• 제목/요약/키워드: sensitive analysis

검색결과 3,615건 처리시간 0.032초

A Strategy Study on Sensitive Information Filtering for Personal Information Protect in Big Data Analyze

  • Koo, Gun-Seo
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권12호
    • /
    • pp.101-108
    • /
    • 2017
  • The study proposed a system that filters the data that is entered when analyzing big data such as SNS and BLOG. Personal information includes impersonal personal information, but there is also personal information that distinguishes it from personal information, such as religious institution, personal feelings, thoughts, or beliefs. Define these personally identifiable information as sensitive information. In order to prevent this, Article 23 of the Privacy Act has clauses on the collection and utilization of the information. The proposed system structure is divided into two stages, including Big Data Processing Processes and Sensitive Information Filtering Processes, and Big Data processing is analyzed and applied in Big Data collection in four stages. Big Data Processing Processes include data collection and storage, vocabulary analysis and parsing and semantics. Sensitive Information Filtering Processes includes sensitive information questionnaires, establishing sensitive information DB, qualifying information, filtering sensitive information, and reliability analysis. As a result, the number of Big Data performed in the experiment was carried out at 84.13%, until 7553 of 8978 was produced to create the Ontology Generation. There is considerable significan ce to the point that Performing a sensitive information cut phase was carried out by 98%.

감도해석기법을 이용한 구조물의 진동특성 최적화 수법의 실제 기계에의 응용 (The Application of Structural Dynamic Optimization for the Actual Machine U sing Sensitive Analysis Techniques)

  • 박석주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제16권3호
    • /
    • pp.51-57
    • /
    • 1992
  • Authors had analyzed the Press machine's vibrational characteristics by Substructure Synthesis Method. This paper discribes the structural Dynamic Optimization for the machine using Sensitive Analysis Method. The substructure synthesis method and sensitive analysis methods are used for the vibration analysis and structural modification. The results obtained are as follows ; 1. The tooling precision of the press machine is ruled by the bending vibration of the slide. 2. The structural Modification Method for minimizing impact responses is proposed, and modal analysis and sensitive analysis method are introduced to solve it. 3. The impact responses of running machine were reduced to 40% of the unmodified machine by using the proposed method.

  • PDF

The effect of sensitive and non-sensitive parameters on DCGL in probability analysis for decommissioning of nuclear facilities

  • Hyung-Woo Seo;Hyein Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3559-3570
    • /
    • 2023
  • In the decommissioning of nuclear facilities, Derived Concentration Guideline Level (DCGL) derivation is necessary for the release of the facility after the site remediation, which also needs to be implemented in the stage of establishing a decommissioning planning. In order to derive DCGL, the dose assessment for the receptors can be conducted from residual radioactivity by using RESRAD code. When performing sensitivity analysis on probabilistic parameters, secondary evaluation is performed by assigning a single value for parameters classified as sensitive. However, several options may arise in the handling of nonsensitive parameters. Therefore, we compared the results of the first execution of RESRAD applying probabilistic parameters for each scenario with the results of the second execution applying a single value to sensitive parameters among the probabilistic parameters. In addition, we analyzed the effect of setting options for non-sensitive parameters. As a result, the effect on DCGL were different depending on the application scenario, the target radionuclides, and the input parameter selections. In terms of the overall evaluation period, the DCGL graph of the default option was generally shown as the most conservative except for some radionuclides. However, it will not necessarily be given priority in the aspect of the need to reflect site characteristics. The reason for selecting a probabilistic parameter is the availability of the parameter and the uncertainty of applying a single value. Therefore, as an alternative, it can be consistently applied to distribution as an option for non-sensitive parameters after sensitivity analysis.

