• Title/Summary/Keyword: sewage disposal plant

Search Result 63, Processing Time 0.034 seconds

Characteristics of Acidic Gas Emissions from Combustion with Preblending of Coal and Sludge (석탄과 슬러지의 예혼합연소에 따른 산성가스 배출특성)

  • Shim, Sung-Hoon;Jeong, Sang-Hyun;Min, Hyo-Ki;Lee, Sang-Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.2
    • /
    • pp.103-108
    • /
    • 2014
  • Using dried sludge as a secondary fuel of a coal-fired power plant is proposed as an alternative option for sludge disposal. Because elemental contents of sludge are different from those of coal, different levels of acidic gas emissions are expected from the co-combustion of sludge with coal. In this study, sludge samples were obtained from 7 sewage treatment plants in Korea. Each sludge sample was combusted together with coal in a lab-scale combustor, and the concentrations of nitrogen oxides ($NO_x$), sulfur dioxide ($SO_2$), hydrogen chloride (HCl), chlorine ($Cl_2$) in the flue gas were analyzed. Compared to the combustion of coal only, $NO_x$ concentration was slightly higher in the flue gas from the co-combustion of coal and sludge. $SO_2$ emission increased with the combustion of sludge due to the higher content of sulfur in sludge than in coal. For most of the tested samples, the concentrations of HCl and $Cl_2$ were varied depending on the chlorine content in the sludge sample.

A Study on the Distribution of Atmospheric Concentrations of Sulfur Compounds by GC/FPD (GC/FPD에 의한 대기 중 황화합물 농도분포에 관한 연구)

  • Yang, Sung Bong;Yu, Mee Seon;Hwang, Hee Chan
    • Analytical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.240-248
    • /
    • 2003
  • Sulfur compounds which are well-known odor-active compounds in industrial area have very low detection threshold values. Trace amounts of volatile sulfur compounds in enviroment air around several odor sources were concentrated in liquid argon bath and determined by gas chromatograph with flame photometric detector (FPD) which exhibits very good selectivity and sensitivity. 25% ${\beta}$,${\beta}$-Oxydipropionitrile on 60/80 Chromosorb W was used as adsorbent for the preconcentration of sulfur compounds in air sample and also as packing material for a packed glass column. Concentration volume of air sample was different from place to place in the range of 0.1~3.0L. Atmospheric concentrations of sulfur compounds in air of residential districts and boundaries of business establishments, and also those in the exhausted gases of emission points such as a sewage disposal plant in industrial area were measured.

A Study on Drying and Carbonization of Organic Sludge from Sewage Plant and Petrochemical Industries for Energy and Resources Recovery (하수슬러지 및 석유화학산업단지 폐수슬러지의 에너지화와 재활용을 위한 건조 및 탄화에 관한 연구)

  • Jun, Kwan-Soo;Hwang, Eung-Ju;Kim, Hyung-Jin
    • Clean Technology
    • /
    • v.15 no.3
    • /
    • pp.154-164
    • /
    • 2009
  • In 2007, 94% of organic wastewater sludge from industries located in Ulsan was disposed of by ocean dump. The ocean dump of organic sludge would be totally prohibited by the year of 2012. However, there is no alternative but incinerating the sludge from the industries located in Ulsan. Securing the technology for sludge treatment and on-land disposal is very important issue among the industries in the Ulsan Petrochemical Industry Complex. In this study, the material aspects of dried and carbonized sludge as a fuel were evaluated for petrochemical and sewage sludge from Ulsan. The dried and carbonized sludges from the factories producing terephthalic acid, BTX, propylene, chemical textile, etc. of which the low heat value exceeded 3,000 kcal/kg had high potential as a fuel according to the results of thermal characteristic analysis. However, the dried sludges with heat values lower than 2,100 kcal/kg and carbonized sludges, lower than 1,100 kcal/kg containing more Inorganic material from the industries producing pulp, paper, methylamine, amide, etc. had a little potential to be used as a fuel. In most cases, drying the sludge showed better results than carbonization in the aspect of thermal characteristics of sludge.

