• Title/Summary/Keyword: signal tube

Search Result 318, Processing Time 0.026 seconds

Design of an integrated multiple-single-channel analyzer

  • Jie Yang;Xiaofei Gu;Shuxiang Lu;Guoheng Zheng
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2557-2562
    • /
    • 2024
  • A type of integrated multiple-single-channel analyzer (IMSCA) is described. The IMSCA works with an input pulse of 2-20 pC, and it can be directly connected to a scintillation detector, which eliminates the need for a linear amplifier. It consists of 64 input ports, so 1-64 detectors can be set by users according to different requirements. Two energy regions for each input channel can be simultaneously analyzed. Another advantage of the IMSCA is that it integrates with a high-speed pulse signal acquisition card and transmits data to the computer through the network. The maximum pulse through-rate is 1.4 MHz, and linearity can reach 0.1%. This IMSCA has been successfully used in enrichment detecting of nuclear fuel rod.

A novel approach to the classification of ultrasonic NDE signals using the Expectation Maximization(EM) and Least Mean Square(LMS) algorithms (Expectation Maximization (EM)과 Least Mean Square(LMS) algorithm을 이용하여 초음파 비파괴검사 신호의 분류를 하기 위한 새로운 접근법)

  • Daewon Kim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.1
    • /
    • pp.15-26
    • /
    • 2003
  • Ultrasonic inspection methods are widely used for detecting flaws in materials. The signal analysis step plays a crucial part in the data interpretation process. A number of signal processing methods have been proposed to classify ultrasonic flaw signals. One of the more popular methods involves the extraction of an appropriate set of features followed by the use of a neural network for the classification of the signals in the feature space. This paper describes an alternative approach which uses the least mean square (LMS) method and expectation maximization (EM) algorithm with the model based deconvolution which is employed for classifying nondestructive evaluation (NDE) signals from steam generator tubes in a nuclear power plant. The signals due to cracks and deposits are not significantly different. These signals must be discriminated to prevent from happening a huge disaster such as contamination of water or explosion. A model based deconvolution has been described to facilitate comparison of classification results. The method uses the space alternating generalized expectation maximization (SAGE) algorithm In conjunction with the Newton-Raphson method which uses the Hessian parameter resulting in fast convergence to estimate the time of flight and the distance between the tube wall and the ultrasonic sensor Results using these schemes for the classification of ultrasonic signals from cracks and deposits within steam generator tubes are presented and showed a reasonable performances.

  • PDF

Detection of Irradiated Chicken, Pork and Beef by ESR Spectroscopy (닭고기, 돼지고기 및 쇠고기의 방사선 조사 유무 판별을 위한 ESR Spectroscopy의 활용)

  • Yang, Jae-Seung;Kim, Choong-Ki;Lee, Hae-Jung
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.606-611
    • /
    • 1999
  • To identify irradiated foods, studies have been carried out with electron spin resonance (ESR) spectroscopy on bone containing foods, such as chicken, pork, and beef. Bones cleaned, pieced and dried were irradiated with doses of 0, 1, 3, 5 kGys using a $Co^{60}$ irradiator. The bones were placed in a resonant quartz tube with an internal diameter of about 4.0 mm within the Bruker Win-ESR spectrometer, and the intensity of the ESR signal could be quantified by double integration of the first derivative spectrum. The irradiated bone presented an asymmetric absorption in shape, different from that of an unirradiated one. It could be possible to detect at doses lower than 1 kGy below the dose employed commercially (3 kGy) in the case of irradiated chicken bone. The signal intensity was greatest in the beef bone, intermediate in the pork bone and lowest in the chicken bone; it was normally lower for smaller animals than for larger species, and small variations were observed between samples of the same species. The intensity of the signal induced in bones increased linearly with irradiation doses in the range of 1.0 kGy to 5.0 kGy, and it was possible to distinguish between samples given low and high doses of irradiation. The signal stability for 6 weeks made them ideal for the quick and easy identification of irradiated meats.

