• Title/Summary/Keyword: separation efficiency

Search Result 1,121, Processing Time 0.023 seconds

Labeling Efficiency of $^{99m}Tc$-Labeled RBC Due to Labeling Time Change (표지시간 변화에 의한 $^{99m}Tc$과 적혈구 표지효율)

  • Dong, Kyeong-Rae;Kim, Ho-Seong;Choi, Seong-Kwan
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.259-263
    • /
    • 2007
  • For the preparation of $^{99m}Tc$-labeled RBC, $10{\sim}20\;{\mu}g/kg$ of Stannous(II) chloride and $10{\sim}40\;min$ of preparation was used. For finding out the effect of contrast agent, the blood samples were collected in three days, seven days, and 1 months after the diagnostic procedure. In the normal volunteer, the concentration of reducing agent and preparation time did not effect on the radiochemical yield. But in the patients, 10 mg of Stannous(II) chloride and 60 min incubation times was shown high radiochemical yield. Contrast agent has a significant effect on the radiochemical yield. Although the blood samples which were collected after seven days of diagnostic procedure did not effect on the radiochemical yield of $^{99m}Tc$-labeled RBC, but the radiochemical yield of $^{99m}Tc$-labeled RBC which was prepared with a sample of high concentration of contrast agent in blood led to low radiochemical yield. For these samples, the modified method showed high radiochemical yield than previous in vivo preparation method. The recommended method is followed. Blood collecting was performed at 30 minutes after injection of reducing agent, and it is centrifuged for removal of plasma. After addition of $^{99m}TcO^-_4$, sample reservoir was rotated. After addition of normal saline, and it is centrifuged for separation of saline. Then $^{99m}Tc$-labeled RBC was obtained after removal of saline.

  • PDF

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

Consumer's Behaviors on the Laundering of Baby's Clothing - Comparison of Washing Machine Types - (영.유아복 세탁에 관한 소비자 행동 연구 - 세탁기 유형별 비교 -)

  • Lee, Su-Yeon;Le, Jeong-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.8
    • /
    • pp.1231-1239
    • /
    • 2007
  • The purpose of this study was to investigate consumer's behaviors on the laundering of baby's clothing according to washing machine types. The subjects were 255 consumers with babies(0-2 years) in Korea. The data were collected with a self-administered questionnaire and analyzed by Chi-square test and multiple response analysis, and SPSS 12.0 statistics package was used. Consumers were separated into two groups according to washing machine types with general pulsator type and drum-type. Consumer's behaviors between general pulsator type group and drum-type group of washing machines were also examined. The results of this study were as follows. In the consumer satisfaction for washing machine, mostly drum-type group of consumers were satisfied with their washing machines. As the reasons of washing machine's dissatisfaction, noise, washing time and low washing efficiency were high in the pulsator type group, and washing time, noise and high price in the drum-type washing machine group. The consumers concerned about separation of clothing and laundering label while they washed laundry by washing machine. However, they didn't separate clothing because the small volume of laundry and a long washing time. The most interest and required thing of consumers was complete rinsing without any detergents used in washing as well as the removal of soils for baby's clothing regardless of two washing machine types. And they complained food soils like milk and mother's milk etc. were not completely removed by washing machine. As a whole the washing frequency of baby's laundry was once per a day and the rinsing also more than three times per a laundry. Most of the consumers used a private detergents for baby's clothing(detergents for baby's clothing only), and preferred to the high or boiled temperature washing as a desirable baby's laundering. There were significant differences between general pulsator type group and drum-type group of washing machines on the laundering of baby's clothing in this study.

Efficiency of Silver Ion-Silica Solid Phase Extraction for Elimination of Sulfur Compounds during Pesticide Multiresidue Analysis in Allium Species (파속류의 잔류농약분석과정에서 silver ion-silica solid phase extraction에 의한 황화합물의 제거 효율성)

  • Park, Jin-Woo;Moon, Kyung-Mi;Choi, Young-Whan;Lee, Young-Guen
    • Journal of Life Science
    • /
    • v.20 no.1
    • /
    • pp.60-65
    • /
    • 2010
  • Since organic sulfur compounds respond to GC/ECD sensitively, they interfere with quantitative separation of pesticides during residual pesticide analysis of Allium species. In this study, it was intended to develop a rapid and simple method for pesticide multi-residues analysis through clean-up and interferences by a solid-phase extraction (SPE). An SPE method employing silver nitrate impregnated Florosil cartridge was developed and evaluated for the elimination of sulfur compounds from the test solution of Allium species during pesticide residues analysis. The silver nitrate impregnated Florosil cartridge was prepared by efflux of 3 ml of 20% silver nitrate solution through Florosil cartridge (1 g packing, 6 ml tube). The extracts equivalent to 2, 4 6, and 10 g of each sample were loaded onto the cartridge and allowed to exude, and then the exudations were analyzed by GC/ECD. More than 95% of sulfur compounds were removed from the loaded extracts equivalent, up to 6 g in onion, 4 g in spring onion and 4 g in shallot, respectively. 40 pesticides were spiked in the Allium species and loaded onto the cartridge to determine the recoveries; from this, the recoveries of 34 pesticides were within 70~120%.

