• 제목/요약/키워드: shoulder brace

검색결과 9건 처리시간 0.027초

8자형 어깨 보조기와 테이핑 중재가 전방머리자세를 가진 환자의 둥근어깨자세와 등뼈 뒤 굽음 및 가슴우리가동성에 미치는 즉각적인 효과 (Immediate Effects of Figure-8 Shoulder Brace and Taping Intervention on Round Shoulder Posture, Thoracic Kyphosis, and Chest Expansion Mobility in Forward Head Posture Patients)

  • 박재철;정진규;이동규
    • PNF and Movement
    • /
    • 제19권2호
    • /
    • pp.205-213
    • /
    • 2021
  • Purpose: This study investigated the immediate effects of a figure-8 shoulder brace and taping intervention on round shoulder posture, thoracic kyphosis, and chest expansion mobility in forward head posture. Methods: Thirty patients with forward head posture were assigned randomly to the figure-8 shoulder brace group (n = 15) or the taping intervention group (n = 15). Patients were assessed for forward head posture, shoulder posture, thoracic kyphosis, and chest expansion. Results: The figure-8 shoulder brace and taping intervention groups showed a significant difference for forward head posture, shoulder posture, and thoracic kyphosis after the experiment (p < 0.05). There was no significant difference between the groups (p > 0.05). Conclusion: These results suggest that a figure-8 shoulder brace and taping intervention has a positive effect on rounded shoulder posture, thoracic kyphosis, and chest expansion in patients with forward head posture.

어깨 보조기 디자인이 둥근 어깨 자세에 미치는 영향 (Effect of Shoulder Brace Design on Round Shoulder Posture)

  • 강종호;박태성
    • PNF and Movement
    • /
    • 제20권3호
    • /
    • pp.391-397
    • /
    • 2022
  • Purpose: Recently, as a result of the use of smart devices, the incidence of musculoskeletal diseases in areas such as the neck and shoulders has increased. A common effect is rounded shoulder posture, which badly affects the movement and posture of the scapula, causing musculoskeletal disease. Therefore, in this study, we investigated the effects of three shoulder brace products on rounded shoulder posture. Methods: A total of 12 subjects comprising men and women in their 20s with round shoulder posture participated in this study. Three shoulder brace designs were selected, and the height change of the shoulder acromion in the lying state before and after wearing the braces was measured. Effectiveness verification was analyzed using the Mann-Whitney U test. Results: The results confirmed that the different shoulder brace designs had different effects on round shoulder posture. Conclusion: Currently, numerous designs of shoulder braces are being sold, but their effects have not been verified. In the future, more diverse designs of shoulder braces should be studied, and effective shoulder brace designs should be developed and used.

2D 및 3D 패턴 활용 둥근어깨 교정보조기 착용감 비교 (Comfort Evaluation of Posture Braces for Rounded Shoulders Using 2D and 3D Patterns)

  • 오미령;김남임;박진아
    • 패션비즈니스
    • /
    • 제25권3호
    • /
    • pp.71-89
    • /
    • 2021
  • The purpose of this study was to design posture braces for rounded shoulders by examining characteristics of incorrect postures of rounded shoulders. The review of information in literature on rounded shoulder postures, correction exercise methods, and posture correction devices, has prompted this study to determine the design and material of a proper posture brace for rounded shoulders. In order to develop the pattern of a posture brace for rounded shoulders for women, the study carried out a comfort evaluation of the braces based on the 2D patterns through drafting method by utilizing the body measurements and relational formulae associated with the major body measurement such as bust circumference and on the 3D patterns of the brace which were obtained from 3D human model of women in their early 20s in Korea. Differences in angles were noted when 2D and 3D patterns of shoulder posture braces were compared. The side neck point was relocated farther outside in the 3D pattern to allow additional flexibility in the back-neck area, and the shoulder band was lowered by 14.8°, increasing armhole area comfort. The upper hemline of the front panel was found to rotate upward at an angle of 22.0° as the underarm point of the 3D pattern moved upwards than the underarm point of the 2D pattern, which enhanced comfort in the abdomen area. The 3D designs of shoulder posture brace was preferred in this study, as they significantly improved comfort while conducting fit evaluation compared to the 2D patterns of shoulder posture brace.

Kenny-Howard 보조기 착용 후 발생한 전 골간 증후군 - 증례보고 - (Anterior Interosseous Syndrome after Use of a Kenny-Howard Sling for a Acromioclavicular Joint Separation - A Case Report -)

  • 김병석;김근우;남우동;유기형;어수익
    • Clinics in Shoulder and Elbow
    • /
    • 제9권2호
    • /
    • pp.251-254
    • /
    • 2006
  • The anterior interosseous syndrome is an entrapment neuropathy which can be caused by several different etiologies. It is also clinically known that it weakens flexor pollicis longus, flexor digitorum profundus to the index and long fingers without loss of finger sensory. We have experienced anterior interosseous syndrome which found to be rare to ordinary conservative treatment, i.e. application of Kenny-Howard brace, given to a patient with acromioclavicular separation type III. We also review related articles.

