• Title/Summary/Keyword: shade guides

Search Result 16, Processing Time 0.02 seconds

Shade Matching Identification of in Vivo Natural Teeth and Porcelain-Fused-to-Metal Crowns (자연치와 도재관에 대한 색조선택의 동일성)

  • Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.29 no.1
    • /
    • pp.35-48
    • /
    • 2007
  • The purpose of this study was to evaluate shade selection using conventional visual assessment in vivo natural teeth and porcelain-fused-to-metal (PFM) crown. Maxillary central incisors, lateral incisors and canines of one hundred twenty four college women were used as vivo natural teeth. Fifty one PFM crown for maxillary central incisor fabricated by dental laboratory were used as experimental materials. Using Vitapan Classical Shade Guides, shade selection of natural teeth was measured by each college woman and shade selection of PFM crown was measured by three ceramists with more than ten years career. Both natural teeth and PFM crown shade selection were measured through Shade Eye-Ex. From the shade selection comparing, following results were obtained. The results were as follows: 1. The shade matching identification of natural teeth between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 27.4% in maxillary central incisor, 13.7% in lateral incisor and 18.5% in canine. 2. Among the shade selection of PFM crown by three ceramists, the shade evaluation of three ceramists were same only in ten cases. In twenty case, those of two ceramists were same. 3. The shade matching identification of PFM crown between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 38.6% in average. These results suggest that the shade selection using conventional visual assessment should be dealt with care in clinic and need a credible method for shade matching color.

  • PDF

A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides (광중합형 복합레진과 shade guide의 색차에 관한 연구)

  • Lim, Kyung-Min;Lee, Min-Ho;Song, Kwang-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.13-22
    • /
    • 2009
  • The composite resin, due to its esthetic quality, is considered the material of choice for restoration of anterior teeth. To get a satisfactory result in the composite resin restorations, it is necessary to choose right shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guides or shade guides that are provided by their company, but color differences among them might be expected even using the same shade in various materials. This study is to measure color differences between various light-cured composite resins and shade guides and to provide the clinicians with information which may aid in improved color match of esthetic restoration. Four kinds of light-cured composite resins (Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), Esthet X (E X)) and shade guides with A2 and A3 shade were used. Three specimens of each material and one specimen of each shade guide were made. Each composite resin was filled into the Teflon mold (1.35 mm depth, 8 mm diameter), followed by compression, polymerization and polishing with wet sandpaper. Shade guides were grinded with polishing stones and rubber points to a thickness of approximately 1.35 mm. Color characteristics were performed with a spectrophotometer(color i5, GretagMacbeth, USA). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E^*ab$) between composite resins and shade guides. CIE standard D65 was used as the light source. The results were as follows : 1. Among the $L^*$, $a^*$, $b^*$ values of most of 4 kinds of composite resin specimens which are produced by same shade, there were significant differences(p<0.05). 2. Among all 4 kinds of composite resin specimens which are produced by same shade, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 3. Between most of composite resin specimens investigated and their corresponding shade guides, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 4. In the clinical environment, it is recommended that custom shade guides be made from resin material itself for better color matching. Shade guides supplied by manufacturers or Vita Lumin shade guide may not provide clinicians a accurate standard in matching color of composite resins, and there are perceptible color differences in most of products. Therefore, it is recommended that custom shade guides be made from resin material itself and used for better color matching.

INFLUENCE OF THE SHADE GUIDE DESIGN ON COLOR HATCHING (Shade guide의 형태가 색상 결정에 미치는 영향)

