• Title/Summary/Keyword: separation method of precipitation

Search Result 72, Processing Time 0.023 seconds

Decomposition and Leaching of Bastnasite by Sulfation and Recovery of Cerium Hydroxide from Leached Solution (황산화반응에 의한 불탄산염 희토류광(Bastnasite)의 분해, 침출 및 세륨수산화물의 회수)

  • Yoon, Ho-Sung;Kim, Sung-Don;Kim, Chul-Joo;Kim, Jun-Soo;Han, Choon
    • Applied Chemistry for Engineering
    • /
    • v.9 no.3
    • /
    • pp.407-412
    • /
    • 1998
  • This study was carried out to investigate the optimum leaching conditions for the sulfation and water leaching, and separation of cerium from rare earth elements in leached solution by acid-adjusting method. The optimum conditions for the sulfation and water leaching from bastnasite concentrates are that the equivalent ration of sulfuric acid to concentrates is 2.5, calcination temperature and time are $600^{\circ}C$ and 2 hrs respectively, and the pulp density in the water leaching is 9.1%. The yield of rare earth oxide is about 93% at the above condition. The process of recovery of cerium hydroxide from leached solution by acid-adjusting method was carried out as following steps. The first step is the oxidation of the solution at pH 5 by using twice the equivalent of $H_2O_2$ solution as an oxidant. The second step is the precipitation to obtain cerium complex salt and cerium hydroxide after lowering the solution to pH 2. The last step is the oxidation-precipitation by using equivalent of $H_2O_2$ solution. From these results, it was possible to prepare cerium hydroxide with the yield of 60% and the quality of 80%.

  • PDF

Study of Spin Jig Development for Cleaning of the PCB component (PCB기판 세척용 스핀 지그개발에 관한 연구)

  • Lee, Seung-Chul;Park, Suk-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4736-4741
    • /
    • 2014
  • This study examined PCB component cleaning on a PCB component surface, which has defects of precipitation type washing (existing rinse method), sealant and foreign material formed in the adhesive process that could not be removed easily. The spin jig was developed for PCB component cleaning, in which the PCB component settled down, to solve the conventional problem of the removal of foreign material with the centrifugal force by high speed rotation. The results are as follows. With decreasing fraction defect in PCB component washing, the development and substrate damage decreased by more than 80% according to the abstergent in the rotary type using the centrifugal force in the existing precipitation type. When the base plate showed a large difference with the time to include the process after washing the design using the existing method, easy attachment and separation of the PCB component could be possible. The washing time was enhanced 90% compared to the existing time. The reliability of the security and washing collaboration of the design and stability of the cleaning process could be secured so that there was no phenomenon of secession, the PCB component fixed for a cleansing rotation jig could maintain a fixed force by the centrifugal force. The stability and reliability of the washing process and the defective rate could be improved to less than 1%.

Simultaneous Determination of Doxifluridine and 5-FU in Liver and Intestine Tissue Using LC/MS/MS (LC/MS/MS를 이용한 원숭이 및 비글견의 간 및 장관 조직에서의 Doxifluridine과 대사체 5-FU 동시분석법 개발)

  • Woo, Young-Ah;Kim, Ghee-Hwan;Jeong, Eun-Ju;Kim, Choong-Yong
    • YAKHAK HOEJI
    • /
    • v.52 no.2
    • /
    • pp.93-100
    • /
    • 2008
  • A liquid chromatographic method with tandom spectrometric detection (LC/MS/MS) for the simultaneous determination of doxifluridine and its active metabolite, 5-fluorouracil (5-FU) was developed over the concentration range of $5{\sim}2000$ ng/ml, respectively. Doxifluridine, 5-FU and internal standard, 5-chlorouracil (5-CU), were extracted from liver and intestine tissue via protein precipitation. Acetonitrile was used as the extraction solvent and the supernatant was evaporated and reconstructed in mobile phase. Optimum chromatographic separation was achieved on a Agilent Zorbax $C_{18}$ ($100\;mm{\times}2.1\;mm$, $3.5\;{\mu}m$) column with mobile phase run in isocratic with methanol : water (20 : 80, v/v). The flow rate was 0.2 ml/min with total cycle time of 5 min. The lower limit of quantification was validated at 5.0 ng/ml of liver and intestine tissue, for both doxifluridine and 5-FU, respectively. The intra-day and inter-day precision and accuracy of quality control (QC) samples were <11% coefficient of variation and <7% relative error from theoretical concentration for both analytes. In addition, the special designed stability study was performed, because the metabolism of doxifluridine occurs spontaneously even in ice bath for monkey liver. The stability of doxifluridine in liver and intestine of monkey and beagle dog was compared. It was found that bioanalytical validation could not be performed for the monkey liver; however, beagle dog's liver has relatively low speed of metabolism compared to monkey liver and instead of monkey liver, beagle dog's liver could be used for the validation. Bioanalytical validation could be performed in monkey intestine. Eventually, this developed method for liver and intestine will be useful in support of the toxicokinetic and pharmacokinetic studies of doxifluridine and 5-FU.

