• Title/Summary/Keyword: sharpness metric

Search Result 13, Processing Time 0.017 seconds

Detectability Evaluation for Alert Sound in an Electric Vehicle (전기자동차의 경고음에 대한 인지성 평가)

  • Han, Man Uk;Lee, Sang Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.10
    • /
    • pp.923-929
    • /
    • 2017
  • Generally, the sound emitted from a vehicle powered by an electric motor is lower than that of internal combustion engine vehicles. Therefore, pedestrians often cannot detect approaching electric vehicles. Therefore, a certain additional warning sound is required for these types of automobiles. In this study, to develop an audible warning sound, nine warning sounds are designed based on signal processing and chord theory. The background noise measured on the road is also added to these synthetic sounds. The detectability of these warning sounds is evaluated by subjective tests. The sound metric is correlated to detectability and is investigated through psychoacoustic theory and subjective evaluation. It is determined that known psychoacoustic parameters such as loudness, sharpness, and roughness have a low correlation with detectability. However, it is found that the interval of harmonic sound correlates well with detectability.

Sound quality metrics to express the discomfort of overload excavator noise during operation (과부하 굴삭기 소음의 불쾌감 표현인자)

  • Sim, Sangdeok;Song, Ohseop
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.3
    • /
    • pp.147-155
    • /
    • 2018
  • In this paper, we tried to find out sound quality metrics to express discomfort of overload excavator noise and to develop sound quality indexes through multiple regression analysis by using them. For this purpose, the interior noise of cabin under overload condition was recorded for six excavator models with different noise properties and Jury test was carried out by PCM (Paired Comparison Method) and MEM (Magnitude Estimation Method). Jury test result with low consistency was classified into two groups with different preference tendencies by cluster analysis and multiple regression analysis was conducted in order to find out which sound quality metrics have significant effects on discomfort(low preference). As a result, we figured out that the sound quality metrics to express the discomfort were the partial loudness (= $PN_{10Bark}$) between 0 and 10 Bark in case of group1 and the difference between engine noise(= $dB_{EG}$) and hydraulic system noise ($dB_1$) in case of group2. Using the results of preference ranking and tendency analysis of PCM followed by the correlation analysis between PCM and MEM, the more reliable results were adopted by excluding the data with low consistency obtained from Jury test via MEM.

MRI Findings of the Repaired Anterior Cruciate Ligament (전방 십자 인대의 일차 봉합술 후 MRI 소견)

  • Kim, Jung-Man;Koh, In-Jun;Lee, Dong-Yeob;Lee, Yoon-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.14-21
    • /
    • 2009
  • Purpose: To investigate MRI findings of the repaired anterior cruciate ligament (ACL). Materials and Methods: Seventeen of arthroscopic ACL primary repair with sutures pull-out technique were followed for 21.4 months (range: 12 to 60 months). Stability was assessed with physical examination and KT-1000 arthrometer (MED metric, San Diego, CA) and postoperative MRI checked with time. The patients were divided into 2 groups according to the location of tear which was defined with the location of remained synovial sleeve. Group I (11 patients) comprised that the tear was located within proximal 1/3 of ACL substance and group II (6 patients) comprised below proximal 1/3. MRI findings of the repaired ACL were evaluated by its course, sharpness, thickness and signal intensity using 3 grade system and correlated with its location of tear. Results: In all cases, Lachman test and flexion-rotation drawer test were negative, pivot-shift test was less than grade 1 and the mean side-to-side difference by use of KT-1000 arthrometer was 1.4 mm (range: -1.0 to 2.5 mm). The overall continuity of the repaired ACL was well maintained in all cases. However, mild sagging was observed in 10 cases(58.8%), mild obscure contour in 6 cases (35.3%), increased thickness in 8 cases (47.1%) and slight increased signal intensity in 5 cases (29.5%). There was no statistical significance in all parameters between 2 groups. And a focal defect at the femoral attachment site in sagittal image was observed in 7 cases (41.2%) of all patients which comprised 2 cases (18.2%) of group I and 5 cases (83.3%) of group II. It was observed more frequently in group II with statistical significance (p=0.035). Conclusion: Some abnormal MRI findings such as mild sagged course, obscure contour, increased thickness and signal intensity, the focal defect at femoral attachment site could be observed even though the stability was well maintained clinically. We thought that the focal defect was affected by the location of tear of ACL.

  • PDF