• Title/Summary/Keyword: seismic factors

Search Result 421, Processing Time 0.023 seconds

Moment-curvature hysteresis model of angle steel frame confined concrete columns

  • Rong, Chong;Tian, Wenkai;Shi, Qingxuan;Wang, Bin;Shah, Abid Ali
    • Structural Engineering and Mechanics
    • /
    • v.83 no.1
    • /
    • pp.19-29
    • /
    • 2022
  • The angle steel frame confined concrete columns (ASFCs) are an emerging form of hybrid columns, which comprise an inner angle steel frame and a concrete column. The inner angle steel frame can provide axial bearing capacity and well confining effect for composite columns. This paper presents the experimental and theoretical studies on the seismic behaviour of ASFCs. The experimental study of the 6 test specimens is presented, based on the previous study of the authors. The theoretical study includes two parts. One part establishes the section analysis model, and it uses to analyze section axial force-moment-curvature. Another part establishes the section moment-curvature hysteresis model. The test and analysis results show that the axial compression ratio and the assembling of steel slabs influence the local buckling of the angle steel. The three factors (axial compression ratio, content of angle steel and confining effect) have important effects on the seismic behaviour of ASFCs. And the theoretical model can provide reasonably accurate predictions and apply in section analysis of ASFCs.

Comparison of different codes using fragility analysis of a typical school building in Türkiye: Case study of Bingöl Çeltiksuyu

  • Ibrahim Baran Karasin;Mehmet Emin Oncua
    • Earthquakes and Structures
    • /
    • v.25 no.4
    • /
    • pp.235-247
    • /
    • 2023
  • Bingöl, a city in eastern Türkiye, is located at a very close distance to the Karlıova Region which is a junction point of the North Anatolian Fault Zone and Eastern Anatolian Fault Zone. By bilateral step over of North Anatolian Fault Zone and Eastern Anatolian Fault Zone each other there occurred NorthWest-SouthEast extended right-lateral and NorthEast-SouthWest extended left-lateral fault zones. In this paper, a typical school building located in Bingöl Çeltiksuyu was selected as the case study. Information on the school building and Bingöl Earthquake (2003) have been given in the paper. This study aimed to determine the fragility curves of the school building according to HAZUS 2022, Turkish Seismic Codes 1998, 2007 and 2018. These codes have been introduced in terms of damage limits. Incremental dynamic analysis is a parametric analysis method that has recently emerged in several different forms to estimate more thoroughly structural performance under seismic loads. Fragility analysis is commonly using to estimate the damage probability of buildings. Incremental Dynamic Analysis have performed, and 1295 Incremental Dynamic Analysis output was evaluated to obtain fragility curves. 20 different ground motion records have been selected with magnitudes between 5.6M and 7.6M. Scaling factors of these ground motions were selected between 0.1g and 2g. Comparison has been made between HAZUS 2022 and Turkish Seismic Codes 1998, 2007 and 2018 in terms of damage states and how they affected fragility curves. TSC 1998 has more conservative strictions along with TSC 2018 than TSC2007 and HAZUS moderate and extensive damage limits.

A GIS-Based Seismic Vulnerability Mapping and Assessment Using AHP: A Case Study of Gyeongju, Korea (GIS 기반 AHP를 이용한 지진 취약성 지도제작 및 평가: 경주시를 중심으로)

  • Han, Jihye;Kim, Jinsoo
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.2
    • /
    • pp.217-228
    • /
    • 2019
  • In this study, a seismic vulnerability map of Gyeongju city, where the 9.12 Gyeongju earthquake occurred, was produced and evaluated using analytic hierarchy process(AHP) and geographic information system (GIS). Geotechnical, physical, social, structural, and capacity factors were selected as the main indicators and 18 sub-indicators to construct a spatial database. Weights derived using the AHP were applied to the 18 sub-indicators, which generated a vulnerability map of the five main indicators. After weighting the five generated maps, we created seismic vulnerability maps by overlaying each of the five maps. The seismic vulnerability map was classified into five zones, i.e., very high, high, moderate, low, and safe. For seismic vulnerability, the results indicated that 3% of Gyeongju area is characterized as having very high vulnerability, while 19% was characterized as safe. Based on district standards, Jungbu-dong, Hwangoh-dong, Hwangseong-dong, Seonggeon-dong, and Dongcheon-dong were high-risk areas, and Bodeok-dong, Gangdong-myeon, Yangbuk-myeon, Yangnam-myeon, and Oedong-eup were characterized as safe areas. The seismic vulnerability map produced in this study could possibly be used to minimize damage caused by earthquakes and could be used as a reference when establishing policies.

