• Title/Summary/Keyword: semiconductor radiation detector

Search Result 68, Processing Time 0.031 seconds

입자침전법을 이용한 광도전체 필름의 X선 반응 특성에 관한 연구

  • Choe, Chi-Won;Gang, Sang-Sik;Jo, Seong-Ho;Gwon, Cheol;Nam, Sang-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.176-176
    • /
    • 2007
  • Flat-panel direct conversion detectors used in compound substance of semiconductor are being studied for digital x-ray imaging. Recently, such detectors are deposited by physical vapor deposition(PVD) generally. But, most of materials (HgI2, PbI2, TlBr, PbO) deposited by PVD have shown difficult fabrication and instability for large area x-ray imaging. Consequently, in this paper, we propose applicable potentialities for screen printing method that is coated on a substrate easily. It is compared to electrical properties among semiconductors such as $HgI_2$, $PbI_2$, PbO, HgBrI, InI, and $TlPbI_3$ under investigation for direct conversion detectors. Each film detector consists of an ~25 to $35\;{\mu}m$ thick layer of semiconductor and was coated onto the substrate. Substrates of $2cm{\times}2cm$ have been used to evaluate performance of semiconductor radiation detectors. Dark current, sensitivity and physics properties were measured. Leakage current of $HgI_2$ as low as $9pA/mm^2$ at the operation bias voltage of ${\sim}1V/{\mu}m$ was observed. Such a value is not better than PVD process, but it is easy to be fabricated in high quality for large area x-ray Imaging. Our future efforts will concentrate on optimization of growth of film thickness that is coated onto a-Si TFT array.

  • PDF

Radiation detector material development with multi-layer by hetero-junction for the reduction of leakage current (헤테르접합을 이용한 누설전류 저감을 위한 다층구조의 방사선 검출 물질 개발)

  • Oh, Kyung-Min;Yoon, Min-Seok;Kim, Min-Woo;Cho, Sung-Ho;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.11-15
    • /
    • 2009
  • In this study, the basic research verifying possibility of applications as radiology image sensor in Digital Radiography was performed, the radiology image sensor was fabricated using a multi-layer technique to decrease dark current. High efficiency materials in substitution for Amorphous Selenium(a-Se) have been studied as a direct method of imaging detector in Digital Radiography to decrease dark current by using PN junction or Hetero junction already used as solar cell, semiconductor. Particle-In -Binder method is used to fabricate radiology image sensor because it has a lot of advantages such as fabrication convenient, high yield, suitability for large area sensor. But high leakage current is one of main problem in Particle-In -Binder method. To make up for the weak points, multi-layer technique is used, and it is considered that high efficient digital radiation sensor can be fabricated with easy and convenient process. In this study, electrical properties such as leakage current, sensitivity, signal linearity is measured to evaluate multi-layer radiation sensor material.

  • PDF

Development of a Portable Detection System for Simultaneous Measurements of Neutrons and Gamma Rays (중성자선과 감마선 동시측정이 가능한 휴대용 계측시스템 개발에 관한 연구)

  • Kim, Hui-Gyeong;Hong, Yong-Ho;Jung, Young-Seok;Kim, Jae-Hyun;Park, Sooyeun
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.481-487
    • /
    • 2020
  • Radiation measurement technology has steadily improved and its usage is expanding in various industries such as nuclear medicine, security search, satellite, nondestructive testing, environmental industries and the domain of nuclear power plants (NPPs). Especially, the simultaneous measurements of gamma rays and neutrons can be even more critical for nuclear safety management of spent nuclear fuel and monitoring of the nuclear material. A semiconductor detector comprising cadmium, zinc, and tellurium (CZT) enables to detect gamma-rays due to the significant atomic weight of the elements via immediate neutron and gamma-ray detection. Semiconductor sensors might be used for nuclear safety management by monitoring nuclear materials and spent nuclear fuel with high spatial resolution as well as providing real-time measurements. We aim to introduce a portable nuclide-analysis device that enables the simultaneous measurements of neutrons and gamma rays using a CZT sensor. The detector has a high density and wide energy band gap, and thus exhibits highly sensitive physical characteristics and characteristics are required for performing neutron and gamma-ray detection. Portable nuclide-analysis device is used on NPP-decommissioning sites or the purpose of nuclear nonproliferation, it will rapidly detect the nuclear material and provide radioactive-material information. Eventually, portable nuclide-analysis device can reduce measurement time and economic costs by providing a basis for rational decision making.

