• 제목/요약/키워드: sewage treatment system

검색결과 369건 처리시간 0.025초

수질오염총량관리 합류식지역의 우기시 관거이송 변화유형 (Patterns on Sewer Transfer Flow for Rain Weather Period in the Area with Combined Sewer System for the Management of TMDLs)

  • 박준대;오승영;김지태
    • 한국물환경학회지
    • /
    • 제26권6호
    • /
    • pp.1008-1015
    • /
    • 2010
  • Discharged pollution load is varied as rainfall changes in the area with combined sewer system. Changes in discharged pollution load are directly related with those of sewer transfer flow. Therefore, it is important to identify the pattern of sewer transfer flow for the analysis of changes in discharged pollution load. This study reviewed the type of distribution of sewer transfer flow for 17 sewage treatment plants and developed simple formular to estimate sewer transfer flow as rainfall changes. 11 facilities showed to have some relation with rainfall in the change of sewer transfer flow but 6 facilities to have no relation. Relationships between rainfall amount and sewer transfer flow showed that 6 facilities out of 11 had relatively strong relationships above R2=0.5, which were considered to be affected directly by rainfall changes. The formular which explain the relationship between rainfall and sewer transfer flow can be applied in the analysis of rainfall effects on discharged pollution load, therefore, the more appropriate evaluation will be done.

시스템다이내믹스를 활용한 도시개발밀도의 적정성 평가 모델 구축 연구 (Establishment of the Measurement Model about the Adequate Urban Development Density using System Dynamics)

  • 전유신;문태훈
    • 한국시스템다이내믹스연구
    • /
    • 제4권2호
    • /
    • pp.71-94
    • /
    • 2003
  • The purpose of this dissertation is to build a development density control model and estimate optimum developmental density level for a sustainable urban growth management. To develop the model, system dynamics modeling approach was used. The model was developed to analyze how urban growth, transition, and decay occur depending on the interaction among population, houses, industry structure, land and urban infrastructure such as road, water supply, and sewage treatment facilities. The model was applied to Anyang city to estimate optimum density level. Extensive computer simulation was conducted to find out the maximum numbers of population, industry structure, houses, and cars that can be adequately sustained with the current Anyang city's infrastructure capacity. The computer simulation result shows that the city is overpopulated by some 90,000 people. It nab analyzed that 20% increase of existing capacity of urban infrastructure is necessary to support current population of Anyang city. To reduce the population to the adequate level whereby the current urban infrastructure can sustain, the current city regulation on floor area ratio needs be strengthened at least 20% to 35%.

  • PDF

Development and Performance Evaluation of Electrodewatering System for Sewage Sludge Recycling

  • Lee, Jae-Keun;Lee, Jung-Eun;Shin, Hee-Soo;Park, Chan-Jung;Lee, Chang-Gun;Kim, Young-Hwan;Kim, Man-Jong
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.443-447
    • /
    • 2001
  • A laboratory-scale electrodewatering system for enhancing conventional filter pressure dewatering by an electric field has been developed to decrease the water content of sludge generated in the wastewater treatment. It consists of a piston-typed filter press, a power supply and data acquisition system. The offset of electrodewatering is investigated as a function of applied pressure, applied voltage, sludge type and filtration time. Also the optimal conditions for maximizing the dewatering efficiency in the eletrodewatering system are investigated. Electric field strength and mechanical pressure are in the range of from 0 to 120 V/cm and from 98.1 to 392.4 kPa. The dewatering rates increased with increasing electric strength. These experiments produced a final sludge cake with water content of 60 wt% using electrodewatering technology, compared with a 80 wt% using pressure filtration alone. The conventional filtration system using the electrodewatering shows the potential to be effective method for improving dewatering Sludge.

