• Title/Summary/Keyword: seismic factors

Search Result 427, Processing Time 0.023 seconds

Focal Depth Factors in the PSH Analysis

  • Kim, Jun-Kyoung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.3
    • /
    • pp.83-86
    • /
    • 1998
  • The results from the Individual Plant Examination of External Event of Yonggwyang nuclear power plants, unit 3 & 4, in Korea have shown that the high degree of diversities of the experts' opinions on seismicity and attenuation models is su, pp.sed to be generic cause of uncertainty of APEs(annual exceedance probability) in the PAHA(probabilistic seismic hazard analysis). This study investigated the sensitivity of the focal depth, which is one of the most uncertain seismicity parameters in Korea, Significant differences in resultant values of annual exceedance probabilities and much more symmetrical shape of the resultant PDFs(probability density functions), in case of consideration of focal depth, are found. These two results suggest that, even for the same seismic input data set including the seismicity models and ground motion attenuation models, to consider focal depth additionally for probabilistic seismic hazard analysis evaluation makes significant influence on the distributions of uncertainties and probabilities of exceedance per year for the whole ranges of seismic hazard levels. These facts suggest that it is necessary to derive focal depth parameter more effectively from the historical and instrumental documents on earthquake phenomena in Koran Peninsula for the future study of PSHA.

  • PDF

Analysis of Seismic Performance of Slim Flat Plate System in High-rise Hybrid Structural System (슬림형 바닥시스템을 이용한 고층 복합구조의 내진성능에 관한 해석적 연구)

  • Ha Gee Joo;Park Hyo Sun;Park Joung Hyen;Choi Kyung Ryeol;Kim Dae Joung;Jung Jea Kwang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.77-80
    • /
    • 2005
  • Recently the construction of high-rise hybrid type building is progressively increased as the social demands. It is significantly important factors such as economy, the safety of structure, and the flexibility of internal space. Therefore new hybrid structural system, using slim flat plate system, is also required to be attained the reduction of story height, the flexibility and efficient use of space. The most suitable structural system is ,with the economy and flexibility, flat plate system in high-rise hybrid type building. But it was focused in the seismic performance for high performance flat plate system in high-rise hybrid type building. Therefore, in the study, to develop the new flat-plate system with high ductile, durable, good performance for the applications. It was evaluated the seismic performance in the critical region of slab-column connection. And then high performance flat plate system, designed by the economy and safety, was developed as a new technique in the application of high-rise hybrid type building.

  • PDF

Performance-based design of tall buildings for wind load and application of response modification factor

  • Alinejad, Hamidreza;Jeong, Seung Yong;Kang, Thomas H.K.
    • Wind and Structures
    • /
    • v.31 no.2
    • /
    • pp.153-164
    • /
    • 2020
  • In the design of buildings, lateral loading is one of the most important factors considered by structural designers. The concept of performance-based design (PBD) is well developed for seismic load. Whereas, wind design is mainly based on elastic analysis for both serviceability and strength. For tall buildings subject to extreme wind load, inelastic behavior and application of the concept of PBD bear consideration. For seismic design, current practice primarily presumes inelastic behavior of the structure and that energy is dissipated by plastic deformation. However, due to analysis complexity and computational cost, calculations used to predict inelastic behavior are often performed using elastic analysis and a response modification factor (R). Inelastic analysis is optionally performed to check the accuracy of the design. In this paper, a framework for application of an R factor for wind design is proposed. Theoretical background on the application and implementation is provided. Moreover, seismic and wind fatigue issues are explained for the purpose of quantifying the modification factor R for wind design.