A Surveying on the Sewage System in Seoul (수도권 하수방제 방식에 관한 조사 연구)

  • 남궁악
    • Water for future
    • /
    • v.15 no.2
    • /
    • pp.11-22
    • /
    • 1982
  • This study is to find out the reasonable drainage system of sewerage in connection with the geographical conditions, the form of city, and the problem of sewerage in and around Seoul. (1) In supplying the sewerage sewer, the separating system is desirable in connection with the problem of sewerage disposal in future. However, in the existing urban district, the conjunction system is used because of the large amount invested according to the diversion of the sewer of the separation system and the influence of the traffic communication. The sewer of the separating system should be used in the case of the fundamental reconstruction of structure as the redevelopment of the urban district or the subway and new-development of area. Therefore, the separating system should be used completely until the goal year. (2) Drainage area was divided for the natural flowing, considering that the 38 streams and topography paly a role of the main stream of drainage. There are the branches, Guyui, Dug-island, Jayang, Hannam, Banpo, Amsa whose divisions are impossible. In these branches, the drain planning was suggested a forced control method by using the exiting pond age and the pumping station. (3) The best available method which improbes the water quality in Han river is as follows. The sewerage is catched and carried to the sewerage disposal plant by establishing the intercept sewer in both or one side of stream. At the same time, the groudwater volume which springs in each stream is drained separatively.

  • PDF

Contamination of the Mushim-Cheon and its Countermeasure;II. The Status of the Seasonal and Hourly Contamination of the Water(1989${\sim}$1990)-Temperature, pH, DO, BOD, COD, SS, Turbidity, and BOD Load (무심천(無心川) 수질(水質) 오염(汚染) 실태(實態)와 그 방지책(防止策);II. 계절별(季節別) 및 시간별(時間別) 현황(現況) (1989-1990)-수온, pH, DO, BOD, COD, SS, 탁도 및 BOD 부하량(負荷量))

  • Lee, Jae-Koo;Kim, Hak-Nam;Kyung, Kee-Sung;Kwak, Hee-In
    • Korean Journal of Environmental Agriculture
    • /
    • v.10 no.1
    • /
    • pp.33-49
    • /
    • 1991
  • In order to disclose the contamination of the Mushim-Cheon by pollutants and to establish the countermeasures, the water samples collected in November of 1989(lst sample), February(2nd), May(3rd) and August of 1990(4th) were analyzed to obtain the following results : 1. The water temperatures of the seasonal samples ranged from 8.6 to 16.2, 8.3 to 25.2, 18 to 26, and 24 to 32$^{\circ}C$, in the 1st, 2nd , 3rd, and 4th samples, respectively. 2. The pHs of all the samples ranged from 6.5 to 8.5. 3. In the 3rd sample, especially, DO was observed to fall down to 0.8 ppm at the downstream of St 13, which is not allowed even for agricultural use. 4. The BOD and COD values in sewers were much higher than those in the main stream, and especially the values of St 14-A reached 107-608 and 176-635 ppm, respectively, which far exceeded the limit of 40 ppm, the allowed value for the discharges from the disposal facilities. The SS value of St 14A ranged from 142 to 1, 900 ppm, which far exceeded the limit of 70 ppm, the allowed value for the discharges from the disposal facilities. 5. It turned out that the water quality of the Mushim-Cheon flowing through Cheong Ju was more worsened at sewers than the main stream, and at the downstream than the upstream of the surveyed area. Accordingly, the sewage disposal plant and the expansion of the disposal facilities are urgently needed.

