• 제목/요약/키워드: sewage treatment facilities

검색결과 164건 처리시간 0.02초

Emergy를 이용한 오염물질 저감시설의 환경 비용/편익 분석 (Environmental Cost and Benefit Analysis Pollutant Reduction Facilities of the using the Emergy)

  • 김진이;황하선;김상수;이재관
    • 한국물환경학회지
    • /
    • 제29권5호
    • /
    • pp.591-597
    • /
    • 2013
  • The input emergy of an advanced treatment plant for reducing the 1 kg of TN and TP was estimated 4.14E+14 sej/kg, 5.02E+15 sej/kg, respectively. In addition, the input emergy of constructed wetland for reduction of the 1 kg of TN and TP reduction was estimated to be 2.48E+14 sej/kg, 3.38E+15 sej/kg, respectively. The cost reducing 1 kg of TN and TP for an advanced treatment plant was estimated 197,466 won and 2,388,739 won respectively and constructed wetland was estimated 117,976 won and 1,609,213 won respectively. As a result, All of the emergy source of constructed wetland for reducing non-point source is renewable resource. If we use the constructed wetland, it results in enhancing economic value by reducing of non-point pollution, controlling a flood and providing the habitat of animals or plants. Improving water quality program in the Nakdong River Basin should be changed into an ecological treatment facilities from expansion of the sewage treatment facilities and advanced treatment plant using high cost and non-renewable energies.

하수재이용시설 농축수가 하수처리장 생물반응조 운영에 미치는 영향 (Effects of Membrane Filtration Concentrate of Sewage Reuse Facility on Performance of Bioreactor in Sewage Treatment Facility)

  • 임지영;김현식;배민수;김진한
    • 유기물자원화
    • /
    • 제26권3호
    • /
    • pp.5-14
    • /
    • 2018
  • 하수재이용시설 막여과 농축수가 하수처리장 생물반응조 미생물에 미치는 영향을 알아보기 위하여 기 운영 중인 하수재이용시설 농축수를 채취 분석하고 농축수 주입에 따른 산소섭취율 변화 및 연속식 활성슬러지 실험을 수행하였다. 기 운영 중인 하수재이용시설 농축수를 분석한 결과 농축수의 유기물과 T-P 농도는 SS 농도와 밀접한 관계가 있고 농축수 내의 이온성 물질은 $Cl^-$ > $Na^+$ > $Ca^{2+}$ > $K^+$ > $Mg^{2+}$ > $F^-$순으로 높게 나타났으며 농축수의 항목별 분석값은 농축수 채취시기에 따라 크게 변함을 알 수 있었다. 농축수 비율에 따른 미생물 산소섭취율(OUR) 실험을 실시한 결과 농축수 비율이 증가함에 따라 농축수가 활성슬러지 미생물에 유기물로 작용하여 산소섭취율이 증가함을 알 수 있었으며 OUR 실험만으로는 독성영향을 주는 농축수 비율을 산정할 수 없었다. 연속 활성슬러지 실험을 실시한 결과 농축수 주입비율이 증가함에 따라 MLSS 농도, 유기물 제거효율 그리고 T-N 제거효율은 서서히 감소하였다. 따라서, 실험결과 농축수가 활성슬러지의 처리효율에 영향을 주기 시작하는 주입비율은 25% 이상인 것으로 판단된다.