Evaluation of the Decontamination Efficiency of Radioactive Wastes Generated during the Production of 201Tl (201Tl의 생산과정에서 발생한 방사성 폐기물의 제염 효율 평가)

  • Heo, Jae-Seung;Kim, Sang-Rok;Kim, Gi-Sub;Ahn, Yun-jin;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.481-487
    • /
    • 2021
  • This study was conducted for the purpose of efficient radioactive waste disposal and management. Experiment was evaluated the decontamination efficiencies of the four types decontamination materials(Water, Alcohol, Decontamination Water, Decontamination Gel) with radioactive wastes generated during radio-pharmaceutical production process at Korea Institute Radiological and Medical Sciences(KIRAMS). The radioactive waste sample used in experiment is a lead plate of the fume hood that was disposed in April, 2019. In the experimental method, radioactive waste was measured before and after decontamination using a HPGe semiconductor detector and Gamma survey meter. The measured values before and after decontamination were evaluated for decontamination efficiency as a percentage. As a result, it was confirmed that a lot of specific activity and surface dose rate was removed from the radioactive wastes. In particular, when decontamination water was used, most of the radioactivity of radioactive wastes was removed. Considering these results, if decontamination water is used in decontamination of radioactive waste, decontamination efficiency equivalent to the disposition criteria can be expected with just one decontamination treatment. In addition, in the case of water and alcohol, only on decontamination was effective in approximately 75% and 95%. Otherwise, when decontamination gel was used, it was confirmed that the largest deviation occurred among all experimental results.

Establishing a pre-mining baseline of natural radionuclides distribution and radiation hazard for the Bled El-Hadba sedimentary phosphate deposits (North-Eastern Algeria)

  • S. Benarous;A. Azbouche;B. Boumehdi;S. Chegrouche;N. Atamna;R. Khelifi
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4253-4264
    • /
    • 2022
  • Since the implementation of the phosphate project in Bled El-Hadba (BEH) deposit, western region of Tébessa, no detailed study has been conducted to assess the natural radioactivity distribution and the associated radiological risk parameter for this open-pit mine. For the sake of determining a credible premining reference database for the region of interest, 21 samples were collected from different geological layers of the above-mentioned deposit. Gamma Spectrometry was applied for measuring radioactivity using a high resolution HPGe semiconductor detector. The obtained activity results have shown a significant broad variation in the radioactive contents for the different phosphate samples. The total average concentrations (in Bq·kg-1) for 226Ra, 238U, 235U, 232Th and 40K computed for the different type of phosphate layers were found to be 570 ± 169, 788 ± 280, 52 ± 18, 66 ± 6 and 81 ± 18 respectively. The mean activity concentrations of the measured radionuclides were compared to other regional and worldwide deposits. The ratios between the detected radioisotopes have been calculated for spatial distribution of natural radionuclides in the study area. Based on the aforementioned activity concentrations, the corresponding radiation hazard parameters were assessed. Correlations between the obtained parameters were drawn and a multivariate statistical analysis (Pearson Correlation, Cluster and Factor analysis) was carried out in order to identify the existing relationships.

The Simulation on Dose Distributions of the 6 MeV Electron Beam in Water Phantom (6 MeV 전자선의 물팬텀 속의 선량분포에 관한 모의계산)

  • Lee, Jeong-Ok;Jeong, Dong-Hyeok;Moon, Sun-Rock
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.75-79
    • /
    • 2000
  • This study was performed for the clinical applications applying the Monte Carlo methods. In this study we calculated the absorbed dose distributions for the 6 MeV electron beam in water phantom and compared the results with measured values. The energy data of electron beam used in Monte Carlo calculation is the energy distribution for 6 MeV electron beam which is assumed as a Gaussian form. We calculated percent depth doses and beam profiles for three field sizes of $10{\times}10,\;15{\times}15$, and $20{\times}20\;cm^2$ in water phantom using Monte Carlo methods and measured those data using a semiconductor detector and other devices. We found that the calculated percent depth doses and beam profiles agree with the measured values approximately. However, the calculated beam profiles at the edge of the fields were estimated to be lower than the measured values. The reason for that result is that we did not consider the angular distributions of the electrons in phantom surface and contamination of X-rays in our calculations. In conclusion, in order to apply the Monte Carlo methods to the clinical calculations we are to study the source models for electron beam of the linear accelerator beforehand.