  • PDF

습지-연못 연계시스템에 의한 수질개선과 농업적 재이용 타당성 분석 (Feasibility Study of Wetland-pond Systems for Water Quality Improvement and Agricultural Reuse)

  • 장재호;정광욱;함종화;윤춘경
    • 생태와환경
    • /
    • 제37권3호통권108호
    • /
    • pp.344-354
    • /
    • 2004
  • 본 연구에서는 용수재이용을 위해 생활하수를 지하흐름형 인공습지로 처리한 후 연못시스템에 연결시켜 미생물과 각 수질인자들의 처리효과를 분석하였으며, 그 결과를 요약하면 다음과 같다. SS의 농도는 얼음이 녹은 3월 초순에서 4월 초순까지는 10 mg $L^{-1}$ 이하의 매우 낮은 농도로 우리 나라 방류수 수질기준보다 낮은 농도를 유지할 수 있었으나 겨울이나 여름 특정기간에 농도가 높아서, 용수 재이용시 보건 ${\cdot}$ 위생적인 측면과 더불어 이용자에게 심미적인 불편함이 없어야 하므로 유출부에 여과시설 등 관리대책을 검토할 필요가 있을 것으로 생각된다. $BOD_5$는 식물의 생장과 미생물의 성장이 저조한 동절기의 농도 증가현상과 이들의 활동이 활발한 성장기의 감소현상을 뚜렷히 나타내었으나, 전체적으로는 국제적인 농업용수 재이용 수질기준보다 낮은 수준으로서 우려할 사항이 아닐 것으로 판단된다. 영양물질의 경우 DO가 상승한 호기성상태에서 T-N, T-P 농도가 감소하는 것을 확인할 수 있었다. 수질개선을 목적으로 연못시스템을 이용할 경우 3월중에 상층부를 유출시키고 3월 이후에는 수심을 낮게 유지하여 심수층까지 호기성상태를 유지하는 것이 수질관리에 유리할 것으로 판단된다. 지하흐름형 인공습지에서의 미생물 처리효율은 TC, FC, E. coli 모두 평균 92 ${\sim}$ 96% 이상 높은 처리 효율을 보였으며, 인공습지 유출수가 연못시스템을 거치면서 추가로 평글 83 ${\sim}$ 90% 이상 제거되어 평균 대장균농도가 1,200MPN 100 $mL^{-1}$ 로써 인공습지와 연못시스템을 연계 ${\cdot}$ 적용한 후 농업용수로 재이용하거나 수계로 방류할경우 보건 ${\cdot}$ 위생상의 문제를 크게 줄일 수 있을 것으로 판단된다. 미생물의 소독은 대부분 태양광에 의해서 이루어지기 때문에 본 연구와 같이 연못 상층부에서 유출시킬 경우 높은 처리효율을 기대할 수 있을 것으로 생각하며, 대장균과 연못 내에 존재하는 생물들 사이의 상호작용을 정확히 이해하여 적절한 관리대책을 마련 할 경우 안정적인 방류수 농도를 확보할 수 있을 것으로 판단된다. 자연정화로서 하수처리수를 고도 처리할 수 있는 인공습지와 연못시스템을 연계처리 하면 높은 미생물 소독효율을 나타내어 보건 ${\cdot}$ 위생상의 문제를 크게 줄일 수 있을 것으로 기대된다. 인공습지와 연계한 연못시스템의 하수처리방식은 간단한 구조, 큰 완충능력, 적은 슬러지 발생, 간소한 유지 ${\cdot}$ 관리의 장점을 가지고 있어서, 소규모하수처리와 농업용수 재이용 기술로서 적용가능성이 클것으로 판단된다.

하천수 정화를 위한 시화인공습지의 초기 수질 정화능 (Early-Year Performance of the Sihwa Constructed Wetland for Stream Water Treatment)

  • 권순국;이경도;조영현;김성배;전기설
    • 한국농공학회논문집
    • /
    • 제47권1호
    • /
    • pp.93-102
    • /
    • 2005
  • A prototype surface flow constructed wetland was built in the upstream area of Sihwa reclaimed tidal lands to improve the water quality of Lake Sihwa by treating severely polluted stream water. In this study, we monitored hydrology, macrophyte (Phragmites communis Trin,) growth, and water quality in the Banwol and Donghwa wetlands to evaluate their performance during the initial period after the completion of wetland construction, The average removal efficiency($\%$) in each wetland was relatively low compared with the performance data from the North America Wetland Treatment System Database (NADB), which mainly includes urban sewage-treatment wetlands. However, the average removal rates per unit area ($g/m^{2}/day$) were 0.72, 0.72 and 0.51 (BOD), 2,04, 2.46 and 0.70 (SS), 0.89, 0.43 and 1.09 (TN) and 0.02, 0.02 and 0.02 (TP) in the Banwol and Donghwa wetlands and NADB, respectively. The overall performance of the Banwol and Donghwa wetlands was within the expected range of the wetland system processes contributing the reduction of the pollutant load to Lake Sihwa during the initial period of wetland operation. Considering the low influent concentration, high hydraulic loading rate, and insufficient macrophyte growth since the wetland was constructed, better performance is expected if an improved operational scheme is adopted.

