• 제목/요약/키워드: shade guides

검색결과 16건 처리시간 0.02초

자연치와 도재관에 대한 색조선택의 동일성 (Shade Matching Identification of in Vivo Natural Teeth and Porcelain-Fused-to-Metal Crowns)

  • 조홍규
    • 대한치과기공학회지
    • /
    • 제29권1호
    • /
    • pp.35-48
    • /
    • 2007
  • The purpose of this study was to evaluate shade selection using conventional visual assessment in vivo natural teeth and porcelain-fused-to-metal (PFM) crown. Maxillary central incisors, lateral incisors and canines of one hundred twenty four college women were used as vivo natural teeth. Fifty one PFM crown for maxillary central incisor fabricated by dental laboratory were used as experimental materials. Using Vitapan Classical Shade Guides, shade selection of natural teeth was measured by each college woman and shade selection of PFM crown was measured by three ceramists with more than ten years career. Both natural teeth and PFM crown shade selection were measured through Shade Eye-Ex. From the shade selection comparing, following results were obtained. The results were as follows: 1. The shade matching identification of natural teeth between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 27.4% in maxillary central incisor, 13.7% in lateral incisor and 18.5% in canine. 2. Among the shade selection of PFM crown by three ceramists, the shade evaluation of three ceramists were same only in ten cases. In twenty case, those of two ceramists were same. 3. The shade matching identification of PFM crown between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 38.6% in average. These results suggest that the shade selection using conventional visual assessment should be dealt with care in clinic and need a credible method for shade matching color.

  • PDF

광중합형 복합레진과 shade guide의 색차에 관한 연구 (A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides)

  • 임경민;이민호;송광엽
    • 구강회복응용과학지
    • /
    • 제25권1호
    • /
    • pp.13-22
    • /
    • 2009
  • 심미적인 특성을 가진 복합레진은 전치부 수복용 재료로 많이 이용되고 있다. 복합레진 수복 시 만족스러운 결과를 얻기 위해서는 색조의 선택이 중요한 역할을 한다. 현재 대부분의 수복용 복합레진은 Vita Lumin 색조견본(shade guide)이나 각각의 회사에서 제공하는 색조견본을 사용하고 있으나, 색조 견본 사이의 색차와 수복물과 견본 사이에 색차가 예상되어 그 차이를 규명하여 임상적인 선택 시에 도움이 되고자 하였다. 4종의 광중합 복합레진(Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), $Esthet{\cdot}X$ ($E{\cdot}X$))과 A2와 A3의 색조 견본을 사용하였다. 각 재료마다 3개의 시편과 1개의 색조 견본을 제작하였다. Teflon 주형(깊이 1.35 mm, 직경 8 mm)에 각각의 복합레진을 채우고 응축한 후에 중합하여 젖은 사포로 연마하였다. 색조 견본을 연마용 stone과 고무를 이용하여 1.35 mm 두께로 연마하였다. 컴퓨터에 의해 조절되는 spectrophotometer(color i5, GretagMacbeth, USA)를 이용하여 시편과 색조견본의 색의 특성을 CIELAB coordinates ($L^*$, $a^*$, $b^*$)로 평가하였다. CIELAB 계측을 통하여 복합레진과 색조 견본의 색차(${\Delta}E^*ab$)를 비교 평가 하였다. 광원으로는 CIE standard D65를 사용하였다. 다음과 같은 결과를 얻었다. 1. 동일한 shade로 설계된 여러 제조회사의 복합레진 시편의 $L^*$, $a^*$, $b^*$ 값 간에 유의할 만한 수준의 차이를 나타냈다(p<0.05). 2. 동일한 shade로 설계된 여러 제조회사의 복합레진 시편 간에 대부분 육안으로 인지할 만한 색차(${\Delta}E^*ab>3.3$)값을 나타냈다. 3. 동일한 shade로 설계된 여러 제조회사의 복합레진과 제조회사에서 제공되는 shade guide 및 Vita Lumin shade guide 간에 대부분 육안으로 인지할 만한 색차(${\Delta}E^*ab>3.3$)값을 나타냈다. 4. 임상에서 보다 나은 색 조화를 얻어 심미성을 향상시키기 위해서는 실제 수복물로 제작한 custom shade guide의 제작이 필요할 것으로 생각된다. 제조사에 의해 제공되는 색조 견본이나 Vita Lumin 색조 견본은 임상의에게 복합레진의 색조 선택 시에 정확한 기준을 제공하지는 않았고, 대부분의 제품에서 인지할 수 있는 색차가 있었다. 그러므로 보다 나은 색조 선택을 위해 수복용 레진으로 제작한 맞춤형 색조 견본을 사용하는 것을 추천한다.

