High Current MIG Welding of Al 5083 Alloy under Ar/He Mixed Gas Shielding (Ar/He 보호가스분위기에서 Al 5083 합금의 대전류 MIG 용접특성)

  • Choi, Young-Bae;Hwang, In-Sung;Kang, Mun-Jin;Kim, Dong-Cheol
    • Journal of Welding and Joining
    • /
    • v.32 no.1
    • /
    • pp.87-92
    • /
    • 2014
  • Recently, use of thick Al 5083 plate has increased in production of LNG storage tank. In general, multi-pass welding has been used to achieve sufficient penetration in thick plate welding. High current welding which enables high deposition and deep penetration is preferred in thick plate welding because the increase of number of pass increases manufacturing cost and formation of weld defect. In this study, welding characteristics according to various Ar/He shielding gas composition was investigated in high current MIG welding. The bead-on-plate welding and V groove welding were conducted on Al 5083 alloy with a thickness of .25 mm. The effect of shielding gas composition on bead shape was evaluated and proper shielding gas composition was proposed. Also arc stability was examined under selected shielding gas composition. One side-one pass welding experiments were conducted for V groove specimen with a thickness of 25 mm. Mechanical properties and hardness profiles were measured for the V groove specimens.

A Study on the Characteristics of RTA Furniture and Development of Seminar Table (RTA가구의 특성과 세미나 테이블 개발에 관한 연구)

  • Lee, Nak Hyun;Kim, Mi Sook
    • Journal of the Korea Furniture Society
    • /
    • v.28 no.4
    • /
    • pp.259-267
    • /
    • 2017
  • Furniture should change according to space. Therefore, it is important that the flexibility of the furniture, the functional efficiency, the economical efficiency and the convenience of the furniture of today. These characteristics are also important for seminar tables that are used temporarily by a large number of people. The seminar furniture currently in use has no shielding plate, there are two forms of table and shielding plate folding table. Therefore, in this research, furniture design and product development that can complement the shortcomings of the seminar furniture currently in use were done. Analysis of problems through overseas investigation and domestic market research, design planning and design, and prototyping. We have sought to optimize the volume by applying the characteristics of RTA furniture to develop a lightweight, lightweight, lightweight, easy to install and easy to use shielding plate, and open and closed system. Basically developed two types of shielding board seminar table basic shape and Roll Screen type, we expanded the scope of application such as each color and pattern. In order to reduce the weight, we replaced the parts such as anchor bolts and hinges and the shielding plate with Roll Screen and pursued volume optimization. As a result of this research, it is expected that the system of mechanisms such as packaging standardization and damage prevention for weight reduction and volume optimization will contribute to building competitiveness by domestic office prefabricated furniture industry's original technology.

A Study of Shielding Plate Development for Backlight Control : With a Main Focus on 50W Misaligned LED Luminaires (후사광 제어를 위한 차광판 개발에 관한 연구 : 50W 급 비정렬 LED 조명기구를 중심으로)

  • Park, Tae-Yeon;Kim, Jung-Seok;Kim, Hway-Suh;Oh, Min-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.1-8
    • /
    • 2014
  • Recently, damages resulting from light trespass that affects the human body (sleep) as one of light pollution control elements of outdoor Luminaires equipment are leading to continuous civil complaints and disputes and this is gradually expanding into a social problem. Accordingly, this study considers the need to develop a shielding plate in consideration of light distribution performance as an efficient measure to cope with damages from light trespass. Therefore, this study developed a shielding plate for LED Luminaires with a fine view that maximally inhibited light toward the backlight area compared to existing shielding plates and verified its performance.

