• 제목/요약/키워드: selective measurement method

검색결과 73건 처리시간 0.026초

Evaluation of measurement uncertainty for quantitative determination of chlorite and chlorate in fresh-cut vegetables using ion chromatography

  • Jung, Sungjin;Kim, Dasom;Lee, Gunyoung;Yun, Sang Soon;Lim, Ho Soo;Jung, Young Rim;Kim, Hekap
    • 한국식품과학회지
    • /
    • 제49권6호
    • /
    • pp.591-598
    • /
    • 2017
  • This study aimed to evaluate the measurement uncertainty for the quantitative determination of chlorite and chlorate in ready-to-eat fresh-cut vegetables using ion chromatography with a hydroxide-selective column. One gram of the homogenized sample in deionized water was sonicated and centrifuged at 8,500 rpm. The supernatant was purified by passing it through a Sep-Pak tC18 cartridge, followed by chromatographic determination using a Dionex IonPac AS27 column. The linearity of the calibration curves, recovery, repeatability, and reproducibility of the method were satisfactory. The method detection limit was estimated to be approximately 0.5 mg/kg. Each uncertainty component was evaluated separately, and the combined and expanded uncertainty values were calculated at the 95% confidence level. The measured concentrations for 3 mg/kg of chlorite and chlorate standard materials were $3.18{\pm}0.32$ and $3.10{\pm}0.42mg/kg$, respectively. These results confirmed the reliability of the developed method for measuring the two chlorine-based oxyanions in fresh-cut vegetables.

우드칩을 연료로 하는 열병합발전소의 회분 퇴적 및 설비 고장 원인 분석 (Investigating the Cause of Ash Deposition and Equipment Failure in Wood Chip-Fueled Cogeneration Plant)

  • 송민지;김우철;김희산;김정구;이수열
    • Corrosion Science and Technology
    • /
    • 제22권3호
    • /
    • pp.187-192
    • /
    • 2023
  • The use of biomass is increasing as a response to the convention on climate change. In Korea, a method applied to replace fossil fuels is using wood chips in a cogeneration plant. To remove air pollutants generated by burning wood chips, a selective denitrification facility (Selective catalytic reduction, SCR) is installed downstream. However, problems such as ash deposition and descaling of the equipment surface have been reported. The cause is thought to be unreacted ammonia slip caused by ammonia ions injected into the reducing agent and metal corrosion caused by an acidic environment. Element analysis confirmed that ash contained alkali metals and sulfur that could cause catalyst poisoning, leading to an increase in the size of ash particle and deposition. Measurement of the size of ash deposited inside the facility confirmed that the size of ash deposited on the catalyst was approximately three times larger than the size of generally formed ash. Therefore, it was concluded that a reduction in pore area of the catalyst by ash deposition on the surface of the catalyst could lead to a problem of increasing differential pressure in a denitrification facility.

Experimental Study on Temperature Dependence of Nitrate Sensing using an ISE-based On-site Water Monitoring System

  • Jung, Dae-Hyun;Kim, Dong-Wook;Cho, Woo Jae;Kim, Hak-Jin
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2017년도 춘계공동학술대회
    • /
    • pp.122-122
    • /
    • 2017
  • Recently, environmental problems have become an area of growing interests. In-situ monitoring of water quality is fundamental to most environmental applications. The accurate measurement of nitrate concentrations is fundamental to understanding biogeochemistry in aquatic ecosystems. Several studies have reported that one of the most feasible methods to measure nitrate concentration is the use of Ion Selective-electrodes (ISEs). The ISE application to water monitoring has several advantages, such as direct measurement methodology, high sensitivity, wide measurement range, low cost, and portability. However, the ISE methods may yield inconsistent results where there was a difference in temperature between the calibration and measurement solutions, which is associated with the temperature dependence of ionic activity coefficients in solution. In this study, to investigate the potential of using the combination of a temperature sensor and nitrate ISEs for minimizing the effect of temperature on real-time nitrate sensing in natural water, a prototype of on-site water monitoring system was built, mainly consisting of a sensor chamber, an array of 3 ISEs, an waterproof temperature sensor, an automatic sampling system, and an arduino MCU board. The analog signals of ISEs were obtained using the second-order Sallen-key filter for performing voltage following, differential amplification, and low pass filtering. The performance test of the developed water nitrate sensing system was conducted in a monitoring station of drinking water located in Jeongseon, Kangwon. A temperature compensation method based on two-point normalization was proposed, which incorporated the determination of temperature coefficient values using regression equations relating solution temperature and electrode signal determined in our previous studies.