Shade guide의 형태가 색상 결정에 미치는 영향 (INFLUENCE OF THE SHADE GUIDE DESIGN ON COLOR HATCHING)

  • 박걸;김동준;이시은;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제30권3호
    • /
    • pp.170-177
    • /
    • 2005
  • 본 연구에서는 shade guide를 이용하여 치아의 색상을 결정하는데 있어 shade guide의 형태가 미치는 영향을 평가 하기 위해 시행하였다 8가지 서로 다른 색상 code (Al, A2, Bl, B2, B3, C2, C3, D3)를 사용하는 광중합 복합레진 (Esthet-X, Dentsply, USA)을 이용하여 각 색상마다 상악 중절치 모형, 치아형 shade guide, 도넛형 shade guide, 및 회색 shield를 포함하는 shade guide를 제작하고 무작위로 기호를 부여하였다. 제작된 치아 모형을 배열하고 전남 대학교병원 치과 진료처에 근무하는 19명의 수련의와 전남대학교 치과대학 2, 3학년 학생 65명을 대상으로 회색 배경 판과 D$_{65}$ 표준광 하에서 각 치아의 색상과 일치하는 shade guide를 선택하게 하였다. 연구 결과 Bl 색상은 실험에 적용한 3가지 형태의 모든 shade guide에서 약 95%의 가장 높은 정확도를 보였으며 , 색상간 색차가 가장 적은 B2와 C2는 3가지 형태의 모든 shade guide에서 서로 비슷한 정도의 교차 선택율을 보였다. 또한 관찰자에 상관없이 치아 형태의 shade guide는 가장 높은 정확도를 보인 반면 (p < 0.05), 도넛 형태의 shade guide는 가장 낮은 정확도를 보였다 (p <0.05).

복합레진의 광중합 전·후와 shade guide의 색차 비교 (COLOR DIFFERENCES BETWEEN RESIN COMPOSITES BEFORE- AND AFTER-POLYMERIZATION, AND SHADE GUIDES)

