• 제목/요약/키워드: seismic performance enhancement

검색결과 67건 처리시간 0.02초

신보강재로 보수 보강한 기둥의 구조 성능 개선 (Structural Performance Enhancement of Seismic Retrofitted Column Using New Reinforcing Materials)

  • 오창학;한상환;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.121-128
    • /
    • 2001
  • Reinforced concrete frame buildings in regions of low to moderate seismicity are typically designed only for gravity loads with non-seismic detailing provisions of the code. These buildings possess strong beam-weak column, which brings about the brittle structural performance like the column sidesway failure mechanism during the strong lateral load. The objective of this paper is to enhance the column strength and deformation capacity for reconfiguring the structural failure mode by averting a column soft-story collapse and moving to a more ductile beam-sides way mechanism suing new reinforcing materials. Aramid fiber sheet and reinforcing rod-composite materials was used for this purpose. The column was modeled by the 2/3 scale experimental specimen retested. According to the concept of the capacity design, the damaged column was strengthened by the column jacketing using new reinfocing materials such as rod-composite materials. In conclusion, the improvement of the flexural strength is observed and the capacity of the energy dissipation and the ductility is enhanced, too.

  • PDF

Seismic protection of LNG tanks with reliability based optimally designed combined rubber isolator and friction damper

  • Khansefid, Ali;Maghsoudi-Barmi, Ali;Khaloo, Alireza
    • Earthquakes and Structures
    • /
    • 제16권5호
    • /
    • pp.523-532
    • /
    • 2019
  • Different types of gas reservoir such as Liquid Natural Gas (LNG) are among the strategic infrastructures, and have great importance for any government or their private owners. To keep the tank and its contents safe during earthquakes especially if the contents are of hazardous or flammable materials; using seismic protection systems such as base isolator can be considered as an effective solution. However, the major deficiency of this system can be the large deformation in the isolation level which may lead to the failure of bearing system. In this paper, as a solution, the efficacy of an optimally designed combined vibration control system, the combined laminated rubber isolator and rotational friction damper, is investigated to evaluate the enhancement of an existing metal tank response under both far- and near-field earthquakes. Responses like impulsive and convective accelerations, base shear, and sloshing height are studied herein. The probabilistic framework is used to consider the uncertainties in the structural modeling, as well as record-to-record variability. Due to the high calculation cost of probabilistic methods, a simplified structural model is used. By using the Mont-Carlo simulation approach, it is revealed that this combined isolation system is a highly reliable system which provides considerable enhancement in the performance of reservoir, not only leads to the reduction of probability of catastrophic failure of the tank but also decrease the reservoir damage during the earthquake. Moreover, the relative displacement of the isolation level is controlled very well by this combined system.

마찰형 감쇠장치가 설치된 실물크기 3층 철골프레임의 진동대 실험 (Shaking Table Test of a Full Scale 3 Story Steel Frame with Friction Dampers)

  • 배춘희;김연환;이상현;박영필
    • 한국소음진동공학회논문집
    • /
    • 제17권9호
    • /
    • pp.862-873
    • /
    • 2007
  • Energy dissipation devices can be considered as an alternative for the seismic performance enhancement of existing structures based on the strengthened seismic design code. In this study, seismic response mitigation effects of friction dampers are investigated through the shaking table test of a full scale 3 story building structure. Frist, the bilinear force-displacement relationship of a structure-brace-friction damper system and the effect of brace-friction damper on the increase of frequency and damping ratio are identified. Second, frequency, displacement, and torque dependent characteristics of the friction damper are investigated by using harmonic load excitation tests. Finally, the shaking table tests are performed for a full scale 3 story steel frame. System identification results using random signal excitation indicated that brace-friction damper increased structural damping ratio and frequency, and El Centro earthquake test showed that brace-friction damper reduced the peak displacement and acceleration significantly. In particular, it was observed that the damping effect due to friction damper becomed obvious when the structure was excited by more intensive load causing frequent slippage of the friction dampers.