Development and Full-scale Application of the Alternative Carbon Source Based on the Substrate Compatibility (미생물 순응 호환성에 기반한 대체탄소원 개발 및 실용화 사례)

  • Jung, In-Chul;Jo, Hyeon-Gil;Lee, Du-Ho;Kang, Dong-Hyo;Lim, Keun-Taek;Lee, Sung-Hak;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.5
    • /
    • pp.491-498
    • /
    • 2005
  • J sewage treatment plant (WWTP) in Busan has used methanol as an external carbon source for the biological denitrification process. Methanol is widely used. but rather expensive and very dangerous in handling. Therefore, it has been required that the economic alternative carbon source must be developed. By-product from a fine chemical industry can be Purified by removing high molecular weight substances using the ultrafilter membrane separation process and RBDCOD fraction becomes $98{\sim}99%$ of COD substances in the purified by-product. The purified by-product containing three types of alcohols, methanol, prophylenglycol and methoxypropanol; showed similar chemical characteristics to the methanol, a main external carbon source, in biodegradation pathway. Shown above, the compatibility between main and alternative carbon sources has been achieved. Also very short or no adaptation period is necessary in the case of exchanging these carbon sources. The compatibility between external carbon sources is an essential element for stabilizing WWTP operations. During the full-scale application test of the by-product, the alternative carbon source line got on par with the treatment efficiency of the methanol line. With the test result, J-WWTP changed methanol to a fine chemical by-product, in two out of three J-WWTP lines. Moreover, it is expected that 55.4% of the external carbon source cost reduction can be achieved in the alternative carbon source applied lines.

A Study on the Sludge Reduction and Biogas Production through a Two-phase Anaerobic Digestion Process (이상 혐기성 소화 공정을 통한 슬러지 발생량 저감과 바이오가스 생산에 관한 연구)

  • Woo, Mi-Hee;Han, Gee-Bong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.9
    • /
    • pp.894-899
    • /
    • 2010
  • We coordinated the experiments with ozone pretreatment and two-phase anaerobic digestion using solid-liquid separation to raise the efficiency of sludge volume reduction and obtained the following results. The pre-treatment with ozone reduced the solid concentration in the average of TSS $8.3{\pm}2.0%$ TSS and $9.2{\pm}}2.8%$ VSS. Of the organic material, TCOD decreased $5.1{\pm}2.4%$, but SCOD showed $72{\pm}6.5%$ increased, which was due to destruction of the cell wall and dissolution of icell media by the powerful oxidative stress of ozone. During the two-phase anaerobic digestion process, we achieved the reduction of $21.5{\pm}3.4%$ TSS, $20.2{\pm}8.4%$ VSS, $32.1{\pm}7.9%$ TCOD and $22.1{\pm}7.2%$ SCOD in average. The maximum methane gas production were 177.6 mL per g TSS, 210.8 mL per g VSS, 127.0 mL per g TCOD and 1452.0 mL per g SCOD, respectively. Solid material reduction through the two-phase anaerobic digestion and MLE (Modified Ludzack-Ettinger) processes were 93.8% of TSS and 92.0% of VSS. We concluded that suggested two-phase anaerobic digestion and MLE process could achieve the reasonable production of biogas and a maximum reduction of the sludge volume.

Extraction of Pigment from Sea Mustard ( Undaiia pinnatinda) using Supercritical Carbon Dioxide and Entrainer (초임계 이산화탄소와 보조용매를 이용한 미역으로부터 색소 추출)

  • HONG Seok-Ki;CHUN Byung-Soo;PARK Sun-Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.3
    • /
    • pp.213-217
    • /
    • 2001
  • In order to develop a new separation technology, supercritical fluid extraction process was used to produce high purity pigments and fatty acids from seaweed (Undaria pinnatifida). Supercritical carbon dioxide was used as a solvent and ethanol as an entrainer. The sample was treated by a frozen drier and experiments were conducted with a semi-batch flow system at various operating conditions (pressure range, $10.3\~17.2$ MPa; temperature range, $30\~45^{\circ}C$: particle size, $500\~1,000{\mu}m$ extraction time, 60 min). Characteristics of the recovered pigment (chlorophyll a) and fatty acids were determined by UV-spectrophotometry and gas chromatography, respectively. The highest extraction efficiency for fatty acids and pigments was achieved at 12.4 MPa, $35^{\circ}C$, $500{\mu}m$of seaweed size.

