Comparative Study on the Standards of Internal and External Materials of Each Country for Fire Safety of Buildings (건축물의 화재안전설계를 위한 각국의 내·외장재 기준 비교 연구)

  • Huh, Ye-Rim;Kim, Yun-seong;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.170-171
    • /
    • 2021
  • In Korea, the concentration of cities has led to the high-rise and deep-rise of buildings. In the case of such high-rise buildings, there is a high risk of fire, and the number of internal fires expanding to the outside continues to increase. The Korean Building Act continues to change the ban on combustible exterior materials, and combustible exterior materials are currently not available for buildings with three stories or more than 9 meters, and detailed test standards for finishing materials are also strengthened after the Ulsan residential and commercial fires in 2020. However, the path of fire in the actual building is through a series of processes in which the fire in the compartment grows internally and expands through openings supplied with ventilation factors. Therefore, other than just external materials, design criteria for embedded materials also need to be established. The purpose of this study is to compare standards for internal and external materials at home and abroad and to secure basic data for fire safety design of buildings based on them.

  • PDF

Effects of taper and set-back on wind force and wind-induced response of tall buildings

  • Kim, Yongchul;Kanda, Jun
    • Wind and Structures
    • /
    • v.13 no.6
    • /
    • pp.499-517
    • /
    • 2010
  • Advances in structural materials and construction methods have resulted in flexible and light tall buildings, making an assessment of structural safety during strong wind and serviceability/habitability during comparable medium/weak wind important design criteria. So far, lots of studies on suppressing the wind-induced responses have been carried out for tall buildings with aerodynamic modification. Most of the studies on aerodynamic modification have forced on the corner modification, while the studies on taper and set-back are limited. Changes of sectional shape through taper and set-back can modify the flow pattern around the models, encouraging more 3-dimensionalities, which results in reducing the wind-induced excitations. This paper discusses the characteristics of overturning moments and wind-induced responses of the tall buildings with height variations. The reduction of mean along-wind and fluctuating across-wind overturning moments are apparent in the suburban area than in urban area. A series of the response analyses, the rms displacement responses of the tall buildings with height variations are reduced greatly, while the rms acceleration responses are not necessarily reduced, showing dependences on wind direction.

A Study on the Weighting of Fire Safety Attributes for Fire Risk Assessment in Historic Buildings - Focused on NakSansa- (역사적 건축물 화재위험성 평가를 위한 화재안전속성의 중요도분석 연구 - 낙산사를 중심으로 -)

  • Lee, Ji-Hee
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.189-196
    • /
    • 2012
  • Fire is one of the greatest threats to historical buildings not only to the building's occupants but also to the building's structure and contents. The purpose of this research is to evaluate fire risk in historical buildings in Korea through a series of survey and review. In this research, a multicriteria decision-making approach involving Analytical Hierarchy Process has been designed to determine a weighted index to identify factors and quantify fire risk. Fire risk ranking systems of historical building has been developed in some applications, for example, BOCA, WISCONSIN, FSES and HFRI. According to the such derived fire risk indexing, the Human Activity index showed the highest risk, followed by Historic Buildings, Fire Safety Systems, and then Natural Environmental Causes. Comparison of these factors indicates that the derived risk values differ from case to case. It is proposed that a performance-based design approach should consider the building & occupant characteristics, locations and historical significance, resulting in a more accurate and effective evaluation of fire risk.

Numerical investigation of potential mitigation measures for poundings of seismically isolated buildings

  • Polycarpou, Panayiotis C.;Komodromos, Petros
    • Earthquakes and Structures
    • /
    • v.2 no.1
    • /
    • pp.1-24
    • /
    • 2011
  • During very strong earthquakes, seismically isolated buildings may experience large horizontal relative displacements, which may lead to poundings if an insufficiently wide clearance is provided around the building. This paper investigates, through numerical simulations, the effectiveness of using rubber bumpers, which could be attached at locations where it is likely to have impacts, in order to act as shock-absorbers. For the simulation of the dynamic behavior of such rubber bumpers during impacts, a nonlinear force-based impact model, which takes into account the finite thickness of the rubber bumpers, has been developed. Subsequently, a series of parametric analyses are performed to assess the effect of the gap size, the earthquake characteristics and the thickness, compressive capacity and damping of the bumpers. The stiffness of the moat wall is also parametrically considered during poundings of a seismically isolated building, as another potential mitigation measure for poundings of seismically isolated buildings.

Numerical Simulation of Flow and Dispersion Around Buildings using CFD Model

  • Ryu, Chan-Su
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.2
    • /
    • pp.117-125
    • /
    • 2000
  • A series of simulations were carried out to test the accuracy of a CFD (Computational Fluid Dynamics) model for flow and dispersion problems around buildings. The basic equations involved are Reynolds-averaged Navier-Stokes equations. Two different cases were selected to estimate the accuracy of a CFD model. Case 1 adopted Euler equations, which are obtained by neglecting the viscous fluxes, which can be closed by the $textsc{k}$-$\varepsilon$model for a turbulent close problem. The results of both cases were compared with wind tunnel data. The results for Case 2 were closer to the wind both cases were compared with wind tunnel data. The results for Case 2 were closer to the wind tunnel data than Case 1. Accordingly, this indicates that the inclusion of viscous fluxes in a CFD model is required for the simulation of flow and 야spersion around buildings.