  • Park, Geol;Kim, Dong-Jun;Lee, Shee-Eun;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.170-177
    • /
    • 2005
  • This study was conducted in order to assess whether the form of the shade guide affects in deciding the color of the teeth using the shade guide Eight shade light cured composite resins (Esthet-X, Dentsply, Milford, USA) were used in this study. Shade guides including the model of maxillary central incisors, teeth-form shade guide, doughnut form shade guide, and shade guide with perforated gray shield were prepared with eight shade composite resins and provided the codes randomly After arranging the models of teeth, 19 dentists working at the clinic of the Dentistry of Chonnam University Hospital and 65 students of college of dentistry, Chonnnam University selected the shade guides corresponding to the color of each tooth on the gray board under the D$_{65}$ standard illuminant. Bl shade showed highest accuracy of about 95% among all shade guides of 3 forms applied to the test and regardless of observer, tooth form shade guide showed the highest accuracy (p < 0.05) , and the doughnut form showed the lowest accuracy (p < 0.05). At the time of deciding on the color of the teeth using the shade guides as a result of above, the forms of the shade guides can affect the accuracy, and it suggests that the development of the diversified forms of shade guides, which may obtain more accurate results, is required.

COLOR DIFFERENCES BETWEEN RESIN COMPOSITES BEFORE- AND AFTER-POLYMERIZATION, AND SHADE GUIDES (복합레진의 광중합 전·후와 shade guide의 색차 비교)

  • Chon, Yi-Ju;Cho, Sung-Shik;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.299-309
    • /
    • 1999
  • The composite resin, due to its esthetic qualities, is considered the material of choice for restoration of anterior teeth. With respect to shade control, the direct-placement resin composites offer some distinct advantages over indirect restorative procedures. Visible-light-cured (VLC) composites allow dentists to match existing tooth shades or to create new shades and to evaluate them immediately at the time of restoration placement. Optimal intraoral color control can be achieved if optical changes occurring during application are minimized. An ideal VLC composite, then, would be one which is optically stable throughout the polymerization process. The shade guides of the resin composites are generally made of plastic, rather than the actual composite material, and do not accurately depict the true shade, translucency, or opacity of the resin composite after polymerization. So the numerous problems associated with these shade guides lead to varied and sometimes unpredictable results. The aim of this study was to assess the color changes of current resin composite restorative materials which occur as a result of the polymerization process and to compare the color differences between the shade guides provided with the products and the actual resin composites before- and after-polymerization. The results obtained from this investigation should provide the clinician with information which may aid in improved color match of esthetic restoration. Five light activated, resin-based materials (${\AE}$litefil, Amelogen Universal, Spectrum TPH VeridonFil-Photo, and Z100) and shade guides were used in this study. Three specimens of each material and shade combination were made. Each material was condensed inside a 1.5mm thick metal mold with 10mm diameter and pressed between glass plates. Each material was measured immediately before polymerization, and polymerized with Curing Light XL 3000 (3M Dental products, USA) visible light-activation unit for 60 seconds at each side. The specimens were then polished sequentially on wet sandpaper. Shade guides were ground with polishing stones and rubber points (Shofu) to a thickness of approximately 1.5mm. Color characteristics were performed with a spectrophotometer (CM-3500d, Minolta Co., LTD). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$ and $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E{^*}ab$) of resin composites before the polymerization process and shade guides using the post-polishing color of the composite as a control, CIE standard D65 was used as the light source. The results were as follows. 1. Each of the resin composites evaluated showed significant color changes during light-curing process. All the resin composites evaluated except all the tested shades of 2100 showed unacceptable level of color changes (${\Delta}E{^*}ab$ greater than 3.3) between pre-polymerization and post-polishing state. 2. Color differences between most of the resin composites tested and their corresponding shade guides were acceptable but those between C2 shade of ${\AE}$litefil and IE shade of Amelogen Universal and their respective shade guides exceeded what is acceptable. 3. Comparison of the mean ${\Delta}E{^*}ab$ values of materials revealed that Z100 showed the least overall color change between pre-polymerization and post-polishing state followed by ${\AE}$litefil, VeridonFil-Photo, Spectrum TPH, and Amelogen Universal in the order of increasing change and Amelogen Universal. Spectrum TPH, 2100, VeridonFil-Photo and ${\AE}$litefil for the color differences between actual resin and shade guide. 4. In the clinical environment, the shade guide is the better choice than the shade of the actual resin before polymerization when matching colors. But, it is recommended that custom shade guides be made from resin material itself for better color matching.

