• 제목/요약/키워드: shear behavior and performance

검색결과 661건 처리시간 0.026초

강섬유를 보강한 슬래브-기둥 시스템의 거동에 관한 연구 (The Effects of Steel Fibers on the Behavior of Slab-Column System)

  • 최응규;강경수;김묵한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.553-558
    • /
    • 1998
  • Two-way slab-column specimens were tested under monotonic loading increased up to punching shear failure to investigate the beneficial effects of fiber-reinforced concrete. The parameters for experiments are the placement of fibers within the immediate column region, the placement on the entire surface of the slab, and no placement of fibers. The effects of these parameters on the punching shear capacity, negative moment cracking. and stiffness of the two-way slab specimens were studied. According to the results the addition of steel fibers in the slab around the column results in a significant improvement in the performance including the increase of punching shear resistance, greater post-cracking stiffness and smaller crack width at service load levels.

  • PDF

형상비 4.0이고 축방향철근비 2.36 ~ 4.71%인 팔각형 중공단면 철근콘크리트 기둥의 파괴거동에 관한 실험적 연구 (Experimental Study on the Failure Behavior of RC Octagonal Hollow Section Columns with Aspect Ratio of 4.0 and Longitudinal Steel Ratio of 2.36 ~ 4.71%)

  • 고성현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권6호
    • /
    • pp.102-111
    • /
    • 2022
  • 본 논문의 목적은 팔각형 중공단면 철근콘크리트 교각의 내진성능을 평가하고 축방향철근비가 파괴거동에 미치는 영향을 분석함에 있다. 축소모형 팔각형 중공단면 기둥 실험체 4개를 제작하여 일정한 축력 하에서 반복 횡하중을 가력하는 실험을 수행하였다. 모든 실험체의 횡방향 나선철근 체적비는 0.206%로 일정하고 축방향철근비는 2.36 ~ 4.71%이다. 파괴거동과 내진성능을 분석하였고 겹침이음 실험체를 제외한 3개의 실험체는 최종단계에서 휨-전단 파괴거동을 보였다. 겹침이음 실험체를 제외한 실험결과에서 변위연성도와 누적 에너지소산 능력이 축방향철근비에 반비례하여 감소하는 경향을 나타내었다.

Flexural performance of double skin composite beams at the Arctic low temperature

  • Yan, Jia-Bao;Dong, Xin;Wang, Tao
    • Steel and Composite Structures
    • /
    • 제37권4호
    • /
    • pp.431-446
    • /
    • 2020
  • This paper presents the flexural performance of double skin composite beams (DSCBs) at different Arctic low temperatures. 12 DSCBs were prepared and tested under two-point loading at different Arctic low temperatures of 20, -30, -50, and -70℃. The studied parameters include low-temperature level (T), steel-faceplate thickness (t), shear span ratio (λ), and spacing of headed studs (S). The experimental investigations under two-point loading tests showed that flexural failure occurred to all DSCBs, even including the specimen designed with the small λ ratio of 2.9. The ultimate strength behaviours of DSCBs were improved due to the improved mechanical properties of constructional materials and the confinement on shear connectors. The DSCB subjected to two-point loading and low temperatures exhibits a five-stage working mechanism. The stiffness and strength indexes of DSCBs increase linearly with temperature and t value increasing, while decreasing as shear span ratio boosts. In the contrast, the change of S value from 150 to 200 mm has little effect on the ultimate strength behavior of DSCB.

Experimental shear strengthening of GFRC beams without stirrups using innovative techniques

  • Hany, Marwa;Makhlouf, Mohamed H.;Ismail, Gamal;Debaiky, Ahmed S.
    • Structural Engineering and Mechanics
    • /
    • 제83권4호
    • /
    • pp.415-433
    • /
    • 2022
  • Eighteen (18) (120×300×2200 mm) beams were prepared and tested to evaluate the shear strength of Glass Fiber Reinforced Concrete (GFRC) beams with no shear reinforcement, and evaluate the effectiveness of various innovative strengthening systems to increase the shear capacity of the GFRC beams. The test variables are the amount of discrete glass fiber (0.0, 0.6, and 1.2% by volume of concrete) and the type of longitudinal reinforcement bars (steel or GFRP), the strengthening systems (externally bonded (EB) sheet, side near-surface mounted (SNSM) bars, or the two together), strengthening material (GFRP or steel) links, different configurations of NSM GFRP bars (side bonded links, full wrapped stirrups, side C-shaped stirrups, and side bent bars), link spacing, link inclination angle, and the number of bent bars. The experimental results showed that adding the discrete glass fiber to the concrete by 0.6%, and 1.2% enhanced the shear strength by 18.5% and 28%, respectively in addition to enhancing the ductility. The results testified the efficiency of different strengthening systems, where it is enhanced the shear capacity by a ratio of 28.4% to 120%, and that is a significant improvement. Providing SNSM bent bars with strips as a new strengthening technique exhibited better shear performance in terms of crack propagation, and improved shear capacity and ductility compared to other strengthening techniques. Based on the experimental shear behavior, an analytical study, which allows the estimation of the shear capacity of the strengthened beams, was proposed, the results of the experimental and analytical study were comparable by a ratio of 0.91 to 1.15.

