• 제목/요약/키워드: side of angle

검색결과 1,329건 처리시간 0.023초

프론트 사이드 멤버의 경사 충돌 성능 (Crash Performance of Front Side Member Impacted with Angle)

  • 강성종
    • 한국자동차공학회논문집
    • /
    • 제22권2호
    • /
    • pp.52-59
    • /
    • 2014
  • Front impacted SUV vehicle shows that the front parts of side members are collapsed by the bending due to the transverse load exerted at the end of side members. Side member models were impacted with various angles in order to study the crash performance according to the impact angle. Even for the small impact angle of $10^{\circ}$, crash performance seriously deteriorated and the deformations for impact angle $15^{\circ}$ were similar to those from the front body impact analysis. In addition, the angled front impact analysis for the straight member with hat section was carried out and the effects of inner reinforcement shape on crash performance was investigated.

Side Slip Angle Based Control Threshold of Vehicle Stability Control System

  • Chung Taeyoung;Yi Kyongsu
    • Journal of Mechanical Science and Technology
    • /
    • 제19권4호
    • /
    • pp.985-992
    • /
    • 2005
  • Vehicle Stability Control (VSC) system prevents vehicle from spinning or drifting out mainly by braking intervention. Although a control threshold of conventional VSC is designed by vehicle characteristics and centered on average drivers, it can be a redundancy to expert drivers in critical driving conditions. In this study, a manual adaptation of VSC is investigated by changing the control threshold. A control threshold can be determined by phase plane analysis of side slip angle and angular velocity which is established with various vehicle speeds and steering angles. Since vehicle side slip angle is impossible to be obtained by commercially available sensors, a side slip angle is designed and evaluated with test results. By using the estimated value, phase plane analysis is applied to determine control threshold. To evaluate an effect of control threshold, we applied a 23-DOF vehicle nonlinear model with a vehicle planar motion model based sliding controller. Controller gains are tuned as the control threshold changed. A VSC with various control thresholds makes VSC more flexible with respect to individual driver characteristics.

편마비 환자의 골반경사 각도에 따른 하지체중지지 및 체중이동에 관한 연구 (A Study on Weight Bearing and Weight Shifting of Lower Extremity According to the Pelvic Tilt Angle in Hemiplegic Patients)

  • 서규원;권춘숙;신홍철
    • 대한물리치료과학회지
    • /
    • 제2권3호
    • /
    • pp.609-622
    • /
    • 1995
  • The purpose of this study was l)to compare a pelvic tilt angle between sound side and affected side in hemiplegic patients, 2)to determine the difference of weight bearing and weight shifting between sound and affected lower extremity according to the pelvic tilt angle. The subject for the study were 40 hemiplegic patients(mean age of 55.6 years)without orthopedic disability on pelvic bone. The data were analyzed by t-test, one way ANOVA, Multiple comparison and Range. The results of this study were as follows : 1. There was a significant difference in the pelvic tilt angle between sound side and affected side in hemiplegic patients(p<0.05). 2. There was a significant difference in the weight bearing value between sound and affected side in hemiplegic patients according to the posterior pelvic tilt angle(F = 12.43, df = 3/36, p<0.001). Therefore, the lesser the posterior pelvic tilt angle, the higher the weight bearing value on the affected side. 3. The lesser the posterior pelvic tilt angle, the higher the weight shifting value on the affected side. 4. There was a significant difference in weight bearing value between sound and affected side according to the grade spasticity(F = 3.61, df = 4/35, p<0.05). Therefore, the higher the grade spasticity, the lower the weight bearing value on affected side.

