• 제목/요약/키워드: seismically isolated building

검색결과 20건 처리시간 0.027초

E-Isolation : High-performance Dynamic Testing Installation for Seismic Isolation Bearings and Damping Devices

  • Yoshikazu Takahashi;Toru Takeuchi;Shoichi Kishiki;Yozo Shinozaki;Masako Yoneda;Koichi Kajiwara;Akira Wada
    • 국제초고층학회논문집
    • /
    • 제12권1호
    • /
    • pp.93-105
    • /
    • 2023
  • Seismic isolation and vibration control techniques have been developed and put into practical use by challenging researchers and engineers worldwide since the latter half of the 20th century, and after more than 40 years, they are now used in thousands of buildings, private residences, highways in many seismic areas in the world. Seismic isolation and vibration control structures can keep the structures undamaged even in a major earthquake and realize continuous occupancy. This performance has come to be recognized not only by engineers but also by ordinary people, becoming indispensable for the formation of a resilient society. However, the dynamic characteristics of seismically isolated bearings, the key elements, are highly dependent on the size effect and rate-of-loading, especially under extreme loading conditions. Therefore, confirming the actual properties and performance of these bearings with full-scale specimens under prescribed dynamic loading protocols is essential. The number of testing facilities with such capacity is still limited and even though the existing labs in the US, China, Taiwan, Italy, etc. are conducting these tests, their dynamic loading test setups are subjected to friction generated by the large vertical loads and inertial force of the heavy table which affect the accuracy of measured forces. To solve this problem, the authors have proposed a direct reaction force measuring system that can eliminate the effects of friction and inertia forces, and a seismic isolation testing facility with the proposed system (E-isolation) will be completed on March 2023 in Japan. This test facility is designed to conduct not only dynamic loading tests of seismic isolation bearings and dampers but also to perform hybrid simulations of seismically isolated structures. In this paper, design details and the realization of this system into an actual dynamic testing facility are presented and the outcomes are discussed.

Seismic reliability assessment of base-isolated structures using artificial neural network: operation failure of sensitive equipment

  • Moeindarbari, Hesamaldin;Taghikhany, Touraj
    • Earthquakes and Structures
    • /
    • 제14권5호
    • /
    • pp.425-436
    • /
    • 2018
  • The design of seismically isolated structures considering the stochastic nature of excitations, base isolators' design parameters, and superstructure properties requires robust reliability analysis methods to calculate the failure probability of the entire system. Here, by applying artificial neural networks, we proposed a robust technique to accelerate the estimation of failure probability of equipped isolated structures. A three-story isolated building with susceptible facilities is considered as the analytical model to evaluate our technique. First, we employed a sensitivity analysis method to identify the critical sources of uncertainty. Next, we calculated the probability of failure for a particular set of random variables, performing Monte Carlo simulations based on the dynamic nonlinear time-history analysis. Finally, using a set of designed neural networks as a surrogate model for the structural analysis, we assessed once again the probability of the failure. Comparing the obtained results demonstrates that the surrogate model can attain precise estimations of the probability of failure. Moreover, our proposed approach significantly increases the computational efficiency corresponding to the dynamic time-history analysis of the structure.

정형 및 비정형 건물에 대한 비선형 면진장치의 적용 (Application of non-linear Seismic Isolators in Regular and Irregular Buildings)

  • 김대곤;이동근;정재;남궁계홍
    • 한국지진공학회논문집
    • /
    • 제5권1호
    • /
    • pp.37-44
    • /
    • 2001
  • 면진기술은 주로 저층 구조물의 내진설계에서 적용되는 방법으로 건물과 기초사이에 면진장치를 설치하여 상부로 전달되는 지진하중을 효과적으로 감소시킨다. 그러나 이 방법은 중.고층 구조물에 그대로 적용하기에는 여러 가지 기술적 문제가 따르므로, 구보물의 중간층 일부를 분리시켜 상부로 전달되는 지진력을 감소시킬 수 있을 것이다. 본 노문에서는 저층 뿐만 아니라, 중.고층 정형구조물의 주상복합건물과 같은 비정형 구조물에 대하여 구조물의 중간층 일부를 비선형 면진장치로 면진시키고 그 효과를 분석하였다. 이러한 중간층 면진 구조물의 경우, 고정기초 구조물에 비하여 적은 층간변위나 층전단력이 발생하였으며, 특히 주상복합건물에서 상당한 효과를 볼 수 있었다.