Reduction Characteristics of Electromagnetic Penetration through a Slit in a Conducting Screen by a Loaded Triangle Plate (삼각형 도체판 장하에 의한 무한 도체 평판 슬릿의 침투 전자파 저감 특성)

  • Cho, Byung-Ho;Lee, Seung-Ik;Kim, Hyo-Kyun;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.7
    • /
    • pp.767-773
    • /
    • 2014
  • This paper presents the reduction characteristics of electromagnetic penetration through a slit in conducting screen by loaded plate. The FDTD method is used in theoretical analysis. And the characteristics of penetrated electric fields are calculated in terms of length, width, shape, position, and height of the loaded plate to find out how the geometry of plate influences the reduction characteristics of the electromagnetic penetration and shielding effectiveness. The results show that the characteristics of penetrated electric field and shielding effectiveness depend on the geometry of loaded plate. In particular, the optimal geometry of loaded plate which minimize penetrated electric field are verified.

Preliminary Study for Development of Low Dose Radiation Shielding Material Using Liquid Silicon and Metalic Compound (액상 실리콘과 금속화합물을 융합한 저선량 방사선 차폐 소재 개발을 위한 사전연구)

  • Jang, Seo Goo;Han, Su Chul;Kang, Sung Jin;Lim, sung wook;Lee, Sung Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.461-468
    • /
    • 2017
  • This study measured and compared the protective clothing using Pb used for shielding in a diagnostic X-ray energy range, and the shielding rates of X-ray fusion shielding materials using Si and $TiO_2$. For the experiment, a pad type shielding with a thickness of 1 mm was prepared by mixing $Si-TiO_2$, and the X-ray shielding rate was compared with 0.5 mmPb plate of The shielding rate of shielding of 0.5 mmPb plate 95.92%, 85.26 % based on the case of no shielding under each 60 kVp, 100 kVp tube voltage condition. When the shielding of $Si-TiO_2$ pad was applied, the shielding rate equal to or greater than 0.5 mmPb plate was obtained at a thickness of 11 mm or more, and the shielding rate of 100% or more was confirmed at a thickness of 13 mm in 60 kVp condition. When the shielding of $Si-TiO_2$ pad was applied, the shielding rate equal to or greater than 0.5 mmPb plate was obtained at a thickness of 17 mm or more, and a shielding rate of 0.5 mmPb plate was observed at a thickness of 23 mm in 100 kVp condition. Through the results of this study, We could confirm the possibility of manufacturing radiation protective materials that does not contain lead hazard using various metalic compound and liquid Si. This study shows that possibility of liquid Si and other metalic compound can harmonize easily. Beside, It is flexible and strong to physical stress than Pb obtained radiation protective closthes. But additional studies are needed to increase the shielding rate and reduce the weight.

Optimum Design of a Shield Plate to minimize Extremely-Law-Frequency Magnetic Fields produced by Bus Bars (분전반 모선에 의해 발생되는 극저주파 자기장 저감을 위한 차폐판 최적 설계)

  • Jeung, Gi-Woo;Choi, Nak-Sun;Kim, Dong-Hun;Jang, Nak-Won;Lee, Dong-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • This paper deals with the optimal design of a shield plate in order to minimize Extremely-Low-Frequency(ELF) magnetic fields generated from three-phase bus bars. Combining an evolutionary strategy with a 3D finite element analysis tool, the main dimensions of the shield plate are sought out. The optimization procedure consists of two separated design stages to take into account all foreseen structures of the plate. In the first stage, the basic dimensions of the plate are optimized including the distance between the plate and the bus bars. Then the usefulness of the additional structures such as a slit and fillet is investigated in the second stage. Finally the optimum design of the shield plate is suggested from the viewpoint of the shielding effectiveness and manufacturing cost.

A Study on the Plug Weldability of 304 Stainless Steel (304 스테인리스강의 Plug 용접성에 관한 연구)

  • 황종근;장경복;강성수
    • Journal of Welding and Joining
    • /
    • v.16 no.1
    • /
    • pp.106-113
    • /
    • 1998
  • In this study, the plug weldability of STS 304 was investigated. The parameters which influence plug weldability were pushing pressure of the plates, position of welding wire and composition of shielding gases. Among these factors, the composition of shielding gases and hole diameter of the upper plate were found to be the major factors influencing weld quality. To evaluate weldability, tensile shear strength of the plug welded specimen was measured and compared with tensile strength of butt welded specimen. Hardness was measured for both plug weld and butt weld. The microstructure of the weld metal and HAZ were also characterized.