  • 전이주;조성식;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.299-309
    • /
    • 1999
  • The composite resin, due to its esthetic qualities, is considered the material of choice for restoration of anterior teeth. With respect to shade control, the direct-placement resin composites offer some distinct advantages over indirect restorative procedures. Visible-light-cured (VLC) composites allow dentists to match existing tooth shades or to create new shades and to evaluate them immediately at the time of restoration placement. Optimal intraoral color control can be achieved if optical changes occurring during application are minimized. An ideal VLC composite, then, would be one which is optically stable throughout the polymerization process. The shade guides of the resin composites are generally made of plastic, rather than the actual composite material, and do not accurately depict the true shade, translucency, or opacity of the resin composite after polymerization. So the numerous problems associated with these shade guides lead to varied and sometimes unpredictable results. The aim of this study was to assess the color changes of current resin composite restorative materials which occur as a result of the polymerization process and to compare the color differences between the shade guides provided with the products and the actual resin composites before- and after-polymerization. The results obtained from this investigation should provide the clinician with information which may aid in improved color match of esthetic restoration. Five light activated, resin-based materials (${\AE}$litefil, Amelogen Universal, Spectrum TPH VeridonFil-Photo, and Z100) and shade guides were used in this study. Three specimens of each material and shade combination were made. Each material was condensed inside a 1.5mm thick metal mold with 10mm diameter and pressed between glass plates. Each material was measured immediately before polymerization, and polymerized with Curing Light XL 3000 (3M Dental products, USA) visible light-activation unit for 60 seconds at each side. The specimens were then polished sequentially on wet sandpaper. Shade guides were ground with polishing stones and rubber points (Shofu) to a thickness of approximately 1.5mm. Color characteristics were performed with a spectrophotometer (CM-3500d, Minolta Co., LTD). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$ and $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E{^*}ab$) of resin composites before the polymerization process and shade guides using the post-polishing color of the composite as a control, CIE standard D65 was used as the light source. The results were as follows. 1. Each of the resin composites evaluated showed significant color changes during light-curing process. All the resin composites evaluated except all the tested shades of 2100 showed unacceptable level of color changes (${\Delta}E{^*}ab$ greater than 3.3) between pre-polymerization and post-polishing state. 2. Color differences between most of the resin composites tested and their corresponding shade guides were acceptable but those between C2 shade of ${\AE}$litefil and IE shade of Amelogen Universal and their respective shade guides exceeded what is acceptable. 3. Comparison of the mean ${\Delta}E{^*}ab$ values of materials revealed that Z100 showed the least overall color change between pre-polymerization and post-polishing state followed by ${\AE}$litefil, VeridonFil-Photo, Spectrum TPH, and Amelogen Universal in the order of increasing change and Amelogen Universal. Spectrum TPH, 2100, VeridonFil-Photo and ${\AE}$litefil for the color differences between actual resin and shade guide. 4. In the clinical environment, the shade guide is the better choice than the shade of the actual resin before polymerization when matching colors. But, it is recommended that custom shade guides be made from resin material itself for better color matching.

  • PDF

발거된 자연치와 5종 Shade Guide의 색채 계측기를 이용한 색상 비교 (COLORIMETRIC ANALYSIS OF EXTRACTED HUMAN TEETH AND FIVE SHADE GUIDES)

  • 황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.769-781
    • /
    • 1997
  • The tristimulus values of 180 extracted maxillary and mandibular anterior teeth were measured by colorimeter. And it were colnverted to Munsell color order system(Hue, Value, Chroma) and CIE $L^*a^*b^*$ color coordinates. The commonly used Vita, and Bioform shade guides, 2 composite resin shade guides(Prisma APH and Z-100), and a glass-ionomer shade guide(Fuji II) were compared with these teeth. At the middle facial surface, color distributions of teeth were Hue(0.56YR to 9.77Y), Value(2.46 to 7.9), and Chroma(0.14 to 2.02). And the aberaged values and standard deviations for $L^*a^*b^*$ were $63.18{\pm}10.44$, $1.11{\pm}1.66$, and $5.79{\pm}2.36$. The shade guide did not match well with the color space of the human teeth. Especially, the lacks of the Yellow-red Hues and higher values were prominent. Compare with other measurements, the Hues of the teeth measured in this study were broadly distributed(most of ranges in Y and YR were included), while the Value and chroma were shown to the lower.

  • PDF

색조 선택 시스템을 이용한 shade guide의 색조 분석 (Evaluation of shade guide using digital shade analysis system)