도시 물 문제 저감을 위한 회복탄력적 사회기반시설 구축: 2. 수질오염 문제 구조적 대안의 내구성 평가 (Establishment of Resilient Infrastructures for the Mitigation of an Urban Water Problem: 2. Robustness Assessment of Structural Alternatives for the Problems of Water Pollution)

  • 정지현;이창민;안진성;김재영;최용주
    • Ecology and Resilient Infrastructure
    • /
    • 제3권3호
    • /
    • pp.182-188
    • /
    • 2016
  • 본 연구는 도시 홍수문제의 구조적 해결방안을 도출하기 위하여 내구성-비용지수 (robustness cost index, RCI)를 수질오염 문제 사례에 재해석 및 적용하였다. 처리기준 산정방식이 다른 하수 처리수 내 내생호르몬 오염과 취수원 원생동물 번성을 대표 사례로 선정하여 기존시설과 대안시설 (구조적 대안)의 내구성 지수 (RI) 값이 1 이상인 경우를 내구성을 확보한 대안으로 판정하고 내구성 지수와 비용지수 (CI)를 결합한 RCI 값을 산정하였다. 하수 처리수 내 내생호르몬 오염은 인체로부터 기인하는 $17{\beta}$-estradiol 을 대상 오염물질로 하여 현재 하수처리시설과 대안시설 (고도처리공정 증축)을 비교하였고, 고도처리공정을 증축한 사례에서 RI뿐만 아니라 RCI 값이 큰 결과가 나타났다. 취수원 원생동물 번성의 경우 크립토스포리디움을 처리하기 위한 소독방안으로 자외선 소독과 오존 소독을 대상으로 RCI를 산정하였고 오존 소독시설이 RCI값이 더 높은 것을 확인하였다. 처리기준이 다른 수질오염사례의 RCI 산정과정과 도출한 값을 바탕으로 재해 발생 시 피해 복구와 피해 방지를 위한 구조적 대안 수립과정의 방향을 제시하고 그 구축전략을 제안하였다.

경상북도내 주요 하폐수처리장 방류수의 미량유해물질 배출특성 (The Discharge Characteristic of Micropollutants in Effluents from Major Sewage and Wastewater Treatment Facilities in GyeongSangBukdo)

  • 서상욱;배헌균
    • 한국환경과학회지
    • /
    • 제20권6호
    • /
    • pp.673-678
    • /
    • 2011
  • Water samples from several wastewater treatment plants and two industry drains in Gyeongsangbukdo were investigated for concentration levels of micropollutants. Samples were taken totally four times from May to November of 2008 and tested for seven factors including pesticide, 1,4-Dioxane and Perchlorate which had been big issues for Nakdong river because of their contaminations. As results, 2,4-D, Alachlor, and BEHA were not detected while BEHP was detected at some sampling sites. 1,4-Dioxane and Perchlorate were also detected in wide ranges from several sampling sites. Therefore, continuous supervising and monitoring systems needed to be invested for proper management for micropollutants since those micropollutants could affect human health and aquatic system with low concentration levels.

환경시설물 대상 홍수취약성 평가지표 개발에 관한 연구 - 하수처리장을 중심으로 - (A Study on Development of Flood Vulnerability Evaluation Indicators for Sewage Treatment Plant)

  • 노재덕;한지희;이창희
    • 융합정보논문지
    • /
    • 제10권12호
    • /
    • pp.110-118
    • /
    • 2020
  • 본 연구에서는 환경시설을 대상으로 침수피해에 대비한 재해 예방능력을 강화하고자 정량적인 부분뿐만 아니라 정성적인 부분을 고려한 홍수취약성 평가지표를 개발하고자 하였다. 이를 위해 환경시설의 침수에 취약한 시설물을 분석하고 구조적, 비구조적인 평가지표로 구분하여 개발하였다. 구조적 평가지표는 환경시설에 취약한 측면을 시설의 유형적인 측면에 대해 11개의 평가지표를 제시하였으며, 비구조적 평가지표는 내부인자와 외부인자로 구분하여 시설의 운영·상태 등 무형적인 측면에 대해 내부인자 8개와 외부인자 6개로 제시하였다. 본 연구에서 제시한 홍수취약성 평가지표는 기존 환경시설물의 침수피해 대비 홍수취약성에 대해 평가할 수 있도록 함으로써 홍수에 대한 대비할 수 있을 것으로 기대된다.

