• 제목/요약/키워드: shaking test

검색결과 540건 처리시간 0.024초

점탄성물질 난류댐퍼를 이용한 V형 철골 브레이스 골조의 진동응답해석 (A Vibration Response Analysis of Steel Building Frame with V Shape Brace Vibrationally Controlled by Turbulent Flow Dampers Sealed by Visco-Elastic Material)

  • 이호;이상엽
    • 한국공간구조학회논문집
    • /
    • 제2권3호
    • /
    • pp.103-113
    • /
    • 2002
  • This thesis investigates vibration response characteristics of building frames in which dampers are installed. The frames belong to passively vibration-controlled. Structures which utilizes energy dissipation of mechanical dampers provided in the structure. In this thesis, a turbulent flow damper sealed by visco-elastic material was dealt with as the device of passive vibration control. To investigate the resisting force characteristics of the damper, harmonic vibratration tests were carried out. Based on the test results, a theoretical model of the damper resistance was presented and a method of identifying the model parameters was proposed. Shaking table tests of the frame with and without the dampers were carried out and the effectiveness of the damper was examined. The response of the frame with the dampers was reduced to 1/2 or 1/3 of the cases without the damper.

  • PDF

1/12 축소 철근콘크리트 상부벽식-하부골조 건축물의 진동대 실험 (Shaking Table Tests of 1/12-Sale R.C. Bearing-Wall system with Bottom Piloti Frames)

  • 이한선;고동우;권기현;김병현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.407-414
    • /
    • 2001
  • The severe shortage of the available sites in the highly developed downtown area in Korea necessitates the construction of high-rise buildings which meet the need of residence and commercial activity simultaneously. The objective of this study is to investigate the seismic performance of this type of building structures. For this purpose, two 1 :12 scale 17-story reinforced concrete model structures were constructed according to the similitude law, in which the upper 15 stories have a bearing-wall system while the lower 2-story frames have two different layouts of the plan The one is a moment-resisting frame system and the other is a moment-resisting frame system with a infilled shear wall. Then, this model was subjected to a series of earthquake excitations. The test results show that the existence of shear wall reduced the shear deformation at the piloti frame, but has almost the negligible effect on the reduction of the overturning-moment angle.

  • PDF

마찰진자베어링(FPS) 면진시스템을 적용한 원전주제어실의 진동대 실험 (Experimental Study on Floor Isolation of Main Control Room of Nuclear Power Plant using FPS(Friction Pendulum System))

  • 이경진;함경원;서용표
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.445-452
    • /
    • 2005
  • The seismic characteristics with Friction Pendulum System have been studied using a shaking table system. In this study, we made two kind of floor system (Type I, Type II) and several seismic tests with and without isolation system were conducted to evaluate floor isolation effectiveness of Friction Pendulum System. Both type have showed large reduction effectiveness in acceleration, response spectra but Type II have showed lower acceleration and lower first mode in response spectra, compared to type I. On the basis of test results and consideration of application, it is found that type II is more suitable for floor model of main control room of Nuclear Power Plant.

  • PDF

응답의 피크분포에 기초한 마찰감쇠기의 등가선형화 (Equivalent linearization of friction damper and brace system based on peak distribution)

  • 박지훈;민경원;문병욱
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.437-444
    • /
    • 2005
  • An equivalent linearization technique based on Rayleigh peak distribution for friction damper and brace system (FDBS) under stochastic excitation is proposed. For verification, shaking table test of a small scale 3-story building model with the FDBS is conducted for various slip moment levels. Using experimental result, equivalent linearization of the FDBS is conducted based on Rayleigh peak distribution, which is compared with measured peak distribution. For comparative study, model updating technique is applied based on identified modal properties. Finally, complex modal analysis and time history analysis for the obtained equivalent linear systems are conducted and compared with experimental result.

  • PDF

진동대 실험을 통한 스프링클러 설비의 내진성능 평가 (Seismic Performance Evaluation of Sprinkler Facilities throughout Shaking Table Test)

  • 남민준;박승희;김동준;윤종구;서춘교
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.54-57
    • /
    • 2012
  • 지진에 의한 2차 피해 중 화재로 인한 피해가 거의 대부분이다. 따라서, 소화설비의 내진설계는 반드시 필요하며 소화능력을 유지해야 한다. 본 연구에서는 진동대 실험을 통하여 스프링클러 설비의 내진성능을 평가하였다. 스프링클러 설비의 내진성능을 평가하기 위하여 일반 설비와 내진처리가 된 설비를 동시에 시공하여 그 성능을 평가하였다. 또한, 시설물의 거동특성을 파악하기 위하여 시설별 변위응답, 가속도 응답, 가속도 응답스펙트럼을 통하여 시설물에 대한 내진성능을 평가하였다.

