• Title/Summary/Keyword: shear slip

Search Result 484, Processing Time 0.025 seconds

Estimation on Clamping Force of High Strength Bolts Considering Temperature Variable of Both Site conditions and Indoor Environments (실내환경과 건설현장 온도변수를 고려한 고력볼트 체결력 예측)

  • Nah, Hwan-Seon;Lee, Hyeon-Ju
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.3
    • /
    • pp.32-40
    • /
    • 2015
  • The torque shear high strength bolt is clamped normally at the break of pin-tail specified. However, the clamping forces on slip critical connections do not often meet the required tension, as it considerably fluctuates due to torque coefficient dependent on lubricant affected temperature. In this study, the clamping tests of torque shear bolts were conducted independently at indoor conditions and at construction site conditions. During last six years, temperature of candidated site conditions was recorded from $-11^{\circ}C$ to $34^{\circ}C$. The indoor temperature condition was ranged from $-10^{\circ}C$ to $50^{\circ}C$ at each $10^{\circ}C$ interval. As for site conditions, the clamping force was reached in the range from 159 to 210 kN and the torque value was from 405 to $556 N{\cdot}m$. The range of torque coefficient at indoor conditions was analyzed from 0.126 to 0.158 while tensions were indicated from 179 to 192 kN. The torque coefficient at site conditions was ranged from 0.118 to 0.152. Based on this test, the variable trends of torque coefficient, tension subjected temperature can be taken by statistic regressive analysis. The variable of torque coefficient under the indoor conditions is $0.13%/^{\circ}C$ while it reaches $2.73%/^{\circ}C$ at actual site conditions. When the indoor trends and site conditions is combined, the modified variable of torque coefficient can be expected as $0.2%/^{\circ}C$. and the modified variable of tension can be determined as $0.18%/^{\circ}C$.

Study of Inhibition Characteristics of Slurry Additives in Copper CMP using Force Spectroscopy

  • Lee, Hyo-Sang;Philipossian Ara;Babu Suryadevara V.;Patri Udaya B.;Hong, Young-Ki;Economikos Laertis;Goldstein Michael
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.5-10
    • /
    • 2007
  • Using a reference slurry, ammonium dodecyl sulfate (ADS), an anionic and environmentally friendly surfactant, was investigated as an alternative to BTA for its inhibition and lubrication characteristics. Results demonstrated that the inhibition efficiency of ADS was superior to that of BTA. Coefficient of friction (COF) was the lowest when the slurry contained ADS. This suggested that adsorbed ADS on the surface provided lubricating action thereby reducing the wear between the contacting surfaces. Temperature results were consistent with the COF and removal rate data. ADS showed the lowest temperature rise again confirming the softening effect of the adsorbed surfactant layer and less energy dissipation due to friction. Spectral analysis of shear force showed that increasing the pad-wafer sliding velocity at constant wafer pressure shifted the high frequency spectral peaks to lower frequencies while increasing the variance of the frictional force. Addition of ADS reduced the fluctuating component of the shear force and the extent of the pre-existing stick-slip phenomena caused by the kinematics of the process and collision event between pad asperities with the wafer. By contrast, in the case of BTA, there were no such observed benefits but instead undesirable effects were seen at some polishing conditions. This work underscored the importance of real-time force spectroscopy in elucidating the adsorption, lubrication and inhibition of additives in slurries in CMP.

Fixation Method of Prestressed Fiber Optic Sensor (광섬유센서의 프리스트레인 부가 고정방식)

  • Kim, Ki-Soo
    • Composites Research
    • /
    • v.25 no.6
    • /
    • pp.211-216
    • /
    • 2012
  • FBG sensor peaks could be split due to polarization by shear strain, when the fiber optic sensors embedded or attached to the structure. For the fiber optic sensor packages, sensor grating has to be protected from shear strains. Also, pretension has to be applied to the sensor because compressive strain must be measured. Without pretension of sensor, the sensor does not show any change of signal until it is stretched. In order to mesure compressive and tensile strains, two fixing point and prestressed sensor need. In the fixing point, just holding the optical fiber cause slip between core and cladding in the fiber. A Fixation method of prestressed FBG sensors fixed with partially stripped fibers was developed. The sensor package has the prestress controllable fixtures at the fixing points. Prestress to the sensor imposed by controlling the two fixed points with bolts and nuts make it easy to measure compressive strain as well as tensile strain. The fiber optic sensor packages applied to the actual structure and the structural monitoring system using the package can be applied to safety through surveillance.