  • PDF

COLORIMETRIC ANALYSIS OF EXTRACTED HUMAN TEETH AND FIVE SHADE GUIDES (발거된 자연치와 5종 Shade Guide의 색채 계측기를 이용한 색상 비교)

  • Hwang, In-Nam;Oh, Won-Man
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.769-781
    • /
    • 1997
  • The tristimulus values of 180 extracted maxillary and mandibular anterior teeth were measured by colorimeter. And it were colnverted to Munsell color order system(Hue, Value, Chroma) and CIE $L^*a^*b^*$ color coordinates. The commonly used Vita, and Bioform shade guides, 2 composite resin shade guides(Prisma APH and Z-100), and a glass-ionomer shade guide(Fuji II) were compared with these teeth. At the middle facial surface, color distributions of teeth were Hue(0.56YR to 9.77Y), Value(2.46 to 7.9), and Chroma(0.14 to 2.02). And the aberaged values and standard deviations for $L^*a^*b^*$ were $63.18{\pm}10.44$, $1.11{\pm}1.66$, and $5.79{\pm}2.36$. The shade guide did not match well with the color space of the human teeth. Especially, the lacks of the Yellow-red Hues and higher values were prominent. Compare with other measurements, the Hues of the teeth measured in this study were broadly distributed(most of ranges in Y and YR were included), while the Value and chroma were shown to the lower.

  • PDF

Evaluation of shade guide using digital shade analysis system (색조 선택 시스템을 이용한 shade guide의 색조 분석)

  • Lee, Seung-Taek;Lee, Jong-Hyuk;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.1-11
    • /
    • 2009
  • Statement of problem: There are two methods of color choice for the esthetic restoration. One is visual shade matching which draws a comparison between shade guide and teeth in dentist's own eye and the other is using a digital shade analysis system recently introduced. Although the visual shade matching has a lot of problems, decision of color by this visual shade matching and the ways of expression for the decided color are still applicable to clinical dentistry. Purpose: This study is designed to investigate shade guides used in the dental clinics and laboratories have the same value using ShadeEye-$NCC^{(R)}$ dental chroma meter (Shofu Inc., Kyoto, Japan) using shade guide are evaluated. Material and methods: At the first experiment, eight Vita Lumin Vacuum shade guides (Vident Inc., California, USA) were collected from the dental clinics. A1 and B1 shade tabs are chosen and the colors are analyzed five times each in both tooth and porcelain modes by digital shade analysis system, ShadeEye-$NCC^{(R)}$. In the second experiment, twelve Vita shade guides using practically in the dental clinics and laboratories were collected and also A1 and B1 shade tabs are chosen and the colors of A1 and B1 are analyzed one time each in both tooth and porcelain modes by ShadeEye-$NCC^{(R)}$. Results and conclusion: There were significant differences among eight shade guides in terms of shade (chroma), value and hue in both of A1 and B1 (P<.05). Shade guides using in present both dental clinics and laboratories did not show significant differences, except A1 in the porcelain mode, it showed significant differences (P<.05) in the shade even though the shade tab has the same name.

ANALYSIS OF OPTICAL TRANSMISSION CHARATERISTICS BY VISIBLE LIGHT INTO SHADE GHIDES (가시광선영역에서 shade guide에 따른 광투과도 특성 연구)