  • PDF

상대강성비를 고려한 지진격리교량의 응답특성 (Seismic Responses of Isolated Bridges Considering the Relative Stiffness Ratio)

  • 서현우;김남식;정진환
    • 한국소음진동공학회논문집
    • /
    • 제15권12호
    • /
    • pp.1340-1346
    • /
    • 2005
  • In this study, based on shaking table test results on a seismically isolated bridge model, an inelastic numerical model is refined by using Bouc-Wen model representing the hysteretic behavior of isolators. Seismic responses of isolated bridges are numerically investigated varying with relative stiffness ratio(RSR), which is a ratio of the effective stiffness of isolator to the lateral stiffness of bridge pier, From the results, it is found that an adequate range of relative stiffness ratio could be defined for seismic design of isolated bridges without considering the flexibility of piers.

진동대를 이용한 기존 건축물 내진보강공법에 대한 연구 (The Study on Aseismic Reinforcement Method for Existing Structures Based on Shaking Table Test)

  • 오명호;유병준;박인준;이용교
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 춘계학술논문집 1부
    • /
    • pp.474-477
    • /
    • 2011
  • 본 논문에서는 내진보강공법의 내진성능향상을 평가하기 위하여 진동대실험을 실시하였다. 실험 구조체는 비보강, 보강 구조체로 각각 실규모 크기의 구조체를 2개 제작하였다. 기둥 상, 중, 하부 및 보에 각각 Strain게이지, 가속도계를 설치한 후 설계펙트럼가속도 0.15g의 30~150%까지 가속도를 증가 시키면서 실험을 수행하였다. 그 결과 비 보강 구조체는 0.2g에서 최대 80cm균열이 발생하였으나 보강 구조체는 균열이 발생하지 않았다. Strain의 변화량에서는 비 보강이 보강보다 최대 1700%크게 나타났다. 가속도의 변화량은 비 보강이 176%크게 나타났다. 진동대 실험결과 본 내진보강공법이 내진성능향상에 지대한 영향을 주고 있음이 증명되었다.

  • PDF

탄성감쇠를 가진 건축구조물의 동적해석 (Dynamic Analysis of Building Structures with Viscoelastic Dampers)

  • 이동근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.196-203
    • /
    • 1998
  • Viscoelastic dampers have been successfully applied to building structures for reduction of vibration induced by wind or earthquakes. But accurate estimation of responses of building structures with viscoelastic dampers is very difficult, because the properties of viscoelastic damper is dependent on temperature and frequency of vibration. For efficient control of building vibration, required damping of viscoelastic damping device need be estimated and dynamic analysis method which can estimate the response of building structure with viscoelastic damper system is indispensable. In this paper, an efficient dynamic analysis method of a building structure with viscoelastic dampers is proposed. Efficiency and accuracy of the proposed method are verified comparing analytic results with shaking table test results using reduced building models.

  • PDF

액상화 발생후 과잉간극수압 소산 모델링 (Modelling of Excess Pore Pressure Dissipation After Liquefaction)

  • 김명모;박영호
    • 한국지반공학회논문집
    • /
    • 제17권4호
    • /
    • pp.39-48
    • /
    • 2001
  • 액상화 발생후 과잉간극수압 소산 특성을 파악하기 위하여 포화된 수평 모래지반에 대하여 1-g 진동대시험을 수행하였다. 진동대시험에는 주문진 표준사와 영종도 세사를 사용하였으며 상대밀도를 dir 20~30% 사이가 되도록 조성하였다. 간극수압계, 가속도계 그리고 LVDT 등으로 시험중의 지반거동을 계측하였으며, 4Hz의 sine 파를 0.15g에서 5초간 5회 반복하여 작용시켰다. 진동대시험을 분석한 결과 액상화 발생후 과잉간극수압의 소산속도는 그 지반의 투수성뿐 아니라 과잉간극수압 소산시 입자의 침강거리와 직접 관련이 있는 지반의 침하량에도 크게 영향을 받는 것으로 나타났으며, 이 과정을 침강모래 이론으로 모델링하였을 때 입자의 침강속도와 투수계수 사이의 비례 관계는 침강모래 이론에서의 가정한 것과는 달리 모래의 종류에 따라 차이를 나타내었다. 또한 Terzaghi의 압밀이론으로는 액상화 후 과잉간극수압의 소산과정을 적절히 모사할 수 없었다.

  • PDF

Physical Modeling of Geotechnical Systems using Centrifuge

  • Kim, Dong-Soo;Kim, Nam-Ryong;Choo, Yun-Wook
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.194-205
    • /
    • 2009
  • In geotechnical engineering, the mechanical characteristics of soil, the main material of geotechnical engineering, is highly related to the confining stress. Reduced-scale physical modeling is often conducted to evaluate the performance or to verify the behavior of the geotechnical systems. However, reduced-scale physical modeling cannot replicate the behavior of the full-scale prototype because the reduced-scale causes difference of self weight stress level. Geotechnical centrifuges are commonly used for physical model tests to compensate the model for the stress level. Physical modeling techniques using centrifuge are widely adopted in most of geotechnical engineering fields these days due to its various advantages. In this paper, fundamentals of geotechnical centrifuge modeling and its application area are explained. State-of-the-art geotechnical centrifuge equipment is also described as an example of KOCED geotechnical centrifuge facility at KAIST.

  • PDF