Experimental evaluation of external beam-column joints reinforced by deformed and plain bar

  • Adibi, Mahdi;Shafaei, Jalil;Aliakbari, Fatemeh
    • Earthquakes and Structures
    • /
    • v.18 no.1
    • /
    • pp.113-127
    • /
    • 2020
  • In this study, the behavior of external beam-column joints reinforced by plain and deformed bars with non-seismic reinforcement details is investigated and compared. The beam-column joints represented in this study include a benchmark specimen by seismic details in accordance with ACI 318M-11 requirements and four other deficient specimens. The main defects of the non-seismic beam-column joints included use of plain bar, absence of transverse steel hoops, and the anchorage condition of longitudinal reinforcements. The experimental results indicate that using of plain bars in non-seismic beam-column joints has significantly affected the failure modes. The main failure mode of the non-seismic beam-column joints reinforced by deformed bars was the accumulation of shear cracks in the joint region, while the failure mode of the non-seismic beam-column joints reinforced by plain bars was deep cracks at the joint face and intersection of beam and column and there was only miner diagonal shear cracking at the joint region. In the other way, use of plain bars for reinforcing concrete can cause the behavior of the substructure to be controlled by slip of the beam longitudinal bars. The experimental results show that the ductility of non-seismic beam-column joints reinforced by plain bars has not decreased compared to the beam-column joints reinforced by deformed bars due to lack of mechanical interlock between plain bars and concrete. Also it can be seen a little increase in ductility of substructure due to existence of hooks at the end of the development length of the bars.

Investigation of Strain Behaviour around the Tip of Model Pile - Comparison between Laboratory Model Test and Numerical Analysis - (모형말뚝 선단부 주변의 변형률 거동 분석 - 실내모형실험과 수치해석 비교 -)

  • Lee, Yong Joo;Lee, Jung-Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4C
    • /
    • pp.159-167
    • /
    • 2012
  • In this study, laboratory model pile-load test and finite element analysis were carried out to compare and analyze the strain behaviour around the model pile tip. In order to simulate the pile load, both the LCM(load control method)and DCM(displacement control method) were introduced to determine which one is appropriate for the FE simulation. In contrast to the previous simulation method, two interface elements around the model pile were used to consider the slip effect in the finite element analysis and its results were compared to the model test. Through this study it was found that the degree of non-associated flow was a dominant factor in terms of numerical solution convergence. In addition, an improved FE mesh was required to obtain the symmetric distribution of the maximum shear strain contour.

Test and simulation of circular steel tube confined concrete (STCC) columns made of plain UHPC

  • Le, Phong T.;Le, An H.;Binglin, Lai
    • Structural Engineering and Mechanics
    • /
    • v.75 no.6
    • /
    • pp.643-657
    • /
    • 2020
  • This study presents experimental and numerical investigations on circular steel tube confined ultra high performance concrete (UHPC) columns under axial compression. The plain UHPC without fibers was designed to achieve a compressive strength ranged between 150 MPa and 200 MPa. Test results revealed that loading on only the UHPC core can generate a significant confinement effect for the UHPC core, thus leading to an increase in both strength and ductility of columns, and restricting the inherent brittleness of unconfined UHPC. All tested columns failed by shear plane failure of the UHPC core, this causes a softening stage in the axial load versus axial strain curves. In addition, an increase in the steel tube thickness or the confinement index was found to increase the strength and ductility enhancement and to reduce the magnitude of the loss of load capacity. Besides, steel tube with higher yield strength can improve the post-peak behavior. Based on the test results, the load contribution of the steel tube and the concrete core to the total load was examined. It was found that no significant confinement effect can be developed before the peak load, while the ductility of post-peak stage is mainly affected by the degree of the confinement effect. A finite element model (FEM) was also constructed in ABAQUS software to validate the test results. The effect of bond strength between the steel tube and the UHPC core was also investigated through the change of friction coefficient in FEM. Furthermore, the mechanism of circular steel tube confined UHPC columns was examined using the established FEM. Based on the results of FEM, the confining pressures along the height of each modeled column were shown. Furthermore, the interaction between the steel tube and the UHPC core was displayed through the slip length and shear stresses between two surfaces of two materials.

Application of Extreme Learning Machine (ELM) and Genetic Programming (GP) to design steel-concrete composite floor systems at elevated temperatures

  • Shariati, Mahdi;Mafipour, Mohammad Saeed;Mehrabi, Peyman;Zandi, Yousef;Dehghani, Davoud;Bahadori, Alireza;Shariati, Ali;Trung, Nguyen Thoi;Salih, Musab N.A.;Poi-Ngian, Shek
    • Steel and Composite Structures
    • /
    • v.33 no.3
    • /
    • pp.319-332
    • /
    • 2019
  • This study is aimed to predict the behaviour of channel shear connectors in composite floor systems at different temperatures. For this purpose, a soft computing approach is adopted. Two novel intelligence methods, including an Extreme Learning Machine (ELM) and a Genetic Programming (GP), are developed. In order to generate the required data for the intelligence methods, several push-out tests were conducted on various channel connectors at different temperatures. The dimension of the channel connectors, temperature, and slip are considered as the inputs of the models, and the strength of the connector is predicted as the output. Next, the performance of the ELM and GP is evaluated by developing an Artificial Neural Network (ANN). Finally, the performance of the ELM, GP, and ANN is compared with each other. Results show that ELM is capable of achieving superior performance indices in comparison with GP and ANN in the case of load prediction. Also, it is found that ELM is not only a very fast algorithm but also a more reliable model.