  • PDF

A Study on Signal Analysis of the Data Aquisition System for Photosensor (데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구)

  • Hwang, InHo;Yoo, Sun Kook
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.237-242
    • /
    • 2016
  • The major advantage of slip-ring technology in Spiral CT is that it facilitates continuous rotation of the x-ray tube, so that volume data can be acquired from a patient quickly. Not only for such a fast scan, but also for the dose reduction purpose, high signal-to-noise ratio and fast data acquisition system is required. In this study, we have built a multi-channel photodetector and multi-channel data acquisition system for CT application. The detector module consisted of CdWO4 crystal and Si photodiode in 16 channels. For the performance test of the preamplifier stage, both the transimpedance and switched integrator types are optimized for the photodetector modules. Switched integrator showed better noise performance in the limited bandwidth which is suitable for the current CT application. The control sequence for data acquisition and 20 bit ADC is designed with VHDL(Very High Speed Integrated Circuit Hardware Description Language) and implemented on FPGA(Field Programmable Gate Array) chip. Our Si photodiode detector module coupled to CdWO4 crystal showed comparable signal with other commercially available photodiode for CT. Switched integrator type showed higher SNR but narrower bandwidth compared to transimpedance preamplifier. Digital hardware is designed by FPGA, so that the control signal could be redesigned without hardware alteration.

Finite Element Analysis of Eddy Current Testing for Tubes with 3-Dimensional Defects (3차원 관결함에 대한 와전류탐상의 유한요소해석)

  • Lee, Hyang-Beom;Won, Sung-Yean;Shin, Young-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.3
    • /
    • pp.191-199
    • /
    • 2000
  • In this paper, a numerical analysis using the finite element method (FEM) is presented which models the eddy current testing (ECT) of tubes with 3-dimensional defects. For the description of 3-dimensional eddy current problems, the governing equation is derived from the Maxwell's equations. The 3-dimensional FEM formulation with hexahedral elements is carried out using the Galerkin weighted residual method. The INCONEL 600 steam generator tube with inner and outer diameter defects is adopted for the numerical analysis, and the ECT signal, which is the trajectory of the probe impedance, is calculated. For the verification of the numerical analysis method, results of numerical calculations and experiments are compared and they show good agreements. Based on this verification, several defect signals are predicted and their characteristics are investigated with the variation in the defect depth and the circumferential angle of the defect.

  • PDF

Dynamic Lung Compliance in Normal Subjects Measured by Pneumatograph (Pneumotachograph 로 측정한 건강인의 동적 폐 Compliance)

  • 이성행
    • Journal of Chest Surgery
    • /
    • v.10 no.2
    • /
    • pp.195-204
    • /
    • 1977
  • Dynamic lung compliance was measured in healthy ten young[mean age, 26 years] male and five young[mean age, 25 years] female. Lung volume was integrated of the rate of flow signal which was obtained by using pneumotachograph and differential pressure transducer[PM 5, Statham]. Intrapleural pressure was measured as that of intraesophagel pressure. Esophageal ballon, 15. 5cm in length, 4ml of luminal capacity and made of thin latex, was connected to the polyethylene tube that had 12-14 side holes and was of 1.5mm of ID. Transpulmonary pressure was traced by means of differential pressure transducer[PM 131, Statham] to which connected the esophageal balloon catheter and connection tube from mouth piece. Lung volume and transpulmonary pressure were photographed by cathode ray oscilloscope camera while the subjects were breathing spontaneously. Dynamic lung compliance loop was displayed on single trace monitor and subtraction was performed for the quasi-static hysteresis. Dynamic lung compliance was measured, 1. by plotting the pressure-volume relationship 2. from the subtracted pressure-volume loop. Results were as follows. 1. Dynamic lung compliances measured by plotting of healthy young male and female were $0.202{\pm}0.06$ and $0.190{\pm}0.023L/cm$ $H_2O$ respectively. 2. When measured from subtraction loop, dynamic lung compliance for male and female were $0.327{\pm}0.107$, and $0.27{\pm}0.06L/cm$ $H_2O$ respectively. 3. Dynamic chest wall and total respiratory system compliance were also measured. 4. Dynamic lung compliance by plotting appeared to be essentially same when compared to that of static compliance reported previously from our laboratory, however, that obtained from subtraction loop revealed higher values than the compliances obtained by plotting and that of static compliance.