Simulation of IgY(Immunoglobulin Yolk) Purification by SMB(Simulated Moving Bed) (SMB(Simulated Moving Bed)를 이용한 IgY(Immunoglobulin Yolk) 분리의 전산모사)

  • Song, Sung-Moon;Kim, In-Ho
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.798-803
    • /
    • 2011
  • IgY(Immunoglobulin Yolk) is a specific antibody in egg yolk, and it protects human body from virus and antigen. There are a lot of egg yolk components such as lipoprotein and protein. To separate IgY, HPLC(High Performance Liquid Chromatography) and precipitation were used in a batch mode and SMB(Simulated Moving Bed) was adopted for continuous purification of yolk proteins. IgY and other proteins in yolk were separated by using three-zone SMB chromatography. Before performing SMB experiments, batch chromatography and PIM(pulse input method) were performed to find operation parameters and adsorption isotherms. The results of batch chromatography were compared with simulated results using Aspen chromatography. To find the most suitable separation condition in SMB chromatography, simulations in $m_2$-$m_3$ plane on the triangle theory were carried out. $m_2$ = 0.18, $m_3$ = 1.0 and ${\Delta}$t = 419 s are the best conditions for the highest purity of IgY. With this operating parameters(flow rate in three zone and switching time), the purity of raffinate results in 98.39% from Aspen chromatography simulation. Most of the simulation reached steadystate within second recycle.

Determination of Unit Hydrograph for the Hydrological Modelling of Long-term Run-off in the Major River Systems in Korea (장기유출의 수문적 모형개발을 위한 주요 수계별 단위도 유도)

  • 엄병현;박근수
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.4
    • /
    • pp.52-65
    • /
    • 1984
  • In general precise estimation of hourly of daily distribution of the long-term run-off should be very important in a design of source of irrigation. However, there have not been a satisfying method for forecasting of stationar'y long-term run-off in Korea. Solving this problem, this study introduces unit-hydrograph method frequently used in short-term run-off analysis into the long-term run-off analysis, of which model basin was selected to be Sumgin-river catchment area. In the estimation of effective rainfall, conventional method neglects the Soil moisture condition of catchment area, but in this study, the initial discharge (qb) occurred just before rising phase of the hydrograph was selected as the index of a basin soil moisture condition and then introduced as 3rd variable in the analysis of the reationship between cumulative rainfall and cumulative loss of rainfall, which built a new type of separation method of effective rainfall. In next step, in order to normalize significant potential error included in hydrological data, especially in vast catchment area, Snyder's correlation method was applied. A key to solution in this study is multiple correlation method or multiple regressional analysis, which is primarily based on the method of least squres and which is solved by the form of systems of linear equations. And for verification of the change of characteristics of unit hydrograph according to the variation of a various kind of hydrological charateristics (for example, precipitation, tree cover, soil condition, etc),seasonal unit hydrograph models of dry season(autumn, winter), semi-dry season (spring), rainy season (summer) were made respectively. The results obtained in this study were summarized as follows; 1.During the test period of 1966-1971, effective rainfall was estimated for the total 114 run-off hydrograph. From this estimation results, relative error of estimation to the ovservation value was 6%, -which is mush smaller than 12% of the error of conventional method. 2.During the test period, daily distribution of long-term run-off discharge was estimated by the unit hydrograph model. From this estimation results, relative error of estimation by the application of standard unit hydrograph model was 12%. When estimating by each seasonal unit bydrograph model, the relative error was 14% during dry season 10% during semi-dry season and 7% during rainy season, which is much smaller than 37% of conventional method. Summing up the analysis results obtained above, it is convinced that qb-index method of this study for the estimation of effective rainfall be preciser than any other method developed before. Because even recently no method has been developed for the estimation of daily distribution of long-term run-off dicharge, therefore estimation value by unit hydrograph model was only compared with that due to kaziyama method which estimates monthly run-off discharge. However this method due to this study turns out to have high accuracy. If specially mentioned from the results of this study, there is no need to use each seasonal unit hydrograph model separately except the case of semi-dry season. The author hopes to analyze the latter case in future sudies.