  • PDF

MR댐퍼를 이용한 지진하중을 받는 지진격리 벤치마크 구조물의 신경망제어 (Neuro-Control of Seismically Excited Base-Isolated Benchmark Structure using MR Damper)

  • 이헌재;조상원;오주원;이인원
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.463-470
    • /
    • 2006
  • 이 논문에서는 신경망 제어기와 MR 댐퍼를 이용하여 지진하중을 받는 지진격리 벤치마크 구조물의 응답 감소를 위한 반능동 제어방법이 제안되었다. 제안방법 중 신경망 제어기에는 적절한 제어력을 산출하기 위해 가격함수를 기반으로한 학습 알고리즘과 간편한 민감도 계산기법이 도입되었다. MR 댐퍼가 계산되어진 제어력과 비슷한 제어력을 낼 수 있도록 clipped 알고리즘을 이용하였고, 제안된 반능동 신경망 제어방법이 지진격리 장치가 설치된 벤치마크 구조물에 적용되었다. 수치해석에서는 벤치마크 문제를 정의한 논문에서 제공된 수동제어방법이나 예시제어방법과 제안 방법의 제어성능을 비교하였다. 수치해석 결과 제안방법은 지하 변위를 약간 증가시키지만, 각층의 가속도, base shear, building corner drift 등을 매우 효과적으로 줄이는 것으로 판명되었다.

  • PDF

Assessing the effect of inherent nonlinearities in the analysis and design of a low-rise base isolated steel building

  • Varnavaa, Varnavas;Komodromos, Petros
    • Earthquakes and Structures
    • /
    • 제5권5호
    • /
    • pp.499-526
    • /
    • 2013
  • Seismic isolation is an effective method for the protection of buildings and their contents during strong earthquakes. This research work aims to assess the appropriateness of the linear and nonlinear models that can be used in the analysis of typical low-rise base isolated steel buildings, taking into account the inherent nonlinearities of the isolation system as well as the potential nonlinearities of the superstructure in case of strong ground motions. The accuracy of the linearization of the isolator properties according to Eurocode 8 is evaluated comparatively with the corresponding response that can be obtained through the nonlinear hysteretic Bouc-Wen constitutive model. The suitability of the linearized model in the determination of the size of the required seismic gap is assessed, under various earthquake intensities, considering relevant methods that are provided by building codes. Furthermore, the validity of the common assumption of elastic behavior for the superstructure is explored and the alteration of the structural response due to the inelastic deformations of the superstructure as a consequence of potential collision to the restraining moat wall is studied. The usage of a nonlinear model for the isolation system is found to be necessary in order to achieve a sufficiently accurate assessment of the structural response and a reliable estimation of the required width of the provided seismic gap. Moreover, the simulations reveal that the superstructure's inelasticity should be taken into account, especially if the response of the structure under high magnitude earthquakes is investigated. The consideration of the inelasticity of the superstructure is also recommended in studies of structural collision of seismically isolated structures to the surrounding moat wall, since it affects the response.

Effectiveness of non-linear fluid viscous dampers in seismically isolated buildings

  • Guler, Elif;Alhan, Cenk
    • Earthquakes and Structures
    • /
    • 제17권2호
    • /
    • pp.191-204
    • /
    • 2019
  • Near-field earthquake records including long-period high-amplitude velocity pulses can cause large isolation system displacements leading to buckling or rupture of isolators. In such cases, providing supplemental damping in the isolation system has been proposed as a solution. However, it is known that linear viscous dampers can reduce base displacements in case of near-field earthquakes but at the potential expense of increased superstructure response in case of far-field earthquakes. But can non-linear dampers with different levels of non-linearity offer a superior seismic performance? In order to answer this question, the effectiveness of non-linear viscous dampers in reducing isolator displacements and its effects on the superstructure response are investigated. A comparison with linear viscous dampers via time history analysis is done using a base-isolated benchmark building model under historical near-field and far-field earthquake records for a wide range of different levels of non-linearity and supplemental damping. The results show that the non-linearity level and the amount of supplemental damping play important roles in reducing base displacements effectively. Although use of non-linear supplemental dampers may cause superstructure response amplification in case of far-field earthquakes, this negative effect may be avoided or even reduced by using appropriate combinations of non-linearity level and supplemental damping.

고감쇠고무 적층받침의 경년열화를 고려한 원전구조물의 지진응답 (Seismic Response of Seismically-Isolated Nuclear Power Plants considering Age-related Degradation of High Damping Rubber Bearing)

  • 박준희;전영선;최인길
    • 한국전산구조공학회논문집
    • /
    • 제26권2호
    • /
    • pp.131-138
    • /
    • 2013
  • 면진장치는 상부구조물의 지진력을 감소시키는데 크게 기여하지만, 고감쇠고무 적층받침에 사용되는 고무재료는 시간이 경과함에 따라 열화되어 상부구조물의 동특성과 기기들의 지진응답에 영향을 줄 수 있다. 따라서 면진장치의 경년열화를 고려한 구조물의 지진응답을 분석하는 연구가 필요하다. 본 연구에서는 기존 문헌을 통하여 분석된 고무의 경년열화 특성을 사용하여 면진장치를 모델링하였다. 면진된 원전의 지진응답을 평가하기 위하여 격납건물과 보조건물을 대상 구조물로 선정하고, 진동수 성분이 다양한 입력지진동을 사용하여 구조물의 고유진동수, 최대지진응답, 층응답스펙트럼을 시간의 경과에 따라 분석하였다. 해석결과에 의하면 면진장치의 경년열화에 의하여 지진응답이 소폭 증가하였으며, 면진장치가 설치된 후 20년까지 지진응답의 증가율이 크게 나타나므로 이 기간에 상세한 검사가 시행되어야 할 것이다.