  • PDF

Application of Dual Tree Complex Wavelet for Performance Improvement of CT Images (CT 영상의 화질개선을 위한 이중트리복합웨이블릿의 적용)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.941-946
    • /
    • 2019
  • Computed tomography (CT) has been increasing in frequency and indications for use in clinical diagnosis and treatment decisions. Multidetector CT has the advantage of shortening the inspection time and obtaining a high resolution image compared to a single detector CT, but has been pointed out the disadvantage of increasing the radiation exposure. In addition, when the low tube voltage is used to reduce the exposure dose in the CT, noise increases relatively. In the existing method, the method of finding the optimal image quality using the method of adjusting the parameters of the image reconstruction method is not a fundamental measure. In this study, we applied a double-tree complex wavelet algorithm and analyzed the results to maintain the normal signal and remove only noise. Experimental results show that the noise is reduced from 8.53 to 4.51 when using a complex oriented 2D method with 100kVp and 0.5sec rotation time. Through this study, it was possible to remove the noise and reduce the patient dose by using the optimal noise reduction algorithm. The results of this study can be used to reduce the exposure of patients due to the low dose of CT.

Development and Performance Test of TWTA Maintenance System for the Low Altitude Surveillance Radar (저고도 탐지레이더용 진행파관증폭기 정비시스템 개발 및 성능시험 연구)

  • Yoon, In-Chul;Yun, Seok-Jin;Kwon, Jong-Won;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.6
    • /
    • pp.43-50
    • /
    • 2010
  • In this paper, the TWTA (Traveling Wave Tube Amplifier) maintenance system for the low altitude surveillance Radar was developed using the embedded Linux system, and its superiority was demonstrated through the performance test. Nowadays, the necessity of maintenance system and reliability testing on military equipments has been increasing steadily. In addition, nonlinear characteristics of the maintenance system for the low altitude surveillance Radar are more likely to have serious problems as well as to slow down durability. Therefore, after analyzing characteristics of RF input-output signal and TWTA, we designed interface circuits between the TWTA equipment and the embedded Linux system. The Linux kernel on the system was optimized to improve the efficiency and reliability. And our new TWTA maintenance system was evaluated in the real field. As a result, the proposed system was contented with desired specifications, and demonstrated military's fighting capabilities. Therefore, our novel system will advance military maintenance technology and will help to develop similar equipments.

Compensation of Nonlinear Distortion Using a Predistorter Based on Real-Valued Fixed Point Iterations in MC-CDMA Systems (MC-CDMA 시스템에서 실수 고정점 반복 기반의 전치왜곡기를 이용한 비선형 왜곡 보상)

  • Jeon, Jae-Hyun;Shin, Yoan-Shin;Im, Sung-Bin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • We propose a predistorter to compensate for nolinear distortion induced by a high power amplifier employed in multi carrier-code division multiple access (MC-CDMA) systems. The proposed scheme rests upon the fixed point iteration (FPI) associated with the contraction mapping theorem. Unlike the predistorter based on the FPI already presented by the authors in other literatures which operates on complex-valued modulation signals, the proposed predistorter in this paper deals with real-valued FPI on modulation signal amplitudes, resulting in less complexity. Simulation results on a BPSK-modulated, 64-subcarrier synchronous MC-CDMA baseband system with a traveling wave tube amplifier in the transmitter, indicate that the proposed predistorter achieves significant improvement in terms of bit error rate and total degradation over those without the predistorter. Moreover, the proposed predistorter outperforms the complex-valued counterpart, in particular, for small output back-off levels.

  • PDF

Feasibility Study of Remote Field Eddy Current Testing for Nonmagnetic Steam Generator Tubes (비자성 증기발생기 전열관의 원격장와전류 탐상 가능성 연구)

  • Shin, Young-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.518-525
    • /
    • 2001
  • As steam generator (SG) tubes have aged, new and subtle flaws have appeared. Most of them start growing from outside the tubes. Since signals from outer diameter (OD) defects are very weak compared to those from inner diameter (ID) defects in the conventional eddy current testing due to skin effect, this paper studies the feasibility of using remote field eddy current (RFEC) technique, which has shown equal sensitivity to ID and OD defects in the ferromagnetic pipe inspection. Finite element modeling studies show that the operating frequency needs to be increased up to a few hundred kHz in order for RFEC effects to occur in the nonmagnetic SG tube. The proper distance between exciter and sensor coils is also found to be about 1.5 OD, which is half the distance used in the ferromagnetic pipe inspection. Defect signals obtained by the designed RFEC probe show equal sensitivity to ID and OD defects and the existence of linear relationship between defect depth and phase signal strength. These results tell us that RFEC inspection is feasible even in nonmagnetic steam generator tubes.

  • PDF