• Title/Summary/Keyword: service pipe

Search Result 170, Processing Time 0.025 seconds

Development of Three-Way Proportional Control Valve and Performance Study (3방 비례제어 조절밸브 개발 및 성능 연구)

  • Lee, Jonghwa;Jung, Taeksu;Cho, Chongdu;Kim, Jooyong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.218-223
    • /
    • 2014
  • Korea District heating corp. recently give an attention to combine the district heating and supply pipes as a two pipe system that are in the present system separated with room heating and warm water supply pipe, and the two pipe system is commonly applied for heating service in European countries. In the new two pipe system, only one heat source is supplied to a house and partitioned into room heating and warm water supply by household substation. So the effective distribution of supplied heat source in accordance to user intention is very important. This paper presents the development and performance test of three-way proportional control valve for a combined heat source system in district heating. The proposed valve is controlled to partition heat source into two different directions : hot water distributor for space heating and household substation for warm water supply in response to the pressure drops of tap water caused by the user. The performance investigation is shown within 3% of error compared to the theoretical model of the three-way proportional valve and its controllability is verified.

Safety analysis and deterioration evaluation of water pipe for improvement according to service year (상수도관의 개량을 위한 시간에 따른 노후도 및 안전성 분석)

  • Kwon, Hyuk Jae;Lee, Kyung Je
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.8
    • /
    • pp.589-597
    • /
    • 2021
  • In this study, corrosion depth equation was suggested according to real measured corrosion data, and then management indexes of pipe network which can determine the deterioration rate and safety rate has been established and applied to real pipe networks. Furthermore, reliability analysis and management index analysis have been conducted to estimate and compare the deterioration rate. From the results of reliability analysis, it was found that probability of failure of 200 mm steel pipe can be increased from 4.36% at present time to 8.23% after 20years at Gaduk and from 7.35% to 12.99% at Nami. From the results of management index analysis, it was found that deterioration rates of Gaduk and Nami are 1.009 and 1.174, respectively. Priority of improvement and replacement of water pipe can be determined by results of reliability analysis and management index analysis.

Distribution and Risk Assessment of Bisphenol-A in Tap Water from Rehabilitated Indoor Water Service Pipe (갱생 옥내급수관 수돗물에서 비스페놀-A 분포 및 위해성 평가)

  • Jeong, Gwanjo;Son, Boyoung;Lee, Inja;Ahn, Chihwa;Kim, Junil;Moon, Boram;Lee, Suwon;Ahn, Jaechan;Kim, Bogsoon;Chung, Deukmo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.7
    • /
    • pp.371-376
    • /
    • 2016
  • In this study, the survey of bisphenol-A in indoor water service pipes rehabilitated with epoxy resin was conducted and the risk assessment was done to investigate the effect on the human health to drink tap water. Bisphenol-A in raw water was detected in a range of 50~118 ng/L in all samples, where the limit of quantification was 10 ng/L. This is caused by inflow of the sewage effluent or the tributaries of the surrounding area containing bisphenol-A. Bisphenol-A was not detected in finished water after the advanced water treatment process. It was achieved by its removal from the processes of flocculation-precipitation and oxidation of ozone and chlorine and by being changed to other by-product materials. For the indoor water service pipe, bisphenol-A was not detected in all cases which was not coated with epoxy resin. However, when epoxy resin is lined within the indoor water service pipe, bisphenol-A was identified at maximum level of 521 ng/L and was detected above the limit of quantitation at 68 percentages of all samples. The Hazard Quotient (HQ) at the maximum level (521 ng/L) of the detected bisphenol-A is 0.004, which is less than the reference value of 0.1 for the tap water intake. Therefore, it is considered that the detected levels of bisphenol-A in this study would be safe to drink tap water.

An Experimental Study on Piping Feasibility of PE Compound Pipe for Fire Protection Service (PE 이종강관의 소방용 배관 적용성에 관한 실험적 연구)

  • Park, Jeong-Hwa;Oh, Cheon-Young;Kwark, Ji-Heon;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.55-61
    • /
    • 2016
  • In this study, to determine whether it is possible to apply Polyethylene (PE) compound pipe, which was developed to solve the problem caused by the corrosion of the fire protection piping currently in usein water based fire extinguishing systems, we performed an actual mockup fire test. Since no test standard was available related to the developed compound pipe, we compared and analyzed domestic and international technical materials and test standards and selected suitable fire test standards to evaluate the performance of the PE compound pipe. we applied two fire test standards to the PE compound pipe, viz. those for CPVC and metallic pipes, and conducted a total of 6 experiments to evaluate its performance. According to the results of the first and second fire tests based on the test standard for the CPVC pipe, neither the fitting nor the piping was damaged or deformed and no leakage was observed in the pressure test, which was performed for 5 minutes. For the fire test based on the metallic pipe test standard, a total of 4 experiments were conducted. The first two experiments were conducted to simulate the wet piping system. In the results of this fire test, neither leakage nor rupture was observed from the PE compound pipe and no damage was caused, such as the secession of the PE material. However, in the next two experiments, which simulated the dry system, the PE compound pipe suffered damage and rupture, including deformation before the fire fighting water was discharged. Therefore, we found that the piping performance of the PE compound pipe did not undergo any deterioration, including fusion, deformation, or damage, in the wet piping system simulated fire test.

