• Title/Summary/Keyword: sensing of urine

Search Result 9, Processing Time 0.021 seconds

Design and implementation of Mobile U-health Service Platform - Feces and Urine Sensing U-Care Scheme -

  • Min, Byoung-Won;Oh, Yong-Sun
    • International Journal of Contents
    • /
    • v.5 no.4
    • /
    • pp.62-68
    • /
    • 2009
  • This paper presents a novel method to design and implement mobile u-health system by defining the essential elements of mobile healthcare services. We choose common service elements for the proposed u-healthcare scheme and design the service platform. Especially we focus on automatic feces or urine sensing u-care scheme to prove the effectiveness of our platform. We construct the system with sensing part with a manikin and a diaper wireless communication part with feces or urine sensing data, and coordinator system based on the u-health platform defined in this paper. Experimental results show that our scheme is useful in the area of u-care service for the handicapped, the elderly, and patients who can hardly move by themselves. In addition the designed scheme offers a realized u-care scheme with the purpose of advanced developing tools for application or service developers.

Improvement of Mobile U-health Service System Using Feces and Urine Sensing U-Care Scheme

  • Min, Byung-Won
    • International Journal of Contents
    • /
    • v.12 no.4
    • /
    • pp.17-22
    • /
    • 2016
  • This paper presents a novel method to design and implement mobile u-health system by defining the essential elements of mobile healthcare services. We choose common service elements for the proposed u-healthcare scheme and design the service platform. Especially we focus on automatic feces or urine sensing u-care scheme to prove the effectiveness of our platform. We construct the system with sensing part with a manikin and a diaper, wireless communication part with feces or urine sensing data, and coordinator system based on the u-health platform defined in this paper. Experimental results show that our scheme is useful in the area of u-care service for the handicapped, the elderly, and patients who can hardly move by themselves. In addition the designed scheme offers a realized u-care scheme with the purpose of advanced developing tools for application or service developers.

Development of an ultrasonic urination sensor for measurement of bladder urine volume (방광내 뇨량 측정을 위한 초음파 뇨의 센서의 개발)

  • Kim, D.J.;Choi, C.K.;Choi, H.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.151-152
    • /
    • 1998
  • The sensing of urination level of bladder urine volume is effective for preventing the urinary incontinence which is one of the three major infirmities afflicting the elderly. In this study, we found that it is useful for manufactured ultrasonic urination sensor to measure between distance of anterior and posterior wall of bladder, as a preliminary experiment. Also, Thee was a intimate interrelation between urine volume level and interwall distance of bladder.

  • PDF

u-Care system of urine and feces sensing intelligent type of USN basis (USN 기반의 대소변 감지 지능형 u-Care시스템)

  • Min, Byoung-won;Oh, Yong-sun;Lee, Hyeun-tae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.598-601
    • /
    • 2008
  • The people, who can't deal with urine and feces by themselves because they can't recognize it, deal with urine and feces with help of protector (Or nurse). For the case of urine and feces, disease of ulcerated flesh of hip like unpleasant feeling, pressure sore, humid tetter due to wetness of diaper can be prevented by changing diaper instantly. However, those people can't be possible to express their opinion, so they can't express their opinion on urine and feces or endure sense of shame. So there is a problem which can't check presence of urine and feces instantly. Accordingly, in order to solve this problem, qualitative improvement of nursing service can be generated by developing u-Care product which instantly let know urine and feces to protector (Or nurse) by perceiving automatically, and benefit of welfare on social dependent class like low income old people and solitude old people can be increased by reducing social welfare expense with increment of nursing expense.

  • PDF

Implementation of Bio-Sensor with Coupled Plasmon-Waveguide Resonance Profile (결합된 플라즈몬-도파관 공진 구조로 구성된 바이오센서의 구현)

  • Kwang-Chun Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.1
    • /
    • pp.109-114
    • /
    • 2024
  • The bio-sensing properties of TE and TM guided modes in the coupled plasmon-waveguide resonance (PWR) configuration are investigated. The modal transmission-line theory (MTLT) is used for numerical analysis. The proposed PWR bio-sensor is composed of multi-layered configuration with N pairs of MgF2-Si3N4 layers to enhance the sensitivity of a conventional Ag-based surface plasmon resonance bio-sensor. The angular sensitivity of bio-sensor is numerically analyzed for a wide range of biological solutions (refractive index 1.33~1.37). Furthermore, the availability of sensor to detect cancer cells and blood plasma concentration is evaluated. Finally, the results indicate that the proposed bio-sensor is capable efficiently to detect various kinds of cancer cells and different glucose concentrations in urine.