음성 트래픽을 위한 동적우선권제어방식의 성능분석 (Performance Analysis of a Dynamic Priority Control Scheme for Delay-Sensitive Traffic)

  • 김도규;김용규;조석팔
    • 한국음향학회지
    • /
    • 제19권8호
    • /
    • pp.3-11
    • /
    • 2000
  • 음성의 특성은 지연에 매우 민감한 (delay-sensitive) 트래픽으로 시스템에서 손실에 민감한 (loss-sensitive) 다른 트래픽과 동일한 방식으로 서비스되어서는 두 트래픽 모두의 QoS (Quality of Service)를 만족시킬 수 없다. 효율적인 트래픽의 처리를 위해서는 시스템의 상태에 따라 손실에 민감한 트래픽에 영향을 적게 주면서 지연민감 트래픽의 성능도 만족하는 것이 바람직하다. 본 논문에서 도입한 동적우선권제어함수 (Dynamic Priority Control Function, DPCF)는 시스템의 상태에 따라 각 트래픽에 우선권을 동적으로 할당하여 서비스 스케줄링을 제어하는 함수f(·)로 기존의 우선권 제어방식을 더욱 일반화시킨 방식이다. 클래스 1의 손실민감 트래픽과 음성과 같은 클래스 2의 지연민감 트래픽을 수용하는 시스템에 TBPJ (Threshold-based Bernoulli Priority Jump) 방식의 DPCF을 적용하여 성능을 분석하였다. DPCF은 각 시스템에 대기하고 있는 트래픽의 양과 시스템의 가용 용량인 버퍼의 threshold에 따라 각 트래픽 클래스에 우선권을 동적으로 할당하여 서비스가 이루어지도록 한다. 성능분석을 통하여 TBPJ 제어방식이 기존의 우선권 제어 방식보다 성능 및 효율성에 있어서 우수함을 입증하였다. 즉 성능을 분석한 결과 손실민감 트래픽의 성능저하는 미미하고 지연민감 트래픽의 성능향상은 현저히 개선된 것을 확인하였다.

  • PDF

Synthesis and pH-Dependent Micellization of Sulfonamide-Modified Diblock Copolymer

  • Pal Ravindra R.;Kim Min Sang;Lee Doo Sung
    • Macromolecular Research
    • /
    • 제13권6호
    • /
    • pp.467-476
    • /
    • 2005
  • The main objective of this study was to develop and characterize pH-sensitive biodegradable polymeric materials. For pH-sensitivity, we employed three kinds of moieties: 2-amino-3-(lH-imidazol-4-yl)-propionic acid (H), N-[4-( 4,6-dimethyl-pyrimidin-2ylsulfamoyl)-phenyl]succinamic acid (SM), and 2- {3-[ 4-( 4,6-dimethyl-pyrim­idin- 2-ylsulfamoyl)-phenylcarbamoyl]-propionylamino} -3-(3 H - imidazol-4-yl)-propionic acid (SH). The pH -sensitive diblock copolymers were synthesized by ring opening polymerization and coupling reaction from poly(ethylene glycol) (MPEG), $\varepsilon$-caprolactone (CL), D,L-lactide (LA) and pH-sensitive moieties. The pH-sensitive SH molecule was synthesized in a two-step reaction. The first step involved the synthesis of SHM, a methyl ester derivative of SH, by coupling reaction of SM and L-histidine methyl ester dihydrochloride, whereas the second step involved the hydrolysis of the same. The synthesized SM, SHM and SH molecules were characterized by FTIR, $^{1}H$-NMR and $^{13}C$-NMR spectroscopy, whereas diblock copolymers and pH-sensitive diblock copolymer were characterized by $^{1}H$-NMR and GPC analysis. The critical micelle concentrations were determined at various pH conditions by fluorescence technique using pyrene as a probe. The micellization and demicellization studies of pH-sensitive diblock copolymers were also done at different pH conditions. The pH-sensitivity was further established by acid-based titration and DLS analysis.

변위 감응형 충격흡수기에 관한 연구 (A study on the stroke sensitive shock absorber)

  • 박재우;주동우;김영호
    • 한국정밀공학회지
    • /
    • 제14권11호
    • /
    • pp.11-16
    • /
    • 1997
  • In the stroke sensitive shock absorber, the oil path is formed along the internal cylinder surface to make the oil flow during the piston's upper-lower reciprocation movement. In constrast with the conventional shock absorbesr which show one dynamic characteristic curve, stroke sensitive shock absorber shows two kinds of dynamic characteristics according to the stroke. In this study, in order to obtain more precise information about design and damping performance analysis, the analysis on the damping force generation process and dynamic behaviour characteristics of stroke sensitive shock absorber are performed by considering the valve characteristics.