Full-scale Shaking Table Test of Uninterruptible Power Supply Installed in 2-stories Steel Structure (2층 철골 구조물에 설치된 무정전전원장치의 실규모 진동대 실험연구)

  • Lee, Ji-Eon;Park, Won-Il;Choi, Kyoung-Kyu;Oh, Sang-Hoon;Park, Hoon-Yang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.29-38
    • /
    • 2022
  • In this study, the shaking table tests were carried out on six types of non-structural elements installed on a full-scale two-story steel structure. The shaking table tests were performed for non-structural elements with and without seismic isolators. In this study, the seismic performance of Uninterruptible Power Supply (UPS) specimens was tested and investigated. Non-seismic details were composed of conventional channel section steel beams, and the seismic isolators were composed of high damping rubber bearing (HDRB) and wire isolator. The input acceleration time histories were artificially generated to satisfy the requirements proposed by the ICC-ES AC156 code. Based on the test results, the damage and dynamic characteristics of the UPS with the seismic isolator were investigated in terms of the natural frequency, damping ratio, acceleration time history responses, dynamic amplification factors, and relative displacements. The results from the shaking table showed that the dynamic characteristics of the UPS including the acceleration response were significantly improved when using the seismic isolator.

Response Modification Factors of Inverted V-type Special Concentrically Braced Frames (역V형 특수가새골조의 반응수정계수)

  • 김진구;남광희
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.29-37
    • /
    • 2004
  • The overstrength factor and the ductility factor are the two important factors that determine response modification factors used in current seismic codes, In this paper the overstrength and ductility factors of special concentric braced frames are determined by performing pushover analysis of model structures with various stories and span lengths. and by using those factors the response modification factors are obtained. According to the analysis results. the overstrength and the ductility factors are larger than the values proposed by the codes in low-rise structures. and the opposite is true in medium to high-rise structures, It is also found that the factors increase as the height of structures decreases and the span length increases.

The Site Effect of the Broadband Seismic Stations in Korea (국내 광대역 지진 관측소의 부지효과)

  • Wee, Soung-Hoon;Kim, Sung-Kyun
    • Economic and Environmental Geology
    • /
    • v.41 no.2
    • /
    • pp.225-242
    • /
    • 2008
  • The site effect for 23 broadband seismic stations in the southern Korean Peninsula was estimated by using the spectral ratio of coda waves. In principle, the site effect means the pure amplification below the station excluding effects of seismic source and attenuation in the wave transmission. However, the site effect determined in this study is equivalent with the relative site amplification factor to the mean amplification for all stations. A total of 500 three-component seismograms from 35 earthquakes, of which magnitude ranged from 2.5 to 5.1 occurred from January, 2001 to January, 2007 was used to obtain the site amplification factor. The site amplification factors were estimated for the frequency bands centered at 0.2, 0.5, 1, 2, 5, 10, 15, and 20 Hz. It was found that the factors for two horizontal components of transverse and radial records were concordant with each other in the all frequency bands. However, the factor for the vertical component was found to be systematically lower than those for two horizontal components. The factors obtained in the low frequency band below 2 Hz ranged from 0.5 to 1.5 in all seismic stations except for KMA and KIGAM stations in Bagryeongdo (BRD1 and BRD2) of which factor showed high value above 1.5. Some stations such as SEO, SNU, HKU, NPR, and GKPI showed high value above 1.5 in the high frequency band from 5 to 20 Hz. Especially, the factors of GKP1 station represented extremely high value ranging from 1.8 to 7.8. Also, the factors for stations of KWJ, SND, and ULJ showed low value below 0.5. The spatial distribution for the relative amplification factor represented a tendency of being approximately lower in north-eastern area than south-western area in the southern Korean Peninsula.

