • This paper presents the signal-to-noise ratio (SNR) and signal-to-interference plus noise ratio (SINR) estimation based on A-Preamble of IEEE 802.16m IMT-Advanced WiMax system with simulation results. The downlink signal of IEEE 802.16m has two kinds of A-Preambles: the PA-Preamble and the SA-Preamble. This paper proposes the effective method of estimating SNR and SINR with A-Preambles, and also shows that this method can recognize the ICI(Inter-Carrier-Interference) occurrence due to doppler frequency. With the recognition of ICI, the mobile station can save the power by operating 1-tap equalizer in usual cases, and activating ICI mitigation module only when it perceives the ICI occurrence.

Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol (흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교)

  • Lee, Won-Jeong;Ahn, Bong-Seon;Park, Young-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • The purpose of this study was to compare radiation dose and image quality between low-dose (LDP) and standard-dose protocol (SDP). LDP (120 kVp, 30 mAs, 2-mm thickness) and SDP (120 kVp, 180 mAs, 1.2-mm thickness) images obtained from 61 subjects were retrospectively evaluated at level of carina bifurcation, using multi-detector CT (Brilliance 16, Philips Medical Systems). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated at ascending aorta and infraspinatus muscle, from CT number and back-ground noise. Radiation dose from two protocols measured at 5-point using acrylic-phantom, and CT number and noise measured at 4-point using water-phantom. All statistical analysis were performed using SPSS 19.0 program. LDP images showed significantly more noise and a significantly lower SNR and CNR than did SDP images at ascending aorta and infraspinatus muscle. Noise, SNR and CNR were significantly correlated with body mass index (p<0.001). Radiation dose, SNR and CNR from phantom were significant differences between two protocols. LDP showed a significant reduction of radiation dose with a significant change in SNR and CNR compared with SDP. Therefore, exposure dose on LDP in clinical applications needs resetting highly more considering image quality.

Signal-to-noise ratio enhancement of ultrasonic signal by using constant frequency-to-bandwidth ratio decomposition method (비대역폭 분할 방법을 이용한 초음파 신호의 S/N 비 개선)

  • 김태현;구길모;고대식;전계석
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.5
    • /
    • pp.50-57
    • /
    • 1994
  • In the non-destructive evaluation techniques using ultrasonic signal, backscattering noise from grain interface decreases the SNR of received signal. In this paper, SSP(split-spectrum processing) based on the constant FBR decomposition method has been applied to enhance the SNR. This algorithm helps to find optimal parameters of filter bank through a simple theory and has an advantage that reduce the signal processing time compared with the conventional constant bandwidth decomposition method. In this experiment, the 304 stainless steel sample is heat-treated and received ultrasonic signal is processed by SSP using the constand bandwidth decomposition method and the constand FBR decomposition method enhanced the SNR by 1.4 dB and reduced the required number of filters by 4 compared with the constant bandwidth decomposition method.

  • PDF

The Simulation of 747 Curve for Hard Disk Drive System (하드 디스크 드라이브 시스템의 747 곡선 시뮬레이션)

  • 서정교;조순철;김용수;박노열
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.2
    • /
    • pp.97-102
    • /
    • 1997
  • Off-track capability is used to determine the track pitch of hard disk drive system, and the off-track capability as a function of track pitch is called 747 curve. In this paper, 747 curves were simulated with computer. Side reading and recording parameters were obtained by magnetic field analysis using 3-D finite element method. Head read signal and noise voltages for calculation of signal to noise ratio (SNR) were obtained using reciprocity theorem. According to the 747 curves thus obtained, the off-track capability was increased as erase band width increased and as effective signal to noise ration $(SNR_{eff}}$ decreased. A simulated 747 curve and a measured 747 curve (using spin stand) of a planar silicon head with track width of 4.1 um were very similar, which indicated that the simulation was carried out properly.

  • PDF

Application of LLR on Cooperative Communications for Wireless Relay Networks (무선 중계 네트워크의 협력 통신 방법에 대한 LLR 적용 연구)

  • Khuong Ho Van;Kong Hyung-Yun;Lee Dong-Un
    • The KIPS Transactions:PartC
    • /
    • v.13C no.5 s.108
    • /
    • pp.601-606
    • /
    • 2006
  • Decode-and-forward cooperative communications protocol (DFP) allows single-antenna users in wireless medium to obtain the powerful benefits of multi-antenna systems without physical antenna arrays. For this protocol, so far the relays have used SNR to evaluate the reliability of the received signal before deciding whether to forward the decoded data so as to prevent their unsuccessful detection. However, SNR only characterizes the long-term statistic of Gaussian noise and thus leading to inaccurate assesment. Therefore, we propose using log-likelihood ratio (LLR) which accounts for the instantaneous noise in the received signal as an alternative to SNR. A variety of simulation results reveal the significant superiority of the SNR-based DFP to the SNR-based DFP regardless of threshold level and relay position under the flat Rayleigh fading channel plus AWGN (Additive White Gaussian Noise).