대구시 산업단지 환경기초시설의 악취발생 특성 (Emission Characteristics of Odor Compounds from Fundamental Environmental Facilities in an Industrial Complex Area in Daegu City)

  • 이찬형;전현숙;신명철;김은덕;장윤재;권병윤;송희봉
    • 한국환경보건학회지
    • /
    • 제42권4호
    • /
    • pp.246-254
    • /
    • 2016
  • Objectives: This study evaluated the odor emission characteristics from fundamental environmental facilities at an industrial complex area in Daegu City. Methods: The odor samples were collected from May 2015 to January 2016 and were analyzed for specified offensive odor substances. The odor quotient and the odor contribution was calculated. Results: Ammonia was detected in all samples monitoring specified odor compounds, followed by hydrogen sulfide and acetaldehyde. According to contribution analysis, hydrogen sulfide shows the highest contribution in all facilities. At wastewater treatment plants A and B and sewage treatment plant F, it was followed by acetaldehyde. At wastewater treatment plant C, it was followed by imethyl sulfide. Conclusion: The major component of odor can be determined by evaluating the degree of contribution to the odor intensity rather than the concentration of the individual odor components. To increase the effectiveness of odor reduction, policies focused on materials with a high odor contribution are needed rather than focusing on high-concentration odor compounds.

수처리공정의 디지털 트윈 요소기술과 추진 전략 (Element Technology and Strategy of Digital Twin in the Water Treatment)

  • 조영만;정용준
    • 한국습지학회지
    • /
    • 제25권4호
    • /
    • pp.284-290
    • /
    • 2023
  • 국내 상하수도 시설들은 운전과 관리 인력의 노후화와 같은 유지관리의 어려움이 가속화되고 있으므로 디지털트윈 기술이 유력한 관리 기술로 부각되고 있다. 국내 정수장의 디지털트윈 기술은 환경부의 지능형 하수처리, 일부 지자체에서 독자적으로 진행되는 사업 및 K-water 주관의 디지털 트윈 과제 등이 포함되지만, 적용 범위가 각 기관별로 상이하다. 이에 따라 정수공정에서는 시행착오를 줄이고, 미래 사업 활성화를 위해서는 기술표준화와 순차적 도입과정이 필요하다. 본 연구의 목적은 환경부 스마트하수처리사업, K-water 지능형정수공정 구현사업, 지자체 사업 등 각 기관별로 추진되고 있는 디지털트윈 관련 기술에 대한 효율적인 추진 전략을 제공하는데 있다.

수처리시설용 콘크리트의 금속용사 피막 종류에 따른 내오존성 및 전기화학적 방식 성능 평가 (Evaluation of Ozone Resistance and Anti-Corrosion Performance of Water Treatment Concrete according to Types of Metal Spray Coating)

  • 박진호;최현준;이한승;김상열;장현오
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권4호
    • /
    • pp.61-68
    • /
    • 2019
  • 산업화, 도시화로 인해 수자원의 오염이 악화 되면서 기존에 염소를 이용한 정수처리 방법으로는 깨끗한 물을 공급하는데 어려운 실정이다. 이에 오존을 이용한 고도정수 처리 시설의 도입이 증가하고 있다. 그러나 기존의 방수 방식 공법으로 사용되는 에폭시계 방수 방식제 및 스테인리스는 오존의 강력한 산화력으로 인해 열화되어 박리 등 문제 발생하였으며, 콘크리트까지 영향을 미쳐 내구성 저하의 원인이 된다. 이에 따라 본 연구에서는 내오존성 및 내화학성이 뛰어난 금속 패널을 기존의 시공법 보다 손쉬운 방법으로 시공하기 위한 방법으로 금속 용사 공법을 이용하여 수처리 시설 콘크리트 구조물의 열화를 원천적으로 방지하기 위한 마감공법 개발 연구의 일원으로 용사금속 종류 에 따른 내오존성 평가를 실시하였으며, 실제 하수처리장 환경에서의 전기화학적 안정성능 평가를 실시하였다. 실험결과 용사금속 Ti이 용사 후에도 내오존성이 뛰어난 것으로 나타났으며, 하수처리장 환경에서의 전기화학적 안정성능 평가 결과 용사금속 Ti가 $403.83k{\cdot}{\Omega}{\cdot}cm^2$의 가장 높은 분극저항을 나타남으로써 높은 수준의 내구성을 확보하는 것을 확인할 수 있었다.