  • PDF

Comparison of the Quantulus 1220 and 300SL Liquid Scintillation Counters for the Analysis of 222Rn in Groundwater

  • Kim, Hyuncheol;Jung, Yoonhee;Lee, Wanno;Choi, Guen-Sik;Chung, Kun Ho;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.395-401
    • /
    • 2016
  • Background: Liquid scintillation counters (LSCs) are commonly used as an analytical method for detecting $^{222}Rn$ in groundwater because they involve a simple sample pretreatment and allow high throughout with an autosampler. The Quantulus 1220 is the best-selling LSC in Korea, but its production was stopped. Recently, a new type of LSC, the 300SL, was introduced. In this study, the 300SL was compared with the Quantulus 1220 in order to evaluate the ability of each apparatus to detect $^{222}Rn$ in groundwater. Materials and Methods: The Quantulus 1220 and 300SL were used to detect the presence of $^{222}Rn$. Radon gas was extracted from a groundwater sample using a water-immiscible cocktail in a LSC vial. The optimal analytical conditions for each LSC were determined using a $^{222}Rn$ calibration source prepared with a $^{226}Ra$ source. Results and Discussion: The optimal pulse shape analysis level for alpha and beta separation was 80 for the Quantulus 1220, and the corresponding pulse length index was 12 in the 300SL. The counting efficiency of the Quantulus 1220 for alpha emissions was similar to that of the 300SL, but the background count rate of the Quantulus 1220 was 10 times lower than that of the 300SL. The minimum detectable activity of the Quantulus 1220 was $0.08Bq{\cdot}L^{-1}$, while that of the 300SL was $0.20Bq{\cdot}L^{-1}$. The analytical results regarding $^{222}Rn$ in groundwater were less than 10% different between these LSCs. Conclusion: The 300SL is an LSC that is comparable to the Quantulus 1220 for detecting $^{222}Rn$ in groundwater. Both LSCs can be applied to determine the levels of $^{222}Rn$ in groundwater under the management of the Ministry of Environment.

Extraction Equilibria of Acrylic Acid with Amine Extractants (아민계 추출제에 의한 아크릴산의 추출 평형)

  • Lee, Yong Hwa;Lee, Jun;Hong, Yeon Ki
    • Clean Technology
    • /
    • v.20 no.2
    • /
    • pp.103-107
    • /
    • 2014
  • Acrylic acid is a commodity chemical which is applicable for various industries such as polymer and textile industry. Currently, it has been produced by chemical synthesis from petroleum. However, due to the high price of petroleum and global $CO_2$ emission, renewable materials such as sugar are interesting alternative carbon sources for the biological production of acrylic acid. For an economic production of acrylic acid from renewable carbon sources, a cost effective separation process for acrylic acid should be needed. In this study, reactive extraction by TOA (tri-n-octylamine) was used for the recovery of acrylic acid from its aqueous solutions. The effects of polarity of diluents and concentration of TOA on extraction equilibrium were investigated. The extraction efficiency was proportional to concentration of TOA and polarity of diluents and its value was more than 95% in the case of sufficient concentration of TOA. From IR spectroscopy, it was concluded that the ratio of (1,1) acid-amine complex was increased and the ratio of acid dimer was decreased with concentration of TOA. Equilibrium model based on IR spectroscopy was well fitted with experimental data.

Characterization and assessment of the dolomite powder for application as fillers in the marble-type ore (대리암형 백운석의 분체 특성과 충전재로서의 응용성 평가)

  • Noh, Jin-Hwan;Lee, Na-Kyoung
    • Journal of the Mineralogical Society of Korea
    • /
    • v.20 no.2 s.52
    • /
    • pp.71-81
    • /
    • 2007
  • The marble-type dolomite from the Jasung Mine, which was farmed by duplicated affects of contact metamorphism and subsequent hydrothermal alteration, corresponds to a high-purity dolomite ranging up to above 98wt.% in dolomite contents. The dolomite contain minor impurities such as quartz, muscovite, and pyrite. It is characteristic that the dolomite is fairy Fe-rich corresponding to 0.4 wt.% due to the presence of pyrite of possible hydrothermal origin. The dolomite is nearly white-colored and constituting with subhedral crystals ranging $0.35{\sim}0.46mm$M in size, forming equigranular texture. Compared to the typical high-Ca limestone from the Pungchon Formation, the powder characteristics of dolomite is rather superior in milling efficiency, yields of fine particles, and size distribution. In addition, except for iron contents, the dolomite powder is no less superior than the limestone in quality and characteristics as fillers with respects to not only whiteness, oil absorption, and specific surface area but also shape characters such as elongation ratio, aspect ratio, and sphericity. This good characteristics of dolomite powder seem to be originated basically from comparatively higher grade and crystallinity of dolomite. Higher iron contents and the presence of sulfides prevents the dolomite from application for uses by thermal treatment, except for metallic manufacture. However, if proper ore separation procedure is available, the dolomite can be sufficiently utilized as substitutes for high-Ca limestone in most fields of filler industries.