  • PDF

A Study on cost expenditure characteristics and importance level of each maintenance item of public office buildings by conducting cost surveys (공공업무시설의 수선비 조사를 통한 연차별 비용변화 패턴 및 수선비 항목별 발생빈도와 평균비용 분석)

  • Choi, Seok Kyoo;Kim, Gap Youl
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.111-118
    • /
    • 2008
  • To maintain the public office buildings, the related government employee uses cost under the limited budget. it is difficult to execute the budget as is assigned to maintenance items with contemplating the characteristics such as frequency, cost/item, weighting factor, and etc. As a precedent study about this cost-efficiency model, this study is intended to show the expenditure trends, frequencies, and cost distributions of maintenance items for the development of cost-efficiency model by analyzing time series data from the surveys on maintenance costs of the selected public office buildings.

The ASHRAE Design Guide for Tall, Supertall and Megatall Building Systems

  • Simmonds, Peter
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.4
    • /
    • pp.311-318
    • /
    • 2015
  • The ASHRAE Design Guide for Tall, Supertall and Megatall Building Systems was produced in collaboration with the CTBUH. The design guide outlines various tall building mechanical systems that are presently being designed or are planned for the future. Tall commercial buildings in particular present a series of design problems that set them apart from other functions. The Design Guide will be of interest to owners, architects, structural engineers, mechanical engineers, electrical engineers and other specialized engineers and consultants. This design guide addresses design issues for tall commercial buildings, which are very often mixed-use, and commonly consist of low level retail, office floors, residential units, and hotel uses.

Distribution of Wind Pressure on Claddings of Apartment Buildings Affected by Neighboring Buildings (아파트 건축물 군(群)에 의한 건축물 외장재의 풍압분포)

  • Cho, Kang-Pyo;Hong, Sung-Il;Kim, Won-Sool
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.1 s.19
    • /
    • pp.91-99
    • /
    • 2006
  • This paper presents wind pressure distribution on high-rise apartment buildings through wind-tunnel tests. In order to investigate wind-induced interference efforts on building claddings an apartment complex, which was damaged on the claddings during typhoon attack, was exampled and constructed as a scaled model. A series of wind tunnel tests using pressure models were performed in a boundary layer wind tunnel. The test results with and without interfering buildings were compared and discussed. It is observed that the wind pressure on buildings 105 and 106 with surrounding buildings shows highly negative, while the pressure without surrounding buildings were positive. Therefore the wind-induced interference effects should be taken into account in the design of claddings through wind-tunnel tests.

  • PDF

A PRELIMINARY STUDY OF EFFECT OF THE GREEN FEATURE - WING WALLS ON NATURAL VENTILATION IN BUILDINGS

  • Cheuk Ming Mak;Jian Lei Niu;Kai Fat Chan
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.814-819
    • /
    • 2005
  • There is growing consciousness of the environmental performance of buildings in Hong Kong. The Buildings Department, the Lands Department and the Planning Department of the Hong Kong Government issued the first of a series of joint practice notes [1] to promote the construction of green and innovative buildings. Green features are architectural features used to mitigate migration of noise and various air-borne pollutants and to moderate the transport of heat, air and transmission of daylight from outside to indoor environment in an advantageous way. This joint practice note sets out the incentives to encourage the industry in Hong Kong to incorporate the use of green features in building development. The use of green features in building design not only improves the environmental quality, but also reduces the consumption of non-renewable energy used in active control of indoor environment. Larger window openings in the walls of a building may provide better natural ventilation. However, it also increases the penetration of direct solar radiation into indoor environment. The use of wing wall, one of the green features, is an alternative to create effective natural ventilation. This paper therefore presents a preliminary numerical study of its ventilation performance using Computational Fluid Dynamics (CFD). The numerical results will be compared with the results of the wind tunnel experiments of Givoni.

  • PDF

Aerodynamic measurements of across-wind loads and responses of tapered super high-rise buildings

  • Deng, Ting;Yu, Xianfeng;Xie, Zhuangning
    • Wind and Structures
    • /
    • v.21 no.3
    • /
    • pp.331-352
    • /
    • 2015
  • A series of wind tunnel tests were conducted on tapered super high-rise buildings with a square cross section by applying synchronous pressure measurement technology. The effects of global strategy of chamfered modification on aerodynamic loads and wind-induced responses were investigated. Moreover, local aerodynamic strategies of opening a ventilation slot in the corner of equipment and refuge floors were carried out. Results show that the global strategy of tapered elevation increased the vortex shedding frequency, but reduced vortex shedding energy, leading to reduction of across-wind aerodynamic loads and responses. Chamfered modification suppressed the across-wind vortex shedding effect on tapered buildings. Opening the ventilation slot further suppressed the strength of vortex shedding and reduced the residual energy related to vortex shedding in aerodynamic loads of chamfered buildings. Finally, the optimized locations of local aerodynamic strategies were suggested.