  • PDF

신호교차로 안전성향상을 위한 단속카메라의 효과분석 연구 -측면직각 충돌사고를 중심으로- (Effect Analysis on Red Light Camera for Signalized Intersection Safety -Focused on Side Right-Angle Collision Accidents-)

  • 오주택;김용석;이용철
    • 한국도로학회논문집
    • /
    • 제17권1호
    • /
    • pp.119-127
    • /
    • 2015
  • PURPOSES : Before-and-after studies of red light cameras were conducted with the aim of reducing the number of side right-angle collisions. Three different methods were used for the before-and-after studies, and the analysis results were compared. METHODS : This research used the naive before-and-after method, the comparison-group method, and the empirical Bayes method to study the effects of red light cameras on side-angle collisions. The results of the three before-and-after methods were compared and interpreted in terms of safety indications at signalized intersections. RESULTS : The research results showed that side right-angle collisions can be reduced by installing red light cameras at signalized intersections. All three methods guarantee safety improvements of 25~30% on average. With regard to the results of each method, the naive before-and-after method, the comparison-group method, and the empirical Bayes method showed safety improvements of 25.6%, 27.8%, and 29.7%, respectively. CONCLUSIONS : It was concluded that red light cameras are an effective countermeasure to improve intersection safety. In particular, by installing red light cameras, side right-angle collisions can be reduced by up to approximately 25~30%.

뇌졸중환자 내측 비복근의 초음파 영상 분석 (The Analysis of Ultrasonography on Gastrocnemius Medialis of Patient with Stroke)

  • 서삼기
    • The Journal of Korean Physical Therapy
    • /
    • 제19권2호
    • /
    • pp.11-19
    • /
    • 2007
  • Purpose: The purpose of this study were to analyze ultrasonography on both sides of gastrocnemius medialis of stroke patient. Methods: In fourteen subjects with stroke, the gastrocnemius medialis(GM) muscle were scanned with ultrasonography at the muscle belly at rest at ankle angles of 0 degree (neutral position) and it were measured with ultrasonography on both sides of the leg. Muscle architecture (thickness, pennation angle, fascicle length, density, white area index) was examined using real-time B-mode ultrasonography with 7.5MHz linear-array prob. Results: Thickness of non-paratic side was significantly thicker than paratic side. Pennation angle of non-paratic side was significantly larger than paratic side. Fascicle length of non-para tic side was significantly smaller than paratic side. Density of non-paratic side was significantly smaller than paratic side. White area index of non-paranc side was significantly smaller than paratic side. Conclusion: This study showed that stroke have influenced on mechanical properties and quality properties of skeletal muscle architecture.

  • PDF

하악각 골절 술후 발생한 비대칭의 하악각 축소술을 이용한 교정 증례 (A Case Report: Correction of Facial Asymmetry using Mandible Angle Ostectomy in Patient with Previous Mandible Fracture)

  • 김연환;이학승;김정태
    • 대한두개안면성형외과학회지
    • /
    • 제11권1호
    • /
    • pp.45-48
    • /
    • 2010
  • Purpose: After surgical interventions of mandible fractures, facial asymmetry can be occurred, and it leads to serious problems for patients. This can be solved by mandible angle ostectomy. Methods: A 19-year-old male underwent percutaneous surgical intervention for left mandibular angle and right parasymphyseal fractures 3.5 years ago. The left angle was protruded compared to the other side. Using a percutaneous approach, $4.5{\times}1cm$ sized piece of mandible angle was sawed off. For the right angle, intraoral approach was performed for angle ostectomy, and the angle was sawed off by a size of $4{\times}1cm$, using a pattern based on the piece from the left side. Results: After surgery, no complications such as subcondylar fractures, refractures, insufficient corrections, secondary angle formations, hematomas, and transient nerve palsies were seen, and symmetric correction of mandible angles were done. Conclusion: In facial asymmetries due to mandibular fractures, mandible ostectomy could be a solution. Using the bone section from the contralateral side, measurement of the amount of bone sawed off was possible, and via percutaneous approach on the previously operated site with simultaneous scar revision, and intraoral approach for the contralateral side, cosmetically satisfactory result was obtained.

