• 제목/요약/키워드: shoes insole

검색결과 55건 처리시간 0.017초

런닝화의 미드솔 경도가 하지 근육의 피로와 충격력에 미치는 영향 (The Effect of Midsole Hardness of Running Shoe on Fatigue of Lower Extremity Muscles and Impact Force)

  • Kim, Eonho;Lim, Kyuchan;Cho, Seunghyun;Lee, Kikwang
    • 한국운동역학회지
    • /
    • 제29권3호
    • /
    • pp.167-172
    • /
    • 2019
  • Objective: The aim of this study was to investigate the effect of midsole hardness of running shoe on muscle fatigue and impact force during distance running. Method: Ten healthy college recreational runners who were performing distance running at least three times a week participated in this experiment. They were asked to run for 15 minutes in the treadmill at 10 km/h with running shoes having three different types of midsole hardness (Soft, Medium, Hard). EMG signal and insole pressure were collected during the first and last one minute for each running trials. Data were analyzed using a one-way analysis of variance (ANOVA) with repeated measures. Results: Midsole hardness did not affect the consistency of stride length. For the median frequency of the EMG signal, only VL was affected by midsole hardness; that of medium was greater than other midsoles (p<.05). The loading rate of impact forces increased by midsole hardness (p<.01). Conclusion: Although soft midsole could attenuate impact forces at heel contact, it might have a negative effect on the fatigue of muscle which could decelerate the body after heel contact. Therefore, it is necessary to select the optimum hardness of midsole carefully for both reduction impact forces and muscle fatigue.

스마트 인솔의 족저압 측정 결과에 대한 타당도 및 신뢰도 평가 (Assessment of Validity and Reliability of Plantar Pressure in Smart Insole)

  • 강호원;안예린;김대유;이동오;박길영;이동연
    • 대한족부족관절학회지
    • /
    • 제26권3호
    • /
    • pp.130-135
    • /
    • 2022
  • Purpose: Smart insoles are wearable devices that are inserted into shoes. Smart insoles with built-in pressure and acceleration sensors can measure the plantar pressure, stride length, and walking speed. This study evaluated the validity and reliability of the plantar pressure measurements of smart insoles during walking on flat ground. Materials and Methods: Twenty one subjects were included in this study. After wearing smart insoles, I-SOL® (Gilon, Seongnam, Korea), the subjects walked a 10 m corridor six times at a rate of 100 steps/min, and the middle three steps, free from direction changes, were chosen for data analysis. The same protocol was repeated after wearing Pedar-X (Novel Corporation, Munich, Germany), an insoletype plantar pressure measurement equipment with proven validity. The average maximum pressure (Ppeak, kPa) and the time at which Ppeak appeared (Ptime, %stride) were calculated for each device. The validity of smart insoles was evaluated by using the interclass correlation coefficient (ICC) of Ppeak and Ptime between the two instruments, and Cronbach's alpha was obtained from the Ppeak values to evaluate the reliability. Results: The ICC of Ppeak was 0.651 (good) in the hallux, 0.744 (good) in the medial forefoot, 0.839 (excellent) in the lateral forefoot, and 0.854 (excellent) in the hindfoot. The ICC of Ptime showed 0.868 (excellent) in the hallux, 0.892 (excellent) in the medial forefoot, 0.721 (good) in the lateral forefoot, and 0.832 (excellent) in the hindfoot. All ICC values showed good or excellent results. The Cronbach's alpha of Ppeak measured in the smart insoles was 0.990 in the hallux, 0.961 in the medial forefoot, 0.973 in the lateral forefoot, and 0.995 in the hindfoot; all indicated excellent reliability in all areas. Conclusion: The plantar pressure measurements of smart insoles during walking on a flat ground showed validity compared to Pedar-X, and high reliability after repeated measurements.

유산소 운동능력 향상을 위한 중량물 부가 신발의 기능성 평가 (The Evaluation of an additional Weight Shoe's Function developed for the Improvement of Aerobic Capacity)

