• Title/Summary/Keyword: shunt index

Search Result 37, Processing Time 0.044 seconds

Optimization of the Anastomosis Angle and Diameter with the Systemic- To-Pulmonary Artery Shunt (대동맥-폐동맥 연결관의 접합각도와 직경의 최적화)

  • Kim, Sung-Min;Park, Sung-Yun;Jun, Jae-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.10
    • /
    • pp.123-130
    • /
    • 2007
  • Hypoplastic left heart syndrome is currently the most lethal cardiac malformation of the newborn infant. Survival following a Norwood operation depends on the balance between systemic and pulmonary blood flow, which is highly dependent on the fluid dynamics through the interposition shunt between the two circulations. The purpose of this study is an optimization of the systemic-to-pulmonary artery shunt. In this study, We used computational fluid dynamic(CFD) models to determine the velocity profile in a systemic-to-pulmonary artery shunt and suggested a simplified method of calculating the blood flow in the shunt based on Ultrasound systems. We analyzed the flow characteristic variations and oscillatory shear index(OSI) due to the anastomosis angle and shunt diameter changing. Four different CFD models were constructed with the shunt sizes ranging from 3 to 3.5mm. The angle between the brachiocephalic trunk(BCT) and the shunt were $30^{\circ}$ and $45^{\circ}$, respectively. When the diameter is 3.0 mm, the oscillatory shear index decreased by 1.2% at $30^{\circ}$ as opposed to at $45^{\circ}$. When the diameter is 3.5 mm, it increased by 18% more at $30^{\circ}$ as opposed to at $45^{\circ}$. When the joint angle is $30^{\circ}$ and the diameter is 3.0 mm, the oscillatory shear index decreased by 4.1% in comparison with the 3.5 mm diameter. When the angle is $45^{\circ}$ and the diameter is 3.0 mm, the index increased by 14.6% in comparison with the 3.5 mm diameter.

A Study on Growth of Pulmonary Artery after Modified Blalock-Taussig Shunt in Tetralogy of Fallot (Fallot 4 징증에서 변형 Blalock Taussig 수술후 폐동맥성장에 관한 연구)

  • Yang, Tae-Bong;O, Bong-Seok;Lee, Dong-Jun
    • Journal of Chest Surgery
    • /
    • v.21 no.1
    • /
    • pp.10-16
    • /
    • 1988
  • Ten patients with tetralogy of Fallot were studied angiocardiographically before a modified Blalock-Taussig shunt and again 25*3.2 months after the previous shunt. All of ten patients had patent previous shunt at the time of follow up examination. Pre-and postoperative diameters of left and right pulmonary artery and descending aorta were measured and pulmonary artery index [the sum of the crossectional areas of the right and left pulmonary arteries standardized by the body surface area] was calculated. The ratio of mean diameter of left and right pulmonary arteries to the diameter of the descending aorta [LPA+RPA/2xDA] was increased postoperatively by 0.20*0.068 [p=0.020]. Mean PAI [pulmonary artery index] increased from 283.8*178.4 mm/m2 BSA to 345.8~144.5 mm/m2 BSA after shunt operation [p=0.019]. This results suggested that the modified Blalock-Taussig shunt was effective to help growth of the pulmonary arteries in most cases of the study populations but the ones with the PAI>233mm*/m* BSA appeared less benefited by Blalock Taussig shunt. Calculation of PAI could be an aid to making a decision whether to perform a one stage corrective surgical procedure or a palliative shunt procedure in the patient with small pulmonary arteries.

  • PDF

Improvement of Modulation Index in 3-phase Inverters using Shunt Resistors (션트저항을 이용한 3상 인버터의 전압 변조지수 증대)

  • Kim, Jung-Dae;Choi, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.374-382
    • /
    • 2018
  • This paper has done a hardware-based approach to increase the modulation index in 3-phase inverters, unlike the conventional software algorithm-based approaches. The minimum required time to measure the currents in a three-phase inverters with shunt resistors has also been analyzed. By the analysis, the longest time in minimum required time is AD conversion time. To shorten the minimum required time, this paper proposed a sample-and-hold(S/H) circuit implemented at the inverter current signal output to retain the current signal. When the linear operation region of an inverter with S/H was compared with that without it, the modulation index was increased by 7.8 %. Inverters with S/H circuits can employ the traditional software algorithms, such as the voltage injection method or current restoration method, and it will yield further increase the modulation index.

