• Title/Summary/Keyword: shield analysis

Search Result 451, Processing Time 0.027 seconds

Establishment of Maintenance and Monitoring Standards for Shield and TBM Tunnels (Shield 및 TBM 터널의 유지관리계측 관리기준 설정에 관한 연구)

  • Jong-Tae Woo
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.1-12
    • /
    • 2024
  • Purpose: The objective of this study was to improve the tunnel maintenance and monitoring technology by establishing the maintenance, management, and monitoring standards for shield and TBM tunnels, which had been applied more in recent years. Method: This study comprehensively analyzed and compared the data and model simulations of Seoul Subway Lines 7 and 9 and Bundang Line, shield and TBM tunnels in South Korea, tunnels in France and Japan, and Channel Tunnel in the UK. Result: This study set maintenance and monitoring standards when there was no design estimate based on numerical analyses such as section design and section analysis regarding the maintenance and monitoring section of shield and TBM tunnels. Conclusion: It is necessary to determine safety by comprehensively considering not only each monitoring item but also the changing trend and correlation of all items and compensation of the tunnel.

Development of Thruster Heat Shield for Satellite (인공위성 추력기 열차폐막 개발)

  • Lee Hae-Heon;Jang Ki-Won;Lee Jae-Won;Yu Myoung-Jong;Lee Kyun-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.27-30
    • /
    • 2005
  • Hanwha Corporation succeeded in domestic development of thruster heat shield for KOMPSAT-2 propulsion subsystem partly. Thruster heat shield, one of the main components of DTM, is designed to prevent the critical radiative heat exchange between thruster and satellite during firing. To overcome the manufacturing difficulties, an electro-forming process is preferred to classical welding process. In this case, an inner diameter of a new shield will be decreased a little due to the change of manufacturing process. The interference problem between thruster nozzle and heat shield was investigated through structural analysis by KARI. Hanwha manufactured heat shield based on the analysis results. In this paper, full development process is described for design, analysis, manufacturing of heat shield.

  • PDF

Shielding design and analyses of the cold neutron guide hall for the KIPT neutron source facility

  • Zhong, Zhaopeng;Gohar, Yousry
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.989-995
    • /
    • 2018
  • Argonne National Laboratory of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have cooperated on the development, design, and construction of a neutron source facility. The facility was constructed at Kharkov, Ukraine, and its commissioning process is underway. The facility will be used for researches, producing medical isotopes, and training young nuclear specialists. The neutron source facility is designed with a provision to include a cryogenically cooled moderator system-a cold neutron source (CNS). This CNS provides low-energy neutrons, which will be used in the scattering experiment and material structures analysis. Cold neutron guides, coated with reflective material for the low-energy neutrons, will be used to transport the cold neutrons to the experimental site. The cold neutron guides would keep the cold neutrons within certain energy and angular space concentrated inside, while most of the gamma rays and high-energy neutrons are not affected by the cold neutron guides. For the KIPT design, the cold neutron guides need to extend several meters outside the main shield of the facility, and curved guides will also be used to remove the gamma and high-energy neutron. The neutron guides should be installed inside a shield structure to ensure an acceptable biological dose in the facility hall. Heavy concrete is the selected shielding material because of its acceptable performance and cost. Shield design analysis was carried out for the CNS guide hall. MCNPX was used as the major computation tool for the design analysis, with neutron and gamma dose calculated separately. Weight windows variance reduction technique was also used in the shield design. The goal of the shield design is to keep the total radiation dose below the $5.0{\mu}Sv/hr$ guideline outside the shield boundary. After a series of iterative MCNPX calculations, the shield configuration and parameters of CNS guide hall were determined and presented in this article.

Analysis of surface flashover along shield gap inner vacuum interrupter (진공 인터럽터 내부 쉴드간 gap에 따른 연면방전 특성파악)

  • Yoon, Jae-Hun;Lee, Seung-Su;Lim, Kee-Jo;Kim, Sung-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.103-104
    • /
    • 2008
  • this paper describes the electric field distribution analysis along a shield gap inner vacuum interrupter(VI). The equipotential line and electric field and field vector in a VI are analysed by a finite element method and experiment at shield gap. in result, The equipotential line and electric field distribution was affected to VI shield gap. The reason is as it gets distortion of equipotential line done. finally, this paper recognized whether or not affected, and proposed gap with the most suitable shield length and an external insulation.

  • PDF

Two-Dimensional Elasto-Viscoplastic Finite Element Analysis Considering Shield Tunneling Construction Stages (실드터널 시공단계를 고려한 2차원 탄.점소성 유한요소해석)

  • 진치섭;노경배;한상중
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.10a
    • /
    • pp.89-94
    • /
    • 1996
  • The use of shield is increasing day by day, because it's method is advantageous tunneling method to soft and collapsible ground. In case of analyzing shield tunnel by FEM, short term behavior of ground by initial heaving and tail void closure and long terms of it because of consolidation by changes of pore pressures in clay must be considered. In this paper, the shield tunneling construction stages was analyzed from 2 dimensional elasto - viscoplastic finite element program used Mohr - Coulomb yield criterion but not considered the changes of pore pressures. The object of investigation was N - 2 Tunnel. Since the good results of analysis compared to the measured behavior of ground for heaving, tail void closure and liner installation, this results can be applied to design and construction of shield tunneling for the subways, sewage lines etc.