  • PDF

AHP를 이용한 오픈소스 다기능 게시판의 평가 사례연구 (A Case Study on the Evaluation of Open Source Bulletin Board System with Multi-Function by the Analytical Hierarchy Process)

  • 심민재;장성용;이원영
    • 경영과학
    • /
    • 제27권1호
    • /
    • pp.91-105
    • /
    • 2010
  • We proposed and stratified a selection standard model on Open Source Functional Board which could be found in Web. So we could grasp the weight about Performance Evaluation from the viewpoints of planners, developers, and web disigner professional of views. We suggested applying diverse measurement types in case of item which could chart Evaluation Standards on chosen sample boards. In case of item which couldn't do that, we compared and analyzed it by using selective type of 9 point scaling method on professionalists in every sample board. As a result of weight on upper estimate section of evaluation model chart, the order of importance was convenience(0.334), performance(0.333), function(0.240) and design(0.093) respectively. It indicates that there is more weight on performance and convenience which are hard to be structurally modified than designs and functions that are directly shown to the users. Also, it was evident that opposite results came out when using 9-point scale survey and measurement with objective data such as function and performance. The reason is because the surveyed subject can have his or her own subjectivity and bias unlike objective data. However, objectivity of the administrator is also an important factor thus both two perspectives have to be all considered when selecting the bulletin board.

배연탈질설비의 성능향상을 휘한 가스혼합에 관한 연구 (A Study on the Flue Gas Mixing for the Performance Improvement of De-NOx plant)

  • 류병남
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.462-472
    • /
    • 1999
  • De-NOx facility using Selective Catalytic Reduction method is the most widely applied one that removes NOx from flue gas emitted from combustion facility such as boiler for power generation engine incinerator etc. Reductant $NH_3\;or\;NH_4OH$ is sprayed into flue gas to convert NOx into $H_2O$ and $N_2.$ Good mixing between flue gas and $NH_3$ is the most important factor to increase reduction in catalytic layer and to reduce unreacted NH3 slip. Therefore the development of mixer device for mixing effect is one of the important part for SCR facility. Objectives of this study are to investigate the relation between flow and concentration field by observation at the wake of delta-wing type mixer. At the first stage qualitative measurement of flow field is conducted by flow visualization using laser light sheet in lab. scale wind tunnel. Also we have conducted the quantitative analysis by comparing flow field measurement using LDV with numerical simulation. On the basis of qualitative and quantitative analysis we investigate the dis-tribution of flow and concentration in flow model facility. The results of an experimental and compu-tational examination of the vortex structures shed from delta wing type vortex generator having $40^{\circ}$ angle of attack are presented, The effects of vortex structure on the gas mixing is discussed, too.

  • PDF

능동 소음제어를 이용한 잔향실의 저주파 특성 개선 가능성 (Improvements of Reverberation Chamber's Performance by using Active Noise Control)

  • 김영기;오시환;문상무;임종민;김홍배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.857-861
    • /
    • 2004
  • An active method that improves low frequency characteristics of a reverberation chamber has been proposed. Spatial uniformity of sound pressure at low frequency has been increased by applying active noise control system. The system acts as frequency selective damping materials, which decreases resonance at low frequency and leave high frequency sound field as it is. Linearity of the chamber, which is essential for sound power measurement in the chamber, is guaranteed since fixed control logic has been adopted. Simple application and tests have been done in a small sized rectangular reverberation chamber which has 400Hz cutoff, Loud speakers were used to simulate a noise source and to construct an active noise control system. The spatial distribution of a sound field at 250Hz, 315Hz and 400Hz bands has been measured before and after control. The standard deviation of sound field has been decreased from 3.4dB to 2.5dB. The results show the possibility of active control system as a sound diffuser.

  • PDF

우리 나라 배경농도지역의 1996~1997년 미세입자상 탄소성분 측정 결과 (Measurement of Carbonaceous Species in Fine Particles at the Background Sites in Korea During 1996 and 1997)

  • 김용표;이종훈
    • 한국대기환경학회지
    • /
    • 제14권6호
    • /
    • pp.621-630
    • /
    • 1998
  • The concentrations of organic carbon (OC) and elemental carbon (EC) in fine aerosols were determined from the samples collected at the two background sites of Kosan in Cheju Island and Kangwha. Samplings were carried out during the spring and winter of 1996 and the fall and winter of 1997. PM25 particles were collected on the prefired quartz filters for 24 hours and analyzed by the selective thermal oxidation method. The concentrations of OC at the sites were higher than those commonly observed from clean areas around the world, but those of EC at both sites were lower than, or comparable to, other clean areas in the world. Both the OC and EC levels at Kangwha were higher than those at Kosan. According to backward trajectory analysis, most air pollutants collected at the two sites were from China. It was found that the OC and EC concentrations in air masses from southern China were higher than those from northern China.