유리섬유 보강 원형 철근콘크리트 교각의 내진성능에 관한 준정적 실험연구 (Quasi-Static Test for Seismic Performance of Circular R.C. Bridge Piers Before and After Retrofitting)

  • 정영수;이강균;한기훈;이대형
    • 콘크리트학회논문집
    • /
    • 제11권5호
    • /
    • pp.107-118
    • /
    • 1999
  • 10 RC bridge piers have been made on a 1/3.4 scale model, and six piers of them were retrofitted with glassfiber. The have been tested in the quasi-static cyclic load so as to investigate their seismic enhancement before and after retrofitting with glassfibers. The objective of this experimental study is to investigate how to strength the ductility of reinforced concrete bridge piers which have been nonseismically designed and constructed in Korea before 1992. Important test parameters are axial load, load pattern, retrofit type. Glassfiber sheets were used for retrofitting in the plastic hinge region of concrete piers. The nonlinear behavior of bridge columns have been evaluated through their yield and ultimate strength, energy dissipation, displacement ductility and load-deflection characteristics under quasi-static cyclic loads. It can be concluded from the test that concrete piers strengthened with glassfibers have been enhanced for their ductile behavior by approximate 50%.

동조액체 감쇠기를 설치한 철근콘크리트 축소모델의 진동대 실험 (Shaking Table Test of Small Scale RC Structure with Tuned Liquid Damper)

  • 우성식;이상현;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.113-116
    • /
    • 2005
  • In this study, in order to. investigate the effectiveness af tuned liquid damper (TLD) for the seismic performance enhancement af the existing reinforced concrete (RC) apartment structure which is nat seismically designed, shaking table test was conducted for the small scale five stary RC structure with TLD. TLD model was constructed to. have the frequency tuned to. the first modal frequency af the structure, $2\%$ mass ratio. af the first modal mass, and 0.08 liquid depth ratio. White noise with $0.2\~5Hz$ frequency bandwidth tests were performed using the shaking table at Korea Institute af Machinery and Materials, and the displacement and absolute acceleration af each floor were measured. Test results indicate that mare than $30\%$ seismic responses reduction can be achieved using TLD for RC structure under white noise.

  • PDF

패널파괴형 철골 커플링 보-벽체 접합부의 내진거동 (Seismic Behavior of Steel Coupling Beam-Wall Connection with Pane Shear Failure)

  • 박완신;한민기;김선우;황선경;양일승;윤현도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.431-434
    • /
    • 2005
  • In the past decade, various experimental programmes were undertaken to address the lack of information on the interaction between steel coupling beams and reinforced concrete shear wall in a hybrid coupled shear wall system. In this paper, the seismic performance of steel coupling beam-wall connections in a hybrid coupled shear wall system is examined through results of an experimental research programme where three 2/3-scale specimens were tested under cyclic loading. The test variables included the reinforcement details that confer a ductile behaviour on the steel coupling beam-wall connection, i.e., the face bearing plates and the horizontal ties in the panel region of steel coupling beam-wall connections. Panel shear strength reflects enhancement achieved through mobilization of the reinforced concrete panel using face bearing plates and/or horizontal ties in the panel region of steel coupling beam-wall connections.

  • PDF

고강도 철근콘크리트 보-기둥 접합부의 내진성능 개선에 관한 실험적 연구 (Improvement of Earthquake-Resistant Performance of R/C Beam-Column Joint Constructed with High-Strength Concrete Subjected to Cyclic Loading)

  • 하기주;김진근;정란
    • 콘크리트학회지
    • /
    • 제4권1호
    • /
    • pp.135-145
    • /
    • 1992
  • 최근 철근콘크리트 건축물의 초고층화 추세에 따라 건축물의 설계시에 고강도의 건설재료, 부재단면의 축소, 직경이 큰 철근의 사용이 요구되고 있다. 이에 따라 구조물의 다른 부위에 비하여 접합부 영역의 응력 집중현상이 커지고, 철근콘크리트 구조물에 고강도 콘크리트를 적용하므로써 고정하중의 감소, 부재단면의 축소, 부재내력의 증대, 장 스팬 구조물의 축소 가능, 경제성의 향상을 가져올 수 있는 장점으로 인하여, 철근콘크리트 구조물에 고강도 콘크리트의 이용은 더욱 증대할 것으로 예상된다. 그러나 고강도콘크리트는 보통 콘크리트와 다른 특성, 특히 최대내력이후의 강도저하가 현저하고 파괴성상이 취성적인 성질을 지니고 있으므로 실제 구조물에 적용하기 앞서 구조물의 안전성 측면에서 부재 실험을 통하여 정확한 역학적 특성을 규명할 필요가 있다. 따라서 본 연구에서는 반복 주기하중을 받는 고강도 철근콘크리트 보-기둥 접합부의 거동을 파악하고, 접합부의 내진성능 개선을 위한 새로운 설계방법을 실제 초고층 철근콘크리트 건축물의 설계를 위한 기초 자료로 제시하였다.