Entrapped Mixed Microbial Cell (EMMC) 공정을 이용한 수산물 가공 폐수처리에서 유기물 및 질소 동시제거 (Simultaneous Removal of Organic and Nitrogen in the Treatment of Fish Processing Wastewater using Entrapped Mixed Microbial Cell (EMMC) Process)

  • 정병철;박권삼;정병곤
    • 한국물환경학회지
    • /
    • 제22권3호
    • /
    • pp.492-497
    • /
    • 2006
  • Feasibility of simultaneous removal of organic materials and nitrogen in the wastewater from fisheries processing plant was evaluated using entrapped mixed microbial cell (EMMC) process. The experiment was performed using activated sludge from municipal sewage treatment plant which was immobilized with gel matrix by cellulose triacetate. It was found the stable operation at the treatment system which is composed of anoxic and oxic tank, was possible when the organic and nitrogen loading rates were increased stepwise. The organic and nitrogen loading rates were conducted from 0.65 to $1.72kgCOD/m^3/d$ and from 0.119 to $0.317kg\;T-N/m^3/d$ with four steps, respectively. The maximum nitrogen loading rate which could satisfy the regulated effluent standard of nitrogen concentration, was $0.3kg\;T-N/m^3/d$. The removal efficiency of total nitrogen was decreased apparently as increasing nitrogen loading rates, whereas the removal efficiency of ammonium nitrogen was effective at the all tested nitrogen loading rates. Therefore, it was concluded that nitrification was efficient at the system. Nitrate was removed efficiently at the anoxic tank. whereas the nitrification efficiency at the oxic tank ranged 94.0% to 96.9% at the tested loading rates. The removal efficiencies of chemical oxygen demand (COD) and those of total nitrogen at the entire system ranged from 94.2% to 96.6% and 73.4% to 83.4%, respectively.

뉴로-퍼지 알고리즘을 이용한 슬러지 농도 추정 기법 개발 (Development of Sludge Concentration Estimation Method using Neuro-Fuzzy Algorithm)

  • 장상복;이호현;이대종;권진희;전명근
    • 한국지능시스템학회논문지
    • /
    • 제25권2호
    • /
    • pp.119-125
    • /
    • 2015
  • 정수장, 하수처리장, 폐수처리장의 배출수 처리공정에서 고 농도의 슬러지 선별, 이송 및 약품 투입량 조절을 위한 기준으로 슬러지 농도계가 사용되고 있다. 그러나 슬러지에 함유된 이물질이 혼입될 경우 감쇄량이 증가하거나 초음파가 수신부에 전달되지 않아 실제 농도값 보다 높은 값을 출력하거나 헌팅현상이 발생한다. 또한 단일 센서에 슬러지 포착 또는 고장 등의 문제로 배출수 공정 자동화에 어려움이 많았다. 이러한 문제점을 개선하기 위해 초음파 다중빔 농도계를 개발하여 사용하고 있으나 특정 초음파 빔의 농도 측정값에 오류가 발생할 경우 전체 농도시스템의 성능이 떨어지는 단점이 있다. 따라서 본 논문에서는 초음파 다중빔 농도계 간의 신뢰성을 판단하고, 신뢰성이 높은 다중빔 농도계만을 사용하여 슬러지 농도 예측값의 성능 향상방안을 제시하였다. 예측 알고리즘으로는 뉴로-퍼지모델을 적용하였으며 다양한 실험을 통하여 제안된 방법의 타당성을 검증하였다.