Transcolonic scintigraphy for diagnosis of canine portosystemic shunts

  • Lee, Young-won
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.2
    • /
    • pp.390-393
    • /
    • 1999
  • Transcolonic scintigraphy using $^{99m}Technetium$ pertechnetate ($^{99m}TcO_{4}$) was performed in 5 dogs with portosystemic shunts. In all dogs, the activity in the heart was seen before liver activity. Also time activity curve was revered. The mean shunt index in 5 dogs was 82.3% (range 79.6~87.1%). Transcolonic scintigraphy is quick, simple and useful diagnostic method for canine portosysternic shunts.

  • PDF

Design of piezoelectric Shunt Structure using Admittance Analysis with Application to O.D.D. Main Base (어드미턴스를 이용한 압전 션트 구조물의 설계방법과 O.D.D. 메인 베이스로의 응용)

  • Park, Jong-Sung;Lim, Soo-Cheol;Choi, Seung-Bok;Kim, Jae-Hwan;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.403-406
    • /
    • 2004
  • In this paper, the design of damped structures associated with the piezoelectric shunt circuits is undertaken and it is applied to optical disk drive (O.D.D) main base in order to reduce unwanted vibration. In order to design effective piezoelectric structure, the admittance of the structure is introduced as the performance index of the piezoelectric shunt system. And the admittance offset of the shunt performance is theoretically investigated. It is also presented that the admittance can be calculated by commercial finite elements program. To verify the admittance calculated by F.E.M, admittance measurement is performed by impedance analyzer. In this verifying process, the validity of the finite element admittance analysis is found. As a practical approach, to reduce the vibration of the O.D.D. main base, piezoelectric shunt system is designed using the proposed admittance analysis and shunt effect is evaluated at all prescribed frequencies.

  • PDF

On-line coordination control of OLTC and Switched Shunt for enhancement of stability using local data in substation (변전소내 지역정보를 이용하여 안정도 향상을 위한 실시간 OLTC 및 커패시터 협조제어 알고리즘)

  • Kang, Sang-Gyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.7
    • /
    • pp.119-125
    • /
    • 2012
  • This paper suggest the on-line coordination control between on-load tap changers and Switched Shunts for ensuring the voltage stability using local data obtained from one substation. Inappropriate control of on-load tap changers that are able to maintain voltage profile might cause unintended result that is harmful to system stability, especially voltage stability. This paper utilizes Z-index that could inform the whole system condition from only one substation data. Simulation is performed using the HYPERSIM that is a digital simulator and matlab simulink to confirm the proposed algorithm.

Analysis of Current Sensing Method using Three Shunt Resistor for Synchronous Motor Drive (Three Shunt Resistor를 이용한 동기 전동기 구동 방법 분석)

  • Shin, Seung-Min;Park, Rae-Kwan;Lee, Byoung-Kuk;Gu, Bon-Gwan;Choi, Jun-Hyuk
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.306-307
    • /
    • 2010
  • 본 논문에서는, 동기 전동기 구동을 위해 Three Shunt Resistor를 이용하여 전류를 피드백 받는 방법에 대하여 분석한다. 특히 Three Shunt Resistor를 이용하여 전류를 피드백 받는 경우 Modulation Index (MI)의 크기에 따라 피드백 받은 상전류 정보의 왜곡이 발생하는 문제점에 대하여 분석하고 이를 해결하기 위한 새로운 방법을 제안하며, 컴퓨터 시뮬레이션을 통하여 검증한다.

  • PDF

Clinical Study on Risk Factors of Hydrocephalus after Aneurysmal Subarachnoid Hemorrhage (뇌동맥류 파열에 의한 지주막하 출혈 후 수두증 발생의 위험 인자에 대한 임상 연구)