  • 이승택;이종혁;신수연
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.1-11
    • /
    • 2009
  • 연구목적: 심미 수복을 위한 색상 결정 방법으로는 색견본 (shade guide)과 치아를 눈으로 직접 비교하는 기존의 비색법과 최근 소개되기 시작한 색상 측정용 기기를 사용하는 방법이 있다. 비색법은 치과의사들과 기공사들 간의 색조 선택에 일관성이 결여되어 있는 등 많은 문제점이 지적되고 있지만 아직도 이러한 방법에 의한 색상 결정과 결정 색상에 대한 표현 방식이 임상 치의학에 적용되고 있다. 본 연구의 목적은 진료실과 기공소에서 사용하고 있는 색견본이 같은 값을 가지는지 ShadeEye - $NCC^{(R)}$ dental chroma meter (Shofu Inc., Kyoto, Japan)로 확인하고 또한 이 측정 기기의 두 가지 모드가 동일한 shade tab을 같은 값으로 인식하는지 확인하고자 하였다. 연구재료 및 방법: 첫 번째 실험에서는 모두 8개의 Vita Lumin Vacuum shade guide (Vident Inc., California, USA)를 모아 그 중 A1과 B1 shade tab을 각각 5회씩 색상 측정용 기기인 ShadeEye-$NCC^{(R)}$의 tooth mode와 porcelain mode로 나누어 색조 분석을 하였고 두 번째 실험에서는 치과 진료실과 기공소에서 실제 사용하고 있는 Vita Lumin Vacuum shade guide를 각각 12개씩 모아 역시 A1과 B1 shade tab을 색상 측정용 기기인 ShadeEye-$NCC^{(R)}$의 tooth mode와 porcelain mode로 나누어 색조 분석을 실시하였다. 결과: 첫 실험에서 8개의 색견본의 A1과 B1의 5회씩 측정에서 두 가지 mode에서 모두 채도 (shade), 명도 (value), 색상 (hue)에서 유의한 차이를 보였다(P<.05). 두 번째 실험에서는 진료실에서 사용하는 색견본과 기공소에서 사용하는 색견본 사이에는 통계적으로 유의한 차이를 보이지 않았으나, A1의 porcelain mode 에서 채도가 유의한 차이를 보여 (P<.05), 같은 shade tab이라 할지라도 채도에서 차이가 날 수 있음을 보였다. 결론: ShadeEye-$NCC^{(R)}$의 mode에 따라 동일한shade tab을 다른 값으로 인식하는 것으로 나타나 진료실과 기공소 간에 동일한 mode로 사용하는 것이 필요할 것으로 사료된다.

가시광선영역에서 shade guide에 따른 광투과도 특성 연구 (ANALYSIS OF OPTICAL TRANSMISSION CHARATERISTICS BY VISIBLE LIGHT INTO SHADE GHIDES)

  • 최근배;박찬운;송창용;고석민
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.147-159
    • /
    • 2000
  • The purpose of this study was the evaluation of spectral transmission of the commercial three shade guides and the relationship of hue, value, and chroma according to the transmission rate. The spectral transmittance of three shade guides - Vita Lumin Shade Guide, Vintage and Unibond Shade Guide, and Vitapan 3D-Master Shade Guide - were measured. For direct transmission measurements, each shade tabs were placed at the entrance port of the 1mm diameter intergrating sphere. The intensity of the light source passing through the shade tabs to the right angle was continuously recorded for wavelength from 400 to 700 nm. A transmission spectrum and digital data were obtained for each measurement and they were evaluated using Microcal Origin program. The obtained results of this study were as follows : 1. In Vita Lumin Shade Guide, sum of the transmission rate of the shade tabs at the wavelength 400-700nm was decreased in agreement with the arrangement order at each A, B, C, D group, except D4 shade tab. However, there were no relationships between the transmission rate of the shade tabs and the value-oriented. 2. In Vintage and Unibond Shade Guide, sum of the total transmission rate of the shade tabs was decreased in agreement with the arrangement order at each A, B, C, B group. When all shade tabs arranged in value-oriented, transmission rate was accord with the order, except D4 shade tab. 3. When shade tabs of the Vitapan 3D-Master Shade Guide have the same value and hue, sum of their total transmission rate decreased in accordance with the chroma-oriented. When the shade tabs have the same value and chroma, there were no differences from the order of the transmission rate to the various hue type. However, in the 'R' tabs of reddish hue type, the transmission rate increased at the long wavelength range area. In conclusion, we need the quantitative analyzing instruments in transmission determination. Vitapan 3D-Master Shade Guide covers the tooth color space taking into account the parameters of the systematic value, chroma, hue oriented, and the transmission rate relatively accorded with that sequence.