Response Modification Factors of Inverted V-type Ordinary Concentrically Braced Frames (역V형 보통가새골조의 반응수정계수)

  • Kim, Jin-Koo;Nam, Kwang-Hee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.3
    • /
    • pp.53-62
    • /
    • 2004
  • In this paper the overstrength factors, ductility factors, and response modification factors of ordinary concentric braced frames designed in accordance with a current seismic design code are determined by performing pushover analysis. According to the analysis results, the overstrength and the response modification factors turn out to be larger than the values regulated in the codes in most model structures. However if the braces are reinforced by BRB or zipper columns, the overstrength factors and response modification factors turn out to increase significantly.

A Study on the Conventional Liquefaction Analysis and Application to Korean Liquefaction Hazard Zones (기존의 액상화 평가기법 밀 그 적용성에 관한 연구)

  • 박인준;신윤섭;최재순;김수일
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.431-438
    • /
    • 1999
  • An assessment of liquefaction potential is made in principle by comparing the shear stress induced by earthquake to the liquefaction strength of the soil. In this study, a modified method based on Seed and Idriss theory is developed for evaluating liquefaction potential. The shear stress in the ground can be evaluated with seismic response analysis and the liquefaction strength of the soil can be investigated by using cyclic triaxial tests. The cyclic triaxial tests are conducted in two different conditions in order to investigate the factors affecting liquefaction strength such as cyclic shear stress amplitude and relative density. And performance of the modified method in practical examples is demonstrated by applying it to liquefaction analysis of artificial zones with dimensions and material properties similar to those in a typical field. From the result, the modified method for assessing liquefaction potential can successfully evaluate the safety factor under moderate magnitude(M=6.5) of earthquake.

  • PDF

Review of Seismic Analysis Method for Free Standing High Density Spent Fuel Racks of PWR Plant (가압경수형 발전소 자립형 고밀도 핵연료 저장랙의 지진해석 방법에 대한 검토)

  • 신태명;김범식;손갑헌
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.10a
    • /
    • pp.183-190
    • /
    • 1994
  • The paper provides a review of the analysis methods currently being used to perform seismic analysis of free standing high density spent fuel storage racks for PWR. On the basis of the analysis techniques obtained by KAERI from the design experience of Yonggwang unit 3&4 and Ulchin unit 3&4, the analysis procedure and modeling methods are discussed. The analysis of free standing fuel racks requires consideration of complex phenomena such as hydrodynamic coupling, impact through gap between fuel assembly and poison box and racks, frictional effect, rigid body sliding and tipping and etc. The present modeling of these factors is reviewed in comparison with the recommendation of regulatory group. Further improvement of analysis method and the current issues for the development are discussed.

  • PDF

Analysis of Amplication Factor of Response Spectrum using Strong Ground Motions Compatible to the Domestic Seismotectonic Characteristics (유사 강지진동을 이용한 지반응답의 Amplication Factor 스펙트럼 분석)

  • 김준경
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.88-93
    • /
    • 1997
  • Amplication factor spectrum has been obtained and compared with standard Response Spectrum using the observed strong ground motions database. The observed ground motions from the Miramichi, Nahanni, Saguenay and New Madrid Earthquake (vertical component 19. horizontal component 36). which are estimated to represent domestic seismotectonic characteristics such as seismic source, attenuation, and site effect, are used for the analysis of amplication factor spectrum. Amplication factor has been calculated using both observed peak values and results from responses to the observed horizontal and vertical ground motions. The comparison shows that the amplication factors resultant from this study exceeds those of Standard Response Spectrum at relatively higher frequencies. The results implie that the characteristics of the seismic strong ground motion which may represent the domestic seismotectonic characteristics differs from those of Standard Response Spectrum, which are resultant from the strong ground motions observed mainly at the westem United States.

  • PDF