• Title/Summary/Keyword: semi-aqueous cleaning agents cleaning

Search Result 5, Processing Time 0.022 seconds

Evaluation of Cleaning ability and Environmental Evaluation of Commercial Aqueous/Semi-aqueous Cleaning Agents (시판 수계/준수계 세정제의 세정성 및 환경성 평가 연구)

  • Cha, A.J.;Park, J.N.;Kim, H.S.;Bae, J.H.
    • Clean Technology
    • /
    • v.10 no.2
    • /
    • pp.73-87
    • /
    • 2004
  • In most of industrial fields, cleaning is employed for removing soils on their products or parts. Halogenated cleaning agents such as CFC-113, 1,1,1-TCE(1,1,1-trichloroethane), MC(methylene chloride) and TCE (trichloroethylene) have been used as cleaning ones in most of companies in the world since their excellent performance of cleaning ability and good material compatibility. However, CFC-113 and 1,1,1-TCE which are ozone destruction substances are not used any more in the advanced countries because of the which are ozone destruction substances are not used any more in the advanced countries because of the Montreal protocol. MC and TCE are now used restrictively at small part of industrial fields in most of countries since they are known to be hazardous or carcinogenic materials. Thus, it is indispensible that the alternative cleaning agents which are environmental-friendly and safe, and show good cleaning ability should be developed or utilized for replacement of the halogenated cleaning agents. Aqueous/semi-aqueous cleaning agents are evaluated to be promising alternative ones among various alternatives in environmental and economical view point. In this study, commercially available 12 aqueous and 6 semi-aqueous cleaning agents were selected and their physical properties, cleaning abilities, rinsing abilities and recycling of contaminated rinse water were measured and analyzed. Aqueous cleaning agents with higher wetting index showed better cleaning ability compared with those with lower wetting index. However wetting index did not have any correlation with cleaning ability in semi-aqueous cleaning agents. It was observed that soil concentration in aqueous and semi-aqueous cleaning agents should be maintained below the certain concentrations which depend on types of clearing agents. More than 70% soils in contaminated rinse water by some of aqueous and semi-aqueous clearing agents could be separated by simple settling method. This means that some cleaning agents with high oil-water separation efficiency will be effiective for recycling oil-contaminated rinse water. It was found that contaminated rinse water with aqueous agents was purified easiy by ultrafiltration method with PAN membrane of 30 kDa.

  • PDF

Enviromentally Friendly Aqueous/Semi-aqueous Cleaning Technology (환경친화적 수계/준수계 세정 기술)

  • Bae, Jae-Heum;Kim, Jung-Sik
    • Clean Technology
    • /
    • v.3 no.2
    • /
    • pp.36-46
    • /
    • 1997
  • CFC and organic chlorine solvents has been used in the fine machinery and electronics industries for a long time since they have various excellent properties as cleaning agents. However, it is inevitable that alternative cleaning agents should be used since CFC and organic chlorine solvents were identified as ozone-depleting chemicals. There are various alternative cleaning agents. Among them, aqueous/semi-aqueous cleaning agents are environmentally friendly and promising in the long term. And their use and developement are on the increase in advanced countries, but few in our countries. In this paper, the charactistics and major components aqueous/semi-aqueous cleaning agents are analyzed and compared. And various cleaning equipments for aqueous/semi-aqueous cleaning agents such as immersion cleaner, ultronsonic cleaners, power spray cleaner, and vibration or rotational cleaners are compared and evaluated. Finally, important consideration points for selction of a cleaning system are analyzed and suggested in this paper.

  • PDF

Development of Aqueous/Semi-Aqueous Cleaning Agent and its Field Application to Cleaning Process of Electronic Parts (수계/준수계 세정제의 개발 및 전자부품 세정공정 현장적용 연구)