아두이노와 초음파 센서를 이용한 실험용 수위 측정 장치 개발 (Development of experimental water level measuring device using an Arduino and an ultrasonic sensor)

  • 유문성
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권4호
    • /
    • pp.143-147
    • /
    • 2018
  • 수위는 하수장, 정수장, 하천, 댐, 공장의 저장탱크 등 다양한 분야에서 측정된다. 수위측정을 위한 초음파 기기가 판매중이나 산업용으로 실험에서 사용하기는 가격이 너무 비싸다. 전자 기술의 급속한 진보로 인해 다양한 종류의 측정, 모니터링 및 제어 기능이 저렴하게 구축하는 것이 가능해졌다. 저렴한 가격으로 초음파 수위 측정시스템을 만들기 위하여 본 연구가 시작되었다. 실험용으로 사용하기 위하여 아두이노, 초음파 센서 및 온도 센서로 시스템을 구성하였다. 초음파 센서는 센서에서 수위 표면까지의 시간을 측정한다. 온도 센서는 대기 온도를 측정하며 온도 변화로 인한 소리의 속도를 보정하여 초음파 거리 측정의 정확성을 높인다. 아두이노는 측정 전반을 관리하고 수위를 계산한다. 시스템의 모든 구성 요소는 장치거치대에 조립되었다. 제안된 시스템을 가지고 실험한 결과 수위가 실측치와 매우 가까웠다. 이 시스템은 또한 저렴하며 설치 및 유지하기가 쉬워 실험용으로 적절하다.

중온 배기열을 이용한 유기랭킨사이클 작동유체별 성능특성 (Performance Characteristics of Organic Rankine Cycle Using Medium Temperature Waste Heat with Different Working Fluids)

  • 권동욱;허기무;윤성훈;문윤재;유호선;이재헌
    • 플랜트 저널
    • /
    • 제10권2호
    • /
    • pp.38-47
    • /
    • 2014
  • 2012년부터 신재생에너지 의무공급제도가 국내에 도입되고, 전 세계적인 에너지 절약과 환경보존 측면에서 미활용 및 신재생에너지원에 대한 관심이 날로 증가하고 있다. 특히, 중저온 열원의 활용방안에 대하여 많은 관심과 연구가 활발하게 진행되면서 고부가가치의 전력생산이 가능한 유기랭킨사이클이 그 대안으로 떠오르고 있다. 따라서 본 연구에서는 유기랭킨사이클 발전시스템을 하수 처리장 1,500 kW 바이오가스엔진 배기열을 열원으로 하부 사이클을 구성하여 성능해석 상용 프로그램으로 성능특성을 예측하였다. 바이오가스엔진 배열의 실제 운전조건은 $460^{\circ}C$의 온도와 매 초당 2.7 kg의 유량으로 운전되고 있었다. 이러한 열원 온도에 적합한 작동유체를 다수 선정하여 작동유체 종류별 성능해석을 수행하였으며, 최고의 성능이 나타나는 이소펜탄의 경우 163.1 kW의 발전출력과 13.66%의 효율을 얻을 수 있었다.

  • PDF

낙동강 수계에서의 X-선 조영제(Iopromide)의 분포 특성 (Occurrence of X-ray Contrast Media (Iopromide) in the Nakdong River Basin)

  • 염훈식;손희종;류동춘;장성호
    • 한국환경과학회지
    • /
    • 제21권9호
    • /
    • pp.1131-1138
    • /
    • 2012
  • The aims of this study were to investigate and confirm the occurrence and distribution patterns of iodinated X-ray contrast media (iopromide) in Nakdong river basin (mainstream and its tributaries). Iopromide was detected in 16 sampling sites. The concentration levels of iopromide on February 2011 and on October 2011 in surface water samples ranged from not detected (ND) to 1481.1 ng/L and ND to 1168.2 ng/L, respectively. The highest concentration level of iopromide in the mainstream and tributaries in Nakdong river were Goryeong and Jincheon-cheon, respectively. The sewage treatment plants (STPs) along the river affect the iopromide levels in river and the iopromide levels decreased with downstream because of dilution effects.