KALIMER-600 지진해석모델 개발 및 시간이력 지진응답해석 (Development of Seismic Analysis Model and Time History Analysis for KALIMER-600)

  • 구경회;이재한
    • 한국지진공학회논문집
    • /
    • 제11권3호
    • /
    • pp.73-86
    • /
    • 2007
  • 본 논문에서는 제4세대 소듐냉각고속로(Sodium-Cooled Fast Reactor)의 후보 노형으로 선정된 KALIMER-600에 대한 단순 지진해석모델을 개발하고 시간이력 지진응답해석을 수행하여 수평 면진설계(Seismic Isolation) 기술이 적용된 원자로건물의 주요기기 및 구조물에서의 지진응답 성능을 분석하였다. 개발된 단순 지진해석모델은 원자로건물, 원자로시스템, 주요 기기, 중간 열전달계통 배관, 그리고 면진장치를 포함하며 각각은 상세 유한요소해석을 통한 동특성 비교검증을 통하여 정확성을 검증하였다. 안전정지기준 0.3g의 설계인공지진 하중에 대한 시간이력 지진응답해석을 수행하여 면진설계와 비면진 설계조건에 따른 원자로 주요 부위에서의 층응답스펙트럼을 비교분석한 결과 KALIMER-600의 면진성능이 우수한 것으로 나타났다.

우리나라의 면진 및 진동제어 (Application of Seismic Isolation and Vibration Control in Korea)

  • 이동근;김태호
    • 한국지진공학회논문집
    • /
    • 제10권6호
    • /
    • pp.67-77
    • /
    • 2006
  • 우리나라는 일본이나 미국의 서부지역처럼 지진위험도가 매우 높은 지역이 아니다. 그러므로 1988년에 처음으로 내진설계기준이 도입될 때까지 거의 대부분의 구조물들이 지진의 영향을 고려하지 않고 설계되었다. 원자력발전소나 액화천연가스(LNG) 저장 탱크 등의 구조물에 면진 기술이 적용되었지만 우리나라의 기술자들은 면진이나 진동제어에 대해서는 별로 관심이 없었으며 이러한 것은 강진지역에서나 필요한 기술로 생각하였다. 그러나 이러한 기술은 우리나라와 같은 약진지역에서 더 효과적으로 지진과 바람의 영향을 저감시킬 수가 있는 것이다. 다행히 근래에는 극히 소수이기는 하지만 우리나라에서도 면진과 진동제어 기술을 적용하는 교량이나 건물의 수가 점차 늘어나고 있어서 지진이나 바람 등의 영향에 대하여 보다 적극적인 대처를 하기 시작하였다. 그러나 건축 구조물의 면진이나 진동제어에 대하여 설계기준이 제대로 마련되어 있지 않아서 이러한 기술을 적용하는데 실제적으로는 많은 어려움을 겪기도 하는 것이 현실이다. 따라서 우리나라에서도 이러한 기술을 적용할 수 있는 법적 근거를 마련하는 것이 시급한 과제라고 볼 수 있다.

지진격리장치를 적용한 복층구조파이핑 시스템의 내진성능평가 (Seismic Performance Evaluation of Multi-Story Piping Systems using Triple Friction Pendulum Bearing)

  • 류용희;주부석;손호영
    • 한국재난정보학회 논문집
    • /
    • 제14권4호
    • /
    • pp.450-457
    • /
    • 2018
  • 연구목적: 2016년 9월 경주 이후 구조물 및 비구조물의 지진 안전성 및 내진성능에 관한 문제가 이슈화 되고 있으며, 특히 배관 시스템의 경우 구조요소 보다 지진 발생시 내진성능에 있어서 취약하다고 볼 수 있다. 스프링클러 배관 시스템과 같은 비구조적 구성요소의 손상으로 인해 지진 발생 및 이후에 상당한 경제적 손실이나 생명 손실을 초래 할 수 있다. 연구방법: 본 연구는 Triple Friction Pendulum Bearings (TPBs)을 설치한 건물 배관 시스템을 이용한 소방 배관 시스템의 내진성능평가를 제시한다. Kobe, Kocaeli, GyeongJu 지진을 고려하여 지반 운동의 불확실성을 고려하였다. 연구결과: 빌딩 시스템과 파이핑 시스템의 첫 번째 모드는 각각 약 5.8Hz와 약 2.742Hz로 나타났으며, 또한 TPBs 시스템이 적용된 배관 시스템의 최대 변위는 Kobe, Kocaeli 및 GyeongJu 지진의 경우 각각 49%, 14.4%, 21.5%가 감소한 것으로 나타났다. 결론: 따라서 건물 배관 시스템에서 지진 격리 시스템을 사용하면 지진이 심할 때 TPB가 없는 일반적으로 설치된 걸물 배관 시스템보다 지진 위험을 줄일 수 있다.