• Title/Summary/Keyword: sewage facility

Search Result 152, Processing Time 0.022 seconds

A Study on the Characteristics of Small-scale Sewage Treatment Plants in Mountain Area and Operation Plan for Winter Season (산악지역 소규모하수처리시설의 특성 및 동절기 운영방안에 관한 연구)

  • Chae, Heejun;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.23 no.2
    • /
    • pp.183-188
    • /
    • 2021
  • In the case of small-scale sewage treatment plants, it is reported that the amount of inflow fluctuates and it is difficult to operate the sewage treatment due to the inflow of unknown water due to the aging of sewage pipes. In particular, there are many overall operational problems due to the decrease in water temperature in winter. In this study, the operation status of small-scale sewage treatment facilities located in mountainous areas and water quality changes according to temperature were analyzed. It was found that the concentration of BOD, COD, and SS in effluent water was greatly changed depending on the temperature, and it was found that COD was particularly affected. Accordingly, the water level of the bioreactor was raised by 0.4m in order to temporarily apply measures to lower the water temperature in winter. As a result of comparing and analyzing the results when the bioreactor was covered and operated, a significant improvement effect occurred. In addition, a plan to improve the treatment efficiency of the bioreactor in winter is to extend the residence time of the bioreactor, a plan to expand the bioreactor specification, a new flow control tank and transport it to the outside, and an oxygen-free air diffuser to be used as an aerobic tank in case of an emergency in winter. The improvement plan was suggested. The results of this study are expected to be used as basic data for the operation plan of small-scale sewage treatment facilities in winter.

Recycling of a discarded septic tank as a rainwater management system and it's economic feasibility analysis (폐정화조를 재활용한 다목적 빗물관리시스템 구상 및 경제성 분석)

  • Kim, Mikyeong;Kwak, Donggeun;Han, Mooyoung;Yang, Jichung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.647-654
    • /
    • 2009
  • Since the end of the 1990s, sewer pipe improvement works have been going on: most septic tanks have been thrown away and discarded. These discarded septic tanks amounts up to 370,000 based on the project plan 2005-2008: it is a serious squander of nation's resources, a contaminating means that buries toxins under soil, and a cause of a expensive waste. Research on recycling of discarded septic tank as a new resource is in urgent need. This research suggests plans to recycle discarded septic tank as a rainwater management facility, solutions to water cycle recovery in the limelight, and economic analysis of the plan. In the case of a recycling discarded septic tank as a rainwater management facility will socially benefit to support economical adequacy, discard cost saving of septic tank and water supply and sewage cost reduction will come out. Consequently a rainwater management facility converted from a discarded septic tank leads to decentralization of the rainwater management system, which anticipates a positive effect on recovery of urban water cycle.

Evaluation of Carrying Capacity and Sustainability of Jeju Island using Onishi Model (Onishi Model을 이용한 제주도 기반시설 환경용량 산정 및 지속가능성 평가)

  • Park, Jinseon;Kim, Solhee;Kim, Yooan;Hong, Sewoon;Suh, Kyo
    • Journal of Korean Society of Rural Planning
    • /
    • v.26 no.2
    • /
    • pp.95-106
    • /
    • 2020
  • The Onishi model is an objective indicator which can be used to evaluate the relevance of city environmental management in regard to the capacities and processing status of existing urban infrastructure. This study is to analyze the facility carrying capacity and processing status of Jeju Island, a famous tourist site in South Korea. General variables covered by the Onishi model are considered, including water supply, wastewater treatment, waste disposal, and air pollution. Furthermore, the facility carrying capacities for transportation, such as airports and ports, as well as accommodations are assessed as variables pertinent to the characteristics of Jeju island. With the annual number of tourists exceeding that of residents on the island, more facilities for sewage treatment and waste disposal are required. Furthermore, transportation and accommodations used by tourists have already exceeded their capacity. For the future sustainability of Jeju Island, a plan will be needed for adjusting the volume of tourists based on the capacity of each relevant facility.