  • PDF

Computational analysis of sandwich shield with free boundary inserted fabric at hypervelocity impact (비구속 삽입된 직물 섬유를 이용한 샌드위치 쉴드의 초고속 충격 해석)

  • Moon, Jin-Bum;Park, Yu-Rim;Son, Gil-Sang;Kim, Chun-Gon
    • Composites Research
    • /
    • v.24 no.3
    • /
    • pp.31-38
    • /
    • 2011
  • In this paper, a novel hybrid composite shield to protect space structures from hypervelocity impact of micrometeoroid and space debris is proposed. The finite element model of the proposed shield was constructed and finite element analysis was conducted to approximate the energy absorption rate. Before the final model analysis, analysis of each component including the aluminum plate, PMMA plate, and intermediate layer of fabric was performed, verifying the finite element model of each component. The material properties used in the analyses were predicted material property values for high strain rates. The analysis results showed that, other than the fabric, the energy absorption rate of each component was in agreement. Afterwards, the finite element model of the hybrid composite shield was constructed, where it was analyzed for the restrained and unrestrained fabric boundary condition cases. Through the finite element analysis, the fiber pullout mechanism was realized for the hybrid shield with free boundary inserted fabric, and it was observed that this mechanism led to energy absorption increase.

Analysis of Current Distribution of HTSC Power Cable Considering Shield Layer (차폐층을 고려한 고온초전도 전력 케이블의 전류분류 해석)

  • Lee, Jong-Hwa;Lim, Sung-Hun;Ko, Seok-Cheol;Park, Chung-Ryul;Han, Byoung-Sung;Hwang, Si-Dole
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.12-14
    • /
    • 2004
  • Superconducting transmission power cable is one of interesting parts in power application using high temperature superconducting wire. One of import ant parameters in high-temperature superconduting (HTSC) cable design is transport current distribution because it is related with current transmission capacity and AC loss. In this paper, the transport current distribution at conducting layers was investigated through the analysis of the equivalent circuit for HTSC power cable with shield layer and compared with the case of without shield layer. The transport current distribution due to of the contact resistance and the pitch was improved in the case of HTSC power cable with shield layer from the analysis.

  • PDF

A Study on ground behavior of shield TBM lunching area during xcavation (Shield TBM 발진부 굴착에 따른 지반거동에 관한 연구)

  • O, Tae-Sang;Kim, Bae-Sik;Sin, Han-Cheol;Kim, Sang-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.353-364
    • /
    • 2011
  • This paper presents the ground behaviour of shield TBM lunching area during excavation. In order to perform this study, a scaled model test was carried out in the 1/45 scale for a field tunnel in practice where the tunnel had about 7.8 m diameter at Seoul Metro Line 9 construction site. The test to simulate earth pressure balance (EPB) shield TBM tunnelling at the lunching area was conducted with the developed small scaled shield TBM machine. Measurements were performed during simulation of excavation for total jacking thrust force, ground displacements and pressures. Based on the analysis of simulation results, the stability of ground was verified and evaluated. In particular, the suitable reinforcement range and methods are also suggested. In addition, these results are useful for engineers and technicians to select suitable and serviceable machine operation parameters and reduce environmental influence at all stages of tunnel construction.

  • PDF

A Study on the Thermal and Flow Characteristics of Wind and Radiant Heat Shield for Offshore by using Mesh Screen (메쉬 스크린을 적용한 해양구조물용 방풍 및 복사열 차단막 열유동특성에 관한 연구)

  • Yi, Chung-Seob;Chin, Do-Hun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.166-173
    • /
    • 2012
  • This study is about comparison of thermal and flow characteristics on the wind & radiant heat shield with STS mesh type screen for offshore. Numerical analysis was conducted to find transmission coefficient in the mesh and then analyse the flow characteristics about wind & radiant heat shield. The experiment method of solar radiation has been used as thermal radiation source to get the performance of radiant heat shield measurement. The sensor radiation device has been used to measure the reduction of solar radiation with various size of cells and at a distance of 0.5m and 1m from the cold face of the wind & radiant heat shield.

A Study on Shield Effect of Shield Case using SiFe Sheet (규소강판을 이용한 실드케이스의 차폐효과)

  • Shin, Dong-Gyu;Kim, Young-Hak
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.48-53
    • /
    • 2014
  • The shield effect of 4 layered shield case was investigated in this paper. The material of the case was non-oriented SiFe sheet with a thickness of 0.5mm. The size of the case was 100mm wide, 100mm high and 300mm long. Relative permeability of SiFe sheet was needed to calculate shield effect. It was obtained from the measurement by a ferrite yoke and from the calculation by eddy current FEM analysis. Three configurations were used to connect both ends of SiFe sheet. First one is a connection by double-welded butt. Second one is to put the sheet the same material above the confronted both ends of the sheet to avoid a leakage magnetic flux. The last one is ideally without any connection. The shield effect of the second one agreed well with the last one and showed the shield effect of -40dB.