  • PDF

휠 로더용 폐회로형 부하 감응 유압 제어 시스템의 특성 해석 (The Characteristic Analysis of the Load-sensitive Hydraulic Control System for Closed Center Type of a Wheel Loader)

  • 이승현;송창섭;정춘국
    • 대한기계학회논문집A
    • /
    • 제31권9호
    • /
    • pp.934-942
    • /
    • 2007
  • In this study, the characteristics of the load-sensitive hydraulic control system for closed center type of a wheel loader were analyzed using developed analysis program based on Amesim tool. From the parametric analysis, the effects of each factor were revealed. Through the simulation with varying parameters, the system parameter effects on the controllable region and the pump pressure and load pressure variations were studied. The results were compared with the experimental ones. The results and discussions of the present paper could aid in the design of a load-sensitive hydraulic control system for closed center type.

부하 감응형 유압 펌프 제어 시스템의 특성 해석에 관한 연구 (A Study on the Characteristic Analysis of the Load-sensitive Hydraulic Pump Control System)

  • 이용주;이승현;송창섭
    • 한국정밀공학회지
    • /
    • 제17권4호
    • /
    • pp.148-154
    • /
    • 2000
  • In this study, the static and the dynamic characteristics of the load-sensitive hydraulic pump control systems of a hydraulic excavator were analyzed using the developed analysis tool. The results were compared with the experimental ones. To improve the static performance of the system, the system parameter effects on the controllable region and the pump pressure variation were studied. The parameters enhancing dynamic characteristics were also considered.

  • PDF

Analyses of centrifuge modelling for artificially sensitive clay slopes

  • Park, Dong Soon
    • Geomechanics and Engineering
    • /
    • 제16권5호
    • /
    • pp.513-525
    • /
    • 2018
  • Slope stability of sensitive clayey soils is particularly important when subjected to strength loss and deformation. Except for progressive failure, for most sensitive and insensitive slopes, it is important to review the feasibility of conventional analysis methods based on peak strength since peak strength governs slope stability before yielding. In this study, as a part of efforts to understand the behavior of sensitive clay slopes, a total of 12 centrifuge tests were performed for artificially sensitive and insensitive clay slopes using San Francisco Bay Mud (PI = 50) and Yolo Loam (PI = 10). In terms of slope stability, the results were analyzed using the updated instability factor ($N_I$). $N_I$ using equivalent unit weight to cause a failure is in reasonable agreement shown in the Taylor's chart ($N_I$ ~ 5.5). In terms of dynamic deformation, it is shown that two-way sliding is a more accurate approach than conventional one-way sliding. Two-way sliding may relate to diffused shear surfaces. The outcome of this study is contributable to analyzing stability and deformation of steep sensitive clay slopes.

고분자감응성 LB막의 유변학적인 특성을 이용한 가스센서 연구 (The Study of Gas Sensor Using Rheological Properties of Polymeric Sensitive LB Films)

  • 강현욱;김정명;권영수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.198-201
    • /
    • 1997
  • The new system for identification of organic vapours and analysis method of mechanism between organic vapours and sensitive materials were attempted using the resonant resistance and resonant frequency of Quartz Crystal Analyzer (Q. C. A.). The resonant resistance shift means rheological changes in sensitive LB films occurred by the adsorption of organic vapours, while the resonant frequency shift represent the mass of organic vapour loaded in or on the sensitive LB films. It is thought that we can obtain more accurate response mechanism of organic vapour using the resonant frequency and resonant resistance diagram. The polymeric sensitive material were quantitively depositied using the LB method. In the experimental results, the adsorption behavior of organic vapour response can be decided by two type ; surface adsorption and penetration into sensitive material. Organic vapours had different positions in the Frequency-Resistance (F-R) diagram as to the kinds and concentrations of organic vapours. Thus F-R diagram can be applied to the development of one channel gas sensing system using the Quartz Crystal Analyzer.

  • PDF