• 제목/요약/키워드: sewage disposal

Search Result 164, Processing Time 0.022 seconds

Feasibility Study on the Reuse of Treated Sewage Effluent for Agrcultural Water (농촌오수 처리수의 농업용수로의 재이용 가능성에 관한 연구)

  • 권태영;윤춘경
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.663-669
    • /
    • 1999
  • The objective of this study are to examine the feasbility of reuse treated sewage effluent ofr agricultural water, and to obtain basic data for estabilishment of rational agricultural water quality standard. From this study, it appears that reuse of treated sewage as a supplemental irrigation water could be feasible and practical alternative for ultimate sewage disposal which often causes water quality problem to the receiving water body. For full scale applicatiion, further study is recommended on the secific guidelines of major water quality components and publc health.

  • PDF

Study on operating software for monitoring device network in sewage disposal facility (오수처리시설의 가동상태 확인 기기 네트웤의 운영 소프트워어에 관한 연구)

  • 박승환;김창복;김성선
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.1
    • /
    • pp.74-79
    • /
    • 2002
  • In field of environments the monitoring devices for sewage disposal facilities developed to overcome a problem of the water contamination according to industrializaion and urbanization. This paper presents the operating software for monitoring device network which operator in remote station is able to check and see the operating states of the sewage disposal facilities installed in local stations. The software is executed by the hardware base developed by this study and composed of the Program modules for database, data transmission and operating state analysis. As the result of the proposed software system, it is confirmed that we are able to make improvements of the effectiveness of the operating management for environment equipments.

  • PDF

The Types of Extended-Spectrum ${\beta}$-Lactamases Isolated from Suyeong Sewage Disposal Plant, Busan Environmental Corporation (부산 수영공공하수처리시설에서 분리된 광범위 항균제 베타락 탐 분해효소(Extended-Spectrum ${\beta}$-Lactamase, ESBL) 유형)

  • Kim, Gun-Do;Lee, Hun-Ku
    • Korean Journal of Microbiology
    • /
    • v.46 no.1
    • /
    • pp.38-45
    • /
    • 2010
  • The study performed to identify the type of ESBL against strains which are producing extendedspectrum ${\beta}$-lactamases and isolated from sewage in Suyeong sewage disposal plant, Busan Environmental Corporation. By the standard activated sludge method, Suyeong sewage disposal plant purify living and lavatory sewage gathering from the northeast Busan and the facility purify total 550,000 tons of living sewage disposal a day. 14 strains were isolated by double disk synergy test and the third generation cepha-antibiotics test. Indole, methyl-red, Voges-Proskauer, Simmon's citrate, decarboxylasedihydrolase and sugar-fermentation tests identified as Klebsiella pneumoniae (n=4) and Escherichia coli (n=10). Plasmid-mediated transmission test against isolated 14 strains proved 11 strains transmitted resistance to recipient E. coli J53 (sodium $azide^R$, $ceftazidime^S$). 9 strains of conjugant were expressed ESBL genes transferred from parental strain but 2 conjugants did not expressed. The type of ESBL from each strain was determined by isoelectric focusing points, DNA and amino acids sequencing. The results indicated that the types of ESBL transmitted to recipient E. coli J53 were TEM-1, the parental TEM type and SHV-12 type.

A Study on the applications of flow control methods in sewage treatment process system (하수처리 공정시스템에서 유량제어기법의 활용에 관한 연구)

  • Jeong, Seong-Yun;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.597-604
    • /
    • 2016
  • This study was begun with the object of actively reflection the rapid technological advancements of the electronical control and mechanical control industries to sewage disposal methods. Or focuses on applying a flow control method that utilizes inverters and automatic valves to sewage treatment process systems. This study proposes that sewage treatment process systems architects must acquire a certain degree of technical skills in the areas of electrical and mechanical controls in order to raise the standard of completeness of sewage treatment process systems. And further emphasizes that there is required continuous research on automatics valves that are used in sewage treatment.

Characteristics of Sewage sludge, Its Incineration Ash, and Sintering Pellet

  • Lee, Ki-Hwan;Lee, Tae-Ho;Cho, Heon-Young;Han, Ki-Suk
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.4
    • /
    • pp.215-220
    • /
    • 2000
  • This study on the incineration ash and sintering pellet from sewage sludge was carried out to evaluate the possibility of recycling in sewage sludge disposal. The samples used in this experiment were raw sewage sludge, its incineration ash, and sintering pellet. The characteristics of the three sample types were identified using X-ray diffraction(XRD), X-ray fluorescence(XRF), atomic absorption spectroscopy(AAS), and inductively coupled plasma spectroscopy(ICP). The chemical compositions of all three sample types were similar in their clay component, however, the sewage sludge had a high content of organic materials. From an analysis of the mineral content of the three sample types, the conversion of their compositions was found to be relative to temperature. Accordingly, incineration ash and sintering pellet both have potential for use as a functional construction material.

  • PDF

Effect of Reclaimed Sewage Irrigation on Paddy Rice Culture and Soil Characteristics (오수처리수의 관개가 벼 생육 및 토양 특성에 미치는 효과)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.3
    • /
    • pp.66-75
    • /
    • 2000
  • Effect of reclaimed sewage on the paddy rice culture was examined by field experiment for two consecutive years. The domestic sewage was treated by the constructed wetland and the effluent of the treatment wetland was used for irrigation water. The reclaimed sewage was diluted before irrigation in the first year and it was used without dilution in the second year experiment. Growth components and yields were compared against the control plot where conventional method was applied. And also soil characteristics of the plots before and after reclaimed sewage irrigation were analyzed Generally addition of the reclaimed sewage irrigation didn't affect paddy rice culture adversely and even enhancement was observed. Fertilization was thought to be important factor for rice culture rather than irrigation water quality. Conventional fertilization and reclaimed sewage irrigation which contained high nutrient concentration resulted in better growth and more yield. Unlike widespread concern lodging did not happen even in the case of irrigation with average 90mg/L of T-N and conventional fertilization. Soil characteristics changed after irrigation and significant EC increasing was observed for the reclaimed sewage irrigation plots. From soil analyses salt accumulation could be a more potential problem than nutrients like nitrogen and phosphorus in the use of reclaimed sewage irrigation. Overall reclaimed sewage irrigation was thought to be one of practical alternatives for the ultimate disposal of sewage in rural area.

