• 제목/요약/키워드: shaking-table testing on TLCD

검색결과 4건 처리시간 0.025초

실시간 하이브리드 실험법을 이용한 동조액체기둥감쇠기가 설치된 구조물의 지진응답 제어성능 평가 (Performance Evaluation of Controlling Seismic Responses of a Building Structure with a Tuned Liquid Column Damper using the Real-Time Hybrid Testing Method)

  • 정희산;이성경;박은천;민경원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.669-673
    • /
    • 2007
  • In this study, real-time hybrid test using a shaking table for the control performance evaluation of a U-shaped TLCD controlling the response of earthquake-excited building structure is experimentally implemented. In the test, the building structure is used as a numerical part, on which a U-shaped TLCD adopted as an experimental part was installed to reduceits response. At first, the force that is acting between a TLCD and building structure is measured from the load cell attached on shaking table and is fed-back to the computer to control the motion of shaking table. Then, the shaking table is so driven that the error between the interface acceleration computed from the numerical building structure with the excitations of earthquake and the fed-back interface force and that measured from the shaking table. The control efficiency of the TLCD used in this paper is experimentally confirmed by implementing this process of shaking table experiment on real-time.

  • PDF

Experimental study of controllable MR-TLCD applied to the mitigation of structure vibration

  • Cheng, Chih-Wen;Lee, Hsien Hua;Luo, Yuan-Tzuo
    • Smart Structures and Systems
    • /
    • 제15권6호
    • /
    • pp.1481-1501
    • /
    • 2015
  • MR-TLCD (Magneto-Rheological Tuned Liquid Column Damper) is a new developed vibration control device, which combines the traditional passive control property with active controllability advantage. Based on traditional TLCD governing equation, this study further considers MR-fluid viscosity in the equation and by transforming the non-linear damping term into an equivalent linear damping, a solution can be obtained. In order to find a countable set of parameters for the design of the MR-TLCD system and also to realize its applicability to structures, a series of experimental test were designed and carried out. The testing programs include the basic material properties of the MR-fluid, the damping ratio of a MR-TLCD and the dynamic responses for a frame structure equipped with the MR-TLCD system subjected to strong ground excitations. In both the analytical and experimental results of this study, it is found that the accurately tuned MR-TLCD system could effectively reduce the dynamic response of a structural system.

TMD와 TLCD를 이용한 2방향 감쇠기의 동적특성 (Dynamic Characteristic of A Bi-dirctional Damper Using A Tuned Mass Damper and A Tuned Liquid Column Damper)

  • 이성경;민경원;박은천
    • 한국전산구조공학회논문집
    • /
    • 제21권6호
    • /
    • pp.589-596
    • /
    • 2008
  • 본 연구에서는 동조질량감쇠기(TMD)와 동조액체 기둥감쇠기(TLCD)로 구성된 2방향 감쇠기의 제어성능을 실험적으로 검증하였다. 본 연구에 사용된 감쇠기는 한방향으로는 TMD로 거동하고, 다른 직교하는 방향에서는 TLCD로 거동하여 제어력이 발생하는 감쇠기이다. 우선, 제작된 감쇠기의 동적특성과 TMD와 TLCD에 의해 발생하는 제어력들의 연계효과를 조사하기 위한 진동대 실험을 수행하였다. 다음으로 이러한 실험결과를 바탕으로 감쇠기의 동적특성에 영향을 미치는 파라미터를 정량적으로 평가하였다. 본 연구에서 사용된 감쇠기가 입사각을 갖는 진동에 의해 가진될 때 TMD와 TLCD에 의해 연계된 제어력이 발생하는 것을 진동대 실험결과로부터 확인하였다. 또한, 감쇠기가 건축물의 2방향 응답제어에도 효과적으로 사용될 수 있음을 확인하였다.

TLCD와 LCVA의 설계파라미터에 대한 실험적 평가 (Experimental Evaluation of Design Parameters for TLCD and LCVA)

  • 이성경;민경원;박지훈
    • 한국전산구조공학회논문집
    • /
    • 제22권5호
    • /
    • pp.403-410
    • /
    • 2009
  • 본 연구에서는 실험결과를 바탕으로 액체형 기둥감쇠기의 감쇠계수와 제어력에 참여하는 유효질량을 시스템 식별기법을 이용하여 정량적으로 평가하였다. 먼저, 두가지 형태의 동조액체형 기둥감쇠기를 제작하여 진동대 실험을 실시하였다. 다음으로 수조내부 액체의 수위를 변화시켜 가면서 조화하중 가진실험에 의한 감쇠기의 동적특성을 실험적으로 구하였다. 마지막으로 수치해석 모델과 실험결과와의 오차를 최소화하는 것에 의해 수위변화에 따른 감쇠기의 감쇠비와 유효질량을 정량적으로 평가하였다. 시스템 식별결과로부터 감쇠비와 유효질량이 감쇠기의 수위가 증가함에 따라 감소하는 것으로 나타났다.