  • PDF

자기연마법을 응용한 미세금형부품의 초정밀 연마 (Ultra Precision Polishing of Micro Die and Mold Parts using Magnetic-assisted Machining)

  • 안병운;김욱배;박성준;이상조
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1832-1835
    • /
    • 2003
  • This paper suggests the selective ultra precision polishing techniques for micro die and mold parts using magnetic-assisted machining. Fabrication of magnetic abrasive particle and their polishing performance are key technology at ultra precision polishing process of micro parts. Conventional magnetic abrasives have disadvantages. which are missing of abrasive particle and inequality between magnetic particle and abrasive particle. So, bonded magnetic abrasive particles are fabricated by several method. For example, plasma melting and direct bonding. Ferrite and carbonyl iron powder are used as magnetic particle where silicon carbide and Al$_2$O$_3$ are abrasive particle. Developed particles are analyzed using measurement device such as SEM. Possibility of magnetic abrasive and polishing performance of this magnetic abrasive particles also have been investigated. After polishing, surface roughness of workpiece is reduced from 2.927 $\mu\textrm{m}$ Rmax to 0.453 $\mu\textrm{m}$ Rmax.

  • PDF

Visible-light photo-reduction of reduced graphene oxide by lanthanoid ion

  • Kim, Jinok;Yoo, Gwangwe;Park, Jin-Hong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.290.1-290.1
    • /
    • 2016
  • Grapehen, a single atomic layer of graphite, has been in the spotlight and researched in vaious fields, because its fine mechanical, electrical properties, flexibility and transparence. Synthesis methods for large-area graphene such as chemical vaper deposition (CVD) and mechanical, chemical exfoliation have been reported. In particular, chemical exfoliation method receive attention due to low cost process. Chemical exfoliation method require reduction of graphene oxide in the process of exfoliation such as chemical reduction by strong reductant, thermal reduction on high temperature, and optical reduction via ultraviolet light exposure. Among these reduction methods, optical reduction is free from damage by strong reductant and high temperature. However, optical reduction is economically infeasible because the high cost of short-wavelength ultraviolet light sorce. In this paper, we make graphene-oxide and lanthanoid ion mixture aqueous solution which has highly optical absorbency in selective wevelength region. Sequentially, we synthesize reduced graphene oxide (RGO) using the solution and visible laser beam. Concretely, graphene oxide is made by modified hummer's method and mix with 1 ml each ultraviolet ray absorbent Gd3+ ion, Green laser absorbent Tb3+ ion, Red laser absorbent Eu3+ ion. After that, we revivify graphene oxide by laser exposure of 300 ~ 800 nm layser 1mW/cm2 +. We demonstrate reproducibility and repeatability of RGO through FT-IR, UV-VIS, Low temperature PL, SEM, XPS and electrical measurement.

  • PDF

Determination of Ultra Trace Levels of Copper in Whole Blood by Adsorptive Stripping Voltammetry

  • Attar, Tarik;Harek, Yahia;Larabi, Lahcen
    • 대한화학회지
    • /
    • 제57권5호
    • /
    • pp.568-573
    • /
    • 2013
  • A selective and sensitive method for simultaneous determination of copper in blood by adsorptive differential pulse cathodic stripping voltammetry is presented. The procedure involves an adsorptive accumulation of Cu(II)-ETSC (4- ethyl-3-thiosemicarbazide) on a hanging mercury drop electrode, followed by a stripping voltammetry measurement of reduction current of adsorbed complex at about -715 mV. The optimum conditions for the analysis of copper (II) ion are : pH 10.3, concentration of 4-ethyl-3-thiosemicarbazide $3.25{\times}10^{-6}$ M and an accumulation potential of -100 mV. The peak current is proportional to the concentration of copper over the range 0.003-125 ng/mL with a detection limit of 0.001 ng/mL and an accumulation time of 60 s. Moreover, with the use of the proposed method, there is a considerable improvement in the detection limit, the linear dynamic range and the deposition time, compared with the methods of adsorptive stripping voltammetry for the determination of copper. The developed method was validated by analysis of whole blood certified reference materials.