양측성 상완이두장건 결손과 견관절 불안정성 - 증례 보고 - (Shoulder instability with congenital absence of bilateral long head of biceps tendon - A Case Report -)

  • 나중호;정회정;김두섭
    • 대한관절경학회지
    • /
    • 제14권3호
    • /
    • pp.188-191
    • /
    • 2010
  • 상완이두장건의 결손은 매우 드문 이상이다. 본원에 내원한 19세 남환은 우측 견관절 아탈구 증상을 주소로 내원하였다. MRI 상 상완골의 얕은 결절사이고랑이 관찰되었으며 상완이두장건의 결손이 관찰되었다. 견관절 내시경술을 시행하였으며 관절와순 파열과 함께 상완이두장건의 결손이 관찰되었다. 5개월 뒤 좌측 견관절에도 우측 견관절과 같은 증상이 발생하였고 MRI 및 견관절 내시경 소견 상 상완이두장건의 결손 소견 및 관절와순 파열 소견이 관찰되었다. 양측 견관절 모두 내시경적 관절와순 봉합술을 시행하였으며 수술 후 위팔 외전 보조기를 이용하여 고정하였다. 상완이두장건의 결손이 견관절의 불안정성을 유발할 수 있을 것이라고 생각한다.

  • PDF

Ulnar collateral ligament repair in professional baseball players

  • Ajith Malige;Carlos Uquillas
    • Clinics in Shoulder and Elbow
    • /
    • 제27권3호
    • /
    • pp.278-285
    • /
    • 2024
  • Background: While initial reports of surgical repair are promising, literature detailing post-repair outcomes is lacking. This study explores the effectiveness of ulnar collateral ligament (UCL) repair in returning professional baseball players to their pre-injury level of play. Professional baseball players undergoing UCL repair will have successful outcomes and high return to sport rates after surgery. Methods: From 2016 to 2021, publicly available databases were utilized to search for professional baseball players who underwent UCL repair. Players were included if they underwent primary UCL repair with an internal brace. Players were excluded if they underwent revision UCL repair, UCL reconstruction, or were amateur baseball players. Results: Of the 11 pitchers that underwent UCL repair, MiLB pitchers returned to sport at an average of 17.5 months. MiLB pitchers had similar ERA, games played, innings pitched, and walks plus hits per inning pitched (WHIP) before and after surgery. Four MLB pitchers (80%) returned to sport at 9.55 months. MLB pitchers had fewer games played and innings pitched but similar ERA and WHIP in after versus before surgery. Pitch velocity and spin rates after surgery varied based on pitch type. The 7 positional players who underwent UCL repair showed no differences in batting or fielding performances before versus after surgery. Conclusions: UCL repair can successfully return both pitchers and positional players at both the MiLB and MLB level back to play at pre-injury levels. Repair can be considered as an option in the right type of injury for players hoping to maximize performance after surgery with minimal recovery time.

The effect of postoperatively applied far-infrared radiation on pain and tendon-to-bone healing after arthroscopic rotator cuff repair: a clinical prospective randomized comparative study

  • Yoon, Ji Young;Park, Joo Hyun;Lee, Kwang Jin;Kim, Hyong Suk;Rhee, Sung-Min;Oh, Joo Han
    • The Korean Journal of Pain
    • /
    • 제33권4호
    • /
    • pp.344-351
    • /
    • 2020
  • Background: The effects of far-infrared radiation (FIR) on the treatment of rotator cuff diseases remains unknown. We evaluated the safety and efficacy of FIR after arthroscopic rotator cuff repair with regard to postoperative pain and healing. Methods: This prospective randomized comparative study included 38 patients who underwent arthroscopic rotator cuff repair due to a medium-sized tear. Patients were randomly divided into the FIR or control group (n = 19 per group). In the FIR group, FIR with an FIR radiator started 1 week postoperatively for 30 minutes per session twice daily. It lasted until abduction brace weaning at 5 weeks postoperatively. We assessed pain using a pain visual analogue scale (pVAS) and measured the range of motion (ROM) of the shoulder at 5 weeks, and 3 and 6 months, postoperatively. The anatomical outcome was evaluated using magnetic resonance imaging at 6 months postoperatively. Results: At 5 weeks postoperatively, the average pVAS score was lower in the FIR group than in the control group (1.5 ± 0.8 vs. 2.7 ± 1.7; P = 0.019). At 3 months postoperatively, the average forward flexion was higher in the FIR group (151.6° ± 15.3° vs. 132.9° ± 27.8°; P = 0.045), but there was no significant difference at 6 months postoperatively. There was no significant difference in healing failure between the groups (P = 0.999). Conclusions: FIR after arthroscopic rotator cuff repair could be an effective and safe procedure to reduce postoperative pain, thereby facilitating rehabilitation and better ROM in the early postoperative period.