Three-Dimensional Flow Analysis of Catalytic Converter for Reducing Emission (배출물 저감을 위한 촉매변환기 내의 3차원 유동해석)

  • 정수진;김우승
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.55-65
    • /
    • 1998
  • A numerical and experimental study of three-dimensional steady incompressible non-reacting flow inside various dual-monolith catalytic converters has been conducted for achievement of performance improvement, reduction of light-off time and longer service life by improving the flow uniformity within the monolith. In this study, the effects of curvature of inlet exhaust pipe and monolith brick length on the flow uniformity and pressure drop within monolith were numerically investigated. The computations are confirmed by measurements of steady flow. The agreement between computations and experiment was relatively good. The result of this study shows that curvature of inlet exhaust pipe and monolith brick length gave a great effect on the flow uniformity and the shorter the brick length, the lower flow uniformity and the less pressure drop.

  • PDF

A Numerical Study on the Dynamic Characteristics of Water Hammer Arresters for Building Service Applications (건축설비용 워터햄머흡수기의 동특성에 관한 수치 연구)

  • 노승환;차동진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.4
    • /
    • pp.269-277
    • /
    • 2002
  • Dynamic characteristics of water hammer arresters installed in a building water supply system have been investigated numerically by utilizing a commercial rode that employs the method of characteristics. Some preliminary results with those arresters produced in this study agree well with the previously reported. Then, the arresters have been incorporated into a water supply pipe system of a $59m^2$ apartment unit constructed by a leading construction company, and their dynamic characteristics, especially on the reduction in the water hammer pressure, are investigated. It is found that the setting of the arresters in the pipe system, which is recommended by the company, may not be proper for reducing the pressure to less than 1082.0 kPa when buick-closure valves in the pipe system are closed within 30 ms at the static pressure of 542.6 kPa. More arresters in the system may be required to meet a pressure criteria.

Development and Revenue Service of Propulsion System Using Integrated Stack(PEM) and Heat Pipe (일체형 스택(PEM) 및 냉각장치를 적용한 전동차 추진제어장치 개발 및 상용화)

  • Gim, Myung-Han;Lee, Gwang-Guk;Park, Su-Yong
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.680-685
    • /
    • 2007
  • Power semiconductor which is adapted in the rolling stock has a high practicality for capacity of high voltage and high speed switching. but it has a trouble of fever cause of high speed On, Off switching loss and the operating junction temperature is limited to $150^{/circ}C$ because is made from the silicon for the foundation material. Therefore, it is important to find a way out of this trouble and must make the countermeasure. In this research, the caloric value of the integrated PEM is calculated to adapt the optimized heat pipe and the reliability of the heat pipe is demonstrated through the cooling performance test and vibration test.

  • PDF

Development of Portable Vibration Signal-Based Pipe Wall Thinning Inspection Device (진동신호기반 배관감육 측정시스템 개발)

  • Han, Soon-Woo;Park, Jin-Ho;Kang, To;Sohn, Ki Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.545-547
    • /
    • 2014
  • The portable vibration signal-based pipe wall thinning inspection device was developed in this work. Compared to wall-thinning detection using conventional ultrasonic thickness measurement gauge, the proposed device can estimate average wall thickness of wide range and be applied to in-service pipes. The measurement principle of the device was briefly described and the configrations of hardware and software were explained. It was shown that the device can gauge average wall-thickness of test specimens with high precision.

  • PDF

A Numerical Study on the Reduction of Water Hammering in a Simple Water Supply Pipe System

  • Lim, Ki-Won;Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.51-61
    • /
    • 2001
  • A numerical study has been conducted to characterize the transient pressure in a simple water supply pipe system with an air chamber by utilizing a commercial code that employs the method of characteristics. Some results produced for validation in the study agree quite well with the previously reported. Several parameters are than varied. Among them are the valve closure time, the wave speed, the static pressure, the polytropic exponent, the air chamber volume, the diameter and the shape of orifice in the air chamber, etc, while the water temperature and velocity are kept constant at $20^\circ{C}$ and 0.8m/s, respectively. Results reported in this parametric study may be useful to understand the unsteady behavior of the system.

  • PDF

Infection control among dental hygienists according to infection control education experiences (치과위생사의 감염관리 교육경험에 따른 감염관리 실태)

  • Kim, Ji-Hyun;Kim, Jin-Kyoung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.4
    • /
    • pp.547-556
    • /
    • 2011
  • Objectives : The purpose of this study was to examine the relationship between the infection control education experiences of dental hygienists and the state of their infection control. Methods : The subjects in this study were the dental hygienists who worked in Seoul. The relationship of their infection control education experiences to their gender, marital status, academic credential, workplace, length of service, infection control implementation, experience of being exposed to infection, way of coping with it, hand washing, use of personal protection devices and equipment management was analyzed. Results : It is found that the variable to affect the state of infection control was educational experiences about handpiece water pipe management, ultrasonic scaler water pipe management and three-way syringe water pipe management. Conclusions : Dental hygienists who are one of major dental personnels should receive systematic education on infection control to acquire accurate knowledge to ensure the successful prevention of cross infection.