• 제목/요약/키워드: selling price per plant

검색결과 2건 처리시간 0.014초

Theoretical Design for the Production of Quinoa (Chenopodium quinoa Willd.) in a Closed Plant Factory

  • Bae, Jong Hyang;Austin, Jirapa;Jeon, Yoon-A;Cha, Mi-Kyung;Cho, Young-Yeol
    • 원예과학기술지
    • /
    • 제34권6호
    • /
    • pp.840-844
    • /
    • 2016
  • Quinoa (Chenopodium quinoa Willd.) is a grain crop with high nutritional value. The leaves and sprouts of quinoa can also be consumed either raw or cooked, providing considerably nutritional value as well as high antioxidant and anticancer activities. This study was carried out to obtain basic data to assist in the practical design of a plant factory with artificial lighting for the cultivation of quinoa as a leafy vegetable. We estimated the energy content of the quinoa and the electrical energy required to produce this crop. The yield was 1,000 plants per day, with a planting density and light intensity of $0.015m^2$ ($15{\times}10cm$) and $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively. The total number of plants, cultivation area, and electricity consumption were estimated to be 25,000, $375m^2$, and $93,750{\mu}mol{\cdot}s^{-1}$, respectively. White fluorescent lamps were used at a power of 20.4 kW from 1,857 fluorescent lamps (FL, 55 W), and the cost for electricity was approximately 1,820 dollars (exchange rate of $1 = 1,200 won) per month. For a daily harvest of 1,000 plants per day in a closed plant factory, the estimated light installation cost, total installation cost, and total production cost would be 15,473, 46,421, and 55,704 dollars, respectively. The calculated production cost per plant, including labor costs, would be 27 cents for the 25-day cultivation period, with a marketable ratio of 80%. Considering the annual total expenses, income, and depreciation costs, the selling price per plant was estimated to be approximately 56 cents.

國內 微分炭 化力發電所에서 바닥재 再活用을 위한 乾式 바닥재 處理시스템 導入의 經濟性 分析 (Ⅱ) -旣存設備 改善事業에 대하여 (Economic Analysis of Dry Bottom Ash Handling System in a Pulverized Coal Thermal Power Plant in Korea (Ⅱ) -Case Study for Retrofitting the Existing Facility)

  • 오세원
    • 자원리싸이클링
    • /
    • 제14권2호
    • /
    • pp.56-61
    • /
    • 2005
  • 국내 기존의 석탄화력발전기에서 운영 중인 충수중력식 바닥재 처리시스템을 바닥재의 재활용이 가능한 건식처리시스템으로 교체하는 개선사업에 대하여 500MW${\times}$2기 발전설비를 대상으로 경제성을 분석하였다. 건식처리시스템으로의 개선 시 초기투자비는 13,415,127천원이 소요되며, 시설운영비는 연간 935,345천원이 절감될 것으로 예측되었다. 이를 기초로 경제성 평가를 수행한 결과, 개선사업 시 소요되는 초기투자비는 자본 이익률 10%에서 시설사용연한 내에 회수가 불가능하였으며, 투자이익률은 5.6%로 산정되어, 현재 국내 조건에서 개선사업은 경제성을 확보하지 못하는 것으로 평가되었다. 이는 신규발전설비에 건식처리시스템의 도입이 경제성을 확보하는 것과 유럽에서 개선사업이 경제성을 확보하는 것과 다른 결과를 보이고 있는데, 이는 회매립비 차이에 기인하는 것으로 검토되었다. 향후 국내 시장 여건의 변화에 따라 회매립비와 회판매가가 변동할 경우의 경제성 분석결과, 개선사업은 회판매가가 17,000원/톤 이상으로 상승하거나 회매립비가 15,000원/톤 이상으로 상승할 경우, 경제성을 확보할 수 있는 것으로 평가되었다.