  • PDF

A Feasibility Study on the Use of Liner and Cover Materials Using Sewage Sludge (하수슬러지의 차수재 및 복토재로의 이용타당성에 관한 연구)

  • 유남재;김영길;박병수;정하익
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.2
    • /
    • pp.43-71
    • /
    • 1999
  • This research is an experimental work of developing a construction material using municipal wastewater sludge as liner and cover materials for waste disposal landfill. Weathered granite soil and flyash, produced as a by-product in the power plant, were used as the primary additives to improve geotechnical engineering properties of sludge. For secondary additives, bentonite and cement were mixed with sludge to decrease the permeability and to increase the shear strength, respectively. Various laboratory test required to evaluate the design criteria for liner and cover materials, were carried out by changing the mixing ratio of sludge with the additives. Basic soil properties such as specific gravity, grain size distribution, liquid and plastic limits were measured to analyze their effects on permeability, compaction, compressibility and shear strength properties of mixtures. Laboratory compaction tests were conducted to find the maximum dry densities and the optimum moisture contents of mixtures, and their effectiveness of compaction in field was consequently evaluated. Permeability tests of variable heads with compacted samples, and the stress-controlled consolidation tests with measuring permeabilities of samples during consolidation process were performed to obtain permeability, and to find the compressibility as well as consolidational coefficients of mixtures, respectively. To evaluate the long term stability of sludges, creep tests were also conducted in parallel with permeability tests of variable heads. On the other hand, for the compacted sludge decomposed for a month, permeability tests were carried out to investigate the effect of decomposition of organic matters in sludges on its permeability. Direct shear tests were performed to evaluate the shear strength parameters of mixed sludge with weathered granite, flyash and bentonite. For the mixture of sludge with cement, unconfined compression tests were carried out to find their strength with varying mixing ratio and curing time. On the other hand, CBR tests for compacted specimen were also conducted to evaluate the trafficability of mixtures. Various test results with mixtures were assessed to evaluate whether their properties meet the requirements as liner and cover materials in waste disposal landfill.

  • PDF

Study on Physical Oceanographic Environments in the Coastal Sea of Chung-Moon, Cheju Island (제주도 중문 연안역의 물리해양환경에 대한 연구)

  • Hong, Chang-Su;Oh, Kyung-Hee;Pang, Ig-Chan
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.6 no.4
    • /
    • pp.211-217
    • /
    • 2001
  • Physical oceanographic environments in the coastal sea of Chung-Moon located in the south coast of Cheju Island, Korea, where water pollutions by growing tourism complex possibly start to influence on the ecological system, are studied with hydrographic data observed monthly during July 1997 to June 2000. Winter and summer characteristics are shown in December to April and June to October, respectively, and transitional characteristics are shown in May and November. Waters show 14{\sim}16^{\circ}C$ and 34${\sim}$34.7 psu in winter and $15{\sim}27^{\circ}C$ and 32${\sim}$34.3 psu in summer. It tells that Tsushima water distributes in the whole column in winter and in the lower layer in summer, and Yangtze coastal water appears in the surface water in summer. When the influence of Yangtze coastal water is strong, salinities below 30psu are shown. Stratification is formed in the depth of about 20 m from June to October, so that it is not shown in the near shore stations, of which the depth is about10 m. Isotherms and isohalines sometimes tend to be perpendicular to the coast line in the surface, which seems to show influences from the steam power plant near St. 1 and the sewage disposal plant near St. 3. During the observation period, temperatures in St. 1 are a little higher than those in St. 2 and St. 3 except for a couple of months in summer and salinities in St. 3 are mostly a little lower than those in St. 1 and St. 2. Their effects seem to be no more than $0.4^{\circ}C$ in a distance of 300 m and no more than 0.1 psu within a distance of 30 m.

  • PDF

The Effects of Environmental Factors on Biodegradability Test for Lubricant Products (환경인자가 윤활제품의 생분해도 시험에 미치는 영향)

  • Cho, Eun-Hye;Park, Keun-Hyoung;Han, Seung-Ock;Kim, Eui-Yong;Ryu, Jae-Sang;Jang, Sun-Bok;Lee, Un-Gi;Chae, Hee-Jeong
    • KSBB Journal
    • /
    • v.23 no.4
    • /
    • pp.285-290
    • /
    • 2008
  • Various methods (OECD 301B, ISO 9439 and ASTM 5864) for biodegradability test of lubricants were reviewed, and a standard procedure was developed. Most lubrication products are released in rivers or sea then is degraded by microbial action in aerobic condition. Most international method are based on $CO_2$ evolution test. Inoculum obtained from a sewage disposal plant and test compound are cultivated in a mineral medium. Organic carbon of the test compound is degraded and oxidized through the enzymatic actions of inoculum, and ultimately mineralized to carbon dioxide. Biodegradability test conditions of lubricant oils were optimized. The highest biodegradability was achieved when the same medium as in ASTM 5864 and inoculum concentration of $10^4{\sim}10^5$ cell/L were used. The optimum standard materials were selected as aniline and sodium acetate. Additionally the effects of inoculum type on microbial growth and biodegradability were examined. Finally the standard operating procedure (SOP) for biodegradability test method was proposed.