시상정중면에서 하악우각부 사이의 각도와 하악과두장축의 수평경사도간의 상호관계 (INTERRELATION BETWEEN THE ANGLE FORMED BY THE MIDSAGITTAL PLANE AND THE MANDIBULAR ANGLE AND THE HORIZONTAL INCLINATION OF THE CONDYLAR LONG AXIS)

  • 오완수;최순철
    • 치과방사선
    • /
    • 제22권1호
    • /
    • pp.109-116
    • /
    • 1992
  • 저자는 경북대학교 치과대학 학생중 악관절의 기능장애의 병력 및 현증이 없고 안모가 단정한 정상인 56명을 대상으로 시상정중면에서 양측의 하악우각부사이의 각도와 하악과두장축의 수평경사도를 계측하여 통계학적으로 분석한 바 다음과 같은 결과를 얻었다. 1. 시상정중면에서 하악우각부 사이의 각도는 우측이 18.50±1.48°, 좌측이 19.30±1.55°였다. 2. 하악과두장축의 수평경사도는 우측이 19.25±7.56°, 좌측이 20.27±7.05°였다. 3. 두 각도간의 관계는 우측의 경우 y=20. 31-0.0094×(r=-0 482, p<0.01), 좌측의 경우 y=20.64-0.066×(r=-0.301, p<0.05)인 것으로 나타났다(y : 하악과두장축의 수평경사도, x : 시상정중면에서 하악우각부 사이의 각도).

  • PDF

직경 및 문합각도가 단측 문합의 컴플라이언스 및 응력분포에 미치는 영향 (The Effect of the diameter and anastomotic angles on the compliance and the stress distribution of the end-to-side anastomosis)

  • 한근조;김영호;김현수;안성찬;장우석
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.334-337
    • /
    • 1997
  • Von Mises stress and compliance distribution was evaluated using a finite element analysis on the end-to-side anastomosis of an artery with length of $20\sim24mm$, inner diameter of 4mm, thickness of 0.5mm and a PTFE graft with length of 10mm, inner diameter of 2mm, thickness of 0.2mm when the anastomotic angle was taken from $30^{\circ}\sim90^{\circ}$ in every $10^{\circ}$ and the diameter ratio from $0.1\sim1$ in every 0.1. The inner pressure of $1330dyne/mm^2$ was applied inside the 2 conduits. It was found that the compliance whose magnitude is larger on the acute angle anastomotic side than on the acute angle side became larger as the anastomotic angle became smaller and the diameter ratio larger and that the equivalent stress on the acute angle anastomotic side was larger than that on the abtuse angle side and became larger as the anastomotic angle and the diameter ratio became larger.

  • PDF

Research on Grid Side Power Factor of Unity Compensation Method for Matrix Converters

  • Xia, Yihui;Zhang, Xiaofeng;Ye, Zhihao;Qiao, Mingzhong
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1380-1392
    • /
    • 2019
  • Input filters are very important to matrix converters (MCs). They are used to improve grid side current waveform quality and to reduce the input voltage distortion supplied to the grid side. Due to the effects of the input filter and the output power, the grid side power factor (PF) is not at unity when the input power factor angle is zero. In this paper, the displacement angle between the grid side phase current and the phase voltage affected by the input filter parameters and output power is analyzed. Based on this, a new grid side PF unity compensation method implemented in the indirect space vector pulse width modulation (ISVPWM) method is presented, which has a larger compensation angle than the traditional compensation method, showing a higher grid side PF at unity in a wide output power range. Simulation and experimental results verify that the analysis of the displacement angle between the grid side phase current and the phase voltage affected by the input filter and output power is right and that the proposed compensation method has a better grid side PF at unity.

편마비 환자에 있어서 Bobath Approach가 골반경사각도 변화에 미치는 영향 (Change of the Pelvic Tilt Angle on Bobath Approach in Hemiplegic Patients)

  • 서규원;배성수;신홍철
    • 대한물리치료과학회지
    • /
    • 제3권1호
    • /
    • pp.855-861
    • /
    • 1996
  • The purpose of this study was to compare a pelvic tilt angle between sound side and affected side in hemiplegic patients and the changing affected pelvic posterior tilt angle was measured at intervals of 3, 6, 9 weeks after Bobath approach. The subject for the study were 10 hemiplegic patients(mean age of 54.1 years)without orthopedic disability on pelvic bone. The data were analyzed by t-test, one-way ANOVA. The results of this study were as follows. There was a significant difference in the pelvic tilt angle between sound side and affected side in hemiplegic patients. There was a significant difference in affected pelvic posterior tilt angle between pre-treatment and post-treatment(9 weeks).

  • PDF