The Types of Extended-Spectrum ${\beta}$-Lactamases Isolated from Suyeong Sewage Disposal Plant, Busan Environmental Corporation (부산 수영공공하수처리시설에서 분리된 광범위 항균제 베타락 탐 분해효소(Extended-Spectrum ${\beta}$-Lactamase, ESBL) 유형)

  • Kim, Gun-Do;Lee, Hun-Ku
    • Korean Journal of Microbiology
    • /
    • v.46 no.1
    • /
    • pp.38-45
    • /
    • 2010
  • The study performed to identify the type of ESBL against strains which are producing extendedspectrum ${\beta}$-lactamases and isolated from sewage in Suyeong sewage disposal plant, Busan Environmental Corporation. By the standard activated sludge method, Suyeong sewage disposal plant purify living and lavatory sewage gathering from the northeast Busan and the facility purify total 550,000 tons of living sewage disposal a day. 14 strains were isolated by double disk synergy test and the third generation cepha-antibiotics test. Indole, methyl-red, Voges-Proskauer, Simmon's citrate, decarboxylasedihydrolase and sugar-fermentation tests identified as Klebsiella pneumoniae (n=4) and Escherichia coli (n=10). Plasmid-mediated transmission test against isolated 14 strains proved 11 strains transmitted resistance to recipient E. coli J53 (sodium $azide^R$, $ceftazidime^S$). 9 strains of conjugant were expressed ESBL genes transferred from parental strain but 2 conjugants did not expressed. The type of ESBL from each strain was determined by isoelectric focusing points, DNA and amino acids sequencing. The results indicated that the types of ESBL transmitted to recipient E. coli J53 were TEM-1, the parental TEM type and SHV-12 type.

Study on the growth and control of algae using effluent of sewage treatment facility (하수처리장 방류수 재이용에 따른 조류 생장 및 제어방안 연구)

  • Park, Soo young;Kim, Jin Han;Park, Jung Hwan;Ahn, Kyung Soo
    • Journal of Wetlands Research
    • /
    • v.7 no.3
    • /
    • pp.67-73
    • /
    • 2005
  • At research, the river's water which the sewage treatment facility will ask growth suppression the algae in the artificial rivers which it is using or it researched the method for the removal of the algae which grew. At results, when 60ppm of Chlorine was put in, the possibility of getting the result where 90% chlorophyll-a was removed and LC50 was 0.8ppm. The algae did not create even after 20days by which uses prevent agent of creation of the algae. Controlling the chlorine almost there was not an extinction effect of the algae which was already in large quantities multiplied, with in the effect against an water ecosystem widely known it is not. The prevent agent could inhibit creation of the algae, but it was judged with the fact that the methods are directly applied to the field must be researched continuously.

  • PDF

Characteristics of Ammonia in Alkaline Stabilization Facility of Sludge from Sewage Treatment Plant (하수처리오니 알칼리 안정화 처리시설에서의 암모니아 발생특성)

  • Kim, Yong-Jun;Chung, David;Jeong, Mi-Jeong;Yoo, Hye-Young;Yoon, Cheol-Woo;Shin, Sun-Kyoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.3
    • /
    • pp.23-33
    • /
    • 2016
  • The characteristics of ammonia generated from alkaline stabilization facilities was investigated which are for organic sewage sludge from wastewater treatment plants. The highest concentration of ammonia was found in mixing and curing process in alkaline stabilization facility and ammonia mainly showed a range of 87.78 ppm($66.62mg/m^3$) to 1,933 ppm($1,467.01mg/m^3$) by detection tube. This is presumed to occur because nitrogen oxides are converted into ammonia as the sewage sludge is mixed with lime. In some facilities, hydrogen sulfide and methyl mercaptan were detected in relatively high concentrations, but odor materials except ammonia were not detected in most of the facilities. The concentration of ammonia caused by process was generally high in the order of "mixing > curing > output > storage > drying > input." It was found that odor compounds are removed by wet absorption using sulfuric acid and sodium hypochlorite in the 5 alkaline stabilization facilities currently in operation. Each facility was designed to meet the concentration of after-treatment emission in 1 ppm($0.76mg/m^3$), 50 ppm($37.95mg/m^3$) or 100 ppm($75.89mg/m^3$), but no facility satisfied the design standard for their emssion limit. In case of ammonia, some workplaces in alkaline stabilization facilities exceeded the exposure limits established by the Ministry of Labor. It appears that proper ventilation should be provided for the safety of workers in future. No odor compound including ammonia was found by detection tubes in the border of the facilities, but trace amounts of odor compounds are expected to exist, given the current operational status of facilities.