  • PDF

Estimation of Exploitable Groundwater in the Jinju Region by Using a Distributed Hydrologic Model (분포형 수문모형을 이용한 진주지역의 지하수 개발가능량 추정)

  • Lee, Jeong Eun;Chung, Il-Moon;Lee, Jeongwoo;Kim, Min Gyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.655-662
    • /
    • 2021
  • This study aimed to estimate exploitable groundwater for the sustainable supply of groundwater in the Jinju region of South Gyeongsang Province. As an integrated hydrologic analysis model, SWAT-MODFLOW was used to estimate the distributed groundwater recharge in consideration of land use and soil distribution. As a result of calibration of the model, the coefficient of determination between the observed flow and the simulated flow was 0.75-0.80, which was good. The simulated groundwater recharge rate showed a spatio-temporal distribution due to heterogeneous watershed characteristics. The amount of groundwater recharge shows lower values over winter and spring, but it increases according to the pattern of precipitation in summer and autumn. The calculated average annual groundwater recharge was compared with the result using the baseflow separation method of natural flow, and the deviation of both results was small, within 3 %, confirming the validity of the estimated groundwater recharge. Exploitable groundwater is defined as the amount of recharge corresponding to low flow with 10 years of return period. Therefore, in this study, 14.2 % of the annual precipitation was found to be exploitable as a result of calculating the amount of recharge at a 10-year frequency using a statistical frequency analysis technique.

Development of Protocol for the Effective Detection of Feline Calicivirus as Norovirus Surrogate in Oyster and Lettuce (굴과 상추에서 노로바이러스의 대체모델 feline calicivirus의 효율적 검출법 개발)

  • Lee, Soo-Yeon;Jang, Keum-Il;Woo, Gun-Jo;Kwak, Hyo-Sun;Kim, Kwang-Yup
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.71-76
    • /
    • 2007
  • Foodborne illness caused by Noroviruses (NVs) is increasing rapidly in Korea. This study developed an effective detection protocol for NVs found in contaminated oysters and lettuce through an investigation using the major steps of virus particle separation, concentration and RT-PCR. As a surrogate model for NVs, the cultivable feline calicivirus (FCV) that belongs to the same Caliciviridae family was used. Instead of using a time-consuming ultracentrifugation method, efficient methods based on solvent extraction and PEG precipitation procedure were applied. Direct homogenization of a 25g sample of whole oyster and lettuce in 175mL PBS provided the simplicity that would be needed in the actual field of food product examination. The overnight PEG precipitation step at $4^{\circ}C$ was reduced to 3 h by placing the reaction tube in ice and by adjusting the PEG concentrations. The application of the use of chloroform and 0.2 ${\mu}m$ syringe filtration together showed a better detection efficiency than the use of chloroform alone in removing PCR inhibitors for both oyster and lettuce samples. Also, dilution of the extracted RNA solution before PCR provided increased sensitivity. The improved detection protocol developed in this study could be efficiently applied to detect FCV and most likely NVs from oysters and lettuce.

Facile synthesis of ZnBi2O4-graphite composites as highly active visible-light photocatalyst for the mineralization of rhodamine B