Pollution History of the Masan Bay, Southeast Korea, from Heavy Metals and Foraminifera in the Subsurface Sediments (중금속 원소와 유공충을 이용한 마산만 퇴적물의 오염 역사에 관한 연구)

  • Cho, Jin-Hyung;Jeong, Kap-Sik;Chung, Chang-Soo;Kwon, Su-Jae;Park, Sung-Min;Woo, Han-Jun
    • Journal of the Korean earth science society
    • /
    • v.24 no.7
    • /
    • pp.635-649
    • /
    • 2003
  • Heavy metal concentrations and benthic foraminiferal distributions were investigated in three short sediment cores in order to understand the pollution history in Masan Bay. Sedimentation rates were 0.33 cm/yr, 0.20 cm/yr and 0.33 cm/yr in the inner bay, the out fall of Dugdong sewage disposal plant, and bay mouth, respectively. The rapid increases of copper, zinc and lead concentrations at the core depth of 10 cm the upper part indicated that Masan Bay has been polluted with industrial wastes since the 1940s. Benthic foraminifera in core sediments show that the variations in their distribution were followed by industrial pollution in the bay. The number of individuals and species diversity decreased, whereas agglutinated tests increased upward in the cores with increased heavy metal pollution. These shifts effectd the abundance of few tolerant forms and consequently decreased the species diversity. The opportunistic species Eggerella advena and Trochammina pacifica increased in polluted sediments. These species can be used as an indicator for assessments of environmental quality in Masan Bay.

Effects of Civil Blasting on Noise, Vibration and Total Suspended Particles (토목 발파가 소음, 진동, 부유 분진에 미치는 영향)

  • Jeong, Jin Do;Jeong, Yeong Guk
    • Journal of Environmental Science International
    • /
    • v.13 no.1
    • /
    • pp.99-107
    • /
    • 2004
  • This research is to determine the level of environmental pollution at a blasting construction area which is the origin of noise, vibration, and suspended particle, and to compare the results with other domestic and international standard data. This experiment is also to find out the effects resulting from blasting construction and to propose a plan that can decrease environmental pollution. The blasting construction area is a factory site which is about one and half million square meter and sewage disposal plant is about ninety thousand square meter. Both were selected as the areas for the tests to be conducted in determination test. The test to determine the level of noise, vibration, and total suspended particle was conducted thirty times around the blasting construction area by comparing measurement results and numerical analysis. However, as the test was not conducted in the laboratory but in the actual blasting construction area, it was not possible to do the test with the same exact conditions each true. Therefore, the test was not ideal as conditions could change from test to test. For the most part, the level of noise was below the standard level of 70dB. Every vibration test was under the standard limitation. For example, a house, 200m away was tested for noise and vibration and the level was found to be under the 0.2 cm/sec which is the standard for specialty designed cultural sites., i.e very low level. Also a buried oil pipeline that was 30m away also marked under 2.0cm/sec which is the norm for an industrial area. However, if there were an oil pipeline under the house, the amount of charging gunpowder per hole should be decreased compared to the amount used in the test. The test result for suspended particles under the standard limitation which is 24hour average 300$\mu\textrm{g}$/㎥ at a distance from blasting wavelength, but at detonator, total suspended particle from the blast origin exceeded the standard limitation. If explosion occurs when it detonates in the hole, most of the energy would be absorbed in the crushing of rocks, but some remaining energy would make noises and vibration inevitable. So the important thing is how to minimize the environmental pollution from the blasting. There should be regulations in order that the standard limitation is not exceeded, and to decrease the environmental pollution from the blasting.