  • PDF

Effects of eye dominance on shade matching and color perception among the dentist population

  • Pattnaik Kalyani;Kannan Subiksha;Amit Jena;Govind Shashirekha;Saumyakanta Mohanty;Gaurav Sharma
    • Restorative Dentistry and Endodontics
    • /
    • 제48권4호
    • /
    • pp.40.1-40.8
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the influence of eye dominance on color perception, and shade matching. Materials and Methods: A total of 104 participants were selected for the study. There were 3 groups: Group I: 3rd and 4th year dental students and interns (n = 40); Group II: postgraduates (n = 34); Group III: senior residents and faculty members (≥ 6 years of clinical experience) (n = 30). All participants were evaluated for congenital color blindness with Ishihara plates, their dominant eye with Mile's test, and their color perception with the Farnsworth-Munsell 100 hue test. The shade guide test was used for shade matching with a second corresponding set of Vitapan classical shade guides. Results: The results of Mile's test revealed that 60.6% were right-eye dominant and 39.4% were left-eye dominant. There was a statistically significant difference among all participants between the dominant eye and the non-dominant eye in shade matching. Conclusions: The dominant eye has a positive effect on shade matching and the ability to match shades becomes better with an increase in clinical experience.

복합레진과 shade guide의 색차에 관한 연구 (A Study on Color Differences Between Composite Resins and Shade Guides)

  • 김희선;엄정문;강명회
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.107-120
    • /
    • 1996
  • 복합레진은 조작이 용이하고 강도가 우수하며 중합시간이 짧고 법랑질과 상아질에 접착이 가능하며 연마성이 뛰어나고 자연스러운 색상을 나타내므로 심미적 수복에 가장 일반적으로 선택되는 재료의 하나이다. 대부분의 복합레진 kit에는 shade guide가 포함되어 있어 이를 기준으로 중합된 후의 복합레진 색조를 예상하여 선택하게 된다. 그러나 이러한 shade guide들은 대개 복합레진이 아닌 plastic으로 제조된 것으로 중합된 복합레진의 실제 색조와는 차이가 생기게 되며 결국 shade guide 자체의 문제점으로 인해 이상적인 색조선택이 어려워진다. 이에 본 연구에서는 국내에 시판되고 있는 5종의 복합레진 제품을 선정하여 분광 광도계를 이용해서 shade guide와 중합된 복합레진 사이의 색조차이를 측정, 비교 연구하였다. 직경 16mm. 두께 1.6mm의 plastic mold에 5종의 광중합형 복합레진(Z100, Prisma TPH, Tetric, Silux Plus, Herculite XR)을 충전하고 응축기에 넣어 압축한 후 제조사의 지시에 따라 광중합기로 중합시킨 후 mold에서 시편을 제거하여 보관했다가 젖은 sandpaper 상에서 순차적으로 연마하였다. shade guide는 step부분을 갈아내어 복합레진 시편과 동일한 두께로 만든후 연마하였다. 분광광도계에 shade guide를 넣고 CIE illuminant D65 하에서 spectral reflectance를 측정하고 해당 색조의 복합레진 시편도 통일한 방법으로 측정하고 $L^*$, $a^*$, $b^*$값과 ${\Delta}E^*$값을 얻은후 분석하여 다음과 같은 결과를 얻었다. 1. Z100의 D3, A3, B2 shade와 Prisma TPH의 B2 shade를 제외한 모든 시편에서 shade guide와 복합레진간에 육안으로 인지할 수 있는 색차(${\Delta}E^*$ > 1.0)가 관찰되었다. 2. 평균적으로 Z100이 가장 적은 색차를 나타내었고 Prisma TPH, Tetric, Silux Plus, Herculite XR 순으로 색차가 증가하였다. 3. Prisma TPH의 A2 shade. Tetric의 W shade. Silux Plus의 YB, U shade, Herculite XR의 L, LY shade는 ${\Delta}E^*$값이 3.3 이상으로 나타났다. 4. Z100, Prisma TPH, Tetric, Silux Plus에서는 복합레진보다 shade guide가 더 높은 $L^*$값을 보이는 경향이 나타났으며, Herculite XR에서만 복합레진이 더 높은 $L^*$값을 나타냈다. 5. 모든 시편에서 $b^*$ 값은 (+)로 관찰되었고, Z100, Prisma TPH, Tetric, Silux Plus의 shade guide는 복합레진에 비해 높은 $b^*$값을 보였다. 6. 모든 시편에서 $a^*$값은 (-)로 관찰되었고. Herculite XR 및 Silux Plus에서는 복합레진이 shade guide 에 비 해 낮은 $a^*$값을 나타냈다.