Comparison of the effectiveness of extensor muscle strengthening exercise by itself, exercise with polydeoxyribonucleotide injection, and exercise with extracorporeal shockwave therapy in lateral epicondylitis: a randomized controlled trial

  • Shim, Bum Jin;Seo, Eun-Min;Hwang, Jung-Taek;Kim, Do-Young;Yang, Jae-Shin;Seo, Su-Jung;Hong, Myung Sun
    • Clinics in Shoulder and Elbow
    • /
    • 제24권4호
    • /
    • pp.231-238
    • /
    • 2021
  • Background: Extensor muscle strengthening exercises with counterforce braces (EX) is a conventional conservative treatment for lateral epicondylitis (LE) of the elbow. In addition, polydeoxyribonucleotide (PDRN) or extracorporeal shockwave therapy (ESWT) has been recently used for LE. Methods: Sixty-three patients with chronic LE participated in this study and randomly allocated in three groups (G1: EX, G2: EX+PDRN injection, and G3: EX+ESWT). All of the three groups were taught to perform EX at the first out-patient department (OPD) visit. Group 2 was injected with 3 mL PDRN (5.625 mg/3 mL), while group 3 received ESWT at the first OPD visit. Visual analog scale pain score, Mayo elbow performance score (MEPS), and ultrasonographic examination were checked before, 6 weeks, and 12 weeks after the treatments. Results: Overall functional scores and ultrasonographic findings in all three groups improved after treatment. The mean MEPS in group 2 improved more than groups 1 and 3 at 6 weeks (G1, 56.9>62.4; G2, 54.3>65.0; G3, 55.7>62.6), and more than group 1 at 12 weeks (G1, 56.9>67.9; G2, 54.3>73.6). The mean common extensor tendon depth (CETD) on ultrasonography in group 2 increased more than groups 1 and 3 at 6 and 12 weeks (6 weeks: G1, 0.385>0.386; G2, 0.332>0.392; G3, 0.334>0.357; 12 weeks: G1, 0.385>0.409; G2, 0.332>0.438; G3, 0.334>0.405 [cm]). Conclusions: PDRN injections combined with EX exhibited a greater improvement in mean MEPS and mean CETD compared to EX only or EX combined with ESWT for LE within the 12 weeks follow-up.

압박 긴장대 방법을 이용한 구상 돌기 골절의 견고한 고정과 조기 운동을 통한 주관절 기능의 향상 (Improvement of the Elbow Function with Early Mobilization and Rigid Fixation of Coronoid Fracture by Tension Band Technique)

  • 류인혁;서보건;김형진;정재익;김경철
    • Clinics in Shoulder and Elbow
    • /
    • 제12권2호
    • /
    • pp.159-166
    • /
    • 2009
  • 목적: 압박 긴장대 방법을 이용한 작은 구상 돌기 골절의 견고한 고정과 주관절의 조기 운동을 통한 기능의 향상 및 그 결과를 분석하고자 한다. 재료 및 방법: 주관절 내측접근법으로 K-강선과 철선을 이용하여 고정된 8예의 구상돌기 골절을 대상으로 하였다. 분류상 8예 모두 Regan-Morrey type 2였으며 O'Driscoll 분류12)로는 tip형(subtype 2)가 예, anteromedial 형 (subtype 2, 1예 그리고 subtype 3, 2예)3예였다. 동반 손상으로는 측부인대 파열이 6예, 요골두 및 경부골절이 4예였으며 모두 함께 치료하였다. 술 후 5~7일간의 고정 치료 후 경첩 보조기 (hinge brace)을 착용한 상태에서 술후 6주까지 능동적 운동을 허용하였다. 술 후 통증의 여부, 관절 운동 범위, Mayo elbow performance score(MEPS)을 이용한 기능적 평가 방법을 이용하여 치료 결과를 분석하였다. 평균 11 (6~28)개월 추시 하였으며 척골 신경 증상에 대해서도 함께 조사하였다. 결과: 모든 구상돌기 골절은 내고정용 도구의 실패 없이 모두 유합되었다. 평균 2.2 (2~4)개의 K-강선이 사용되었다. 관절운동 범위에 대해 신전은 평균 $3^{\circ}(0^{\circ}\sim25^{\circ})$, 굴곡는 평균 $137^{\circ}(130^{\circ}\sim140^{\circ})$, 회내전은 평균 $69^{\circ}(45^{\circ}\sim90^{\circ})$, 회외전은 $78^{\circ}(45^{\circ}\sim90^{\circ})$이였다. MEPS는 평균 96 (65~100) 이였다. 척골 신경 증상은 terrible triad 1예에서 첫 수술 (index operation)후 요골두를 절제하고 내측 측부 인대의 기능 부전이 있는 1예에서 관찰되었다. 결론: 쉽게 구할 수 있으며 가격이 저렴한 K-강선과 철선을 이용한 압박 긴장대 방법은 충분히 견고하여 조기에 능동적 운동을 허용할 수 있어 주관절의 기능 향상을 가져올 수 있었다. 이 방법은 특히 다발성 소형 구상 돌기 골절의 경우 유용한 하나의 고정 방법으로 생각된다.