• Title/Summary/Keyword: service pipe

Search Result 170, Processing Time 0.026 seconds

Evaluation on the Effect of Ultrasonic Testing due to Internal Medium of Pipe in Nuclear Power Plant (원자력발전소 배관 내부 매질이 초음파검사에 미치는 영향 평가)

  • Yoon, Byung Sik;Kim, Yong Sik;Yang, Seung Han
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.25-30
    • /
    • 2013
  • The periodic inspection of piping and pressure vessels welds in nuclear power plant has to provide reliable result related to weld flaws, such as location, maximum amplitude response, ultrasonic length, height and finally the nature or flaw pattern. The founded flaw in ultrasonic inspection is accepted or rejected based on these data. Specially, the amplitude of flaw response is used as basic parameter for flaw sizing and it may cause some deviation in length sizing result. Currently the ultrasonic inspections in nuclear power plant components are performed by specific inspection procedure which describing inspection technique include inspection system, calibration methodology and flaw characterizing. To perform ultrasonic inspection during in-service inspection, reference gain should be established before starting ultrasonic inspection by the requirement of ASME code. This reference gain used as basic criteria to evaluate flaw sizing. Sometimes, a little difference in establishing reference gain between calibration and field condition can lead to deviation in flaw sizing. Due to this difference, the inspection result may cause flaw sizing error. Therefore, the objective of this study is to compare and evaluate the ultrasonic amplitude difference between air filled and water filled pipe in nuclear power plant. Additionally, the accuracy of flaw sizing is estimated by comparing both conditions.

Structural Integrity Assessments of Pressurized Pipes with Gouge using Stress-Modified Fracture Strain Criterion (삼축응력 기반의 파괴변형률 기준을 적용한 가우지 손상배관의 건전성 평가)

  • Oh C.K.;Kim Y.J.;Park J.M.;Baek J.H.;Kim Y.P.;Kim W.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.808-813
    • /
    • 2005
  • Structural integrity assessment of defected pipe is important in fitness for service evaluation and proper engineering assessment is needed to determine whether pipelines are still fit for service. This paper present a failure prediction of gas pipes made of APIl X65 steel with gouge using stress-modified true fracture strain, which is regarded as a criterion of ductile fracture. For this purpose, API X65 pipes with gouge are simulated using elastic-plastic FE analyses with the proposed ductile failure criterion and the resulting burst pressures are compared with experimental data. Agreements are quite good, which gives confidence in the use of the proposed criteria to defect assessment fer gas pipelines. Then, further extensive finite element analyses are performed to obtain the burst pressure solution of pipes with gouge as a function of defect depth, length and pipeline geometry.

  • PDF

Prioritization decision for hazard ranking of water distribution network by cluster using the Entropy-TOPSIS method (Entropy-TOPSIS 기법을 활용한 군집별 상수도관망 위험도 관리순위 결정)

  • Park, Haekeum;Kim, Kibum;Hyung, Jinseok;Kim, Taehyeon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.517-531
    • /
    • 2021
  • The water supply facilities of Korea have achieved a rapid growth, along with the other social infrastructures consisting a city, due to the phenomenon of urbanization according to economic development. Meanwhile, the level of water supply service demanded by consumer is also steadily getting higher in keeping with economic growth. However, as an adverse effect of rapid growth, the quantity of aged water supply pipes are increasing rapidly, Bursts caused by pipe aging brought about an enormous economic loss of about 6,161 billion won as of 2019. These problems are not only worsening water supply management, also increasing the regional gap in water supply services. The purpose of this study is to classify hazard evaluation indicators and to rank the water distribution network hazard by cluster using the TOPSIS method. In conclusion, in this study, the entropy-based multi-criteria decision-making methods was applied to rank the hazard management of the water distribution network, and the hazard management ranking for each cluster according to the water supply conditions of the county-level municipalities was determined according to the evaluation indicators of water outage, water leakage, and pipe aging. As such, the hazard ranking method proposed in this study can consider various factors that can impede the tap water supply service in the water distribution network from a macroscopic point of view, and it can be reflected in evaluating the degree of hazard management of the water distribution network from a preventive point of view. Also, it can be utilized in the implementation of the maintenance plan and water distribution network management project considering the equity of water supply service and the stability of service supply.

