• Title/Summary/Keyword: separation of chromium(III) and chromium(VI)

Search Result 5, Processing Time 0.021 seconds

Separation and analysis of Cr(III) and Cr(VI) using 8-hydroxyquinoline complexation of Cr(III) (8-Hydroxyquinoline을 이용한 크롬 3가 및 6가의 분리 및 분석)

  • Lim, Heon-Sung;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.246-250
    • /
    • 2007
  • The quantitative determination of chromium(VI) by separation from chromium(III) complex of 8-hydroxyquinoline using solvent extraction has been studied. The reaction conditions for chromium(III) complex of 8-hydroxyquinoline and the solvent extraction of complex were investigated in detail. The chromium(III) complex was extracted with organic solvent (n-hexane) and residual chromium(VI) was determined by ICP-AES in aqueous layer. This technique is quantitative in the pH range of 8-9 and the limitations such as interfering ions were discussed.

New Analytical Method to Identify Chromium Species, Cr(III) and Cr(VI), and Characteristic Distribution of Chromium Species in the Han River (한강수계해서의 크롬(III,VI) 종(species) 분포 및 분석방법 정립)

  • Jeong, Gwan-Jo;Kim, Dok-Chan;Park, Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.590-598
    • /
    • 2005
  • An adequate method to identify chromium separation, Cr(III) and Cr(VI), in water samples were studied by using High Performance Liquid Chromatography(HPLC) coupled with Inductively Coupled Plasma Mass Spectometer(ICP-MS) equipped with Dynamic Reaction Cell(DRC). The characteristic distribution of Cr(III) and Cr(VI) in the raw water taken at the six water intake stations in Seoul, was analyzed by the method developed by the authors. The chromium species separated by HPLC was isocratically conducted by using tetrabutylammonium phosphate monobasic(1.0 mM TBAP), ethylenediaminetetraacetic acid(0.6 mM EDTA) and 2% v/v methanol as the mobile phase. 5% v/v methanol was used as flushing solvent. A reactive ammonia($NH_3$) gas was used to eliminate the potential interference of $ArC^+$. Several Parameters such as solvent ratio, pH, flow rate and sample injection volume were optimized for the successful separation and reproducibility. Although it has been reported thai the separation sensitivity of Cr(III) is superior to that of Cr(VI), the authors observed Cr(VI) was more sensitive than Cr(III) when ammonia($NH_3$) gas was used as the reaction gas. It took less than 3 minutes to analyze chromium species with this method and the estimated detection limits were $0.061\;{\mu}g/L$ for Cr(III) and $0.052\;{\mu}g/L$, for Cr(VI). According to the results from the analysis on chromium species in the raw water of the six intake stations, the concentrations of Cr(III) ranged from 0.048 to $0.064\;{\mu}g/L$(ave. $0.054\;{\mu}g/L$) while that of Cr(VI) ranged from 0.014 to $0.023\;{\mu}g/L$(ave. $0.019\;{\mu}g/L$). Recovery ratio was very high($90.1{\sim}94.1%$). There were two or three times more Cr(III) than Cr(VI) in the raw water.

Speciation of Chromium in Water Samples with Homogeneous Liquid-Liquid Extraction and Determination by Flame Atomic Absorption Spectrometry

  • Abkenar, Shiva Dehghan;Hosseini, Morteza;Dahaghin, Zohreh;Salavati-Niasari, Masoud;Jamali, Mohammad Reza
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.10
    • /
    • pp.2813-2818
    • /
    • 2010
  • A novel method was developed for the speciation of chromium in natural water samples based on homogeneous liquid-liquid extraction and determination by flame atomic absorption spectrometry (FAAS). In this method, Cr(III) reacts with a new Schiff's base ligand to form the hydrophobic complex, which is subsequently entrapped in the sediment phase, whereas Cr(VI) remained in aqueous phase. The Cr(VI) assay is based on its reduction to Cr(III) by the addition of sodium sulfite to the sample solution. Thus, separation of Cr(III) and Cr(VI) could be realized. Homogeneous liquid-liquid extraction based on the pH-independent phase-separation process was investigated using a ternary solvent system (water-tetrabutylammonium ion ($TBA^+$)-chloroform) for the preconcentration of chromium. The phase separation phenomenon occurred by an ion-pair formation of TBA and perchlorate ion. Then sedimented phase was separated using a $100\;{\mu}L$ micro-syringe and diluted to 1.0 mL with ethanol. The sample was introduced into the flame by conventional aspiration. After the optimization of complexation and extraction conditions such as pH = 9.5, [ligand] = $1.0{\times}10^{-4}\;M$, [$TBA^+$] = $2.0{\times}10^{-2}\;M$, [$CHCl_3$] = $100.0\;{\mu}L$ and [$ClO_4$] = $2.0{\times}10{-2}\;M$, a preconcentration factor (Va/Vs) of 100 was obtained for only 10 mL of the sample. The relative standard deviation was 2.8% (n = 10). The limit of detection was sufficiently low and lie at ppb level. The proposed method was applied for the extraction and determination of chromium in natural water samples with satisfactory results.

Separation of Chromium(III) and Chromium(VI) by Carboxymethylated Polyamine-Polyurea Resin Column (카르복시메틸화된 폴리아민-폴리우레아 수지관에 의한 3가와 6가 크롬의 분리)

  • Chung, Yong Soon;Lee, Kang Woo;Hwang, Jong Youn;Lee, Yong Moon
    • Analytical Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.205-211
    • /
    • 1994
  • Acetic acid and succinic acid bonded polyamine-polyurea(CPPI and SAPPI) resins were synthesized from the reaction of polyethylenimine-polymethylenepolyphenylene isocyanate(PPI) resin as matrix polymer and chloroacetic acid and chlorosuccinic acid respectively. These resins were confirmed with infrared spectrometry and elemental analysis. The adsorption characteristics of the chromium(III) and dichromate(or chromate) ions on the resins were studied by measuring distribution coefficients($K_d$) with changing pH of the solution. It was thought that these ions were adsorbed by ion exchange mechanism. Chromium(III) and dichromate ion could be separated with stepwise elution method by changing pH of the eluent using SAPPI resin packed column($0.6cm(i.\;d.){\times}10cm(L.)$). Also, dichromate ion could be preconecntrated with CPPI resin column by a concentration factor of 50.

  • PDF

Speciation of Cr(III)/Cr(VI) in Tannery Waste Waters by Using Ion-Exchange Resins

  • Kartal, S.;Tokalloglu, S.;Ozkan, B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.694-698
    • /
    • 2006
  • A method has been described for the chemical speciation, preconcentration and determination of Cr(III) and Cr(VI) species in filtered tannery waste waters by flame atomic absorption spectrometry using ion-exchange resins. Amberlite IR-120($H^+$) strongly acidic cation exchanger and Amberlite IRA-410($CI ^-$) strongly basic anion exchanger resins were used for the separation and preconcentration of Cr(III) and Cr(VI) species, respectively. Optimum condition for preconcentration and speciation was obtained by testing pH of sample and eluent, flow rates of sample and eluent, amount of resins, volume of sample and eluents, and effect of foreign ions. The recommended method has been successfully applied for the preconcentration and determination of chromium species in the dissolved phase of waste water samples collected from a tannery waste water treatment plant in Kayseri, Turkey. The detection limits achieved were 0.73 $\mu$g/L for Cr(III) and 0.81 $\mu$g/L for Cr(VI). Recovery studies showed 99% for Cr(III) and 98% for Cr(VI), for samples spiked with single species.