  • PDF

ASIC Implementation of Nuclear Radiation Detector Using Semiconductor Sensor (반도체 센서를 이용 방사선 검출기의 ASIC 구현)

  • Yi, Un-Kun;Baek, Kwang-Ryul;Sohn, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2353-2355
    • /
    • 2004
  • 본 논문에서는 고정도의 방사선 측정이 가능한 능동형 전자선량계를 제작하기 위해 필수적으로 요구되는 반도체 방사선 검출기를 ASIC으로 구현하였다. 이는 전자선량계의 소형화와 저소비전력을 실현할 수 있도록 전치증폭기와 성형증폭기를 일체화한 것으로 방사선과 방사선 검출 소자인 상용 핀 포토다이오드의 상호작용으로 생성된 수 [nA]의 전류펄스를 측정할 수 있다. MOSIS 공정을 통하여 ASIC으로 구현된 방사선검출기는 $10{\mu}Ci$${\gamma}$-선 Ba-133, Cs-137 및 Co-60의 세 핵종에 대하여 방사선 조사시험을 수행하여 구현된 방사선 검출기의 유용성을 입증하였다.

  • PDF

MATERIAL INVESTIGATION AND ANALYSIS USING CHARACTERISTIC X-RAY

  • Oh, Gyu-Bum;Lee, Won-Ho
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.426-433
    • /
    • 2010
  • The characteristic X-rays emitted from materials after gamma ray exposure was simulated and measured. A CdTe semiconductor detector and a $^{57}Co$ radiation source were used for energy spectroscopy. The types of materials could be identified by comparing the measured energy spectrum with the theoretical X-ray transition energy of the material. The sample composition was represented by the $K_{\alpha1}$-line (Siegbahn notations), which has the highest intensity among the characteristic X-rays of each atom. The difference between the theoretic prediction and the experimental result of K-line measurement was < 0.61% even if the characteristic X-rays from several materials were measured simultaneously. 2D images of the mixed materials were acquired with very high selectivity.

Measurement and Monte Carlo Simulation of 6 MV X-rays for Small Radiation Fields (선형가속기의 6 MV X-선에 대한 소형 조사면 측정과 몬테 카를로 시뮬레이션)

  • Jeong Dong Hyeok;Lee Jeong Ok;Kang Jeong Ku;Kim Soo Kon;Kim Seung Kon;Moon Sun Rock
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.195-202
    • /
    • 1998
  • Purpose : In order to obtain basic data for treatment plan in radiosurgery, we measured small fields of 6 MV X-rays and compared the measured data with our Monte Carlo simulations for the small fields. Materials and Methods : The small fields of 1.0, 2.0 and 3.0 cm in diameter were used in this study. Percentage depth dose (PDD) and beam Profiles of those fields were measured and calculated. A small semiconductor detector, water phantoms, and a remote control system were used for the measurement Monte Carlo simulations were Performed using the EGS4 code with the input data prepared for the energy distribution of 6 MV X-rays, beam divergence, circular fields and the geometry of the water phantoms. Results : In the case of PDD values, the calculated values were lower than the measured values for all fields and depths, with the differences being 0.3 to 5.7% at the depths of 20 to 20.0 cm and 0.0 to 8.9% at the surface regions. As a result of the analysis of beam profiles for all field sizes at a depth of loom in water phantom, the measured 90% dose widths were in good agreement with the calculated values, however, the calculated Penumbra radii were 0.1 cm shorter than measured values. Conclusion : The measured PDDs and beam profiles agreement with the Monte Carlo calculations approximately. However, it is different when it comes to calculations in the area of phantom surface and penumbra because the Monte Carlo calculations were performed under the simplified geometries. Therefore, we have to study how to include the actual geometries and more precise data for the field area in Monte Carlo calculations. The Monte Carlo calculations will be used as a useful tool for the very complicated conditions in measurement and verification.

  • PDF

Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography (디지털 래디오그라피의 신호 및 잡음 특성에 대한 방사선 영향에 관한 연구)

  • Kim, Ho-Kyung;Cho, Min-Kook;Graeve, Thorsten
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.756-767
    • /
    • 2007
  • For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of $Min-R^{TM}$ screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.