A study on the effects of Friction loss of CPVC pipe according to Roughness coefficient in a sprinkler system (스프링클러 시스템에서 조도계수에 따른 CPVC 배관 마찰손실 영향의 연구)

  • Kang, Ung Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.355-362
    • /
    • 2016
  • The pipe material is selected according to the physical and chemical properties of the fluid flowing within it. Because the fluid used in fire extinguish systems is water, the various foreign substances dissolved in it cause scale to form on the pipe wall and accelerate the corrosion and aging of the pipe itself. This results in an increase in the friction loss and eventually degrades the efficiency of the pump. The use of CPVC (Chlorinated Poly-Vinyl Chloride) pipes was confirmed to reduce the friction loss compared to conventional steel pipes in the design and construction stages. The friction loss was found to be 76.64MPa with a C-value of 120 for the steel pipe and 50.72 MPa with a C-value of 150 for the CPVC pipe in an actual apartment construction environment. It was confirmed that the friction loss was improved by about 34% when using the CPVC pipe. When the steel and CPVC pipes were employed in the construction, the construction costs were 1,585,158 and 931,842 won, respectively. Therefore, it was shown that the construction cost was reduced by about 41%. We investigated the safety of the fire extinguishing system and the improvement in the economic performance due to the reduction in the total installed capacity by studying practical applications in the field.

Hybrid Photovoltaic/Thermal Solar System with Pulsating Heat Pipe Type Absorber (진동형 히트파이프 흡열판이 결합된 하이브리드 태양광/열 시스템)

  • Kim, Chang-Hee;Jeon, Dong-Hwan;Kong, San-Gun;Kim, Jong-Su
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2148-2153
    • /
    • 2007
  • The electricity conversion-efficiency of solar cell for commercial application is about 6-15%. More than 85% of the incoming solar energy is either reflected or absorbed as heat energy. Consequently, the working temperature of the photovoltaic cells increases considerably after prolonged operations and the cell's efficiency drops significantly. PV/T refers to the integration of a PV module and a solar thermal collector in a single piece of equipment. By cooling the PV module with a fluid steam like air or water, the electricity yield can be improved. At the same time, the heat pick-up by the fluid can be to support space heating or service hot-water systems. In this study, a pulsating heat pipe solar heat collector was combined with single-crystal silicon photovoltaic cell in hybrid energy-generating unit that simultaneously produced low temperature heat and heat and electricity. This experiment was investigating thermal and electrical efficiency for evaluation of a PV/T system.

  • PDF

A Study on a Leakage Sensing Pipe and Monitoring System Using TDR in GIS (GIS상에서 TDR을 사용한 누수감지관과 모니터링 시스템에 관한 연구)

  • 강병모;홍인식
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.4
    • /
    • pp.567-578
    • /
    • 2004
  • GIS technique enhanced a space data manipulation ability and we are offering a geographic information service through various analysis. The quantity used of the water was increased in such situation according to a population increase and a city concentration phenomenon. But, to secure clear water are difficult, owing to the water shortage phenomenon, seepage and the quality of water change for worse. We decide the seepage and the system to retrieve the seepage location using GIS in order to reduce vast loss from the seepage. In this paper we proposed Leakage Sensing System using TDR technology in GIS, constructed a GIS database and pilot system to prove the validity, and simulated it using TDR in GIS.