  • Choi, Jeong-Jae;Koh, Hyeon-Song;Cho, Jun-Hee;Kim, Seon-Hwan;Youm, Jin-Young;Song, Shi-Hun;Kim, Youn
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.12
    • /
    • pp.1375-1380
    • /
    • 2001
  • Objective : The authors analyzed the incidence, the cause and the prognosis of hydrocephalus following aneurysmal subarachnoid hemorrhage to evaluate the risk factors of hydrocephalus and to provide the proper treatment method for hydrocephalus following aneurysmal subarachnoid hemorrhage. Methods : The 505 cases of subarachnoid hemorrhage followed by aneurysmal surgery from January 1990 to May 1999, were divided into shunt group and shunt-free group and we were reviewed for the clinical status, Fisher's grade, brain CT findings and prognosis. Results : The incidence of acute hydrocephalus was 37.2% of patients and 18.9% to developed chronic hydrocephalus. Shunt surgery due to chronic hydrocephalus was required in 6.5% of patients. We found following variables were significantly related to shunt-dependent hydrocephalus : high Hunt-Hess and Fisher grade, initial CT findings of intraventricular hemorrahge, posterior circulation aneurysm, preoperative rebleeding, delayed ischemic deficits, and initial high ventricular size index. There were no statistically significant relationships between shunt-dependent hydrocephalus and patient age or sex, timing of operation. The previous hypertension was not related to shunt dependent hydrocephalus. Prognosis in shunt group showed poor result. Conclusion : The risk factors of hydrocephalus following aneurysmal subarachnoid hemorrhage are high Hunt-Hess grade, high Fisher's grade, aneurysms of posterior circulations, preoperative aneurysmal rebleeding, delayed ischemic deficits, initial CT findings of intraventricular hemorrahge and initially increased ventricular size. The patients with these factors should the carefully observed and managed accordingly due to poor prognosis related to hydrocephalus requiring shunt operation.

  • PDF

The Clinical Analysis of Modified B-T Shunt Using 3 mm and 3.5 mm PTFE graft (3mm와 3.5mm PTFF graft를 이용한 변형 B-T 단락술의 임상적 분석)

  • 정성호;윤태진;임한중;민경석;서동만;윤소영;김영휘;고재곤;박인숙
    • Journal of Chest Surgery
    • /
    • v.33 no.9
    • /
    • pp.716-722
    • /
    • 2000
  • Background: Modified Blalock-Taussig shunt using 3mm or 3.5mm PTFE graft has been performed in patients with small body weight or in candidates for single ventricle palliation. However, there are few reports concerning clinical outcomes in terms of pulmonary artery growth and shunt patency rate after shunt operations using such a small graft. Material and Method: Twenty-five patients rate after shunt operations using 3 or 3.5 mm sized grafts from September 1996 to August 1999. We retrospectively assessed the pulmonary artery growth and the shunt patency rate by reviewing the pre-and post-operative pulmonary angiograms. The risk factors for late death and second shunt operations were also analyzed. To assess the presence of any correlation between body weight and selection of the graft size, regression analysis was done in 81 cases of shunt operations performed during the same period. Result: There were 1(4%) early death and 5(20%) late deaths. The survivors were followed up for an average of 7.34 months. The pulmonary artery index increased significantly from 129$\pm$66$\textrm{mm}^2$/$m^2$ to 213$\pm$114 $\textrm{mm}^2$/$m^2$(p=0.002). The shunt patency rate assessed at postoperative 2, 4, 6 and 8 months were 82.5%, 77%, 73% and 42% respectively with a marked decline between 6 and 8 months. Asplenia was a frequent finding for the patients with late death although the incidence failed to reach statistical significance(p=0.078). Pre-operative diagnosis of PA with VSD was found to be a statistically significant risk factor for a second shunt operation(p=0.01). Body weight(a) at operation and graft size(b) used in the shunt operations revealed strong correlation and could be expressed by the following formula; b=0.128a + 3.233. Conclusion: Adequate growth of pulmonary artery and satisfactory early patency rate could be obtained by modified Blalock-Taussing shunt using 3mm or 3.5mm graft. However, during 6 to 8 months after shunt operations, the patency rate fell sharply, which implicates that close observation and early intervention are mandatory in this period.

  • PDF

The Study on the drug pharmacokinetics according to the progression of liver disease

  • Sohn, Soo-Jung;Choi, Hong-Serck;Ahn, Mee-Ryung;Chung, Hye-Joo;Yoo, Tae-Moo;Lee, Min-Ho;Park, Moon-Seung;Shin, In-Chul;Kim, Ju-ll
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.308.1-308.1
    • /
    • 2003
  • We underwent this study to know correlation between the amount of portosysternic shunt/hepatic fibrosis and bioavailability parameters such as AUC, Cmax, Tmax and t1 /2 of high extraction ratio drug, propranolol, in CCl4-induced liver cirrhosis model of rats. This study describes the bioavaility study of propranolol(5 mg/kg), Shunt Index using thallium-201 per rectum scintigraphy to to measure the amount of portosystemic shunt indirectly and intrahepatic hydroxyproline content performed in the CCl4-induced liver cirrhosis model of rats. (omitted)

  • PDF