소규모 철골조건축물을 위한 약축방향 노출형 주각부의 내진성능 향상 (Seismic Performance Enhancement of Exposed Column-base Plate Weak-axis Connections for Small-Sized Steel Buildings)

  • 유영찬
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권5호
    • /
    • pp.1-12
    • /
    • 2019
  • 소규모 철골조건축물의 접합상세에 대한 현장조사에 따르면 지진하중에 의한 횡적 안전성 및 안정성 확보가 불충분할 것으로 예상되는 임의 접합상세가 현장에서 적용되는 것으로 조사되었다. 이에 따라 본 연구에서는 소규모 강구조건축물의 노출형 주각부 약축 연결부의 반복이력 실험을 통해 문제점을 분석하고, 이를 바탕으로 내진성능을 향상시킬 수 있는 접합상세의 개발을 위해 일련의 실험연구를 수행하였다. 본 실험결과에 의하면, 국내에서 흔히 사용되는 노출형 주각부 약축방향 접합부의 이력거동은 앵커볼트가 콘크리트로부터 점진적으로 인발됨에 따라 베이스플레이트와 앵커볼트사이에 이격거리가 누적되어 하중역전구간에서 "Rocking" 현상이 발생되어 내진성능이 매우 낮은 것으로 조사되었다. 이와 같은 문제점을 개선하기 위하하여 앵커볼트의 콘크리트에 대한 부착 유/무와 개수 및 배열형태 등을 변수로 한 성능개선 실험체에 대한 일련의 반복 이력 실험을 수행하였으며, 최종적으로 소규모철골조 건축물의 노출형 주각부에 고강도 전산볼트형 앵커볼트를 8개로 3열로 배치하는 상세의 적용을 통하여 하중지지능력과 에너지분산능력 측면에서 내진성능이 크게 개선된 것을 확인할 수 있었다.

S형 스트럿 강재 댐퍼 보강에 의한 RC 골조의 내진성능 향상 (Seismic Resisting Capacity Enhancement by S Type Strut Steel Damper Strengthening)

  • 이현호
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.43-50
    • /
    • 2018
  • The purpose of this study is to improve the seismic performance of RC framed buildings such as piloti buildings and school facilities. For this purpose, a half size RC frame specimen (SFD) was made and the inside of frame was reinforced with steel frame and S type strut steel damper. The experimental results are compared with those of the previous studies under the same conditions. The comparative specimens are non-reinforced specimen (BF) and damper reinforced specimen (AFD) that confined the column with an aramid sheet. As a result of comparing the maximum strength, stiffness degradation and energy dissipation capacity, SFD specimen was evaluated to be better than comparative specimens. According to the experimental results and FE analysis results, it was confirmed that the shear deformation was concentrated in the steel damper. And it was showed that cracks were concentrated at the upper and lower ends of the strut of the S type damper, and the final failure was observed at struts. From this, it was verified that the steel damper appropriately dissipates energy due to the lateral load.

X형 감쇠시스템을 위한 복원성 점성 감쇠기 성능 실험 및 수치모형 개발 (Performance Test and Numerical Model Development of Restoring Viscous Damper for X-type Damper System)

  • 김다위;박장호;옥승용;박원석
    • 한국안전학회지
    • /
    • 제31권6호
    • /
    • pp.52-57
    • /
    • 2016
  • In this study, a restoring viscous damper is introduced for X-type damper system which is designed for the seismic response control of large spatial structures. A nonlinear numerical model for its behavior is developed using the result of dynamic loading tests. The X-type damper system is composed of restoring viscous dampers and connecting devices such as adjustable wire bracing, where the damping capacity of the system is controllable by changing the number of the dampers. The restoring viscous damper is devised to exert main damping force in tension direction, which is effective to prevent the buckling of bracing subjected to compressive axial force. To evaluate the performance of the proposed damper, dynamic cyclic loading tests are performed by using manufactured dampers at full scale. In order to construct the numerical model of the damper system, its model parameters are first identified using a nonlinear curve fitting method with the test data. The numerical simulations are then performed to validate the accuracy of the numerical model in comparison with the experimental test results. It is expected that the proposed system is effectively applicable to various building structures for seismic performance enhancement.