대각철근을 갖는 고성능 섬유보강 시멘트 복합체 연결보의 이력거동 평가 (Cyclic Behavior of High-Performance Fiber-Reinforced Cement Composite Coupling Beam Having Diagonal Reinforcement)

  • 권현욱;전용률;이기학;신명수;한상환
    • 콘크리트학회논문집
    • /
    • 제25권6호
    • /
    • pp.649-656
    • /
    • 2013
  • 병렬전단벽시스템은 경제적이고 효율적인 구조시스템이지만, 연결보의 복잡한 철근상세가 요구된다. 이를 보완하고자 ACI-318에서는 개선된 철근상세를 제안하고 있지만 과도한 횡보강근으로 현장 적용에 어려움이 따른다. 이 연구에서는 횡보강 철근량을 감소시킨 대각철근을 갖는 HPFRCC 연결보 상세를 제안하고, 형상비 2.0 실험체를 통해 현행 기준에 만족하는 대각철근을 갖는 철근콘크리트 연결보와 이력거동을 비교 평가하였다. 그 결과, HPFRCC의 횡구속 효과를 확인하였고, 횡구속 철근을 기준의 1/2로 배근하고 HPFRCC로 보강한 연결보는 현행기준에 따른 연결보와 유사한 내진성능을 보였다. HPFRCC 보강을 통해 대각보강된 철근콘크리트 연결보의 횡구속 철근량을 감소시킴으로써 철근상세의 단순화가 가능할 것으로 판단된다.

Tensile capacity of mortar-filled rectangular tube with various connection details

  • Kim, Chul-Goo;Kang, Su-Min;Eom, Tae-Sung;Baek, Jang-Woon
    • Steel and Composite Structures
    • /
    • 제44권3호
    • /
    • pp.339-351
    • /
    • 2022
  • A mortar-filled rectangular hollow structural section (RHS) can increase a structural section property as well as a compressive buckling capacity of a RHS member. In this study, the tensile performance of newly developed mortar-filled RHS members was experimentally evaluated with various connection details. The major test parameters were the type of end connections, the thickness of cap plates and shear plates, the use of stud bolts, and penetrating bars. The test results showed that the welded T-end connection experienced a brittle weld fracture at the welded connection, whereas the tensile performance of the T-end connection was improved by additional stud bolts inserted into the mortar within the RHS tube. For the end connection using shear plates and penetrating stud bolts, ductile behavior of the RHS tube was achieved after yielding. The penetrating bars increased load carrying capacity of the RHS. Based on the analysis of the load transfer mechanism, the current design code and test results were compared to evaluate the tensile capacity of the RHS tube according to the connection details. Design considerations for the connections of the mortar-filled RHS tubes were also recommended.

Seismic behavior of full-scale square concrete filled steel tubular columns under high and varied axial compressions

  • Phan, Hao D.;Lin, Ker-Chun
    • Earthquakes and Structures
    • /
    • 제18권6호
    • /
    • pp.677-689
    • /
    • 2020
  • A building structural system of moment resisting frame (MRF) with concrete filled steel tubular (CFST) columns and wide flange H beams, is one of the most conveniently constructed structural systems. However, there were few studies on evaluating seismic performance of full-scale CFST columns under high axial compression. In addition, some existing famous design codes propose various limits of width-to-thickness ratio (B/t) for steel tubes of the ductile CFST composite members. This study was intended to investigate the seismic behavior of CFST columns under high axial load compression. Four full-scale square CFST column specimens with a B/t of 42 were carried out that were subjected to horizontal cyclic-reversal loads combined with constantly light, medium and high axial loads and with a linearly varied axial load, respectively. Test results revealed that shear strength and deformation capacity of the columns significantly decreased when the axial compression exceeded 0.35 times the nominal compression strength of a CFST column, P0. It was obvious that the higher the axial compression, the lower both the shear strength and deformation capacities were, and the earlier and faster the shear strength degradation occurred. It was found as well that higher axial compressions resulted in larger initial lateral stiffness and faster degradation of post-yield lateral stiffness. Meanwhile, the lower axial compressions led to better energy dissipation capacities with larger cumulative energy. Moreover, the study implied that under axial compressions greater than 0.35P0, the CFST column specimens with B/t limits recommended by AISC 360 (2016), ACI 318 (2014), AIJ (2008) and EC4 (2004) codes do not provide ultimate interstory drift ratio of more than 3% radian, and only the limit in ACI 318 (2014) code satisfies this requirement when axial compression does not exceed 0.35P0.