Implementation of SNR Estimator for ISDB-T Systems (ISDB-T 시스템을 위한 SNR 추정기 구현)

  • Kim, Seongihl;Sohn, Chae-Bong
    • Journal of Broadcast Engineering
    • /
    • v.18 no.6
    • /
    • pp.927-934
    • /
    • 2013
  • This paper aims to realize a Signal to Noise Ratio Estimator which constitutes a critical index of the broadcasting system in OFDM system with a synchronized type based on ISDB-T system. Of the elements which are comprising OFDM segments of ISDB-T system using the MSE algorithm suitable for ASIC design owing to its low complexity among a diverse SNR estimation methods, SNR estimation method using the broadcasting information data and the SNR estimation method using scattered pilot signal were realized by RTL. These two methods were compared in terms of their performance through simulation test not only in the AWGN channel which is an ideal channel, but also in SFN channel and frequency selective fading channel, which are distorted channels. Complexity of two methods were also compared through RTL realization. As a result of this comparison analysis, it was concluded that the SNR estimation method using scattered pilot signal shows more excellent performance and easiness in realization.

Performance estimation of the noise reduction by window function on a single tone (단일 신호에 대한 창 함수의 잡음 제거 성능 평가)

  • Baek, Moon-Yeol;Kim, Byoung-Sam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.5
    • /
    • pp.38-43
    • /
    • 1996
  • Windowing routines have as their purpose the reduction of the sidelobes of a spectral output of the FFT or DFT routines. Windowing routines accomplish this by forcing the beginning and end of any sequence to approach each other in value. Since they must work with any sequence they force the beginning and ending samples near zero. To make up for this reduction in power, windowing routines give extra weight to the values near the middle of the sequence. The difference between windows is the way in which they transition from the low weights near the edges to the higher weights neqr the middle of the sequence. Signal-to-noise ratio(SNR) can be determined by the ratio of the output noisy signal variance to the input noisy signal variance of a window. Standard deviation of noise is reduced by windowing. Thus, the windowing operation improved the SNR of the noisy signal. This paper shows a performance estimation of windowing on a single tone with added Gaussian noise and uniform noise.

  • PDF

The Effect of Signal-to-Noise Ratio on Sentence Recognition Performance in Pre-school Age Children with Hearing Impairment (청각장애 유소아의 신호대소음비에 따른 문장인지 능력)

  • Lee, Mi-Sook
    • Phonetics and Speech Sciences
    • /
    • v.3 no.1
    • /
    • pp.117-123
    • /
    • 2011
  • Most individuals with hearing impairment have difficulty in understanding speech in noisy situations. This study was conducted to investigate sentence recognition ability using the Korean Standard-Sentence Lists for Preschoolers (KS-SL-P2) in pre-school age children with cochlear implants and hearing aids. The subjects of this study were 10 pre-school age children with hearing aids, 12 pre-school age children with cochlear implants, and 10 pre-school age children with normal hearing. Three kinds of signal-to-noise (SNR) conditions (+10 dB, +5 dB, 0 dB) were applied. The results for all pre-school age children with cochlear implants and hearing aids presented a significant increase in the score for sentence recognition as SNR increased. The sentence recognition score in speech noise were obtained with the SNR +10 dB. Significant differences existed between groups in terms of their sentence recognition ability, with the cochlear implant group performing better than the hearing aid group. These findings suggest the presence of a sentence recognition test using speech noise is useful for evaluating pre-school age children's listening skill.

  • PDF

De-Noising of Electroretinogram Signal Using Wavelet Transforms (웨이브렛 변환을 이용한 망막전도 신호의 잡음제거)

  • Seo, Jung-Ick;Park, Eun-Kyoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.203-207
    • /
    • 2012
  • Purpose: Electroretinogram(ERG) signal noise as well as conducting other bio-signal measurement were generated. It was intened to enhance the accuracy of retinal-related diagnosis with removing signal noise. Methods: Sampling signal was made with generating 60 Hz noise and white noise. The noise were removed using wavelet transforms and bandpass filter. De-noising frequency was compared with Fourier transform spectrum. Removed noises were compared numerically using SNR(signal to noise ratio). Results: The result compared Fourier transform spectrum was showed that 60 Hz noise removed completely and most of white noise was removed by wavelet transforms. 60 Hz and the white noise remained using bandpass filters. The result compared SNR showed that wavelet transforms was 22.8638 and bandpass filter was 4.0961. Conclusions: Wavelet transform showed less signal distortion in removing noise. ERG signal is expected to improve the accuracy of retinal-related diagnosis.