  • Choi, Keun-Bae;Park, Charn-Woon;Song, Chang-Yong;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.147-159
    • /
    • 2000
  • The purpose of this study was the evaluation of spectral transmission of the commercial three shade guides and the relationship of hue, value, and chroma according to the transmission rate. The spectral transmittance of three shade guides - Vita Lumin Shade Guide, Vintage and Unibond Shade Guide, and Vitapan 3D-Master Shade Guide - were measured. For direct transmission measurements, each shade tabs were placed at the entrance port of the 1mm diameter intergrating sphere. The intensity of the light source passing through the shade tabs to the right angle was continuously recorded for wavelength from 400 to 700 nm. A transmission spectrum and digital data were obtained for each measurement and they were evaluated using Microcal Origin program. The obtained results of this study were as follows : 1. In Vita Lumin Shade Guide, sum of the transmission rate of the shade tabs at the wavelength 400-700nm was decreased in agreement with the arrangement order at each A, B, C, D group, except D4 shade tab. However, there were no relationships between the transmission rate of the shade tabs and the value-oriented. 2. In Vintage and Unibond Shade Guide, sum of the total transmission rate of the shade tabs was decreased in agreement with the arrangement order at each A, B, C, B group. When all shade tabs arranged in value-oriented, transmission rate was accord with the order, except D4 shade tab. 3. When shade tabs of the Vitapan 3D-Master Shade Guide have the same value and hue, sum of their total transmission rate decreased in accordance with the chroma-oriented. When the shade tabs have the same value and chroma, there were no differences from the order of the transmission rate to the various hue type. However, in the 'R' tabs of reddish hue type, the transmission rate increased at the long wavelength range area. In conclusion, we need the quantitative analyzing instruments in transmission determination. Vitapan 3D-Master Shade Guide covers the tooth color space taking into account the parameters of the systematic value, chroma, hue oriented, and the transmission rate relatively accorded with that sequence.

  • PDF

Effects of eye dominance on shade matching and color perception among the dentist population

  • Pattnaik Kalyani;Kannan Subiksha;Amit Jena;Govind Shashirekha;Saumyakanta Mohanty;Gaurav Sharma
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.4
    • /
    • pp.40.1-40.8
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the influence of eye dominance on color perception, and shade matching. Materials and Methods: A total of 104 participants were selected for the study. There were 3 groups: Group I: 3rd and 4th year dental students and interns (n = 40); Group II: postgraduates (n = 34); Group III: senior residents and faculty members (≥ 6 years of clinical experience) (n = 30). All participants were evaluated for congenital color blindness with Ishihara plates, their dominant eye with Mile's test, and their color perception with the Farnsworth-Munsell 100 hue test. The shade guide test was used for shade matching with a second corresponding set of Vitapan classical shade guides. Results: The results of Mile's test revealed that 60.6% were right-eye dominant and 39.4% were left-eye dominant. There was a statistically significant difference among all participants between the dominant eye and the non-dominant eye in shade matching. Conclusions: The dominant eye has a positive effect on shade matching and the ability to match shades becomes better with an increase in clinical experience.

A Study on Color Differences Between Composite Resins and Shade Guides (복합레진과 shade guide의 색차에 관한 연구)