탄소섬유 폴리머로 전단보강 후 동결융해 환경에 노출된 철근콘크리트 보의 구조성능 (Structural Performance of Reinforced Concrete Beams Exposed to Freeze-Thawing Environment After Strengthening in Shear with Carbon Fiber-Reinforced Polymer(CFRP))

  • 송선화;김선우;박완신;최기봉;윤현도
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권6호통권58호
    • /
    • pp.115-125
    • /
    • 2009
  • 건축물의 보수 보강 시 섬유보강 폴리머를 이용한 부착공법을 이용한 보수 보강이 행해지고 있으며, 특히 CFRP(carbon fiber reinforced polymer)는 이러한 RC 구조부재의 보강재로 널리 활용되고 있다. 그러나 외부 환경적 요인에 의해 열화되는 즉, 동결융해 환경이 RC 보에서의 CFRP 보강성능에 미치는 영향에 관한 연구는 전무한 실정이다. 따라서 본 연구에서는 AE 기법을 통해 CFRP와 RC 부재 내부의 손상진전에 따라 발생하는 AE 신호를 계측함으로써 CFRP로 보강 후 동결융해에 의해 열화된 RC 구조물의 파괴기구 규명을 위한 기초자료를 마련하고자 한다.

지지조건 변화에 따른 양개형 방폭문의 구조거동 유한요소해석 (FE Analysis on the Structural Behavior of a Double-Leaf Blast-Resistant Door According to the Support Conditions)

  • 신현섭;김성욱;문재흠;김원이
    • 한국전산구조공학회논문집
    • /
    • 제33권5호
    • /
    • pp.339-349
    • /
    • 2020
  • 외피 구조로서의 강박스와 내부의 철근콘크리트 슬래브로 구성되는 양개형 방폭문은 방호 및 대피 구조물의 출입구에 설치되는 구조체이다. 방폭문과 그 후면의 벽체 사이에는 일정의 설치 간격이 존재하게 되는데, 이로 인한 지지조건 및 구조거동의 변화는 방폭 해석 및 설계에 적절히 고려되지 않고 있다. 본 연구에서는 설치 간격에 의한 지지조건 및 폭압의 변화에 따른 방폭문의 구조응답 및 파괴거동을 유한요소 해석방법으로 비교·분석하였다. 해석 결과에 따르면, 설치 간격 및 폭압의 변화는 방폭문의 최대 처짐 및 영구 처짐과 같은 처짐 거동에 영향을 미치며, 설치 간격이 크고 작음에 따라 방폭문과 벽체의 충돌 접촉 정도 및 이에 의한 충격력이 크게 변화하는 것으로 나타났다. 또한, 방폭문에 작용하는 이와 같은 충격력의 변화는 슬래브의 전단파괴와 같은 파괴거동에 영향을 미치는 주요 요인으로 분석되었다. 설치간격 10mm 미만의 방폭문은 전단파괴에 취약해지고, 15mm 내외 수준인 경우가 휨성능 발현에 비교적 더 적합한 것으로 나타났다. 본 연구에서는 설치 간격 및 폭압과 같이 기본적인 조건의 변화에 한해서 비교 해석을 하였다. 향후, 부재 재원 및 강도변화, 전단설계 여부 등 다양한 변수에 따른 구조거동 변화에 대해 실험적 및 해석적 연구가 필요하다.

압축강도 수준을 고려한 강섬유 보강 UHPC와 역T형 강재 합성보의 휨거동 실험 연구 (A Study on the Experiment of Flexural Behavior of Composite Beam with Steel Fiber Reinforced UHPC and Inverted-T Steel Considering Compressive Strength Level)

  • 유성원;서정인
    • 콘크리트학회논문집
    • /
    • 제27권6호
    • /
    • pp.677-685
    • /
    • 2015
  • 최근 일반적인 콘크리트의 단점인 낮은 인장강도 및 휨강도와 취성파괴를 극복하기 위하여 초고성능 콘크리트에 강섬유를 혼입한 강섬유 보강 초고성능 콘크리트(UHPC)에 대한 연구가 주목받고 있다. 본 논문에서는 UHPC의 장점을 극대화하기 위하여 합성보 구성 시에 강재 거더의 상부 플랜지를 없앤 역T형 거더를 적용하여, 콘크리트 압축강도, 섬유 혼입률, 전단연결재 간격 및 바닥판 두께 등의 변수를 가지는 역T형 거더와 UHPC 바닥판을 합성한 합성보를 16 개 제작하고 전단연결재의 거동, 휨거동 특성 등을 실험적으로 파악하고자 하였다. 실험결과를 기준으로 볼 때, 향후 UHPC의 경우 스터의 간격은 100 mm에서 바닥판 두께의 2 또는 4 배 사이로 규정함이 적절할 것으로 예상된다. 또한 대부분 실험 부재의 특성 상대변위는 Eurocode-4의 기준을 만족하므로 연성 거동을 확보하는 것으로 판정되었으며, 전단연결재 간격이 넓은 부재는 설계식의 값보다 실험값이 크게 나와, 비합성 거동 후 UHPC와 강재로 전단연결재 예상저항하중보다 더 큰 극한강도를 발휘하며, 전단연결재 간격이 좁은 부재는 전단연결재가 스스로의 능력에 도달하기 전에 UHPC 상연에서 압축파괴가 급격히 발생됨을 알 수 있었다.