Development of underground facility information collection technology based on 3D precision exploration (3차원 정밀탐사 지하시설물 정보 수집 기술 개발)

  • Jisong RYU;Yonggu JANG
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.4
    • /
    • pp.56-66
    • /
    • 2023
  • Safety accidents are increasing, such as changes in groundwater levels due to construction work or natural influences, or ground cave-ins caused by soil runoff from old water supply and sewage pipes. In addition, underground facility management agencies must make efforts to improve the accuracy of underground information through continuous investigation and exploration in accordance with the Special Act on Enhanced Underground Safety Management. Accordingly, in this study, we defined the configuration of equipment and data processing method to collect 3D precise exploration underground facility information and developed 3D underground facility information collection technology to ensure accuracy of underground facilities. As a result of verifying the developed technology, the horizontal accuracy improved by an average of 6cm compared to the existing method, making it possible to acquire 3D underground facility information within the error range of the public survey work regulations.

Analysis and Prediction of Sewage Components of Urban Wastewater Treatment Plant Using Neural Network (대도시 하수종말처리장 유입 하수의 성상 평가와 인공신경망을 이용한 구성성분 농도 예측)

  • Jeong, Hyeong-Seok;Lee, Sang-Hyung;Shin, Hang-Sik;Song, Eui-Yeol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.308-315
    • /
    • 2006
  • Since sewage characteristics are the most important factors that can affect the biological reactions in wastewater treatment plants, a detailed understanding on the characteristics and on-line measurement techniques of the influent sewage would play an important role in determining the appropriate control strategies. In this study, samples were taken at two hour intervals during 51 days from $1^{st}$ October to $21^{st}$ November 2005 from the influent gate of sewage treatment plant. Then the characteristics of sewage were investigated. It was found that the daily values of flow rate and concentrations of sewage components showed a defined profile. The highest and lowest peak values were observed during $11:00{\sim}13:00$ hours and $05:00{\sim}07:00$ hours, respectively. Also, it was shown that the concentrations of sewage components were strongly correlated with the absorbance measured at 300 nm of UV. Therefore, the objective of the paper is to develop on-line estimation technique of the concentration of each component in the sewage using accumulated profiles of sewage, absorbance, and flow rate which can be measured in real time. As a first step, regression analysis was performed using the absorbance and component concentration data. Then a neural network trained with the input of influent flow rate, absorbance, and inflow duration was used. Both methods showed remarkable accuracy in predicting the resulting concentrations of the individual components of the sewage. In case of using the neural network, the predicted value md of the measurement were 19.3 and 14.4 for TSS, 26.7 and 25.1 for TCOD, 5.4 and 4.1 for TN, and for TP, 0.45 to 0.39, respectively.

A Study on Membrane Fouling Contaminants and Control in Enhanced Sewage Treatment by Submerged Membrane Bioreactor (침지형 분리막을 이용한 오수고도처리 공정의 막오염 원인물질 및 제어에 관한 연구)

  • Park, Chul-Hwi;Yun, Jae-Gon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.619-627
    • /
    • 2004
  • Purposes of this study were to examine closely the extracellular polymeric substances (EPS) which was a membrane fouling contaminant, to control detected EPS by powdered activated carbon (PAC) dosage etc. and to evaluate the possibility of practical reuse facility. With high removal efficiency of general pollutants, when the PAC is added to MBR, improvement of removal efficiency of $COD_{cr}$, and color was expected and treated wastewater can be reused. It was judged that the correlation between EPS and membrane fouling was very high. Carbohydrate and DNA in the EPS were judged to be cause of membrane fouling. If EPS could be controled, not only membrane fouling would be decreased but also operation time would be extended. In experiment of powdered activated carbon (PAC), characteristics of the best PAC for membrane fouling control were the particle size of $7{\mu}m$, lodine Number of 1,050, surface area of peat of $1,150m^2/g$. In lab test, operation time of MBR by PAC dosage of 200mg/gVSS was longer than one of MBR by without PAC dosage. Because EPS, especially carbohydrate and DNA, was controled successfully by PAC, membrane fouling in MBR could be decreased.

A Study on the Improvement of Sludge Digestion Efficiency by Solubilization Equipment and Gas Purification System (가용화장치 및 가스정제 설비에 의한 슬러지 소화 효율 향상에 관한 연구)

  • Jang, Seong-Ho;Yi, Pyong-In;Lee, Yong-Dea;Kim, Han-Soo;Cho, Han-Jin;Ryu, Jae-Young;Kim, Sang-Woo
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.853-859
    • /
    • 2014
  • The purpose of this study was to improve low digestibility in anaerobic digestion facility of the sewage treatment plant. To perform this research, sludge digestion and digestion gas purification facilities in sewage treatment plant was applied. In the result of this study, it was very effective for sludge reduction from the improvement of digestive efficiency. In addition, it was confirmed that high purity $CH_4$ (methane) was produced. This results can be useful as basic data to improve the low digestibility in anaerobic digestion processes.