A Study on the Evaluation of Stability due to Ground Deterioration of Slope (사면의 지반 열화로 인한 안정성 평가에 관한 연구)

  • Han, Young-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.12
    • /
    • pp.83-92
    • /
    • 2018
  • The lapse of time may cause in the slope structure various deterioration phenomenon progresses in the ground of slope, and collapse due to deterioration of strength, resulting in a decrease in the service life. The approach to slope stability due to the ground deterioration is a different concept from the existing limit equilibrium analysis, which is limited to the physical characteristics and geometrical structure of ground. In this study, we conducted a comparative analysis of various literature studies related to the slope failure characteristics and behaviors to presented the optimal formulas for shear strength reduction, such as the exponential function, the logarithmic function and the inverse hyperbolic function. And then a case study was performed on cut slope of Gyeongbu High Speed Rail construction site along the Yangsan fault zone, where the slope failure of shale layer vulnerable to deterioration occurred. As a result, it was confirmed that landslide occurred due to reduction of shear strength by deterioration, as safety factor is approx. 1.0 at the time when the slope failure occurred. Based on the comprehensive case study, as a quantitative approach to the evaluation of slope stability due to deterioration of ground, finally we propose a method for evaluating slope stability with optimal strength reduction curves.

An Experimental Study on the Fatigue Flexural Bonding Characteristic of Concrete Beam Reinforced with GFRP Rebar (GFRP Rebar로 보강된 콘크리트보의 피로 휨·부착성능에 관한 실험적 연구)

  • Oh, Hong Seob;Sim, Jong Sung;Kang, Tae-Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.1
    • /
    • pp.101-108
    • /
    • 2008
  • This study is to examine bond strength of beam reinforced with GFRP rebar under 4-point fatigue bending test by adopting BRITISH STANDARD. The variables were made to have bonding length of 5times(5db), and 15times(15db) of the nominal diameter of GFRP rebar and were done to analyze the relationship between the bonding strength and the slip. In the result of the test, pull-out failure was dominant in the 5db specimen, patterns of the pull-out failure and concrete shear failure appeared in the 15db specimen showed only concrete shear failure at the end of bonding length. Therefore, The strain development consist of three different stage : A rapid increases form 0 to about 10% of total fatigue life. A uniform increases form 10% to about 70%~90%. Then a rapid increases until failure, if failure takes place. It seems that stress level has not influence on the secant modules of elasticity. And also according to the outcome the existing strengthening method came out to be the most superiority in S-N graphs.

Deformation history of Precambrian metamorphic rocks of Sobaegsan Massif in Giseong-myeon area, Uljin-gun, Gyeongsangbuk-do, Korea (경상북도 울진군 기성면 지역에서 소백산육괴 선캠브리아기 변성암류의 변형작용사)

  • Kang Ji-Hoon;Kim Nam-Hoon;Song Yong-Sun;Park Kye-Hun
    • The Journal of the Petrological Society of Korea
    • /
    • v.15 no.2 s.44
    • /
    • pp.49-59
    • /
    • 2006
  • This study clarifies the deformation history of Precambrian metamorphic rocks of Sobaegsan Massif (Wonnam Formation, Pyeonghae granite gneiss, Hada leucogranite gneiss) in Giseong-myeon area, Uljin-gun, Korea. It is based on the geometric and kinematic features and the developing sequence of multi-deformed rock structures. It also reviews the extension of Yecheon Shear Zone and the relative occurrence time of each deformation phase from previous researches. It suggests that the geological structure was formed at least through five phases of deformation after formation of their gneissosity or schistosity. (1) The first phase of deformation took placed under compression of ENE-WSW direction, forming NNW trending regional foliation and very tight isoclinal fold. The general trend of gneissosity or schistosity is inferred to be ENE before the first phase of deformation, being rearranged into NNW by the isoclinal folding. (2) The second phase of deformation formed ENE trending regional foliation and tight, isoclinal, rootless intrafolial folds under compression of NNW-SSE direction [occurrence time: after deposition (Permian age) of Dongsugok Formation, Pyeongan Croup, Janggunbong area]. (3) The third phase of deformation occurred by dextral ductile shearing on the regional foliation, forming stretching lineation of ENE trend and S-C mylonitic structure (after intrusion of Hesozoic homblende granite, Sangunmyeon area-before intrusion of Mesozoic Chunyang granite, Janggunbong area). (4) The fourth phase occurred under (E)NE-(W)SW compression, forming (N)NW trending open fold. (5) The fifth phase took place under N-S compression, forming NNE and NNW trending conjugate strike-slip faults, E-W trending thrust-slip faults, and drag folds related to these fault movements. The deformed structures of fourth and fifth phases result from tectonic movement associated with the developing of the Gyeongsang Basin in Cretaceous age, and it partially rearranged the general ENE trend of the regional foliation in the study area. It also suggests that the Yecheon Shear Zone of E-W trending extends into this area but the ductile shear deformation is weakly developed.