A Study on Attenuation of Ground Vibration Using Hammer Generated Seismic Wave (탄성파탐사에 의한 토양층 지반진동의 감쇠연구)

  • 서만호;손호웅
    • The Journal of Engineering Geology
    • /
    • v.6 no.2
    • /
    • pp.95-102
    • /
    • 1996
  • A study on the attenuation of ground vibration was carried out on the soil layer using seismic exploration method. A 12-channel engineering seismograph was used to acquire real digital amplitude data in field work. Frequency analysis of seismic data shows maximum spectrum amplitude around 40Hz. Relative amplitude decreases exponentially as the distance increases and the attenuation factors are n = 0.25 and a = 0.13-0.20. Internal attenuation indexes(a) are 0.13 and 0.20 in the wet soil zone and the vegatated soil zone, respectively. It means that ground vibration attenuates faster in vegatated soil zone than in wet soil zone. Average internal attenuation coefficient(h) was determined to be 0.094 from seismic velocity and frequency analysis.

  • PDF

Seismic Evaluation of Structural Integrity of Main Cooling-Water Pump by Response Spectrum Analysis (응답스펙트럼법을 이용한 지진하중을 받는 원전용 주냉각수펌프의 내진 건전성 평가)

  • Chung, Chul-Sup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1773-1778
    • /
    • 2010
  • To evaluate the structural integrity of the main cooling-water pump of a nuclear power plant under different seismic conditions, the seismic analysis was performed in accordance with IEEE-STD-344 code. The finite element computer program, ANSYS, was used to perform both mode frequency analysis and response spectrum analysis for the pump assembly. The natural frequencies, the mode shapes, and the mode participation factors were obtained from the results of the mode frequency analysis. The stresses resulting from various loadings and their combinations were within the allowable limits specified in the above-mentioned IEEE code. The results of the seismic evaluation fully satisfied the structural acceptance criteria of the IEEE code. Thus, it was proved that the structural integrity of the pump assembly was satisfactory.

Pseudo-dynamic test of the steel frame - Shear wall with prefabricated floor structure

  • Han, Chun;Li, Qingning;Jiang, Weishan;Yin, Junhong;Yan, Lei
    • Steel and Composite Structures
    • /
    • v.20 no.2
    • /
    • pp.431-445
    • /
    • 2016
  • Seismic behavior of new composite structural system with a fabricated floor was studied. A two-bay and three-story structural model with the scale ratio of 1/4 was consequently designed. Based on the proposed model, multiple factors including energy dissipation capacity, stiffness degradation and deformation performance were analyzed through equivalent single degree of freedom pseudo-dynamic test with different earthquake levels. The results show that, structural integrity as well as the effective transmission of the horizontal force can be ensured by additional X bracing at the bottom of the rigidity of the floor without concrete topping. It is proved that the cast-in-place floor in areas with high seismic intensity can be replaced by the prefabricated floor without pouring surface layer. The results provide a reliable theoretical basis for the seismic design of the similar structural systems in engineering application.

Seismic behavior of soft storey mid-rise steel frames with randomly distributed masonry infill

  • Quayyum, Shahriar;Alam, M. Shahria;Rteil, Ahmad
    • Steel and Composite Structures
    • /
    • v.14 no.6
    • /
    • pp.523-545
    • /
    • 2013
  • In this study, the effect of presence and distribution of masonry infill walls on the mid-rise steel frame structures having soft ground storey was evaluated by implementing finite element (FE) methods. Masonry infill walls were distributed randomly in the upper storey keeping the ground storey open without any infill walls, thus generating the worst case scenario for seismic events. It was observed from the analysis that there was an increase in the seismic design forces, moments and base shear in presence of randomly distributed masonry infill walls which underlines that these design values need to be amplified when designing a mid-rise soft ground storey steel frame with randomly distributed masonry infill. In addition, it was found that the overstrength related force modification factor increased and the ductility related force modification factor decreased with the increase in the amount of masonry infilled bays and panels. These must be accounted for in the design of mid-rise steel frames. Based on the FE analysis results on two mid-rise steel frames, design equations were proposed for determining the over strength and the ductility related force modification factors. However, it was recommended that these equations to be generalized for other steel frame structure systems based on an extensive analysis.