  • PDF

Evaluation of the Usefulness of Tungsten Nanoparticles as an Alternative to Lead Shielding Materials in Electron Beam Therapy (전자선 치료시 납 차폐체 대체물질로서의 텅스텐 나노입자의 유용성 평가)

  • Kim, Ji-Hyang;Kim, Na-Kyoung;Lee, Gyu-Yeong;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.949-956
    • /
    • 2021
  • The purpose of this paper is to evaluate whether tungsten nanoparticles have a shielding effect on scattered light generated at high doses as an alternative material to lead used to shield scattered light in electron beam therapy. A plate was manufactured to set the position of the dosimeter and the size of the radiation field to be constant. The glass dosimeter was placed at 12 points, which were 1, 2, and 4 cm apart from the center of the field of 10 × 10 cm2 in the cross direction. A total of 12 types of tungsten nanoparticle shields were developed with a thickness of 0.75 mm to 4.00 mm and a size of 10 × 10 cm2 using 0.4, 0.75, and 1 mm materials. Using a linear accelerator, measurements were made four times at 6 MeV and four times at 12 MeV, and the dose intensity was investigated at 100 MU. The 4 mm shielding plate showed the highest shielding effect at 1 cm from the irradiation field. The 1 mm shielding plate at 2 cm from the irradiation field had the lowest shielding effect. As the thickness of the tungsten shielding plate increased, the electron beam's shielding effect increased sharply. It was confirmed that tungsten nanoparticles can reduce the amount of scattered light generated by electron beam therapy. Therefore, this study will provide basic data when follow-up studies are conducted on the shielding ability of tungsten nanoparticles.

Design and stress analysis of femur bone implant with composite plates

  • Ramakrishna, S.;Pavani, B.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.5 no.1
    • /
    • pp.37-50
    • /
    • 2020
  • Development of lightweight implant plates are important to reduce the stress shielding effect for a prosthesis of femur bone fractures. Stainless steel (SS-316L) is a widely used material for making implants. Stress shielding effect and other issues arise due to the difference in mechanical properties of stainless steel when compared with bone. To overcome these issues, composite materials seem to be a better alternative solution. The comparison is made between two biocompatible composite materials, namely Ti-hydroxyapatite and Ti-polypropylene. "Titanium (Ti)" is fiber material while "hydroxyapatite" and "polypropylene" are matrix materials. These two composites have Young's modulus closer to the bone than stainless steel. Besides the variety of bones, present paper constrained to femur bone analysis only. Being heaviest and longest, the femur is the most likely to fail among all bone failures in human. Modelling of the femur bone, screws, implant and assembly was carried out using CATIA and static analysis was carried out using ANSYS. The femur bone assembly was analyzed for forces during daily activities. Ti-hydroxyapatite and Ti-polypropylene composite implants induced more stress in composite implant plate, results less stress induced in bone leading to a reduction in shielding effect than stainless steel implant plate thus ensuring safety and quick healing for the patient.

Control of Conductive Plate Through Varying the Open Area Size of the Partially, Magnetically Isolated Electrodyamic Wheel (부분 차폐된 동전기 휠의 개방 영역 크기 조절을 통한 전도성 평판의 제어)

  • Jung, Kwang-Suk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.3
    • /
    • pp.230-236
    • /
    • 2012
  • Shielding the air-gap magnetic field of the electrodynamic wheel below a conductive plate and opening the shielding plate partially, a thrust force and a normal force generate on the conductive plate at the open area. But, as only the variable controlling both forces is a rotating speed of the electrodynamic wheel, it is very difficult to control the forces independently by the speed. So, we discuss a novel method controlling the forces effectively through manipulating a size of the open area. The independent control is made possible by virtue of the feature that the relative ratio between both forces is irrelevant to an air-gap length and determined uniquely for a specific rotating speed of the wheel. Therefore, the rotating speed and the size of open area become new control variables. The feasibility of the method is verified experimentally. Specially, the controllable magnetic forces are used in a noncontact conveyance of the conductive plate.