분사배출 고도 응집.생물여과 공정을 이용한 하수처리수 중의 TP 및 NOM 제거 (Removal of Phosphorus and NOM in Wastewater Effluent Using Ejector.BAF System)

  • 장영호;강동한;김극태;임흥빈;황찬원;김미정;신형순
    • 한국물환경학회지
    • /
    • 제28권4호
    • /
    • pp.505-511
    • /
    • 2012
  • While the existing sewage treatment facilities are mainly being operated by biological processes, winter-time efficiency improvement and additional phosphorus treatment equipment using chemicals have been required to follow the effluent criteria of TP (0.2, 0.3 and 0.5 mg/L for the zone of I, II and III respectively) and $BOD_5$ (5.0 mg/L) which is intensified from 2012 in Republic of Korea. We made an investigation into actual condition of biological treatment process and calculated the optimal chemical input amount by jar test of supernatant of secondary sedimentation tank to evaluate the process improvement for the intensified criteria. Ejector BAF system for removing TP, $BOD_5$ of sewage effluent was suggested. The concentration of TP from biological process is 0.3-0.8 mg/L, and the input amount of optimal chemical coagulant was above Al/P ratio of 3(1.9 mg/L as Al) to meet the criteria of TP for secondary treatment effluent. From the results of this experiment, the best Al/P ratio for Ejector BAF system was about Al/P ratio of 1, and LV of BAF process for intensified criteria of $BOD_5$ and TP was below 1.97m/hr.

GPS-X 기반 모델링에 의한 강변사업소 처리효율 분석 및 반류수 처리 공정 설계 (GPS-X Based Modeling on the Process of Gang-byeon Sewage Treatment Plant and Design of Recycle Water Treatment Process)

  • 신춘환
    • 한국환경과학회지
    • /
    • 제25권11호
    • /
    • pp.1493-1498
    • /
    • 2016
  • The efficiencies of Gang-Byeon sewage treatment facilities, which are based on GPS-X modelling, were analysed and used to design recycle water treatment processes. The effluent of an aeration tank contained total kjeldahl nitrogen (TKN) of 1.8 mg/L with both C-1 and C-2 conditions, confirming that most ammonia nitrogen ($NH_3{^+}-N$) was converted to nitrate nitrogen ($NO_3{^-}-N$). The concentrations of $NH_3{^+}-N$ and $NO_3{^-}-N$ were found to be 222.5 and 227.2 mg/L, respectively, with C-1 conditions and 212.2 and 80.4 mg/L with C-2 conditions. Although C-2 conditions with higher organic matter yielded a slightly higher nitrogen removal efficiency, sufficient denitrification was not observed to meet the discharge standards. For the total nitrogen (T-N) removal efficiency, the final effluent concentrations of T-N were 293.8 mg/L with biochemical oxygen demand (BOD) of 2,500 mg/L, being about 1.5 times lower than that (445.3 mg/L) with BOD of 2,000 mg/L. Therefore, an external carbon source to increase the C/N ratio was required to get sufficient denitrification. During the winter period with temperature less than $10^{\circ}C$, the denitrification efficiency was dropped rapidly even with a high TKN concentration (1,500 mg/L). This indicates that unit reactors (anoxic/aerobic tanks) for winter need to be installed to increase the hydraulic retention time. Thus, to enhance nitrification and denitrification efficiencies, flexible operations with seasons are recommended for nitrification/anoxic/denitrification tanks.