  • PDF

A study on the economical life of large-diameter water pipe: case study in P waterworks (대구경 상수도관로의 경제적수명 산정 연구: P상수도 사례연구)

  • Kim, Kibum;Seo, Jeewon;Choi, Taeho;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.1
    • /
    • pp.37-45
    • /
    • 2018
  • This study develops a model to estimate the economic life of the large-diameter water supply pipeline in Korea by supplementing existing methods used to perform similar calculations. To evaluate the developed methodology, the model was applied to the actual target area with the conveyance pipe in P waterworks. The application yielded an economic life computation of 39.7 years, considering the cost of damages, maintenance, and renewal of the pipeline. Based on a sensitivity analysis of the derived results, the most important factor influencing the economic life expectancy was the predicted failure rate. The methodology for estimating the economic life of the water supply pipeline proposed in this study is one of the core processes of basic waterworks facility management planning. Therefore, the methods and results proposed in this study may be applied to asset management planning for water service providers.

A Study on the Application of Phased Array Ultrasonic Testing to Main Steam Line in Nuclear Power Plants (원전 주증기배관 웰더렛 용접부 위상배열초음파검사 적용연구)

  • Lee, Seung-Pyo;Kim, Jin-Hoi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.40-47
    • /
    • 2011
  • KSNPs(Korea Standard Nuclear Power Plant) have been applied the break exclusion criteria to the high energy lines passing through containment penetration area to ensure that piping failures would not cause the loss of containment isolation function, and to reduce the resulting dynamic effects. Systems with the criteria are the Main Steam system, Feed Water system, Steam Generator Blowdown system, and Chemical & Volume Control system. In accordance with FSAR(Final Safety Analysis Report), a 100% volumetric examination by augmented in-service inspection of all pipe welds appled the break exclusion criteria is required for the break exclusion application piping. However, it is difficult to fully satisfy the requirements of inspection because 12", 8" and 6" weldolet weldments of Main Steam pipe line have complex structural shapes. To resolve the difficulty on the application of conventional UT(Ultrasonic Testing) technique, realistic mock-ups and UT calibration blocks were made. Simulations of conventional UT were performed utilizing CIVA, a commercial NDE(Nondestructive Examination) simulation software. Phased array UT experiments were performed through mock-up including artificial notch type flaws. A phased array UT technique is finally developed to improve the reliability of ultrasonic test at main steam line pipe to 12", 8" and 6" branch connection weld.

Development of Fin Expansion Type Cooling System using Heat Pipes for LED Lightings (히트파이프를 적용한 LED조명용 핀확장형 냉각시스템 개발)

  • Jung, T.S.;Kang, H.K.
    • Transactions of Materials Processing
    • /
    • v.21 no.2
    • /
    • pp.131-137
    • /
    • 2012
  • With the advantages of power savings, increased life expectancy and fast response time over traditional incandescent bulb, LEDs are increasingly used for many applications including automotive, aviation, display, and special lighting applications. Since the high heat generation of LED chips can reduce service life, degrade luminous efficiency, and cause variation of color temperature, many studies have been carried out on the optimization of LED packaging and heat sinks. In this study, a fin expansion type cooling device using heat pipe, instead of a solid aluminum heat sink, was designed for LED security lightings based on thermal resistance analysis. Numerical analysis and experimental validation were carried out to evaluate its cooling performance.

New Design of Cap Type Filter for Oil Mist Removal (미세 분무유 제거를 위한 신개념 특수필터 설계)

  • Kim, Hong-Gun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.1
    • /
    • pp.13-16
    • /
    • 2011
  • It is a tendency where the number of the restaurant is increasing recently with advancement of the food service industry. In comparison, Noxiousness fine MIST and the removal are passively done in about offensive odor which occurs meat products processing as emitting like that in the atmosphere. Because adherence lamination in the exhaustion line pipe has need of a periodic cleaning and change, it must discontinue the business of long time. In this paper, The technique development on fine MIST, dust of offensive odor and filtering which occur meat products processing prevents adherence/lamination of fine MIST in exhaustion line pipe. And the source prevents the environmental matter which is emitted in the atmosphere under maximizing boil offensive odor and the filtering effect of noxiousness MIST.