  • PDF

Study on the Performance of Constructed Wetland System for Sewage Treatment (인공습지 오수처리시설의 처리성능에 관한 연구)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.4
    • /
    • pp.96-105
    • /
    • 2000
  • Field experiment was performed from August 1996 to December 1999 to examine the performance of constructed wetland system for wastewater treatment in rural area. The constructed wetland system was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the treatment basin. The treatment basin was composed of sand bed with planted reed. From August 1996 to June 1998 the hydraulic loading rate was fixed with about 15.63cm/day and theoretical detention time was 1.38 days, and from July 1998 to December 1999 the hydraulic loading rate was about 6.25cm/day and theoretical detention time was 3.5days. It worked continuously even during winter time, and the sewage flowed without freezing even when average daily air temperature was below -1$0^{\circ}C$. Average removal rate of BOD , COD, and SS was about 70%, T-P removal rate was about 50.8% , and T-N removal rate was 23.9%. The reason for poor T-N removal might be due to high influent concentration and short retention times. At the later years BOD and COD removal rates were increased , and SS and T-P removal rates did not change significantly , but T-N removal rates were decreased. The effluent of the wetland system often effluent water quality standards for sewage treatment plant, therefore, further treatment would be required if the effluent need to be discharged to the public water. Wetland system involves relatively large land area and could be suitable for rural area. Therefore, utilization of reclaimed sewage for agricultural purpose or subsequent land treatment is recommended as a ultimate disposal of sewage for agricultural purpose or subsequent land treatment is recommended as a ultimate disposal of sewage in rural area.

  • PDF

Advanced Treatment of Sewage Using Waste Plastic Vessel Media (폐플라스틱용기 미디어를 활용한 오수고도처리)

  • Kim, Jae-Yong;Um, Myeong-Heon;An, Dae-Hyun;Shim, Myeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.58-61
    • /
    • 2006
  • The object of this study was to develop an advanced method for fluid flow and oxygen transmission and increase adhesive property of microorganism to waste plastic vessel that was made of microorganism media. Through lab scale experiments, we found the optimum packed media volume rate and method, and when the optimum condition was applied to pilot plant, we confirmed possibility of advanced treatment. The sewage that was used in the test was the sewage disposal facility established in C and K elementary schools, which utilized waste plastic media oxidation engineering method. Analysis showed that removal efficiency of organic matter, SS, T-N and T-P was very high, that the sewage disposal facility maintained stability of treatment when changeable load of raw sewage flowed in.

Pyrolysis and combustion characteristics of dried sewage sludge in a fixed bed reactor (건조 하수 슬러지의 열분해 및 고정층 연소 특성 연구)

  • Kim, Minsu;Lee, Yongwoon;Park, Jinje;Ryu, Changkook
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.29-32
    • /
    • 2014
  • The practical route for disposal of sewage sludge becomes energy recovery by combustion after its ocean dumping is banned in 2012 in Korea. Due to the high moisture content, however, sewage sludge is required to be dried before transport and combustion. In this study, pyrolysis and combustion characteristics of dried sewage sludge was investigated in a small-scale fixed bed reactor in order to provide fundamental data for energy recovery of the fuel. As the first step of combustion, the primary products of pyrolysis were analyzed in a fixed bed reactor for the condensable volatiles (tar), non-condensable gases, and char. For the combustion characteristics, another fixed bed reactor was constructed to monitor the weight and temperature of the fuel particles during ignition and combustion under different air flow rates. The test results were used to derive the ignition and burning rates.

  • PDF

Pretreatment Characteristics and Specific Methanogenic Activity of Municipal Sewage Sludge by Dual Frequency Sonication (이중주파수 초음파를 이용한 도시하수슬러지의 전처리 특성 및 비메탄활성도에 관한 연구)

  • Jung, Byung-Gil;Jang, Seong-Ho;Sung, Nak-Chang
    • Journal of Environmental Science International
    • /
    • v.16 no.2
    • /
    • pp.211-218
    • /
    • 2007
  • The objectives of this study have been carried out to investigate the solubilization of municipal sewage sludge by single and dual frequency ultrasonic pretreatment, and the methane production characteristics of pretreated sewage sludge by specific methanogenic activity test for sewage sludge reduction. The waste activated sludge was collected from thickened tank of Suyoung sewage treatment plant in Busan city, and its concentration was adjusted to 1.0% total solids. Ultrasonic frequency was varied 15, 20, 15+20 kHz, and acoustic density was used a maximum 176W/L. The dual frequency ultrasonic pretreatment was found to be more effective than single frequency ultrasonic in the solubilization rate and methane production. The $SCOD_{Cr}/TCOD_{Cr}$, rate were 15.2%, 13.9%, 17.0% with single frequency of 15 kH2, 20 kHz, dual frequency of 15+20 kHz, respectively. The application of dual frequency ultrasound for sewage sludge pretreatment can be interest for sewage treatment plants having problems in sludge treatment and disposal.