  • Kim, Hee-Sun;Um, Chung-Moon;Kahng, Myong-Whai
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.107-120
    • /
    • 1996
  • 복합레진은 조작이 용이하고 강도가 우수하며 중합시간이 짧고 법랑질과 상아질에 접착이 가능하며 연마성이 뛰어나고 자연스러운 색상을 나타내므로 심미적 수복에 가장 일반적으로 선택되는 재료의 하나이다. 대부분의 복합레진 kit에는 shade guide가 포함되어 있어 이를 기준으로 중합된 후의 복합레진 색조를 예상하여 선택하게 된다. 그러나 이러한 shade guide들은 대개 복합레진이 아닌 plastic으로 제조된 것으로 중합된 복합레진의 실제 색조와는 차이가 생기게 되며 결국 shade guide 자체의 문제점으로 인해 이상적인 색조선택이 어려워진다. 이에 본 연구에서는 국내에 시판되고 있는 5종의 복합레진 제품을 선정하여 분광 광도계를 이용해서 shade guide와 중합된 복합레진 사이의 색조차이를 측정, 비교 연구하였다. 직경 16mm. 두께 1.6mm의 plastic mold에 5종의 광중합형 복합레진(Z100, Prisma TPH, Tetric, Silux Plus, Herculite XR)을 충전하고 응축기에 넣어 압축한 후 제조사의 지시에 따라 광중합기로 중합시킨 후 mold에서 시편을 제거하여 보관했다가 젖은 sandpaper 상에서 순차적으로 연마하였다. shade guide는 step부분을 갈아내어 복합레진 시편과 동일한 두께로 만든후 연마하였다. 분광광도계에 shade guide를 넣고 CIE illuminant D65 하에서 spectral reflectance를 측정하고 해당 색조의 복합레진 시편도 통일한 방법으로 측정하고 $L^*$, $a^*$, $b^*$값과 ${\Delta}E^*$값을 얻은후 분석하여 다음과 같은 결과를 얻었다. 1. Z100의 D3, A3, B2 shade와 Prisma TPH의 B2 shade를 제외한 모든 시편에서 shade guide와 복합레진간에 육안으로 인지할 수 있는 색차(${\Delta}E^*$ > 1.0)가 관찰되었다. 2. 평균적으로 Z100이 가장 적은 색차를 나타내었고 Prisma TPH, Tetric, Silux Plus, Herculite XR 순으로 색차가 증가하였다. 3. Prisma TPH의 A2 shade. Tetric의 W shade. Silux Plus의 YB, U shade, Herculite XR의 L, LY shade는 ${\Delta}E^*$값이 3.3 이상으로 나타났다. 4. Z100, Prisma TPH, Tetric, Silux Plus에서는 복합레진보다 shade guide가 더 높은 $L^*$값을 보이는 경향이 나타났으며, Herculite XR에서만 복합레진이 더 높은 $L^*$값을 나타냈다. 5. 모든 시편에서 $b^*$ 값은 (+)로 관찰되었고, Z100, Prisma TPH, Tetric, Silux Plus의 shade guide는 복합레진에 비해 높은 $b^*$값을 보였다. 6. 모든 시편에서 $a^*$값은 (-)로 관찰되었고. Herculite XR 및 Silux Plus에서는 복합레진이 shade guide 에 비 해 낮은 $a^*$값을 나타냈다.

  • PDF

Shade comparative analysis of natural tooth measured by visual and spectrophotometric methods (육안과 분광 측정기를 이용한 자연 치아의 색조비교분석)

  • Kim, Bum-Suk;Shin, Soo-Yeon;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.443-454
    • /
    • 2008
  • Statement of problem: A clinically successful color match is one of the important factor to get an esthetic dental restoration. Dental shade guides are commonly used to evaluate tooth color in restorative procedure. But numerous reports have indicated that common shade guides do not provide sufficient spectral coverage of the natural tooth colors. To address issues associated with the shade guide, distinct avenues have been pursued objective spectrophotometric / colorimetric assessment. Purpose: This study compared the accuracy of tooth color selection of spectrophotometer with that of human visual determination. Three main factors were investigated, namely, the effect of light, the individual variation and the experience of the observer. Material and methods: At the first experiment, on ten patients, one operator independently selected the best matching shade to the unrestored maxillary central incisor, using a Vita Classical Shade Guide in the morning, at noon and in the afternoon. The same teeth were measured by means of a reflectance spectrophotometer. At the second experiment, on ten patients, ten operators (5 experts, 5 novices) selected and measured by the same method above at noon. At the third experiment, the results of the second experiment were divided into two groups, expert and novice, and analyzed. Results: 1. There was significant difference between visual and spectrophotometric assessment (mean ${\Delta}E$ values) in experiment 1, 2, 3 (P < .05). 2. There was no significant difference between experts and novices group, when comparing with each visual and spectrophotometric assessment (mean ${\Delta}E$ values). Conclusion: Spectrophotometer could be used to analyze the shade of natural tooth objectively. Thereby, this method offers the potential tominimize considerably the need for corrections or even remakesafter intraoral try-in of restoration. Furthermore, to achieve its advantage, both the shade-matching environment and communication between dentist and technician should be optimized with use of visual and instrumental shade-matching systems.