  • PDF

육안과 분광 측정기를 이용한 자연 치아의 색조비교분석 (Shade comparative analysis of natural tooth measured by visual and spectrophotometric methods)

  • 김범석;신수연;이종혁
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.443-454
    • /
    • 2008
  • 도재 수복물 제작을 위해 자연치아의 색조를 분석하는 방법으로는 색견본 (shade guide)을 이용하는 시각적인 방법과 기계를 이용하는 방법이 있다. 그중 통상적인 육안 관찰을 통해 색조를 선택하는 것은 임상에서 가장 많이 이용되고 있는 방법이기는 하나 주관적이며 일관되지 않은 결과로 신뢰성의 문제가 제기되었으며 자연치의 색조는 매우 다양하여 같은 치아라 할지라도 부위별로 다양한 색조를 가지기 때문에 단순히 shade tab을 이용한 색조 비교만으로는 정확한 치아의 색조 특성을 나타내는 것이 불가능한 것으로 알려져 있다. 한편 지속적인 기술발달로 computer color matching system, 치과용 비색계, 분광 측정기 등의 기계를 이용한 치아 색조 측정 방법이 이의 대안으로 제시되고 있다. 기계를 이용한 방법은 색조 선택에 있어 객관적이며, 재현성이 있는 정확한 정보를 술자에게 제공한다. 이에 본 연구에서는 광원, 개인, 술자의 숙련도에 따라 육안과 기계를 통한 관찰 시 치아 색조 선택의 정확성을 확인하기 위한 실험을 시행하였다. 첫 번째 실험에서는 치과대학병원 전공의인 1명의 검사자가 10명의 피검자를 오전, 정오, 오후 각 3번의 측정을 통해 시간대별 자연광하에 육안, 기계 측정의 색조 선택 정확성을 분석하였다. 두 번째 실험에서는 5명의 치과대학병원 전공의와 5명의 치과대 학생, 총 10명의 검사자가 10명의 피검자를 정오에 육안, 기계 관찰을 통해 개인차에 따른 정확성을 실험하였다. 세 번째 실험에서는 두 번째 실험의 결과를 5명의 치과대학 전공의, 5명의 치과대학생 군으로 나누어 숙련도에 따른 육안, 기계 색조 선택의 정확성을 분석하였다. 실험 결과, 첫 번째 실험에서는 기계 측정 결과가 육안 측정보다 통계적으로 유의한 차이를 보이며 (P < .05) 색조 선택의 정확성을 나타내었고, 두 번째 실험에서 역시 기계 측정시 개개인의 육안 측정에 의한 색조 선택 값에 비해 재현성 및 정확성이 높았으며 통계적으로 유의한 차이를 보였다 (P < .05). 세 번째 실험에서 이전 실험의 결과를 숙련자, 비숙련자 군으로 나누어 분석한 결과 군 내 기계 측정값이 육안 관찰값보다 숙련도에 상관없이 정확도가 높으며 통계적으로 유의한 차이를 보였다 (P < .05). 하지만 군 간 육안, 기계 측정값을 비교 시 통계적으로 유의한 차이를 보이지 않아 치아 색조를 육안, 기계 측정할 때 술자의 숙련도가 큰 영향을 미치지 않음을 알 수 있었다. 따라서 기계를 이용하는 치아 색조 측정 방법이 색견본을 이용하는 시각적인 방법에 비해 더 정확하기는 하지만 어느 정도의 측색 오류를 고려해야하며 수복물 제작 시 정확한 재현과 효과적인 정보 전달을 위해 시각적인 방법과의 병행이 필요할 것으로 사료된다.