  • 곽창수;김희석
    • 한국운동역학회지
    • /
    • 제14권3호
    • /
    • pp.67-82
    • /
    • 2004
  • The purpose of this study was to evaluate the function and the safety of an additional weight shoe developed for the improvement of aerobic capacity, and to improve some problems found by subject's test for an additional weight shoe. The subjects employed for this study were 10 college students. 4 video cameras, AMTI force platform and Pedar insole pressure distribution measurement device were used to analyze foot motions. The results of the study were as follows: 1 The initial achilles tendon angle and initial rearfoot pronation angle of an additional weight shoe during walking were 183.7 deg and 2.33 deg, respectively, and smaller than a barefoot condition. Maximum achilles tendon angle and the angular displacement of achilles tendon angle were 185.35 deg and 4.21 deg respectively, and smaller than barefoot condition. Thus rearfoot stability variables were within the permission value for safety. 2. Maximal anterior posterior ground reaction force of additional weight shoe was appeared to be 1.01-1.2 B.W., and was bigger than a barefoot condition. The time to MAPGRF of an additional weight shoe was longer than a barefoot condition. Maximal vertical ground reaction force of additional weight shoe was appeared to be 2.3-2.7 B.W., and was bigger than a barefoot condition in propulsive force region. But A barefoot condition was bigger in braking force region. The time to MVGRF of an additional weight shoe was longer than a barefoot condition. 3. Regional peak pressure was bigger in medial region than in lateral region in contrast to conventional running shoes. The instant of regional peak pressure was M1-M2-M7-M4-M6-M5 -M3, and differed form conventional running shoes. Regional Impulse was shown to be abnormal patterns. There were no evidences that an additional weight shoe would have function and safety problems through the analysis of rearfoot control and ground reaction force during walking. However, There appeared to have small problem in pressure distribution. It was considered that it would be possible to redesign the inner geometry. This study could not find out safety on human body and exercise effects because of short term research period. Therefore long term study on subject's test would be necessary in the future study.

Activity and Safety Recognition using Smart Work Shoes for Construction Worksite

  • Wang, Changwon;Kim, Young;Lee, Seung Hyun;Sung, Nak-Jun;Min, Se Dong;Choi, Min-Hyung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권2호
    • /
    • pp.654-670
    • /
    • 2020
  • Workers at construction sites are easily exposed to many dangers and accidents involving falls, tripping, and missteps on stairs. However, researches on construction site monitoring system to prevent work-related injuries are still insufficient. The purpose of this study was to develop a wearable textile pressure insole sensor and examine its effectiveness in managing the real-time safety of construction workers. The sensor was designed based on the principles of parallel capacitance measurement using conductive textile and the monitoring system was developed by C# language. Three separate experiments were carried out for performance evaluation of the proposed sensor: (1) varying the distance between two capacitance plates to examine changes in capacitance charges, (2) repeatedly applying 1 N of pressure for 5,000 times to evaluate consistency, and (3) gradually increasing force by 1 N (from 1 N to 46 N) to test the linearity of the sensor value. Five subjects participated in our pilot test, which examined whether ascending and descending the stairs can be distinguished by our sensor and by weka assessment tool using k-NN algorithm. The 10-fold cross-validation method was used for analysis and the results of accuracy in identifying stair ascending and descending were 87.2% and 90.9%, respectively. By applying our sensor, the type of activity, weight-shifting patterns for balance control, and plantar pressure distribution for postural changes of the construction workers can be detected. The results of this study can be the basis for future sensor-based monitoring device development studies and fall prediction researches for construction workers.

등산화의 종류와 보행동작에 따른 지면반력 및 족저압력 분석 (Analyses of GRF & Insole Foot-Pressure Distribution: Gait Patterns and Types of Trekking Boots)

  • 박승범;이중숙
    • 한국운동역학회지
    • /
    • 제17권4호
    • /
    • pp.191-200
    • /
    • 2007
  • The purpose of this study was to analyze the foot-pressure distribution of trekking boots for assessing their functionality. Subjects participated in this study included 10 university male students who had no injury experience in lower limbs and a normal gait pattern. The size of all subjects was 270mm. Five models of trekking boots, most popular in Korea (A, B, C, D & E company), were selected for the test. Using the PEDAR-X system and PEDAR-X insoles, 5 different walking stages were analyzed for the foot-pressure distribution: (a) straight gait; (b) $45^{\circ}$ turn gait; (c) $25^{\circ}$ uphill gait; and (d) $25^{\circ}$ downhill gait. Results of the foot-pressure distribution and functionality on each stage were as follow; 1. Straight gait - In case of Max ground reaction force, mean plantar pressure and Max plantar pressure, there was not a distinct tendency; however, products manufactured by E and A company showed relatively lower pressure distribution. 2. $45^{\circ}$ turn gait - In Max ground reaction force, mean plantar pressure and Max plantar pressure, there wasn't a distinct tendency; however, products manufactured by E and A company showed relatively lower pressure distribution. Results also revealed that the products manufactured by E and A company were superior to those by other companies in terms of functionality. 3. $25^{\circ}$ uphill gait - In Max ground reaction force, mean plantar pressure and Max plantar pressure, there wasn't a distinct tendency; however, products manufactured by E and C company showed relatively lower pressure distribution. Results also revealed that the products manufactured by E and C company were superior to those by other companies in terms of functionality. 4. $25^{\circ}$ downhill gait - In Max ground reaction force, Mean plantar pressure and Max plantar pressure, there wasn't a distinct tendency; however, products manufactured by E company showed relatively lower pressure distribution. Results also revealed that the products manufactured by E company were superior to those by other companies in terms of functionality. Overall, five pairs of trekking shoes selected in this study showed the excellent performance in several conditions. The findings above may provide us with the important criteria for choosing trekking boots.