Seismic Fragility Assessment of NPP Containment Structure based on Conditional Mean Spectra for Multiple Earthquake Scenarios (다중 지진 시나리오를 고려한 원전 격납구조물의 조건부 평균 스펙트럼 기반 지진취약도 평가)

  • Park, Won Ho;Park, Ji-Hun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.6
    • /
    • pp.301-309
    • /
    • 2019
  • A methodology to assess seismic fragility of a nuclear power plant (NPP) using a conditional mean spectrum is proposed as an alternative to using a uniform hazard response spectrum. Rather than the single-scenario conditional mean spectrum, which is the conventional conditional mean spectrum based on a single scenario, a multi-scenario conditional mean spectrum is proposed for the case in which no single scenario is dominant. The multi-scenario conditional mean spectrum is defined as the weighted average of different conditional mean spectra, each one of which corresponds to an individual scenario. The weighting factors for scenarios are obtained from a deaggregation of seismic hazards. As a validation example, a seismic fragility assessment of an NPP containment structure is performed using a uniform hazard response spectrum and different single-scenario conditional mean spectra and multi-scenario conditional mean spectra. In the example, the number of scenarios primarily influences the median capacity of the evaluated structure. Meanwhile, the control frequency, a key parameter of a conditional mean spectrum, plays an important role in reducing logarithmic standard deviation of the corresponding fragility curves and corresponding high confidence of low probability of failure (HCLPF) capacity.

Applied 2D equivalent linear program to analyze seismic ground motion: Real case study and parametric investigations

  • Soltani, Navid;Bagheripour, Mohammad Hossein
    • Geomechanics and Engineering
    • /
    • v.30 no.1
    • /
    • pp.1-10
    • /
    • 2022
  • Seismic ground response evaluation is one of the main issues in geotechnical earthquake engineering. These analyses are subsequently divided into one-, two- and three-dimensional methods, and each of which can perform in time or frequency domain. In this study, a novel approach is proposed to assess the seismic site response using two-dimensional transfer functions in frequency domain analysis. Using the proposed formulation, a program is written in MATLAB environment and then promoted utilizing the equivalent linear approach. The accuracy of the written program is evaluated by comparing the obtained results with those of actual recorded data in the Gilroy region during Loma Prieta (1989) and Coyote Lake (1979) earthquakes. In order to precise comparison, acceleration time histories, Fourier amplitude spectra and acceleration response spectra diagrams of calculated and recorded data are presented. The proposed 2D transfer function diagrams are also obtained using mentioned earthquakes which show the amount of amplification or attenuation of the input motion at different frequencies while passing through the soil layer. The results of the proposed method confirm its accuracy and efficiency to evaluate ground motion during earthquakes using two-dimensional model. Then, studies on irregular topographies are carried out, and diagrams of amplification factors are shown.

Soil-structure interaction effects on collapse probability of the RC buildings subjected to far and near-field ground motions

  • Iman Hakamian;Kianoosh Taghikhani;Navid Manouchehri;Mohammad Mahdi Memarpour
    • Earthquakes and Structures
    • /
    • v.25 no.2
    • /
    • pp.99-112
    • /
    • 2023
  • This paper investigates the influences of Soil-Structure Interaction (SSI) on the seismic behavior of two-dimensional reinforced concrete moment-resisting frames subjected to Far-Field Ground Motion (FFGM) and Near-Field Ground Motion (NFGM). For this purpose, the nonlinear modeling of 7, 10, and 15-story reinforced concrete moment resisting frames were developed in Open Systems for Earthquake Engineering Simulation (OpenSees) software. Effects of SSI were studied by simulating Beam on Nonlinear Winkler Foundation (BNWF) and the soil type as homogenous medium-dense. Generally, the building resistance to seismic loads can be explained in terms of Incremental Dynamic Analysis (IDA); therefore, IDA curves are presented in this study. For comparison, the fragility evaluation is subjected to NFGM and FFGM as proposed by Quantification of Building Seismic Performance Factors (FEMA P-695). The seismic performance of Reinforced Concrete (RC) buildings with fixed and flexible foundations was evaluated to assess the probability of collapse. The results of this paper demonstrate that SSI and NFGM have significantly influenced the probability of failure of the RC frames. In particular, the flexible-base RC buildings experience higher Spectral acceleration (Sa) compared to the fixed-base ones subjected to FFGM and NFGM.