  • Nguyen, Thi Mai Tho;Bui, The Huy;Dang, Nguyen Nha Khanh;Ho, Nguyen Nhat Ha;Vu, Quang Huy;Ngo, Thi Tuong Vy;Do, Manh Huy;Duong, Phuoc Dat;Nguyen, Thi Kim Phuong
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.12
    • /
    • pp.2442-2451
    • /
    • 2018
  • Novel highly active visible-light photocatalysts in the form of zinc bismuth oxide ($ZnBi_2O_4$) and graphite hybrid composites were prepared by coupling via a co-precipitation method followed by calcination at $450^{\circ}C$. The asprepared $ZnBi_2O_4$-graphite hybrid composites were tested for the degradation of rhodamine B (RhB) solutions under visible-light irradiation. The existence of strong electronic coupling between the two components within the $ZnBi_2O_4$-graphite heterostructure suppressed the photogenerated recombination of electrons and holes to a remarkable extent. The prepared composite exhibited excellent photocatalytic activity, leading to more than 93% of RhB degradation at an initial concentration of $50mg{\cdot}L^{-1}$ with 1.0 g catalyst per liter in 150 min. The excellent visible-light photocatalytic mineralization of $ZnBi_2O_4-1.0graphite$ in comparison with pristine $ZnBi_2O_4$ could be attributed to synergetic effects, charge transfer between $ZnBi_2O_4$ and graphite, and the separation efficiency of the photogenerated electrons and holes. The photo-induced $h^+$ and the superoxide anion were the major active species responsible for the photodegradation process. The results demonstrate the feasibility of $ZnBi_2O_4-1.0graphite$ as a potential heterogeneous photocatalyst for environmental remediation.

Development and validation of LC-MS/MS for bioanalysis of hydroxychloroquine in human whole blood

  • Park, Jung Youl;Song, Hyun Ho;Kwon, Young Ee;Kim, Seo Jin;Jang, Sukil;Joo, Seong Soo
    • Journal of Biomedical and Translational Research
    • /
    • v.19 no.4
    • /
    • pp.130-139
    • /
    • 2018
  • This study aimed to analyze a high-performance liquid chromatography (HPLC) separation using a pentafluorophenyl column of parent drug hydroxychloroquine (HCQ) and its active metabolite, desethylhydroxchloroquine (DHCQ) applying to determine bioequivalence of two different formulations administered to patients. A rapid, simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for bioanalysis of HCQ and its metabolite DHCQ in human whole blood using deuterium derivative $hydroxychloroquine-D_4$ as an internal standard (IS). A triple-quadrupole mass spectrometer was operated using electrospray ionization in multiple reaction monitoring (MRM) mode. Sample preparation involves a two-step precipitation of protein techniques. The removed protein blood samples were chromatographed on a pentafluorophenyl (PFP) column ($50mm{\times}4.6mm$, $2.6{\mu}m$) with a mobile phase (ammonium formate solution containing dilute formic acid) in an isocratic mode at a flow rate of 0.45 mL/min. The standard curves were found to be linear in the range of 2 - 500 ng/mL for HCQ; 2 - 2,000 ng/mL for DHCQ in spite of lacking a highly sensitive MS spectrometry system. Results of intra- and inter-day precision and accuracy were within acceptable limits. A run time of 2.2 min for HCQ and 2.03 min for DHCQ in blood sample facilitated the analysis of more than 300 human whole blood samples per day. Taken together, we concluded that the assay developed herein represents a highly qualified technology for the quantification of HCQ in human whole blood for a parallel design bioequivalence study in a healthy male.

Enhancement of phosphate removal using stabilized Fe-Mn particle (Fe-Mn 입자의 안정화를 통한 인산염 효율 향상)

  • Seoyeon Kang;Jeongwoo Shin;Byugnryul An
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.375-382
    • /
    • 2023
  • The binary oxide adsorbent using Fe and Mn (Fe-Mn) has been prepared by precipitation method to enhance the removal of phosphate. Different amounts of chitosan, a natural organic polymer, were used during preparation of Fe-Mn as a stabilizer to protect an aggregation of Fe-Mn particles. The optimal amount of chitosan has been determined considering the separation of the Fe-Mn particles by gravity from solution and highest removal efficiency of phosphate (Fe-Mn10). The application of Fe-Mn10 increased removal efficiency at least 15% compared to bare Fe-Mn. According to the Langmuir isotherm model, the maximum uptake (qm) and affinity coefficient (b) were calculated to be 184 and 240 mg/g, and 4.28 and 7.30 L/mg for Fe-Mn and Fe-Mn10, respectively, indicating 30% and 70% increase. The effect of pH showed that the removal efficiency of phosphate was decrease with increase of pH regardless of type of adsorbent. The enhanced removal efficiency for Fe-Mn10 was maintained in entire range of pH. In the kinetics, both adsorbents obtained 70% removal efficiency within 5 min and 90% removal efficiency was achieved at 1 h. Pseudo second order (PSO) kinetic model showed higher correlation of determination (R2), suggesting chemisorption was the primary phosphate adsorption for both Fe-Mn and Fe-Mn10.