• Title/Summary/Keyword: sheet molding compound panel

Search Result 4, Processing Time 0.019 seconds

Automotive Polymer Composite Materials -Sheet Molding Compound- (자동차용 열경화성 고분자복합재료 -SMC를 중심으로-)

  • 조봉규
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1996.06a
    • /
    • pp.63-73
    • /
    • 1996
  • CAFE(기업평균연비) 규제의 적극적 대응책의 하나로 차체 경량화가 주목받고 있다. 이를 위해 사용되는 고분자 복합소재 중 특히 Exterior Body Panel에 많이 채택되고 있는 SMC(Sheet Molding Compound)에 대해 제조방법, 성형공정, 기술적 과제, 재활용, 적용 예 등을 살펴보았다. 1973년 GM의 Corvette로부터 본격적으로 사용되기 시작한 SMC는 미국, 유럽을 중심으로 사용량이 계속 증가되고 있으며, 자동화가 용이하고 성형Cycle이 짧아 타 열경화성 고분자복합재료 성형방법에 비해 대량생산에 유리하며, 도장 특성이 우수하며 자 동차 부품용으로 가장 보편적인 방식이다.

Applicability on Water Treatment Structure of Anti-corrosive Sheet Molding Compound Panel (고분자수지계 패널형 방수방식재의 수처리구조물 적용성에 관한 실험적연구)

  • Seo, Hyun Jae;Park, Jin Sang;Bae, Kee Sun;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.161-163
    • /
    • 2011
  • Due to various kind of waterproof materials and methods, which is difficult to select the most appropriate to waterworks. The materials used to prevent the deterioration of the service life is short, because of the chemical erosion. So, in the 2010 Office of Waterworks Seoul Metropolitan Government has set new standards. Recently, SMC panel is a trend that is being applied to water treatment facilities. However, SMC panel has not yet implemented a performance evaluation. Therefore, this study to confirm that satisfaction for the Office of Waterworks Seoul Metropolitan Government of the performance requirements, when the applied the SMC panel to water treatment structure.

  • PDF

An Evaluation of the Fatigue Properties for External Panel Using Low Density SMC (저비중 SMC 외장패널의 피로특성 평가)

  • Kim, Eun-Sung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.830-835
    • /
    • 2012
  • A research for application of LDSMC(Low Density Sheet Molding Compound) composite is in progress for lightening the weight. This paper has performed fatigue test and simulation of external panel for Korean commercial vehicle. Before the fatigue test, static test was carried out. From the test, the structural safety was investigated using Goodman diagram. After the static test performance, the fatigue test was conducted at a range of load frequency 5Hz, a stress ratio(R) of 0.05 and an endurance limit of $10^6$ to obtain the S-N curve. The S-N curve is applied to the fatigue analysis of the external panel assembly. The result of FEM analysis was in accord with the experimental result within 83% confidence. It showed that the process to set up the safety range of allowable error is required in process of the design and simulation verification.

Seismic Performance Evaluation of Externally Reinforced Panel Water Tank Using Shaking Table Tests (진동대 실험을 통한 외부보강형 판넬조립식 물탱크의 내진성능평가)

  • Park, Se-Jun;Won, Seong-Hwan;Choi, Moon-Seock;Kim, Sang-Hyo;Cheung, Jin-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.151-157
    • /
    • 2013
  • In this study, an externally reinforced structural system for SMC(Sheet Molding Compound) panel water tank, designed according to the Japanese design code, is experimented to evaluate its seismic performance. The test tank is 3m long, 2m wide and 3m high, considering the capacity and size of the shaking table. The measured hydrodynamic pressures are found to be approximately 70% of the Japanese design code values. It may be partially due to the convex shape effect of the unit panels. The analytical results of externally reinforced system based on the measured dynamic water pressures are found in good agreement with the test results. If the design hydrodynamic pressures are estimated properly, the proposed analytical model for the externally reinforced water tank becomes a useful design tool and the Japanese design code is found to provide a safe design for the external frames of SMC panel water tank.