Low Power Diaper Urination Alarm Technology with Bluetooth v4.0 (블루투스 v4.0을 활용한 저(低)전력형 기저귀 배뇨 발생 알람 기술)

  • Paik, Jung Hoon
    • Convergence Security Journal
    • /
    • v.13 no.4
    • /
    • pp.27-32
    • /
    • 2013
  • In this paper, technologies applied to design urination detection device on diaper that issues an alarm signal to guardian within 10~20m are introduced. It features power saving that uses both low power bluetooth v4.0 chip and low-power program scheme that makes sensor and mirco-controller to be sleep mode while data is not receiving from sensor. Urination detection algorithm that utilizes the difference between previous sensing data and current values is used to improve the degree of the detection precision level. The device designed with the suggested technologies shows the performance that is 100ml of the minimum urine amount for detection, more than 90% of urination detection degree, and 100% of wireless communication success rate.

Sensing of the Insecticide Carbofuran Residues by Surface Plasmon Resonance and Immunoassay (표면플라즈몬공명과 효소면역분석법을 이용한 살충제 카보후란 잔류물 검출)

  • Yang G. M.;Cho N. H.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.6 s.113
    • /
    • pp.333-339
    • /
    • 2005
  • The pesticide is raising public interest in the world, because it causes damage to an environmental pollution and the human health remaining agricultural products and an ecosystem, in spite of the advantages. Particularly, each country restricts the residual pesticide and induces observance about the safety and usage standard so that they can control the amount of pesticide used and defend the safety of agricultural products. The habitual practice for the analysis of the residual pesticide depends on GC (gas chromatography), HPLC (high performance liquid chromatography) and GC/MS (gas chromatography/mass spectroscopy), which triturate the fixed quantity of samples, abstract and purify as a suitable organic solvent. These methods have the highly efficient in aspects of sensitivity and accuracy. On the other hand, they need the high cost, time consuming, much effort, expensive equipment and the skillful management. Carbofuran is highly toxic by inhalation and ingestion and moderately toxic by dermal absorption. As with other carbamate compounds, it is metabolized in the liver and eventually excreted in the urine. The half-life of carbofuran on crops is about 4 days when applied to roots, and longer than 4 days if applied to the leaves. This research was conducted to develop immunoassay for detecting carbofuran residue quickly on the basis of surface plasmon resonance and to evaluate the measurement sensitivity. Gold chip used was CM5 spreaded dextran on the surface. An applied antibody to Immunoassay was GST (glutathione-s-transferase). The association and the dissociation time were 176 second and 215 second between GST and carbofuran. The total analysis time using surface plasmon resonance was 13 minutes including regeneration time, on the other hand HPLC and GC/MS was 2 hours usually. The minimum detection limit of a permissible amount for carbofuran in the country is 0.1 ppm. The immunoassay method using surface plasmon resonance was 0.002 ppm.

Design of The Wearable Device considering ICT-based Silver-care (ICT 기반 실버케어를 고려한 웨어러블 디바이스 설계)

  • Lee, Min-hye;Shin, Seong-yoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.10
    • /
    • pp.1347-1354
    • /
    • 2018
  • A bedridden patients, elderly people, and dementia who are subject to special care at a medical institution can not handle the feces themselves and need the help of a guardian or care-giver. In particular, toxic substances are contained in the stools, which can cause eczema, dermatitis and urticaria, so it is important to replace diapers. In this paper, we propose a wearable device design for the detection of excretions in consideration of the various excretion requirements of the elderly. The device is a form in which a module are attached to an adult diaper used in a nursing hospital to detect excreta, and the presence or absence of a wearer can be confirmed by an LED. The measured data is transmitted to the smartphone app in real time via Bluetooth in the module and can be checked for popup notification. The validity of this study was verified by comparing the actual excretion with the data collected through the designed module.

Status of Agrometeorological Information and Dissemination Networks (농업기상 정보 및 배분 네트워크 현황)

  • Jagtap, Shrikant;Li, Chunqiang
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.2
    • /
    • pp.71-84
    • /
    • 2004
  • There is a growing demand for agrometeorological information that end-users can use and not just interesting information. lo achieve this, each region/community needs to develop and provide localized climate and weather information for growers. Additionally, provide tools to help local users interpret climate forecasts issued by the National Weather Service in the country. Real time information should be provided for farmers, including some basic data. An ideal agrometeorological information system includes several components: an efficient data measuring and collection system; a modern telecommunication system; a standard data management processing and analysis system; and an advanced technological information dissemination system. While it is conventional wisdom that, Internet is and will play a major role in the delivery and dissemination of agrometeorological information, there are large gaps between the "information rich" and the "information poor" countries. Rural communities represent the "last mile of connectivity". For some time to come, TV broadcast, radio, phone, newspaper and fax will be used in many countries for communication. The differences in achieving this among countries arise from the human and financial resources available to implement this information and the methods of information dissemination. These differences must be considered in designing any information dissemination system. Experience shows that easy across to information more tailored to user needs would substantially increase use of climate information. Opportunities remain unexplored for applications of geographical information systems and remote sensing in agro meteorology.e sensing in agro meteorology.