  • Kim, Han-Seong;Cha, An-Jeong;Bae, Jae-Heum;Lee, Ha-Yeoul;Lee, Myung-Jin;Park, Byeong-Deog
    • Clean Technology
    • /
    • v.10 no.2
    • /
    • pp.61-72
    • /
    • 2004
  • In this study, aqueous/semi-aqueous cleaning agents which consist of organic solvent, surfactant, cosurfactant, and water were developed by changing formulation parameters such as organic solvent type and contents, surfactant type and contents, and cosurfactant/surfactant(A/S) ratio, etc.. And physical properties and flux removal of the formulated cleaning agents have been evaluated. Also, the performance of oil-water separation from the rinse water contaminated during the cleaning process was evaluated for its recycling. The formulated cleaning agents in this work expected to have good penetration because of their low viscosity and low surface tension values of 30.2~32.5 dyne/cm. The flux removal with the terpene type cleaning agent was higher than that with hydrocarbon type cleaning agent and two commercial products (CPA(commercial product A), CPB(commercial product B)). And the performance of oil-water separation by gravity settling from the rinse water contaminated with formulated cleaning agent and soils was shown to be very good. The cleaning agents developed in this work were applied to surface mounting technology(SMT) cleaning process for manufacturing electronic parts at L electronic company. As a result, the newly developed cleaning agents showed two times better cleaning speed for removal of solder cream than the conventional ond containing ethanol and IPA(isopropyl alcohol). In addition, malodor and VOC problems generated by the previous organic cleaning agents have been solved in the manufacturing field through introduction of the non-volatile and environmental-friendly cleaning agents to the field.

  • PDF

Development of Cleaning System of Electronic Components for the Remanufacturing of Laser Copy Machine (레이저 복합기의 재제조공정을 위한 전자부품 세정시스템의 개발)

  • Bae, Jae-Heum;Chang, Yoon-Sang
    • Clean Technology
    • /
    • v.18 no.3
    • /
    • pp.287-294
    • /
    • 2012
  • In this study, performances of two cleaning methods were analyzed and a cleaning system was designed to develop a cleaning process of electronic components to remanufacture old laser copy machine. First, plasma cleaning as a dry cleaning method was executed to test cleaning ability. In cleaning of printed circuit board (PCB) by plasma, some damages were found near the metal parts, and considering the productivity, this method was not adequate for the cleaning of electronic components. With 4 different cleaning agents, ultrasonic cleaning tests were executed to select an optimal cleaning agent, aqueous agents showed superior cleaning performance compared to semi-aqueous and non-aqueous agents. Cleaning with aqueous cleaning agent A and 28 kHz ultrasonic frequency can be completed in 30 sec to 1 min. Finally, an ultrasonic cleaning system was constructed based on the pre-test results. Optimal cleaning conditions of 40 kHz and $50^{\circ}C$ were found in the field test. The productivity and economic efficiency in remanufacturing of laser copy machine are expected to increase by adapting developed ultrasonic cleaning system.

A Study on Laboratory Treatment of Metalworking Wastewater Using Ultrafiltration Membrane System and Its Field Application (한외여과막시스템을 이용한 금속가공폐수의 실험실적 처리 및 현장 적용 연구)

  • Bae, Jae Heum;Hwang, In-Gook;Jeon, Sung Duk
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.487-494
    • /
    • 2005
  • Nowadays a large amount of wastewater containing metal working fluids and cleaning agents is generated during the cleaning process of parts working in various industries of automobile, machine and metal, and electronics etc. In this study, aqueous or semi-aqueous cleaning wastewater contaminated with soluble or nonsoluble oils was treated using ultrafiltration system. And the membrane permeability flux and performance of oil-water separation (or COD removal efficiency) of the ultrafiltration system employing PAN as its membrane material were measured at various operating conditions with change of membrane pore sizes and soil concentrations of wastewater and examined their suitability for wastewater treatment contaminated with soluble or insoluble oil. As a result, in case of wastewater contaminated with soluble oil and aqueous or semi-aqueous cleaning agent, the membrane permeability increased rapidly even though COD removal efficiency was almost constant as 90 or 95% as the membrane pore size increased from 10 kDa to 100 kDa. However, in case of the wastewater contaminated with nonsoluble oil and aqueous or semi-aqueous cleaning agent, as the membrane pore size increased from 10 kDa to 100 kDa and the soil concentration of wastewater increased, the membrane permeability was reduced rapidly while COD removal efficiency was almost constant. These phenomena explain that since the membrane material is hydrophilic PAN material, it blocks nonsoluble oil and reduces membrane permeability. Thus, it can be concluded that the aqueous or semi-aqueous cleaning solution contaminated with soluble oil can be treated by ultrafiltration system with the membrane of PAN material and its pore size of 100 kDa. Based on these basic experimental results, a pilot plant facility of ultrafiltration system with PAN material and 100 kDa pore size was designed, installed and operated in order to treat and recycle alkaline cleaning solution contaminated with deep drawing oil. As a result of its field application, the ultrafiltration system was able to separate aqueous cleaning solution and soluble oil effectively, and recycle them. Further more, it can increase life span of aqueous cleaning solution 12 times compared with the previous process.